• Title/Summary/Keyword: Flame Temperature

Search Result 1,300, Processing Time 0.029 seconds

Experimental Study on the Combustion Characteristics of Magnesium using Infrared Thermography and FE-SEM (적외선 열화상법 및 FE-SEM을 활용한 마그네슘 연소특성에 관한 실험적 연구)

  • Lee, Jun-Sik;Nam, Ki-Hun
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.6_2
    • /
    • pp.927-934
    • /
    • 2020
  • Magnesium powder has been widely used in various industries because it is light weight and extremely high mechanical strength including aeronautics and chemicals. However, magnesium, as a combustible metal, poses serious safety issues such as fires and explosions if it is not managed properly. Especially, magnesium's max adiabatic flame temperature is 3,340℃ and it is impossible to extinguish it by using water, CO2 and Halonagents. The aim of this study is to identify the combustion characteristics of magnesium powder. We carried out a combustion experiment, using 1 kg of magnesium (purity > 99 %, particle < 150 ㎛). The features of the magnesium burning process were scrutinized using infrared thermal image analysis. Also, a field-emission scanning electron microscope (FE-SEM) were used employed to analyze particulate composites and properties. It concludes the significant tendency of magnesium fire and light, combustion carbide's particle characteristics. This study contributes to make better prevention and response manners to magnesium fires, as well as fire investigation measures.

Characteristic Property of Combustion and Internal Ballistics of Triple-Based Propellant according to Particle Size of RDX (RDX 입도에 따른 다기추진제의 연소 및 강내탄도 특성)

  • Soojung Son;Wonmin Lee;Woojin Lee;Daegeon Kim
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.27 no.3
    • /
    • pp.428-435
    • /
    • 2024
  • The important factors in the design of the gun propellant are impetus, flame temperature and pressure. In this paper, we considered a nitrocellulose based propellant composition that replaced sensitive NG(Nitroglycerin) with RDX(Cyclotrimethylenetrinitramine) and DEGDN(Diethylene glycol dinitrate) which high energy and low sensitivity. Particle size and content of RDX are the two main factors that affect the burning stability of RDX-based propellants. Among them, the characteristics of the propellant according to the particle size of RDX were confirmed. The relative combustion rate(R.Q., Relative Quickness) of the propellant changed according to the RDX particle size, and internal ballistics of properties of propellant were also varied. The particle size of RDX can be confirmed as a major factor in the combustion and internal ballistics characteristics of the propellant.

COMBUSTION VISUALIZATION AND EMISSIONS OF A DIRECT INJECTION COMPRESSION IGNITION ENGINE FUELED WITH BIO-DIESOHOL

  • LU X.;HUANG Z.;ZHANG W.;LI D.
    • International Journal of Automotive Technology
    • /
    • v.6 no.1
    • /
    • pp.15-21
    • /
    • 2005
  • The purpose of this paper is to experimentally investigate the engine pollutant emissions and combustion characteristics of diesel engine fueled with ethanol-diesel blended fuel (bio-diesohol). The experiments were performed on a single-cylinder DI diesel engine. Two blend fuels were consisted of $15\%$ ethanol, $83.5\%$ diesel and $1.5\%$ solublizer (by volume) were evaluated: one without cetane improver (E15-D) and one with a cetane improver (E15-D+CN improver). The engine performance parameters and emissions including fuel consumption, exhaust temperature, lubricating oil temperature, Bosch smoke number, CO, NOx, and THC were measured, and compared to the baseline diesel fuel. In order to gain insight into the combustion characteristics of bio-diesohol blends, the engine combustion processes for blended fuels and diesel fuel were observed using an Engine Video System (AVL 513). The results showed that the brake specific fuel consumption (BSFC) increased at overall engine operating conditions, but it is worth noting that the brake thermal efficiency (BTE) increased by up to $1-2.3\%$ with two blends when compared to diesel fuel. It is found that the engine fueled with ethanol-diesel blend fuels has higher emissions of THC, lower emissions of CO, NOx, and smoke. And the results also indicated that the cetane improver has positive effects on CO and NOx emissions, but negative effect on THC emission. Based on engine combustion visualization, it is found that ignition delay increased, combustion duration and the luminosity of flame decreased for the diesohol blends. The combustion is improved when the CN improver was added to the blend fuel.

Effects of Design and Material Change of Firefighter Station Uniform on Thermal Physiological and Subjective Responses (소방 기동복의 디자인과 소재 변화가 착용자의 온열생리 반응 및 주관적 감각에 미치는 영향)

  • Kim, Hee-Eun;Kim, Seong-Suk;Son, Su-Young
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.44 no.4
    • /
    • pp.776-787
    • /
    • 2020
  • This study investigated physiological and subjective responses to different types of firefighter station uniforms made with various designs and materials. Six healthy males participated in this study that consisted of 20 min of rest, 30 min of treadmill exercise, and 30 min of recovery in a hot and humid environment (34℃ and 65%RH). The experimental clothing conditions were as follows. 1) a fitted T-shirt and trouser made of 100% polyester (FC-Uniform), and 2) flame retardant T-shirts made of acrylic and cotton as well as trousers with aramid and polyester, designed for overfitting (Control). There were no significant differences in the body temperature, and sweat rate between the two conditions; however, the heart rate with the FC-Uniform was significantly lower than Control (p=.025). The clothing microclimate temperature at the chest of the FC-Uniform was significantly lower than the Control (p=.037), and a difference of 1℃ was maintained until the recovery was complete. There were no significant differences in the subjective responses; however, participants experienced a humidity sensation faster with FC-Uniform in the recovery phase. The results indicate that changes in the design and material of firefighter station uniforms may have a positive influence on reducing the thermal stress of firefighters.

A Study on the Ignition Delay Effect by Flame-Resistance Paint Treatment (방염 처리에 따른 화재지연 효과 연구)

  • Oh, Kyu-Hyung;Kim, Hwang-Jin;Lee, Sung-Eun
    • Fire Science and Engineering
    • /
    • v.23 no.2
    • /
    • pp.111-116
    • /
    • 2009
  • 17 kinds of fire resistant paint which are currently used were painted on the MDF(middle density fiber board), which suitable to the regulation of Fire Service Act. And we investigate a ignition delay effect under a exposure condition of radiative heat of fire. Radiative heat flux was controlled from $10kW/m^2$ to $30kW/m^2$ using the cone heater. Ignition time, ignition type and surface temperature of the sample were measured. Based on the experimental result, critical heat flux of the fire resistant paint treated sample was $10kW/m^2$ and there were no ignition delay effect above the $30kW/m^2$. And it was found that it will be difficult to expect the fire resistant effect above $400^{\circ}C$ of sample surface temperature.

Performance Test of A Reverse-Annular Type Combustor (TS2) for APU (보조동력장치용 환형 역류형 연소기 (TS2) 성능 시험)

  • Ko, Young-Sung;Han, Yeoung-Min;Lee, Kang-Yeop;Yang, Soo-Seok;Lee, Dae-Sung
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.6
    • /
    • pp.805-810
    • /
    • 2002
  • Development of a small gas-turbine combustor for 100㎾ class APU(Auxiliary Power Unit) has been performed. This combustor is a reverse-annular type and has a tangential swiller in the liner head to improve the fuel/air mixing and flame stability. Three main and three pilot fuel injectors of the simplex pressure-swirl type are used. The performance target at the design condition includes a turbine inlet temperature of l170k, a combustion efficiency of 99%, a pattern factor of 30%, and an engine durability of 3000 hours. Under developing the combustor, we conducted the performance test of our first prototype(TS1) with some variants. As a result of the test, the performance targets of the combustor are satisfied except that the pattern factor is about 4% higher than the target value. Therefore, the second prototype(TS2) was redesigned and the performance test was conducted with the critical focus on the pattern factor and the exit mean temperature. We adopted TS2 four variants to check the improvement of the pattern factor. As a result, the pattern factors of several variants were satisfied with the performance target. Finally, the TS2A variant was chosen as a final combustor fur our APU model.

Synthesis and Properties of Polybenzoxazole Precursors having Oligo(oxy ethylene) pendant (Oligo(oxy ethylene) pendant를 갖는 PBO 전구체의 합성 및 특성)

  • Lee, Eung-Jae;Yoon, Doo-Soo;Bang, Moon-Soo;Choi, Jae-Kon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.14 no.5
    • /
    • pp.2550-2558
    • /
    • 2013
  • Poly(o-hydroxyamides)(PHAs) copolymers having oligo(oxy ethylene) pendant in the main chain were synthesized by solution polycondensation reaction at low temperature. Copolymer precursors were studied by fourier transform infrared(FT-IR), differential scanning calorimeter(DSC), thermogravimetric analyzer(TGA), universal testing machine(UTM) and limited oxygen index(LOI). The inherent viscosities of the PHAs measured at $35^{\circ}C$ in DMAc or DMAc/LiCl solution were in the range of 0.74~1.42 dL/g. Solubility of the precursors with higher oligo(oxy ethylene) unit was increased, but the PBOs were nearly insoluble in a variety of solvents. The degradation temperature of the copolymer precursors was recorded in the ranges of $408{\sim}664^{\circ}C$ in nitrogen and char yields showed 13~59% values at $900^{\circ}C$. The mechanical properties and flame retardancy of copolymer precursors decreased with higher oligo(oxy ethylene) unit.

The Characteristics of Combustion for Living Leaves in Quercus variabilis with Monthly Seasonal Variations (굴참나무 생엽의 월별 연소특성에 관한 연구)

  • Park, Young-Ju;Oh, Jin-Youl;Lee, Si-Young;Lee, Hae-Pyeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.10 no.3
    • /
    • pp.85-90
    • /
    • 2010
  • In this study, we have examined the monthly combustion characteristics of Quercus variabilis, a representing Quercus Spp. in Korea, using its living leaves over the period of from June to October. As a result, we were able to identify that their moisture content was about 114%~155%. The leaves of Quercus variabilis collected in October showed the lowest moisture content and nonflaming ignition temperature. The leaves of July showed the fastest flaming ignition time of 27s while those from September showed the longest persistence of flame with 105s, and also showed the highest total heat release amount. There was a noticeable difference in each month of the above period regarding total heat release amount and total smoke release amount with a gradual increase from June to October. The maximum smoke density was a bit higher in October leaves but there was no significant monthly difference. In addition, July leaves were shown to reach the maximum value in the shortest time of 795s.

Fabrication of electrical heating mold core and evaluation of injection-molded parts by various mold heating methods (전열을 이용한 금형가열코어의 제작 및 이를 이용한 성형품의 제조와 평가)

  • Kim Dong-Hak;Ryu Ji-Won;Son Young-Gon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.7 no.4
    • /
    • pp.738-742
    • /
    • 2006
  • In this study we developed the electrical heating mold core by applying three different heating methods. In order to find out the optimal heating method, we observed the temperature profiles with time. We also injection-molded the parts by the heating methods and investigated the shrinkage ratio, density, surface roughness and weld-lines. The temperature rise time and cycle time showed the promising results for commercial applications(the rise time is $130^{\circ}C$/14sec, the cycle time is 55sec). By comparing with the conventional and gas flame heating method, the parts by this method were proven to have good qualities. The shrinkage ratio reduced by 5.1%, the density increase by 2.66%, the smoothness increased about 3 times, and the weld-line did not observed by naked eyes.

  • PDF

A Study for the Fire Analysis and Igniting Cause of Freezing Protection Heating Cables (동파방지열선 화재 흔적분석과 발화원인 연구)

  • Lee, Jung Il;Ha, Kag Cheon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.3
    • /
    • pp.15-20
    • /
    • 2018
  • There have been a number of major fatal fire accidents in Korea recently. The number of fires in 2017 were 44,178, which is not only increasing number of fires but also increasing in casualties. Particularly, the fire at Jecheon Sports Center, which suffered many casualties, is expected to have a huge impact. The cause of the fire has not been determined yet, but heat waves on the ceiling have also been pointed out. As such, the copper heating waves, which are used as a preventive measure against damage of pipes due to freezing of pipes, etc., always have a fire hazard. To determine the possibility of a flame-resistant heated fire, a positive electric cable product was used to artificially ignite and analyze the results. In case of a short circuit, the external covering of the positive electric cable is damaged, but not short circuit unless the heating material surrounding the wire is damaged. Due to the characteristics of heating cable for preventing copper waves, the chances of insulation becoming more severe due to moisture and temperature changes are higher than normal wires. If the internal heating system is carbonized by insulating deterioration without damage to the outer coating, it is likely to cause trekking, to form a winding loop in the heating materials, and to cause short circuit in the heated materials. For the positive temperature line, if the middle is shorted, the current continues to flow to the short circuit unless the breaker disconnects. Consequently, a heated fire that does not cut off the power immediately may leave multiple marks or cuts.