• Title/Summary/Keyword: Flat

Search Result 7,918, Processing Time 0.037 seconds

A Comparative Study of the Flat Jacket Pattern and the Draping Jacket Pattern for the 20's Female (20대 여성재킷원형의 평면재단법과 입체재단법 비교)

  • Kim, Hee-Jin;Lee, Young-Ju
    • Korean Journal of Human Ecology
    • /
    • v.12 no.1
    • /
    • pp.53-61
    • /
    • 2003
  • The purpose of this study was to compare the flat pattern with the draping pattern for the jacket. The results of this study were as follows: 1) According to the sensory evaluation for the movement, P2 flat pattern was more comfortable than the draping pattern at 88-94(N)-160 (77size). 2) The sensory evaluation was applied to evaluate the draping pattern was superior to the flat pattern for the collar at 82-90(N)-160(55size), 85-92(N)-160(66size) and 88-94(N)-160(77size). 3) The draping pattern was superior to the flat pattern in the sensory evaluation for the front and back. 4) Lee Hyung-Suck's flat pattern (P1) was better in appearance than the P2 and the draping pattern (P3) for the side sensory evaluation at 82-90(N)-160(55size) and 85-92(N)-160(66size).

  • PDF

Methods of punching shear strength analysis of reinforced concrete flat plates-A comparative study

  • Loo, Y.C.;Chiang, C.L.
    • Structural Engineering and Mechanics
    • /
    • v.1 no.1
    • /
    • pp.75-86
    • /
    • 1993
  • The punching shear strength of concrete flat plates is one of the topics of intensive research in recent years by various concrete structures researchers. This paper reviews four current methods of analysing the punching shear strength at the corner-and edge-column positions of reinforced concrete flat plates. They include those recommended in the Australian Standard AS3600-1988, the American Concrete Institute ACI318-89 and the British Standard on Concrete Practices (BS8110) as well as the approach developed at the University of Wollongong, Australia. Based on half-scale model test results, a comparative study of these four analysis methods is made with regard to their limitation, accuracy and reliability. It is found that the Wollongong approach in general gives the best performance in predicting the punching shear strength of flat plates with torsion strips and those with spandrel beams. The Australian Standard procedure performs just as satisfactorily for flat plates with torsion strips but tends to be unsafe for those with spandrel beams. Both the ACI and the British methods are applicable only to flat plates with torsion strips; they also tend to give unsafe predictions for the punching shear strength.

Analysis of Seismic Performance of Slim Flat Plate System in High-rise Hybrid Structural System (슬림형 바닥시스템을 이용한 고층 복합구조의 내진성능에 관한 해석적 연구)

  • Ha Gee Joo;Park Hyo Sun;Park Joung Hyen;Choi Kyung Ryeol;Kim Dae Joung;Jung Jea Kwang
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2005.11a
    • /
    • pp.77-80
    • /
    • 2005
  • Recently the construction of high-rise hybrid type building is progressively increased as the social demands. It is significantly important factors such as economy, the safety of structure, and the flexibility of internal space. Therefore new hybrid structural system, using slim flat plate system, is also required to be attained the reduction of story height, the flexibility and efficient use of space. The most suitable structural system is ,with the economy and flexibility, flat plate system in high-rise hybrid type building. But it was focused in the seismic performance for high performance flat plate system in high-rise hybrid type building. Therefore, in the study, to develop the new flat-plate system with high ductile, durable, good performance for the applications. It was evaluated the seismic performance in the critical region of slab-column connection. And then high performance flat plate system, designed by the economy and safety, was developed as a new technique in the application of high-rise hybrid type building.

  • PDF

Design of the High Density Power Supply with Flat Transformer (Flat Transformer를 적용한 고밀도 전원장치 설계)

  • Baek J.W.;Kim J.H.;Yoo D.W.;Kim J.S.;Ryu M.H.
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.10 no.3
    • /
    • pp.248-256
    • /
    • 2005
  • This paper presents the design method of the DC/DC converter using flat transformer which is suitable for midium or large capacity and high density power supply. Flat transformer module is composed and manufactured of multi-transformers in parallel and has a number of parallel single turn secondary windings. Therefore, its leakage inductance is highly decreased and it is more suitable for high frequency operation than conventional one. In this paper, we manufactured and tested 750W AC/DC converter with variable output powers to verify the performance of the flat transformer.

Analysis on Topography and Exposure Duration of Siheung Tidal Flat Using Remote Sensing Techniques (위성영상 분석기술을 이용한 시흥갯벌의 지형 및 노출시간 분석)

  • Koo, Bon Joo;Kim, Minkyu
    • Ocean and Polar Research
    • /
    • v.35 no.4
    • /
    • pp.291-298
    • /
    • 2013
  • In order to investigate the topography and exposure duration of the Siheung tidal flat, tidal ranges and DEM constructed by remote sensing techniques were analyzed. A cross-sectional diagram of the intertidal area reveals that it is relatively flat in the upper zone and then abruptly plunges into the bottom of the main channel where elevations increase in an upstream direction. The waterline during the Highest Low Water (HLW) is drawn back to the bottom of the channel at the middle part of the tidal flat and is formed along the slant of the channel during the Lowest High Water (LHW). The intertidal zone is located between -410 cm and 510 cm in terms of elevation and its total area is $0.65km^2$. An area between the Highest High Water (HHW) and Lowest High Water (LHW), occupying about 80% of the total area, occupies $0.52km^2$ of total area and accounts for 56% of the exposure duration. The boundary of wetland protection area in the Siheung tidal flat did not exactly coincide with the intertidal regime and differs by more than 15%. This study, which precisely analyzed the tidal flat area, tidal environment, and topography, would be useful in making a conservation plan and in learning how to use a wetland protection area in a sustainable manner.

Study of the Impulse Wave Impinging upon an Inclined Flat Plate (경사판에 충돌하는 펄스파에 관한 연구)

  • Kweon, Y.H.;Lee, D.H.;Kim, H.D.
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.438-443
    • /
    • 2001
  • Plate impingement of the impulse wave discharged from the open end of a duct is numerically investigated using a CFD method. Harten-Yee Total Variation Diminishing method is used to solve the unsteady, compressible flow governing equations. The Mach number, the flat plate inclination and the distance between the duct exit and inclined flat plate are changed to investigate their effects on the impinging flow field. The impulse wave impingement on the inclined flat plate depends on Mach number $M_s$ and the plate inclination $\psi$. The pressure distributions on the inclined flat plate show that for a small r/D, the peak pressure at the center of an inclined flat plate decreases with an increase in the plate inclination $\psi$ in the range of $\psi$ from $45^{\circ}$ to $60^{\circ}$ but for a large r/D, the peak pressure decreases with an increase in $\psi$ in the range of $\psi$ from $75^{\circ}$ to $90^{\circ}$. It is also found that for all of r/D, the peak pressure at the center of an inclined flat plate has a maximum value in $\psi=90^{\circ}$.

  • PDF

Local and Overall Heat Transfer Characteristics of Fin- Flat Tube Heat Exchanger with Vortex Generators

  • Yoo, Seong-Yeon;Chung, Min-Ho;Park, Dong-Seong
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • v.11 no.3
    • /
    • pp.150-157
    • /
    • 2003
  • Local and overall heat transfer characteristics of fin-flat tube heat exchangers with and without vortex generators were investigated. Local heat transfer coefficients were measured with the heat exchanger model using naphthalene sublimation technique. In case of a fin-flat tube heat exchanger without vortex generators, only the horseshoe vortices formed around tubes augment the heat transfer. On the other hand, longitudinal vortices created artificially by vortex generators additionally enhance heat transfer in case of a fin-flat tube heat exchanger with vortex generators. Overall heat transfer coefficients were measured with the prototypes of the fin-flat tube heat exchanger with and without vortex generators in a wind tunnel and results were compared with those of a fin-circular tube heat exchanger with wavy fin. Friction losses for heat exchangers were also measured and compared. The fin-flat tube heat exchanger with vortex generators is found to be more effective than the fin-circular tube heat exchanger with wavy fin.

A STUDY OF THE MANDIBULAR CONDYLE SHAPE ON THE INDIVIDUALIZED CORRECTED TMJ TOMOGRAPH AND SUBMENTOVERTEX RADIOGRAPH (이하두정방사선사진과 개별화 단층방사선사진을 이용한 하악과두의 형태에 관한 연구)

  • 이상래
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.24 no.2
    • /
    • pp.227-236
    • /
    • 1994
  • The purpose of this study was to observe mandibular condyle shape in an asymptomatic population. In order to carry out this study, 96 temporomandibular joints in 48 adults(22 males, 26 females), who were asymptomatic for temporomandibular disturbances and had no history of prosthodontic or orthodontic treatments, were selected, and radiographed using the Sectograph(Denar Co., U.S.A.) for lateral and frontal individualized corrected TMJ tomograph and submentovertex radiograph. Mandibular condyles were classified morphologically, and measured medioateral and anteroposterior dimensions and condylar angulation. The obtained results were as follows. 1. In the classification of condyle shape on lateral tomographs, 94.8% were convex type and 5.2% were angled type. 2. In the classification of condyle shape on frontal tomographs, 45.3% were convex type, 32.0% were round type, 16.0% were flat type, and 6.7% were angled type. 3. In the classification of condyle shape on submentovertex radiographs, 34.5% were flat-convex type, 22.9% were flat-flat type, 20.8% were concave-convex type, 19.8% were convex-convex type, and 1.0% were concave-flat type and convex-flat type. Concave-concave type, convex-concave type, and flat-concave type were not observed. 4. The average mediolateral legth of the condyle was 19.3㎜ and the average anteroposterior length was 9.4㎜. The average angle between the long axis of condyle and the coronal plane made on submentovertex view was 19.6 degrees.

  • PDF

Design and Simulation Technologies of Flat Transformer with High Power Current (대전류 출력형 Flat Transformer 설계 및 해석 기술)

  • Han, Se-Won;Cho, Han-Goo;Woo, Bung-Chul
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2002.05c
    • /
    • pp.15-17
    • /
    • 2002
  • Leakage inductance and temperature rise are two of the more impotent problems facing the magnetic core technology of today's high frequency transformers. Excessive leakage inductance increases the stress on the switching transistors and limits the duty-cycle, and excessive temperature rise can lead the design limitation of high frequency transformer with high current. The flat transformer technology provides a very good solution to the problems of leakage inductance and thermal management for high frequency power. The critical magnetic components and windings are optimized and packaged within a completely assembled module. The turns ratio in a flat transformer is determined as the product of the number of elements or modules times the number of primary turns. The leakage inductance increase proportionately to the number of elements, but since it is reduced as the square of the turns, the net reduction can be very significant. The flat transformer modules use cores which have no gap. This eliminates fringing fluxes and stray flux outside of the core. The secondary windings are formed of flat metal and are bonded to the inside surface of the core. The secondary winding thus surrounds the primary winding, so nearly all of the flux is captured.

  • PDF

Inference Models for Tidal Flat Elevation and Sediment Grain Size: A Preliminary Approach on Tidal Flat Macrobenthic Community

  • Yoo, Jae-Won;Hwang, In-Seo;Hong, Jae-Sang
    • Ocean Science Journal
    • /
    • v.42 no.2
    • /
    • pp.69-79
    • /
    • 2007
  • A vertical transect with 4 km length was established for the macrofaunal survey on the Chokchon macrotidal flat in Kyeonggi Bay, Incheon, Korea, 1994. Tidal elevation (m) and sediment mean grain size $(\phi)$ were inversely predicted by the transfer functions from the faunal assemblages. Three methods: weighted average using optimum value (WA), tolerance weighted version of the weighted average (WAT) and maximum likelihood calibration (MLC) were employed. Estimates of tidal elevation and mean grain size obtained by using the three different methods showed positively corresponding trends with the observations. The estimates of MLC were found to have the minimum value of sum of squares due to errors (SSE). When applied to the previous data $(1990\sim1992)$, each of three inference models exhibited high predictive power. This result implied there are visible relationships between species composition and faunas' critical environmental factors. Although a potential significance of the two major abiotic factors was re-affirmed, a weak tendency of biological interaction was detected from faunal distribution patterns across the flat. In comparison to the spatial and temporal patterns of the estimates, it was suggested that sediment characteristics were the primary factors regulating the distribution of macrofaunal assemblages, rather than tidal elevation, and the species composition may be sensitively determined by minute changes in substratum properties on a tidal flat.