• Title/Summary/Keyword: Flammable gas monitoring system

Search Result 6, Processing Time 0.018 seconds

A Study on the Effectiveness of Flammable Gas Monitoring System in the Cargo Pump Room of Tanker

  • Kim, Mann-Eung;Lee, Kyoung-Woo;Lee, Young-Ho
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.3
    • /
    • pp.455-460
    • /
    • 2008
  • The flammable gas monitoring system is to be provided in cargo pump rooms of tankers in accordance with the requirements of SOLAS regulations, and flammable gas detectors are to be arranged in a proper position. In this paper, simulation tests and CFD analysis are carried out under the actual ventilation conditions of pump rooms in the ship in service. Based on the results, a new guidelines for an arrangement of flammable gas detectors are suggested.

A Study on Optimal Ventilation Design for Gas Boxes Installed in Semiconductor Manufacturing Equipment Handling Flammable Liquids (인화성 가스를 취급하는 반도체 제조장비에 설치된 가스박스 최적 환기 설계에 대한 연구)

  • Gyu Sun Cho;Sang Ryung Kim;Won Baek Yang
    • Journal of the Korean Institute of Gas
    • /
    • v.27 no.1
    • /
    • pp.63-69
    • /
    • 2023
  • Although Korea is the world's No. 1 semiconductor producing country, most studies are conducted with risk assessment for simple material risks due to the closedness of the site for industrial protection. In terms of industrial safety, a monitoring system such as a gas detector to determine the leakage of hazardous substances has been established, but research on effectively discharging harmful gastritis substances in case of leakage has only recently begun. Semiconductor manufacturing facilities (gas boxes) where a large amount of flammable materials are handled are currently being safety managed by using a gas detector and blocking the air inlet. It is difficult to dilute in a short time in case of leakage of flammable substances. Therefore, in this study, based on various criteria, the size of the duct according to the size of the gas box is determined and the appropriate size of the air inlet is studied to minimize the exhaust performance requirement without exposing hazardous chemicals to the outside in the event of a flammable leak. We want to do an optimal exhaust design.

Surveillance System For Underground Power Transmission Lines (초고압 지중선로 감시시스템 연구)

  • Hahn, K.M.;Lee, K.C.;Kim, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 1993.07b
    • /
    • pp.618-620
    • /
    • 1993
  • This system using optical fiber provides various information about underground tunnel and power transmission lines-atmospheric temperature, humidity, oil pressure, flammable gas, cable behavior, and so on. To transmit various data and to keep reliability, optical MUXs are adopted. User can easily operate monitoring software by using GUI.

  • PDF

Fire Monitoring System for Traditional Markets based on Digital Twin-IoT Sensing (디지털 트윈 & IoT Sensing 융합 기반 전통시장 화재 모니터링 시스템)

  • Jung-Taek Hong;Kyu-Hyup Lee;Jin-Woo Song;Seo-Joon Lee;Young-Hee Chang;Soon-Wook Kwon
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.26 no.6_3
    • /
    • pp.1251-1258
    • /
    • 2023
  • Traditional markets are infrastructure with facilities and characteristics of very high population density. Recently, arcades have been installed through traditional market modernization policies, and aging infrastructure has been repaired. However, gas and electrical facilities of traditional markets cannot be easily replaced because of its high density. And because regular inspections are not conducted, management of facilities is on very poor condition. In addition, when a fire occurs in a traditional market, the fire easily spreads to nearby stores and is likely to spread to a large fire because of a lot of highly flammable substances. Smoke detectors and heat detectors are installed in most traditional markets to monitor fires, but malfunctions are frequent due to the nature of smoke detectors and heat detectors, and network facilities are not properly maintained. Therefore, in this study, gas detection sensors and flame detectors are additionally installed in Gwangmyeong Traditional Market, and a digital twin-based traditional market fire monitoring system is implemented in conjunction with existing sensors in the market's 3D model. With this digital twin based fire monitoring system, we can reduce the malfunctions of fire detect sensors, and can easily guide the evacuation route.

Development of a Raman Lidar System for Remote Monitoring of Hydrogen Gas (수소 가스 원격 모니터링을 위한 라만 라이다 시스템 개발)

  • Choi, In Young;Baik, Sung Hoon;Park, Nak Gyu;Kang, Hee Young;Kim, Jin Ho;Lee, Na Jong
    • Korean Journal of Optics and Photonics
    • /
    • v.28 no.4
    • /
    • pp.166-171
    • /
    • 2017
  • Hydrogen gas is a green energy sources because it features no emission of pollutants during combustion. But hydrogen gas is very dangerous, being flammable and very explosive. Hydrogen gas detection is very important for the safety of a nuclear power plant. Hydrogen gas is generated by oxidation of nuclear fuel cladding during a critical accident, and leads to serious secondary damage in the containment building. This paper discusses the development of a Raman lidar system for remote detection and measurement of hydrogen gas. A small, portable Raman lidar system was designed, and a measurement algorithm was developed to quantitatively measure hydrogen gas concentration. To verify the capability of measuring hydrogen gas with the developed Raman lidar system, experiments were carried out under daytime outdoor conditions by using a gas chamber that can adjust the hydrogen gas density. As results, our Raman lidar system is able to measure a minimum density of 0.67 vol. % hydrogen gas at a distance of 20 m.