• 제목/요약/키워드: Flat plate type collector

검색결과 25건 처리시간 0.024초

평판형 집열기에서 일사성분의 유효성에 관한 연구 (Research on Effective Use of Radiation for Flat plate Type Collector)

  • 최성우;정성식;하종률;하도양개
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 춘계학술대회
    • /
    • pp.2135-2140
    • /
    • 2004
  • This study represented experimental research on the flat plate solar collector. For the flat plate Solar system, it is sensitive of the Global radiation. In Actually, it suppose to be dependent on the direct radiation. Also, the existing method's factors are depend upon Global radiation in the flat plate collector system. therefore it needs which is depend upon direct radiation. In this experiment, the flat plate collector is used for obtaining the method's factors of the direct radiation. As a result, the correct $({\tau}{\alpha})_e$ is found out for practical value.

  • PDF

여러 가지 종류의 태양열 집열기 작동성능 비교 분석 연구 (The study on the comparison of the operation performance of different type of solar collectors)

  • 김휘동;백남춘;이진국;주문창
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2010년도 추계학술대회 초록집
    • /
    • pp.64.2-64.2
    • /
    • 2010
  • The objective of this study is to make a comparative study of the operation performance of different type of solar collectors. A flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector are used in this study. These 3 type of collectors are connected in series in the order of a flat-plate collector, a single-glazed evacuated collector and a double-glazed evacuated collector. This experimental facility is a kind of a solar system with a controller, a heat exchanger, a storage tank and a circulation pump. Each collector has a different collection area(flat-plate collector-$6.00m^2$ total area/$5.61m^2$ aperture area, double-glazed evacuated collector-$6.04m^2$ total area/$4.92m^2$ aperture area, single-glazed evacuated collector-$7.65m^2$ total area/$5.61m^2$ aperture area) and its performance characteristic respectively. The experiments have been demonstrated at around $70^{\circ}C$ operating temperature(flat-plate collector inlet temperature). The thermal collecting efficiencies of each collector are obtained under the different insolation and operation condition as a result.

  • PDF

PTC와 평판형 태양열집열기의 성능평가 비교 연구 (The Comparative Study on Performance of PTC and Flat-plate Solar Collector)

  • 김인환;허남수;김만석;이정언
    • 한국태양에너지학회 논문집
    • /
    • 제30권6호
    • /
    • pp.28-33
    • /
    • 2010
  • Solar collectors to be applied are mainly flat-plate or vacuum tube collector which is used for hot water supply of house because of low heat value and low temperature. There are a necessity to expand applicable scope of solar collector into the industrial process heat source and air conditioner for coping with renewable energy policy of government and industrial trend. This study is to analysis the performance of PTC solar collector of concentrating type and flat-plate of non-concentrating. For this, temperature difference and heating value as insolation of air outside is measured from these two collectors mounted on 2-axial solar tracking system. It is investigated that temperature profile obtained from PTC solar collector is uniform and collecting heat per unit area is 6.8kcal/$m^2$ min which is about 3 times with compare to flat-plate collector of 2kcal/$m^2$min. Also the amount of heat to be produced from PTC solar collector is 3 Mcal/$m^2$ which is about 2 times with compare to flat-plate collector of 1.5Mcal/$m^2$ as a result of operating these two collectors during one month. Therefore, it is obtained that heat collecting performance of PTC solar collector is superior to flat-plate.

지역난방 적용 태양열시스템의 장기 열성능 분석 (Analysis of Long-term Thermal Performance of Solar Thermal System Connected to District Heating System)

  • 백남춘;신우철
    • 한국태양에너지학회 논문집
    • /
    • 제27권4호
    • /
    • pp.167-173
    • /
    • 2007
  • This study analyzed by simulation using TRNSYS as well as by experiment on the solar district heating system installed for the first time for the district heating system in Bundang. Simulation analysis using TRNSYS focused on the thermal behavior and long-term thermal efficiency of solar system. Experiment carried out for the reliability of simulation system. This solar system where the circuits of two different collectors, flat plate and vacuum tube collector, are connected in series by a collector heat exchanger, and the collection characteristics of each circuit varies. Therefore, these differences must be considered for the system's control. This system uses variable flow rate control in order to obtain always setting temperature of hot water by solar system. Specifically, this is a system that heats returning district heating water (DHW) at approximately $60^{\circ}C$ using a solar collector without a storage tank, up to the setting temperature of approximately $85{\sim}95^{\circ}C$ To realize this, a flat plate collector and a vacuum tube collector are used as separate collector loops. The first heating is performed by a flat plate collector loop and the second by a vacuum tube collector loop. In a gross collector area basis, the mean system efficiency, for 4 years, of a flat plate collector is 33.4% and a vacuum tube collector is 41.2%. The yearly total collection energy is 2,342GJ and really collection energy per unit area ($m^2$) is 1.92GJ and 2.37GJ respectively for the flat plate vacuum tube collector. This result is very important on the share of each collector area in this type of solar district heating system.

해상적용 평판형 태양열 집열기의 집열특성 (Thermal Concentration Characteristic of Flat Plate Solar Collector for Application on the Sea)

  • 지명국;정효민;정한식;이철재
    • 태양에너지
    • /
    • 제20권4호
    • /
    • pp.9-16
    • /
    • 2000
  • This paper represents the heat storage performance of the flat plate solar collector. This research aims to application for fishing ship on the sea, and the solar collector has among of motions with pitching and rolling thus, this collector has to be a forced type circulation. In this research, we investigated the solar collector performance for the various collector tilt angle. As the experimental results with three types, we found that the S-type collector was excellent.

  • PDF

Ultrasonic Welding Technology for Solar Thermal Collector

  • Kim, Sung-Wook;Chun, Chang-Keun;Kim, Sook-Hwan
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2009년 추계학술발표대회
    • /
    • pp.221-225
    • /
    • 2009
  • A solar thermal collector is a solar collector specifically intended to collect heat: that is, to absorb sunlight to provide heat. A flat plate is the most common type of solar thermal collector, and is usually used as a solar hot water panel to generate solar hot water. A flat plate collector consists basically of an insulated metal box with a glass or a plastic cover and a dark-colored copper absorber plate. Solar radiation is absorbed by the copper absorber plate and transferred to water that circulates through the collector in copper tubes. Ultrasonic welding is an industrial technique whereby high-frequency ultrasonic acoustic vibrations are locally applied to work pieces being held together under pressure to create a solid-state weld. In this study, we developed solar collector ultrasonic welding machine with digital controlled power supply and tested various welding conditions such as welding pressure, welding amplitude, welding speed. Welding speed was considered in 2~12m/min. The width of ultrasonic welds was increased with welding amplitude by 2.2~2.5mm. The fracture load of ultrasonic welds showed 20% higher than domestic products.

  • PDF

수직벽면형 무동력 태양열 시스템 작동성능에 관한 실험적 연구 (An experimental study on the operating performance of facade installed natural circulation type solar thermal system)

  • 백남춘;이왕제;이진국;이순명
    • 한국태양에너지학회 논문집
    • /
    • 제35권4호
    • /
    • pp.1-7
    • /
    • 2015
  • The operation of the natural circulation type solar heating systems with facade integrated collector was analyzed by experiment. Two different types of flat plate solar collectors were used for these experiments. One was for the normal flat plate solar collector with the size of 1m*2m and the other was for the large size solar collector with $4m^2$(1m*4m). The experiments were carried out to investigate the effect of the series or parallel connection method on the performance of the collectors. As a result, the solar thermal system which is installed on the wall or facade would be applicable for the natural circulation type if the system design reflects various parameters, including collector connecting method(series or parallel), to provide enough vertical height between collector and storage tank, and to reduce pressure loss due to collector and piping network, etc. The natural circulation type of solar thermal system as proposed in this study can increase the system reliability by removing or minimizing the use of the components such as pump, controller, sensors which may cause serious troubles of the system for a long-time operation

지역난방용 태양열시스템 (Solar District Heating System)

  • 백남춘;이진국;윤응상;윤석만;신우철
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.663-668
    • /
    • 2008
  • This study was carried out solar heating system design for district heating and it's the performance analysis by experiment. This experimental system was installed in Bundang district heating area in the end of 2006. The flat plate and vacuum tube solar collector are combined in one system. So district heating water is heated first by flat plate solar collector and than by vacuum tube solar collector. This solar heating system has not a solar buffer tank and is operating with variable flow rate to obtain a setting temperature of $90{\sim}95^{\circ}C$. As a result, the daily solar thermal collection efficiency is about 30 to 40% for the plate type and 50 to 55% for the vacuum tube solar collector. It varied especially depend on the weather condition like as solar radiation and ambient temperature. This variable flow rate system can be also reduced much pumping power more than 50%.

  • PDF

TRNSYS 기반 무창기공형 공기식 집열 시스템 부프로그램 개발에 관한 연구 (Study on Development of Subroutine based on TRNSYS for Unglazed Transpired Air Collector System)

  • 박준언;이의준;정모
    • 한국태양에너지학회 논문집
    • /
    • 제23권2호
    • /
    • pp.81-90
    • /
    • 2003
  • UTAC(unglazed transpired air collector) system has unique advantage for space heating and tempering ventilation air over the conventional collector system such as flat plate and vacuum collector. UTAC can improve radiative and convective loss due to nonglazed component and enhanced plate surface configuration. and heating energy and its equivalent green house emission performance can be improved from the use of this like collector in building application. The Option D Calibration simulation approach of IPMVP(International Performance Measurement and Verification Protocol) in ESCO businesses has been recommended to use of the calibrated computer modules like these Energy-10. DOE2.1E and TRNSYS(transient system simulation). This study is to develop subroutine type-203 of TRNSYS15.2 program and appraise thermal performance of UTAC. With newely addeded subroutine type-203. 1) Thermal performance of unglazed transpired collector could be possible based on dimensionless variables such as efficiency and heat exchanger effectiveness. and 2) Assessement of energy consists of solar useful and insulation saving for UTAC could be possible.

평판형 태양열 집열판의 집열관 온도분포 특성 (The Characteristics of Temperature Distributions for Flat Tube Type Solar Collector Type)

  • 모종근;배철환;정효민;정한식
    • 태양에너지
    • /
    • 제19권3호
    • /
    • pp.85-91
    • /
    • 1999
  • This study represented experimental research on the flat-plate solar collector. The heat performances were measured the tube array surface temperature by thermal-couple. The solar collector($W{\times}H$) of $580{\times}1100$, various tilt angles of 30, 45, 60 degree and the internal tube number of 4, 6, 8, 10(ea) were utilized in the present investigation. It is found that the thermal concentration is higher as the tilt angle become larger and the solar tubes are more and more. In this stuby obtained results of following: The array of tubes in collector has the best nice in that the number of tube is eight and the tilt angle is 60 degree. The collect energy by each tube array shown high value by increase the number of tubes and tilt angles. In addition to, the collect energy depends on by the tilt angle than the number of tube.

  • PDF