• 제목/요약/키워드: Flame Detector

검색결과 194건 처리시간 0.024초

UV 화재감지장치 개발 (The development of UV falme detector)

  • 권오승;정창기;이복영
    • 방재기술
    • /
    • 통권28호
    • /
    • pp.48-54
    • /
    • 2000
  • The technique detects radiant energy form a flaming fire of fuels contained carbonaceous material can be applied to fast growing fires. This technique applied detectors are ultimately effective when early detecting fire alarm system is required or the smoke and heat detectors can not applied. In Korea Fire regulation, a flame detector should be install in case that the installation height is higher than 20[m], chemical plant, hangar refinery. Therefore it is really necessary that a flame detector has to be developed as soon as possible. With foundation technique of flame detector, ideal sensing element and stable circuit design, a trial UV flame detector is manufactured. The stable and reliable technique of flame detector is established through the repeateed perfomance test and modification. An early detecting fire alarm device is developed through the modification, supplement of the structure and circuit. Results of the R & D for the manufacture of an excellent flame detecting device is carried out with the establishment of technique for the mass production and the qualified manufacturing process.

  • PDF

UV-IR 복합형 화재감지장치 개발 (The Development of UV-IR Combination Flame Detector)

  • 이복영;권오승;정창기;박상태
    • 한국안전학회지
    • /
    • 제16권1호
    • /
    • pp.1-8
    • /
    • 2001
  • All objects emit thermal radiation and this radiation is the basis of the techniques used to detect flames. The usual phenomena occurring in the initial stage of the fire are generally invisible products of a combustion and visible smoke. Liquid or gaseous materials do not undergo a smoldering stage so that fires develop very rapidly. Also, the heat generated by the initial flames is usually not sufficient to activate a heat detector. In this case the most effective criterion for automatic fire detection is the flame. According to the fire regulation of korea, the compulsory standard provided that a flame detector shall be installed in a place that the attachment height of detector is higher than 20 m, chemical plants, hangar, refinery, etc.. The results of the research and development are discriminated between a flame and other radiant emitters, developed a UV detector tube contains an inert gas which absorbs UV radiation, developed PZT pyroelectric element is based on the use of photovoltanic cell, developed IR band-pass filter that only allow a 4.3 $\mu\textrm{m}$ radiation wavelength to reach the sensors and developed UV-IR combination flame detector combined into a single detection device.

  • PDF

삼파장 4채널 적외선식 불꽃감지기의 자가진단 성능 개선 (An Improvement on the Self Diagnostic Characteristics of the Triple Quard Channel Infrared Flame Detector)

  • 송현선
    • 조명전기설비학회논문지
    • /
    • 제30권1호
    • /
    • pp.49-54
    • /
    • 2016
  • There is needed the quard channel triple wave lengths pyroelectric infrared flame detector to recognize the unique characteristics of fire sources in various type. This system detects the triple wave lengths of infrared flame emitting maximum radient energy and scattering frequency of flame. The quard channel infrared flame detector detects the duplicate wave lengths of maximum radient energy to enhance the accuracy of detecting fire. Especially this paper focuss on development of the self diagnosis function system including contamination, temperature and input voltage. Therefore, the prevention and early suppression of fire is available.

THE DEVELOPMENT OF A UV FLAME DETECTOR FOR THE AUTOMATIC FIRE SUPPRESSION SYSTEM FOR ENGINE COMPARTMENT FIRES

  • Lim, Sung-Mook;Jung, Ki-Chang;Kim, Eung-Sik;Kim, Hong
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 1997년도 International Symposium on Fire Science and Technology
    • /
    • pp.590-597
    • /
    • 1997
  • In this work, a new type of UV flame detection system was developed. In order to measure the performance of UV flame detector, various kinds of experiments was performed. The results show that the maximum response time of the UV flame detector is 0.2 seconds when the detection distance is one meter The advantages of this system include wide area, high speed response and high sensitivity. After testing the W flame detector in engine compartment it detected fire within 0.09 seconds and extinguished within 5 seconds. Hence, the UV flame detector can be applied in automatic fire suppression system for automobiles.

  • PDF

마이크로프로세서를 사용한 UV/IR 불곶 감지기 (UV/IR flame detector using Microprocessor)

  • 박성진;임병현;임종연;김명원;윤길호
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 하계학술대회 논문집
    • /
    • pp.215-218
    • /
    • 2001
  • A flame detector responds either to radiant energy visible to the human eye or outside the range of human vision. Such a detector is sensitive to glowing embers, coals, or flames which radiate energy of sufficient intensity and spectral quality to actuate the alarm. An infra-red detectors can respond to the total IR component of the flame alone or in combination with flame flicker in the frequency range of 5 to 30 Hz. A major problem in the use of infrared detectors receiving total IR radiation is the possible interference of solar radiation in the infrared region. When detectors are located in places shielded from the sun, such as vaults. filtering or shielding the unit from the sun's rays is unnecessary. In this study, we proposed method for redue a false alarm with using filtering & sensor technology for distinguish of causes of raise a false alarm and pure flame.

  • PDF

자외선 센서를 이용한 화재감지기 응용 회로 설계 (Circuit Design of Ultraviolet Flame-Sensor for Fire-Fighting Appliances)

  • 김영민;김종만
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2008년도 춘계학술대회 논문집 센서 박막재료연구회 및 광주 전남지부
    • /
    • pp.1-5
    • /
    • 2008
  • In this paper, we proposed that when combustible burn with ultraviolet radiation, introduce fire detector with sensor of private-use detectable light energy as ultraviolet in energy of electromagnetic-wave type radiate from flame. This research using ultraviolet flame sensor is pyro-electric ultraviolet sensor based black body radiation theory. To have high sensibility and to gain proper output voltage, it has high responsive performance. This research introduced UV flame detector and proposed method of false alarm reduced to resemble fire. the result proposed the prevention and extinction of fire technique degree, certificated operation of detector.

  • PDF

FLAME DETECTOR의 응답특성연구

  • 이복영
    • 방재기술
    • /
    • 통권18호
    • /
    • pp.5-16
    • /
    • 1995
  • The capacity commonly required sensors includes capability of quickly and properly catching the conditions of a fire and discriminating other factors such as noise, interference, etc. IR flame detector which react to the infra-red rays emitted from the flame. This study is aimed to know the characteristic repond to the specified fire plate. Experiment is acted by manufacture's technical data that is explained relation of detective range and sensitivity.

  • PDF

초전형 삼파장 적외선식 불꽃감지기 신호회로 개발 (A Study on Signal Circuit of the Triple Pyroelectric Infrared Flame Detector)

  • 송현선;이의용
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.201-207
    • /
    • 2010
  • This thesis studies development of a triple pyroelectric Infrared flame detector to have appropriate reaction characteristics with proper operational features in various and radiant energy characteristics of fire sources, and to contribute to minimize the losses of human lives and properties by detecting fire in very early stage to restrict the spread of fire.

Determination of barbiturates in plasma by gas chromatography-fralme photometric detector after N, N'-flame photometric detector after N, N'-dimethylthiomethyl derivatization

  • Hyung, Yung;Park, Man-Ki
    • Archives of Pharmacal Research
    • /
    • 제9권3호
    • /
    • pp.131-138
    • /
    • 1986
  • A specific and sensitive gas chromatographic (GC) procedure with the flame photometric detector (FPD) was developed for determination of barbiturates such as barbital, allobarbital, secobarbital, phenobarbital and thiopental in plasma. In order to evaluate the performance of the FPD, the results were campared with those of the flame ionization detector (FID). After extraction of barbiturates from plasma, the barbiturates were quantitatively N, N-dimethylthiometyl (MTM)-derivatized with methylthiomethyl chloride in 1, 8-diazabicyclo [5, 4, 0] undec-7-ene catalyst. The data indicate that the FPD is about 4 times more sensitive than the FID for barbiturates, although it is less reproducible. The FPD also produced chromatogram with less back ground for extracted plasma sample. The FPD also produced chromatogram with less background for extracted plasma sample. The minimum detectable amount of MTM-thiopental on 3% OV-225 column was 4, 4fmol and that of other MTM-barbiturate was about 10.0fmol.

  • PDF

삼파장 적외선식 불꽃감지기의 자가진단 회로 개발 (A Study on Signal Circuit of the Self Diagnosis Type Triple Infrared Flame Detector)

  • 송현선;이의용
    • 조명전기설비학회논문지
    • /
    • 제27권10호
    • /
    • pp.69-74
    • /
    • 2013
  • There is needed the triple pyroelectric Infrared flame detector to really recognize problem, for the prevention and early suppression of fire. This system recognizes the characteristics of fire sources in various type and is communicated the message to the operators. Therefore, the prevention and early suppression of fire is available. Especially this paper focuss on development of the self diagnosis type flame detector for preventing malfunction comparing of basic and detected values.