• Title/Summary/Keyword: Flammable materials

Search Result 134, Processing Time 0.026 seconds

Measurement and Prediction of Fire and Explosion Properties of n-Ethylanilne (노말에틸아닐린의 화재 및 폭발 특성치의 측정 및 예측)

  • Ha, Dong-Myeong
    • Korean Chemical Engineering Research
    • /
    • v.56 no.4
    • /
    • pp.474-478
    • /
    • 2018
  • For process safety, fire and explosion characteristics of combustible materials handled at industrial fields must be available. The combustion properties for the prevention of the accidents in the work place are flash point, fire point, explosion limit, and autoignition temperature (AIT) etc.. However, the combustion properties suggested in the Material Safety Data Sheet (MSDS) are presented differently according to the literatures. The accurate combustion properties are necessary to safely treatment, transportation and handling of flammable substances. In the chemical industries, n-ethylaniline which is widely used as a raw material of intermediate products and rubber chemicals was selected. For safe handling of n-ethyl aniline, the flash point, the fire point and the AIT were measured. The lower explosion limit (LEL)of n-ethylaniline was calculated using the lower flash point obtained in the experiment. The flash points of n- ethylaniline by using the Setaflash and Pensky-Martens closed-cup testers measured $77^{\circ}C$ and $82^{\circ}C$, respectively. The flash points of n-ethylaniline using the Tag and Cleveland open cup testers are measured $85^{\circ}C$ and $92^{\circ}C$, respectively. The AIT of the measured n-ethyl aniline by the ASTM E659 apparatus was measured at $396^{\circ}C$. The LEL of n-ethylaniline measured by Setaflash closed-cup tester at $77^{\circ}C$ was calculated to be 1.02 vol%. In this study, it was possible to predict the LEL by using the lower flash point of n-ethylaniline measured by closed-cup tester. The relationship between the ignition temperature and the ignition delay time of the n-ethylaniline proposed in this study makes it possible to predict the ignition delay time at different ignition temperatures.

Reliability of Combustion Properties of MSDS(Material Safety Data Sheet) of tert-Amylalcohol(TAA) (tert-Amylalcohol(TAA)의 물질안전보건자료(MSDS) 연소특성치의 신뢰도)

  • Ha, Dong-Myeong
    • Journal of the Korean Institute of Gas
    • /
    • v.23 no.6
    • /
    • pp.17-24
    • /
    • 2019
  • The combustion properties of the flammable substance used in industrial fields include lower/upper flash point, lower/upper explosion limit, autoignition temperature(AIT), fire point, and minimum oxygen concentration(MOC) etc.. The accurate assessment of these characteristics should be made for process and worker safety. In this study, tert-amylalcohol(TAA), which is widely used as a solvent for epoxy resins, oxidizers of olefins, fuel oils and biomass, was selected. The reason is that there are few researches on the reliability of combustion characteristics compared to other flammable materials. The flash point of the TAA was measured by Setaflash, Pensky-Martens, Tag, and Cleveland testers. And the AIT of the TAA was measured by ASTM 659E. The lower/upper explosion limits of the TAA was estimated using the measured lower/upper flash points by Setaflash tester. The flash point of the TAA by using Setaflash and Pensky-Martens closed-cup testers were experimented at 19 ℃ and 21 ℃, respectively. The flash points of the TAA by Tag and Cleveland open cup testers were experimented at 28 ℃ and 34 ℃, respectively. The AIT of the TAA was experimented at 437 ℃. The LEL and UEL calculated by using lower and upper flash point of Setaflash were calculated at 1.10 vol% and 11.95 vol%, respectively.

Consequence Analysis of the Fire & Explosion on the Flammable Liquid Handling Facility and LPG Station (제 4류 위험물 취급소 및 LPG 충전소의 화재$\cdot$폭발 피해 영향분석)

  • Lee Su-Kyung;Lee Chang-Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.3 no.2 s.7
    • /
    • pp.77-84
    • /
    • 1999
  • The XX company that is handling the class IV hazardous materials, located in Bu-Chon City and the LPG station in front of the XX company which is about 20 meters apart, was chosen as the standard model for this study In carrying out the consequence analysis, PHAST and Super-Chems were used for the study and utilizing the output of the simulation, we have evaluated the consequences throughout the probit analysis and explosion overpressure analysis. In case of Acetone, the effect distance of the damage on facilities-that is the result of radiation heat flux of $37.5kW/m^2$ by TNO model-is 68.51m by PHAST model and 40.93m by Super-Chem model. The risk assessment of the LPG station which is based on the explosion resulted as the analysis of the fire ball showed the diameter 125.2m, the height 206.2m and the duration 11.28sec and the effect distance for the radiant heat flux $37.5kW/m^2$ was 137.0m.

  • PDF

An Experimental Study on the Development of Lightweight Foamed Concrete as Sandwich Panel Core (샌드위치 패널 심재용 경량기포콘크리트 개발에 관한 실험적 연구)

  • Lee, Sang-An;Chun, Woo-Young;Ko, Kwan-Ho;Kim, Wha-Jung
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.557-560
    • /
    • 2008
  • This was done by analyzing the sandwich panels that are now widely used in construction work. Sandwich panels are used for diverse purposes in construction work worldwide. In Korea, polystyrene panels that have organic materials as their core material are used. These panels are thus very vulnerable to fire, with risks of core melting, sheet deformation, and hazardous gases. Accordingly, sandwich panels' fire-resistant or non-flammable properties must be secured. To solve these problems, the optimal mixing proportion of lightweight foamed concrete for the sandwich panel core was determined. A new method of doing this was introduced that is completely different from the existing method, wherein a foaming agent is added to realize lightweight concrete. For lightweight concrete, the foaming mechanisms via diverse chemical reactions were identified, H$_2$O$_2$ was added for heating in the reaction, and the concrete foaming was maximized. Through diverse experiments to determine the optimal mixing proportion of lightweight foamed concrete and to examine the filling characteristic of lightweight foamed concrete for sandwich panel cores using waste materials, the physical and mechanical properties of lightweight foamed concrete were examined.

  • PDF

Performance Comparison of Integrated Reactor with Steam Reforming and Catalytic Combustion using Anode Off-Gas for High Temperature Fuel Cells (고온용 연료전지 미반응 가스를 이용한 촉매연소-개질 통합 반응기의 성능 비교)

  • Ghang, Tae-Gyu;Sung, Hae-Jung;Lee, Sang-Min;Ahn, Kook-Young;Kim, Yong-Mo
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.22 no.6
    • /
    • pp.800-809
    • /
    • 2011
  • The reaction characteristics of an integrated reactor with steam reformer and catalytic combustor using anode offgas for high temperature fuel cells such as MCFC and SOFC have been experimentally investigated in the present study. The coupled reactor had a coaxial cylindrical shape, and the inner and the outer tube was packed with combustion catalysts and reforming catalysts, respectively. Thus, the endothermic steam reforming could proceed by absorbing heat from catalytic combustion of anode offgas. Results show that increasing inlet temperature and decreasing excess air ratio increased the reformer temperature, which led to the increase in $H_2$ yield. The reforming performance for SOFC conditions was better than that for MCFC conditions since the composition of flammable components became smaller for MCFC cases. Measured reformate composition under various test conditions correlated well with thermal equilibrium composition.

A Study on the Flammability and Combustion Risk of Biodiesel Mixture (바이오디젤 혼합물의 인화 및 연소 위험성에 관한 연구)

  • Kim, Ju Suk;Ko, Jae Sun
    • Journal of the Society of Disaster Information
    • /
    • v.17 no.1
    • /
    • pp.10-24
    • /
    • 2021
  • Purpose: The purpose of this study is to determine the dangers of biodiesel and general diesel mixtures currently used as alternative fuels by equipment (tag method and penski Marten method) and to determine the difference between flash point and combustion point (closed, open) according to test methods. It is intended to be used as a reference material for identification and evaluation of firecausing substances by confirming the risk of mixtures by comparative analysis and measurement, and establishing a risk assessment method for chemical substances. Method: Flash point test method and result treatment were tested based on ASTM and KS M mode, which are tag sealing and pen schematense test methods used as flash point and combustion point test methods for crude oil and petroleum products. The manufacturer of the equipment used in this experiment was a test equipment that satisfies the test standards of KS M 2010 with equipment produced by TANAKA of Japan. The flash point and combustion point were measured, and the flash point according to the test method of biodiesel and general diesel mixture ( Closed, open), and the ignition point of a mixture of biodiesel and general diesel was compared and analyzed for ignition risk compared with conventional diesel. Results: Looking at the experimental results, first, as an analysis of the risk of flammability of the mixture, the flash point of a substance containing 70% biodiesel was found to be about 92℃ based on general diesel with a flash point of 64.5℃, and gasoline and biodiesel or When the biodiesel mixture was synthesized, it was confirmed that the flash point tends to decrease. In addition, the difference between the flash point and the combustion point was analyzed as about 20 ~ 30℃, and when a small amount of gasoline or methanol was mixed, the flash point was lowered, but it was confirmed that the combustion point was similar to that of the existing mixture. Conclusion: In this study, in order to secure the effectiveness of the details of the criteria for judging dangerous materials in the existing Dangerous Materials Safety Management Act, and to secure the reliability and reproducibility of the judgment of dangerous materials, we confirm the criteria for judging the risk of the mixture through an experimental study on flammable mixtures. It will be able to provide reference data for experimental criteria for flammable liquids that are regulated in the field. In addition, if this study accumulates know-how on experiment by test method, it is expected that it can be used as a basis for research on risk assessment and research on dangerous goods.

Effect of Varying Excessive Air Ratios on Nitrogen Oxides and Fuel Consumption Rate during Warm-up in a 2-L Hydrogen Direct Injection Spark Ignition Engine (2 L급 수소 직접분사 전기점화 엔진의 워밍업 시 공기과잉률에 따른 질소산화물 배출 및 연료 소모율에 대한 실험적 분석)

  • Jun Ha;Yongrae Kim;Cheolwoong Park;Young Choi;Jeongwoo Lee
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.3
    • /
    • pp.52-58
    • /
    • 2023
  • With the increasing awareness of the importance of carbon neutrality in response to global climate change, the utilization of hydrogen as a carbon-free fuel source is also growing. Hydrogen is commonly used in fuel cells (FC), but it can also be utilized in internal combustion engines (ICE) that are based on combustion. Particularly, ICEs that already have established infrastructure for production and supply can greatly contribute to the expansion of hydrogen energy utilization when it becomes difficult to rely solely on fuel cells or expand their infrastructure. However, a disadvantage of utilizing hydrogen through combustion is the potential generation of nitrogen oxides (NOx), which are harmful emissions formed when nitrogen in the air reacts with oxygen at high temperatures. In particular, for the EURO-7 exhaust regulation, which includes cold start operation, efforts to reduce exhaust emissions during the warm-up process are required. Therefore, in this study, the characteristics of nitrogen oxides and fuel consumption were investigated during the warm-up process of cooling water from room temperature to 88℃ using a 2-liter direct injection spark ignition (SI) engine fueled with hydrogen. One advantage of hydrogen, compared to conventional fuels like gasoline, natural gas, and liquefied petroleum gas (LPG), is its wide flammable range, which allows for sparser control of the excessive air ratio. In this study, the excessive air ratio was varied as 1.6/1.8/2.0 during the warm-up process, and the results were analyzed. The experimental results show that as the excessive air ratio becomes sparser during warm-up, the emission of nitrogen oxides per unit time decreases, and the thermal efficiency relatively increases. However, as the time required to reach the final temperature becomes longer, the cumulative emissions and fuel consumption may worsen.

An Experimental Study on Fire Spreading External Wall of Buildings Using Dry Construction Method (건식공법을 이용한 건축물의 외벽 화재 확산의 실험적 연구)

  • Park, Jung-Woo;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.32 no.4
    • /
    • pp.75-85
    • /
    • 2018
  • The Grenpell tower fire in England in June of 2016 is a representative example of damage caused by a vertical fire spreading through external insulation. Organic insulation materials, which are widely used in external insulation, have the disadvantage that they have good insulation performance but are vulnerable to fire. Aluminum composite panels are used as exterior wall finishing materials, and plastics used in aluminum are regarded as the cause of vertical fire spread. Due to the steel frame used to secure the aluminum composite panel to the outer wall, a cavity is formed between the outer wall and outer wall finish. When a fire occurs on the outer wall, the flammable outer wall as well as the flame generated from the heat-insulating material spreads vertically through the cavity, resulting in damage to people and property. In Korea, material unit performance tests are carried out by the Ministry of Land, Infrastructure and Transport notice 2015 - 744. However, in the UK, the BS 8414 test is used to measure the vertical fire spreading time on the outer wall in real scale fire tests. In this study, the risk of external wall fire was evaluated in an actual fire by conducting a real scale wall fire test (BS 8414), which was carried out in Europe, using aluminum composite panels of semi-noncombustible materials suitable for current domestic standards. The purpose of this study was to confirm the limitations of material unit evaluation of finishing materials and to confirm the necessity of introducing a system to prevent the spread of outer wall fire through an actual scale fire test.

Estimation of Sodium Hydroxide Waste Origin-Destination Matrices for Preventing Hazardous Material Transportation Disasters

  • Kim, Geun-Young;Jung, Tae-Hwa;Kim, Sang-Won
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.9 no.1
    • /
    • pp.73-79
    • /
    • 2009
  • Hazardous materials (HazMats) are substances that are flammable, explosive, toxic, or harmful, if released into the environment. Since the transportation of HazMats increases in many developed countries, HazMat transportation has the key function in the process of HazMat usage to trace information of production, storage, shipment, usage, and waste disposal. The Korean Ministry of Environment (KMOE) and the National Emergency Management Agency (NEMA) have developed many laws, regulations, and standards for hazardous materials. However, the Korean HazMat laws, regulations, and standards do not guarantee accurate information of HazMat origin-destination (O-D) shipments, though the HazMat O-D movement is the critical information in safety and security of HazMat transportation. The objectives of this research are: (1) to investigate emerging and recurrent issues in Korean HazMat transportation, and (2) to develop the estimation method of O-D matrices for hazardous materials under limited data sets. The sodium hydroxide waste shipment among forty candidate HazMats is selected as the sample research case. The growth-factor method is applied to estimate the 2005 O-D matrix of sodium-hydroxide waste shipment. The column-and-row factoring process is used to calibrate the estimated sodium-hydroxide O-D matrix. The result shows the applicability of the O-D estimation process for hazardous materials. The Sodium Hydroxide Waste Origin-Destination Matrix is obtained to trace routes and paths of the Sodium Hydroxide transportation.

Spray Characteristics of In-Rack Sprinkler Heads (인랙스프링클러 헤드의 살수 특성)

  • Kim, Jong Hoon;Joung, Woo In;Myoung, Sang Youb;Jeong, Keesin;Kim, Woon Hyung
    • Fire Science and Engineering
    • /
    • v.31 no.3
    • /
    • pp.54-62
    • /
    • 2017
  • The aim of this study is to find out the water spray features of in-rack sprinklers for rack storage. This study conducted cold water flow test, measurement of spray angle and densities by angles for sprinkler head manufactured by a Korean company and a U.S. company. Korean sprinkler head had a wide angle of water spary. The water spray angle of a U.S. sprinkler head was narrow compared to the Korean sprinkler. In comparison of the Korean head with U.S. head of the same K80, the Korean head can send water to parts that are difficult to directly spray, but the spraying density by angle was low. U.S. head can send more water than Korean head at a narrow angle. In conclusion, for flammable materials placed in two or more rows in a rack storage, a zigzag arrangement with face sprinklers will be effective.