• 제목/요약/키워드: Flame ionization detector

검색결과 115건 처리시간 0.025초

Effect of Bile Salt on the Pharmacokinetics of Bretylium in the Rat (I) - Increased Lipophiiicity of Bretylium by Ion-Pair Complexation with Taurodeoxycholate -

  • Shim, Chang-Koo;Chung, Suk-Jae;Lee, Jeong-Uk;Lee, Min-Hwa;Kim, Shin-Keun
    • Archives of Pharmacal Research
    • /
    • 제9권2호
    • /
    • pp.111-114
    • /
    • 1986
  • Bretylium tosylate is a quaternary ammonium compound used for the treatment of ventricular fibrilation in humans. It is advantageous to other cationic compound in the study of biliary excretion in that negligible amount is bound to plasma protein and metabolite is not likely is to be formed. Some researchers reported that the formation of ion-pair complex caused to increase the lipothilicity of cationic compound. The partition of bretylium between water and organic phase was increased with the addition of sodium taurodeoxycholate. Also sensitive gas chromatographical assay procedure using flame ionization detector was studied. This procedure can detect as low as 0.1 mg/ml using 0.1 ml biological sample, but contamination by previous injection is the major problem of this method.

  • PDF

열탈착/GC/FID를 이용한 B, T, X 분석의 정확도 및 정밀도 평가 (A Study on Evaluation of Accuracy and Precision on B, T, X Analysis Using Thermal Desorption/Gas Chromatograph/Flams Ionization Detector)

  • 박정근;유기호
    • 한국대기환경학회지
    • /
    • 제16권3호
    • /
    • pp.265-275
    • /
    • 2000
  • By using thermal desorption/gas chromatograph/flame ionization detector(TD/GC/FID), this study was carried out to evalute an accuracy and a precision on Benzene(B), Toluene(T), o-Xylene(X) analysis in an industrial hygiene laboratory. Limits of detection of TD/GC/FID on B, T, X were showed 13.75ng/sample or less. For the accuracy of the method by concentration levels, overall bias was showed 7.7% as an absolute value, and the pooled coefficient of variation showed 3.51%. For the precision on repeatability of peak area and retention time between within-run and between-run of analytical system, it is showed the results of within-run gave better than those of between-run. Also the accuracy by sorbents(Tenax TA and Chromosorb 106)was evaluated, and the precision on reproducibility between MDHS72 and this study was compared. It is showed it is possible for TD/GC/FID to evaluate accurately B, T, X concentration levels of less than 1ppm at indoor or outdoor of workplaces in Korea.

  • PDF

참기름의 휘발성 향기성분의 특성 (Characteristics of the Volatile Flavor Compounds in the Oil from Roasted Sesame Seed)

  • 하재호
    • 한국식품과학회지
    • /
    • 제29권6호
    • /
    • pp.1101-1104
    • /
    • 1997
  • 참기름의 향기성분을 dynamic headspace법으로 포집 한 다음 FID와 OD가 장착된 GC-MSD로 분석 하였다. 주요 향기성분으로는 methylpyrazine, acetic acid, 2-furan carboxaldehyde 및 2-furanmethanol 등 20종이 분리동정되었다. Sniffing test 결과 pyrazine류와 2-furan carboxaldehyde은 참기름의 좋은 향을 나타내었고 acetic acid와 2-furanmethanol은 참기름의 좋지않은 냄새로 밝혀졌다.

  • PDF

활성탄관을 사용하여 포집한 작업환경 공기중 아크릴아마이드의 분석법 (Simple Analytical Method for Acrylamide in the Workplace Air Adsorbed by Charcoal Tube)

  • 양정선;이미영;박인정;강성규
    • 분석과학
    • /
    • 제11권2호
    • /
    • pp.139-144
    • /
    • 1998
  • 아크릴아마이드를 생산하는 공장에서, 근로자가 노출될 가능성이 있는 아크릴아마이드의 양을 평가하기 위하여, 작업환경 시료의 포집과 이에 대한 탈착, 분석조건을 검토하였다. 작업 환경 중 시료 채취를 위한 흡착제로서 활성탄관을 사용하고, 이를 아세톤으로 추출하였을 때 87%의 탈착효율을 나타내었다. 불꽃이온화 검출기가 부착된 가스크로마토그라피로 분석한 경우 검출한계는 0.814 mg/L였고, 이를 40L의 작업환경 공기중 농도로 환산하면 $0.0203mg/m^3$이다. 따라서 산업보건 관련 실험실에 일반화 되어있는 불꽃이온화 검출기(Flame Ionization Detector, FID)를 사용하여도, 아크릴아마이드 허용농도 $0.3mg/m^3$(OSHA, PEL) 내외의 시료를 적절한 감도로 분석이 가능하다. 그러므로 기존의 분석방법으로 알려진 질소, 인 검출기(Nitrogen Phosphorous Detector, NPD)를 사용하지 않아도 아크릴아마이드를 신속하고 경제적으로 분석할 수 있을 것으로 생각된다.

  • PDF

한국산 개암종실의 중성지질 조성에 관한 연구 (Studies on the Neutral Lipid Components of Korean Hazel Nut)

  • 김미란;고영수;정보섭
    • 약학회지
    • /
    • 제25권4호
    • /
    • pp.181-186
    • /
    • 1981
  • Compositions of neutral lipid of the hazel nut (Corylus heterophylla Fischer var. thumbergii Blume, Betulaceae) produced in Korea were analyzed by thinchrography (Iatrosoan TH-10 type), which was equipped with a flame ionization detector. The neutral lipid components were nearly separated of the basis of their degree of unsaturation by employing the chromatography on silica gel sintered rod impregnated with 12.5% silver nitrate and it was noted that triglyceride was the major lipid components of Korean hazel nut. The triglyceride compositions were trilinolenin 10.63, trilinolein 18.01, triolein 42.24, tripalmitin 17.57 and tristearin 11.55% by thinchrographic analysis.

  • PDF

스파크플러그 주위의 HC 농도 측정 및 연소특성 분석 (Measurement of HC Concentration near Spark Plug and Combustion Analysis)

  • 조한승;송해박;이종화;이귀영
    • 한국자동차공학회논문집
    • /
    • 제6권2호
    • /
    • pp.212-219
    • /
    • 1998
  • Unburned hydrocarbon is a key contributor to both the fuel economy and emissions of automotive engine. Cyclic variation of HC emission is of importance, especially during throttle transients. The real time measurement of hydrocarbon is particularly important to obtain a better understanding of the mechanisms for combustion and emissions, especially during cold start and throttle transient condition. This paper reports the cycle resolved measurement technique of unburned hydrocarbons to quantify rapid changes of in-cylinder concentration in the vicinity of spark plug by using the Fast Response Flame Ionization Detector(FRFID). While this instrument actually measures fuel concentration, its results can be indicative of the AFR behaviour. In order to understand the rapid change of hydrocarbons with cylinder pressure, it is necessary to study the response time delay of the system, including the time associated with gas transportation to FID. And signal from FRFID is correlated with cylinder pressure data to relate changes in mixture preparation to the classic analysis, such as indicated mean effective(IMEF) and ignition delay, etc.

  • PDF

저온열탈착기술을 이용한 에틸렌 및 저분자 탄화수소 분석방법 연구 (A Study of Analytical Method for Ethylene and Low Weight Hydrocarbons (LWHC) using Thermal Desorption and Gas Chromatography-Flame Ionization Detector with (TD-GC-FID))

  • 김보원;김기현;김용현;안정현
    • 한국대기환경학회지
    • /
    • 제30권1호
    • /
    • pp.77-87
    • /
    • 2014
  • In this study, an experimental approach to measure a suite of low weight hydrocarbons was investigated with an emphasis on ethylene (EL) along with many others (ethane (EA), propane (PA), propylene (PL), n-butane (BA), acetylene (AL), methyl acetylene (ML)). Their concentrations were quantified using GC-FID system equipped with thermal desorption (TD) system. The TD-based analysis was conducted using both Link Tube/Thermal Desorber (LT/TD) method and Modified Injection through a Thermal Desorption (MITD) method. The results of these analyses were evaluated in a number of respects. The system allowed the detection of all compounds except methane with the mean response factor (RF) of 10.28 (EA) to 11.94 (PL). The method detection limits of target compounds were seen in the range of 0.027 (ML) to 0.146 ng (BA). The emission flux of some environmental samples (fruits), when measured using a small flux chamber system, fell in the range of 0.14 (AL: Kiwi) to $181ng{\cdot}g^{-1}{\cdot}hr^{-1}$ (EL: Apple Peel). The results of this study confirm that the experimental approach developed in this study allows to accurately measure emissions of low weight hydrocarbons (LWHC) like ethylene from various natural and man-made source processes.

LPG와 가솔린 연료의 차량 배출가스 특성에 대한 비교 연구 (A Study on the Exhaust Emission of LPG and Gasoline Vehicle)

  • 정성환;한상명
    • 한국자동차공학회논문집
    • /
    • 제10권5호
    • /
    • pp.23-28
    • /
    • 2002
  • As the interest on the air pollution is gradually rising up at home and abroad, automotive industries have been working on the exhaust emission reduction from vehicles through a lot of approaches, which consist of new engine design, innovative aftertreatment systems, and using clean fuels. Methanol, ethanol, LNG, LPG, H2, reformulated gasoline are generally recognized as the clean fuel. Since the low price policy of government on LPG has expanded its vehicle market recently, there is concern of the exhaust emission of LPG vehicle. In this paper, we studied the value of LPG fuel as a clean fuel by comparing the results of the exhaust emission from LPG and Gasoline fueled vehicles, and discussed its limitation of LPG vehicle with mixer type as a fuel supply system. FTIR was used to understand the difference of exhaust emission components of LPG and Gasoline fueled vehicles.

기체 Chromatograph를 이용한 체액내 Volatile Free Acid의 분석연구 (Volatile Free Acid Profiling of Body Fluids by Gas Chromatography)

  • 김경례;한미경
    • 약학회지
    • /
    • 제32권1호
    • /
    • pp.6-13
    • /
    • 1988
  • A gas chromatographic method is described for the determination of volatile free acids(VFAs) in body fluids. VFAs were trace enriched from body fluids by liquid-solid extraction using Chromosorb P as the solid sorbent and ether as the eluant. The enriched VFAs were injected in splitless injection mode onto a HP-20M fused silica capillary column. The flame ionization detector was used as the detector. The present method was applied to the profiling of VFAs in body fluids from patients suffering from the infectious disease, hepatitis. The VFAs concentrations were high in saliva of hepatitis patients and isobutyric acid detected in sera of hepatitis patients compared to healthy subjects.

  • PDF