• Title/Summary/Keyword: Flat Panel Detector

Search Result 82, Processing Time 0.032 seconds

Rotating-Gantry-Based X-Ray Micro-Tomography System with the Sliding Mechanism Capable of Zoom-In Imaging

  • Cho, Min-Hyoung;Lee, Dong-Hun;Han, Byung-Hee;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.29 no.2
    • /
    • pp.107-113
    • /
    • 2008
  • We introduce a rotating-gantry-based x-ray micro-tomography system to be used for small animal imaging studies. It has the zoom-in imaging capability for high resolution imaging of a local region inside the animal subject without any contrast anomalies arising from truncation of the projection data. With the sliding mechanism mounted on the rotating gantry holding the x-ray source and the x-ray detector, we can control the magnification ratio of the x-ray projection data. By combining the projection data from the large field of view (FOV) scan of the whole animal subject and the projection data from the small FOV scan of the region of interest, we can obtain artifact-free zoomed-in images of the region of interest. For the acquisition of x-ray projection data, we use a $1248{\times}1248$ flat-panel x-ray detector with the pixel pitch of 100 mm. It has been experimentally found that the developed system has the spatial resolution of up to 121p/mm when the highest magnification ratio of 5:1 is applied to the zoom-in imaging. We present some in vivo rat femur images to demonstrate utility of the developed system for small animal imaging.

System of a Selenium Based X-ray Detector for Radiography (일반촬영을 위한 셀레늄 기반의 엑스선 검출기 시스템)

  • Lee, D.G.;Park, J.K.;Choi, J.Y.;Ahn, S.H.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.07b
    • /
    • pp.817-820
    • /
    • 2002
  • Amorphous selenium based flat panel detectors convert incident x-ray to electric signal directly. Flat panel detectors gain more interest real time medical x-ray imaging. TFT array and electric readout circuits are used in this paper offered by LG.Philips.LCD. Detector is based on a $1536{\times}1280$ array of a-Si TFT pixels. X-ray conversion layer(a-Se) is deposited upper TFT array with a $400{\mu}m$ by thermal deposition technology. Thickness uniformity of this layer is made of thickness control system technology$({\leq}5%)$. Each $139{\mu}m{\times}139{\mu}m$ pixel is made of thin film transistor technology, a storage capacitor and collecting electrode having geometrical fill factor of 86%. This system show dynamic performance. Imaging performance is suited for digital radiography imaging substitute by conventional radiography film system.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Zoom-in X-ray Micro Tomography System

  • Chun, In-Kon;Lee, Sang-Chul;Park, Jeong-Jin;Cho, Min-Hyoung;Lee, Soo-Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.5
    • /
    • pp.295-300
    • /
    • 2005
  • We introduce an x-ray micro tomography system capable of high resolution imaging of a local region inside a small animal. By combining two kinds of projection data, one from a full field-of-view (FOV) scan of the whole body and the other from a limited FOV scan of the region of interest, we have obtained zoomed-in images of the region of interest without any contrast a nomalies. We have integrated a micro tomography system using a micro-focus x-ray source, a $1248\times1248$ flat-panel x-ray detector, and a precision scan mechanism. Using the cross-sectional images taken with the zoom-in micro tomography system, we measured trabecular thicknesses of femur bones in postmortem rats. To compensate the limited spatial resolution in the zoom-in micro tomography images, we used the fuzzy distance transform for the calculation of the trabecular thickness. To validate the trabecular thickness measurement with the zoom-in micro tomography images, we compared the measurement results with the ones obtained from the conventional micro tomography images of the extracted bone samples.

A Study on Quality Control for Medical Image by Using Deviation Index of Digital Radiology (디지털 방사선 영상의 편차지수를 이용한 의료영상 품질관리에 관한 연구)

  • Jeong, Hoi-Woun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.43 no.2
    • /
    • pp.115-121
    • /
    • 2020
  • In a digital radiation system using a Flat Panel Detector, we attempted to the quality control of digital radiography system using the Exposure Index and Deviation Index. Calibration was performed with the radiation quality suggested by the International Electrotechnical Commission, and through an experiment using a phantom, appropriate inspection radiation conditions applicable to medical institutions were selected. The study was conducted using the selected radiation conditions. Through those chest posterior anterior image, information such as examination conditions and exposure index was obtained. The deviation index was derived by analyzing the exposure index based on the target exposure index calculated by the phantom study. As for the analyzed exposure index, 97.1% was distributed within the range of ± 2.0 based on the deviation index. Quality control of medical images should be performed through management of inspection conditions through exposure index and deviation index and management of medical images.

The Comparison of X-ray Response Characteristics of Vacuum Evaporated $Cd_{1-x}Zn_{x}Te$ Detector (진공증착된 $Cd_{1-x}Zn_{x}Te$ 검출기의 X선 반응 특성 비교)

  • Kang, S.S.;Choi, J.Y.;Lee, D.G.;Cha, B.Y.;Kim, J.H.;Nam, S.H.
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.39-42
    • /
    • 2002
  • There is a renewed interest in the application of photoconductors especially Cd(Zn)Te to x-ray imaging. In this paper, We investigate effects on x-ray detection characteristic of Zn dopped CdTe detector. Cd(Zn)Te film was fabricated by vacuum thermal evaporation method and then investigate physical analysis using EPMA and XRD. We investigated the leakage current and X-ray photosensitivity as applied voltage about fabricated Cd(Zn)Te film. Experimental results showed that the increase of Zn dopped concentration in $Cd_{1-x}Zn_{x}Te$ detector reduced a leakage current and improved a signal to noise ratio significantly.

  • PDF

Semiconductor Detectors for Radiation Imaging Applications (방사선 영상 장치용 반도체 검출기)

  • Park, K.S.;Park, J.M.;Yoon, Y.S.;Kim, B.W.;Kang, J.Y.
    • Electronics and Telecommunications Trends
    • /
    • v.22 no.5
    • /
    • pp.95-107
    • /
    • 2007
  • X-선 측정 및 영상장치를 포함한 다양한 응용분야에서 방사선에 대한 고해상도의 영상을 얻기 위한 목적으로 반도체 검출기에 대한 개발이 활발히 진행되고 있다. 본 고에서는 방사선 검출을 위해 요구되는 반도체 물질의 주요 특성에 대해서 조사하였다. 또한 반도체를 이용한 플랫 패널(flat panel) 시스템, 픽셀 디텍터(pixel detector)와 스트립 디텍터(strip detector) 등의 혼성형 디텍터(hybrid detector), MAPS와 DEPFET 등의 단일형 픽셀 디텍터(monolithic pixel detector)의 디바이스 동작 원리 및 특성과 국내외 기술 동향에 대하여 살펴보았다.

Zinc Sulfide-selenium X-ray Detector for Digital Radiography

  • Park, Ji-Koon;Kang, Sang-Sik;Kim, Jae-Hyung;Mun, Chi-Woong;Nam, Sang-Hee
    • Transactions on Electrical and Electronic Materials
    • /
    • v.3 no.4
    • /
    • pp.16-20
    • /
    • 2002
  • The high bias voltage associated with the thick layer (typically 500-1000 ㎛) of selenium required to have an acceptable x-ray absorption in radiography and fluoroscopy applications may have some practical inconvenience. A hybrid x-ray detector with zinc sulfide-amorphous selenium structure has been developed to improve the x-ray sensitivity of a a-Se based flat-panel digital imaging detector. Photoluminescence(PL) characteristic of a ZnS:Ag phosphor layer showed a light emission peak centered at about 450 nm, which matches the sensitivity spectrum of selenium. The dark current of the hybrid detector showed similar characteristics with that of a a-Se detector. The x-ray sensitivity of hybrid and a-Se x-ray detector was 345 pC/㎠/mR and 295 pC/㎠/mR at an applied voltage of 10 V/㎛, respectively. The purpose of this study was to evaluate the pertinence of a solution using a thin selenium layer, as a photosensitive converter, with a thick coating of silver doped zinc sulfide phosphor.

The characteristic study of hybrid X-ray detector using ZnS:Ag phosphor (ZnS:Ag phosphor를 이용한 hybrid 형 X-ray detector 특성 연구)

  • Park, Ji-Koon;Gang, Sang-Sik;Lee, Dong-Gil;Cha, Byeong-Yeol;Nam, Sang-Hee;Choi, Heung-Kook
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05b
    • /
    • pp.27-30
    • /
    • 2002
  • Photoconductor for direct detection flat-panel imager present a great materials challenge, since their requirements include high X -ray absorption, ionization and charge collection, low leakage current and large area deposition. Selenium is practical material. But it needs high thickness and high voltage in selenium for high ionization rate. We report comparative studies of detector sensitivity. One is an a-Se with $70{\mu}m$ thickness on glass. The other has hybrid layer of depositting ZnS phosphor with $100{\mu}m$ on a-Se. The leakage current of hybrid is similar to it of a-Se, but photocurrent is lager than a-Se. Both of them have high spatial resolution, but hybrid has higher sensitivity than a-Se at comparable bias voltage.

  • PDF