• Title/Summary/Keyword: Flapless implant surgery

Search Result 27, Processing Time 0.022 seconds

BLOOD VESSELS OF THE PERI-IMPLANT MUCOSA: A COMPARISON BETWEEN FLAP AND FLAPLESS PROCEDURES (피판과 무피판 임플란트 수술 후 임플란트 주위 점막의 혈관분포 비교)

  • Kim, Jung-In;Choi, Byung-Ho;Xuan, Feng;Kim, Ha-Rang;Mo, Dong-Yub
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.35 no.2
    • /
    • pp.101-105
    • /
    • 2009
  • Background: The vascularity of the peri-implant tissue is a very important parameter in establishment and maintenance of a healthy tissue after dental implant insertion. Objective: The purpose of this study was to compare the vascularity of the peri-implant mucosa between flap and flapless implant surgeries by using a canine mandible model. Study Design: In six mongrel dogs, bilateral, edentulated, flat alveolar ridges were created in the mandible. After 3 months of healing, two implants were placed in each side by either the flap or flapless procedures. After another healing period of 3 months, biopsies were obtained, prepared for light microscopy and exposed to morphometric measurements. Results: The supracrestal connective tissue lateral to the implant was found to be more richly vascularized in the flapless group than in the flap group. Conclusion: These results suggest that the flapless procedure may have an effect on increasing the vascularity of the peri-implant mucosa.

Radiographic evaluation of marginal bone level alteration around narrow implants placed in narrow alveolar ridge using guided flapless surgery (폭이 좁은 치조골에서 컴퓨터가이드를 이용한 무절개 임플란트 수술로 식립한 narrow implant의 방사선학적 평가)

  • Jeong, Seung-Mi;Choi, Byung-Ho
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.58 no.4
    • /
    • pp.306-312
    • /
    • 2020
  • Purpose: The aim of this study was to compare radiographic outcomes around narrow-diameter implants placed using guided flapless surgery at longer than 6 month post-placement. Materials and methods: A total of 12 implants were assessed in 12 patients for the sites where 0.5 - 1.5 mm labial bone was covering the implants, using CBCT. Results: A statistically significant preservation of crestal bone was observed in the narrow-diameter implants. Conclusion: Guided flapless implant surgery may be important in preventing bone loss around the narrow-diameter implants that are placed in narrow alveolar ridges.

Retrospective Clinical Study on Flapless Implant Placement

  • Kim, Jong-Hee;Kim, Young-Kyun;Yi, Yang-Jin
    • Journal of Korean Dental Science
    • /
    • v.5 no.2
    • /
    • pp.54-59
    • /
    • 2012
  • Purpose: The purpose of this study was to evaluate the prognosis (clinical outcomes) of one-stage flapless implant surgery based on success and survival rate and marginal alveolar bone loss. Materials and Methods: Ninety dental implants were placed according flapless surgical procedure in forty-one patients at Hospital between April 2004 and May 2009. The mean age of the patients was 54, and the patients were comprised of 24 men and 17 women. Each patient was investigated radiographically and clinically being with average follow up 49.7 period. Result: Average healing period is 4.45 month (maxilla: 5.31 month, mandible: 3.20 month) after installation and survival rate is 95.7% in this period. The survival rate and success rate at 1 year after function (prosthodontics setting) are 92.4% and 88.0%. At final observation, the survival rate and success rate are 90.2% (maxilla: 89.1%, mandible: 92.9%) and 84.8% (maxilla: 82.8%, mandible: 89.3%). The mean residual alveolar bone resorption at 1-year after function and final observation are 0.8 mm and 1.07 mm. Conclusion: Our study suggest that if appropriate surgical technique with proper patients selection, flapless implants surgery is predictable simple and safety technique.

Full mouth rehabilitation of a patient with severe periodontitis using immediate loading after computer aided flapless implant surgery (심한 치주질환을 가진 환자에서 computer aided flapless surgery와 즉시 부하를 통한 전악 구강 회복 증례)

  • Kang, Seong hun;Choi, Yeon jo;Ryu, Jae jun
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.34 no.1
    • /
    • pp.46-55
    • /
    • 2018
  • Oral rehabilitation of a patient having severe periodontitis with alveolar bone resorption and periodontal inflammation presents a challenge to clinicians. However, if appropriate implant placement according to the bone shape is selected, unnecessary bone grafting or soft tissue surgery can be minimized. In recent years, using cone beam CT and software, it has become possible to operate the planned position with the surgical guide made with 3D printing technology. This case was a 70 years old female patient who required total extraction of teeth due to severe periodontitis and performed a full-mouth rehabilitation with an implant - supported fixed prosthesis. During the surgery, the implant was placed in a flapless manner through a surgical guide. Immediate loading of the temporary prosthesis made by CAD/CAM method before surgery was done. Since then, we have produced customized abutments and zirconia prostheses, and have reported satisfactory aesthetic and functional recovery.

Implant stability installed with CAD-CAM assisted flapless surgery : A pilot study (CAD-CAM assisted flapless 수술법으로 식립된 임플란트의 안정성 : 기초연구)

  • Park, Chan-Jin;Kim, Dae-Gon;Cho, Lee-Ra;Kashiwagi, Kosuke;Kawazoe, Takayoshi;Tanaka, Masahiro
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.27 no.4
    • /
    • pp.405-413
    • /
    • 2011
  • It was proposed that technologies derived from CAD-CAM and computed tomography may be useful for flapless implant treatment procedures. The aims of this study were to validate the reliability of this concept in a prospective 12-month clinical study. Twelve patients with fully edentulous areas in their mandibles were included in this study. A total of 71 implants were inserted in interforaminal regions by use of a CAD/CAM drill template($NobelGuide^{TM}$), specially designed for flapless implant surgery. To assess the degree of pain and discomfort, the patients were examined at 2 days and 1 week after surgery. Patient satisfaction and implant functionality were further evaluated at follow-up intervals of 1, 3, 6, and 12 months postoperatively. One implant failed early in 1 patient. All of the other implants were in a good functional state throughout the study. The mean marginal bone loss after 1 year of follow-up was 0.3 mm (SD, 0.1) at center, 0.5 mm (SD, 0.1) at canine and 0.7 mm (SD, 0.2) at distal fixtures, respectively. Statistically, there was not significant differences among each sites(P>.05)The mean ISQ change after 1 year of follow-up was -1.05 (SD, 2.76) at center, -0.85 (SD, 2.59) at canine and -1.27 (SD, 2.18) at distal fixtures, respectively. This prospective pilot study showed that the use of CAD/CAM technology and flapless implant surgery may be considered reliable for fully edentulous mandible of patients.

Life-threatening airway obstruction after flapless implant placement in the anterior mandible

  • Kim, Jin-Hong;Park, Hee-Keun;Kim, Moon-Key;Kang, Sang-Hoon
    • Journal of the Korean Association of Oral and Maxillofacial Surgeons
    • /
    • v.38 no.5
    • /
    • pp.310-313
    • /
    • 2012
  • This paper reports a patient who had an airway obstruction caused by a hemorrhage of the mouth floor that occurred after she underwent flapless implantation in the region of the mandibular anterior teeth. The hemorrhage may have been caused by iatrogenic malpositioned fixture and patient's hypertension. The lingual periosteum was not dissected during the flapless procedure. Therefore, when hemorrhage occurred, the blood did not drain easily into the oral cavity but instead drained into the deep neck region, which might have been the cause of the airway obstruction.

Prosthetic rehabilitation with digital implant planning for a minimally invasive surgery approach (디지털 임플란트 플래닝을 통한 최소침습 보철수복 증례)

  • Jeong, Areum;Lee, Younghoo;Hong, Seoung-Jin;Paek, Janghyun;Noh, Kwantae;Pae, Ahran;Kim, Hyeong-Seob;Kwon, Kung-Rock
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.60 no.3
    • /
    • pp.283-292
    • /
    • 2022
  • For fixed prosthetic treatment using implants, implants must be placed in a suitable location for prosthetic treatment. During surgery, minimally invasive prosthetic restoration is possible using a flapless method using a surgical guide. The patient in this case was an 86-year-old male patient who wanted treatment due to discomfort when using conventional dentures. Due to systemic disease, the patient had difficulty using removable local dentures, so full dentures for the maxilla and fixed implants for the mandible were restored. Because there is a high risk of bleeding due to systemic disease, the implant was placed in a flapless method using a surgical guide. Finally, prostheses were fabricated with maxillary full denture and mandibular screw-retained zirconia, and this report shows satisfactory esthetic and functional recovery.

Need-to-knows about Digital Implant Surgery (디지털 가이드 수술의 이해와 임상적 적용)

  • Paek, Janghyun;Kwon, Kung-Rock;Kim, Hyeong-Seob;Pae, Ahran;Noh, Kwantae;Hong, Sung-Jin;Lee, Hyeon-jong
    • The Journal of the Korean dental association
    • /
    • v.56 no.11
    • /
    • pp.631-640
    • /
    • 2018
  • Nowadays computer-guided "flapless" surgery for implant placement using templates is gaining popularity among clinicians and patients. The advantages of this surgical protocol are its minimally invasive nature, accuracy of implant placement, predictability, less post-surgical discomfort and reduced time required for definitive rehabilitation. Aim of this study is to describe the digital implant protocol, thanks to which is now possible to do a mini-invasive static guided implant surgery. This is possible thanks to a procedure named surface mapping based on the matching between numerous points on the surface of patient's dental casts and the corresponding anatomical surface points in the CBCT data. With some critical points and needing an adequate learning curve, this protocol allows to select the ideal implant position in depth, inclination and mesio-distal distance between natural teeth and or other implants enabling a very safe and predictable rehabilitation compared with conventional surgery. It represents a good tool for the best compromise between anatomy, function and aesthetic, able to guarantee better results in all clinical situations.

  • PDF

Accuracy of computer-aided template-guided oral implant placement: a prospective clinical study

  • Beretta, Mario;Poli, Pier Paolo;Maiorana, Carlo
    • Journal of Periodontal and Implant Science
    • /
    • v.44 no.4
    • /
    • pp.184-193
    • /
    • 2014
  • Purpose: The aim of the present study was to evaluate the in vivo accuracy of flapless, computer-aided implant placement by comparing the three-dimensional (3D) position of planned and placed implants through an analysis of linear and angular deviations. Methods: Implant position was virtually planned using 3D planning software based on the functional and aesthetic requirements of the final restorations. Computer-aided design/computer-assisted manufacture technology was used to transfer the virtual plan to the surgical environment. The 3D position of the planned and placed implants, in terms of the linear deviations of the implant head and apex and the angular deviations of the implant axis, was compared by overlapping the pre- and postoperative computed tomography scans using dedicated software. Results: The comparison of 14 implants showed a mean linear deviation of the implant head of 0.56 mm (standard deviation [SD], 0.23), a mean linear deviation of the implant apex of 0.64 mm (SD, 0.29), and a mean angular deviation of the long axis of $2.42^{\circ}$ (SD, 1.02). Conclusions: In the present study, computer-aided flapless implant surgery seemed to provide several advantages to the clinicians as compared to the standard procedure; however, linear and angular deviations are to be expected. Therefore, accurate presurgical planning taking into account anatomical limitations and prosthetic demands is mandatory to ensure a predictable treatment, without incurring possible intra- and postoperative complications.