• Title/Summary/Keyword: Flame Control

Search Result 300, Processing Time 0.027 seconds

A study on the flame recognition technique of an oxygen blown converter (전로 화염 인식에 관한 연구)

  • 류창우;채홍국;은종호
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1473-1475
    • /
    • 1996
  • In this paper, we propose the method to find the active region of flame which is produced within the gap between an oxygen blown converter and a skirt. For real-time image processing, basic region segmentation algorithms such as thresholding and XORing are used to segment the active region of flame. The result of this processing may be useful to clear the relationship between hood pressure and flame.

  • PDF

An Experimental Study on the Lift-off Characteristics of the Triple Flame within a Diverging Duct (단면 확대 덕트 내에 형성된 삼지화염의 부상특성에 관한 실험적 연구)

  • Seo, Jeong-Il;Kim, Nam-Il;Oh, Kwang-Chul;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2003.05a
    • /
    • pp.85-91
    • /
    • 2003
  • The lift-off characteristics of the triple flame within a diverging duct have been studied experimentally using a multi-slot burner, which can control the concentration gradient and the mean velocity independently. In this experiment the triple flame was stabilized successfully in lift-off condition and flame stabilization with a duct or without a duct, lift-off heights, and some other characteristics were examined for propane flame. It was examined that the effects with various concentration gradient and mean velocity on the triple flame. It was found that minimum value of the lift-off heights exist at a certain concentration gradient for constant mean velocity and flame with a duct is more stable than that without. Moreover the propagation velocity of the flame becomes maximum at a certain concentration gradient regardless of mean velocity.

  • PDF

An Experimental Study on the Lift-off Characteristics of the Triple Flame with Concentration Gradient (농도구배가 삼지화염의 부상특성에 미치는 영향에 관한 실험적 연구)

  • Seo, Jeong-Il;Kim, Nam-Il;Oh, Kwang-Chul;Shin, Hyun-Dong
    • 한국연소학회:학술대회논문집
    • /
    • 2004.06a
    • /
    • pp.7-14
    • /
    • 2004
  • The lift-off characteristics of the triple flame have been studied experimentally with various mean velocities and concentration gradients using a multi-slot burner, which can control the concentration gradient and the mean velocity independently, Lift-off height, axial maximum velocity, flame temperature, and some other characteristics were examined for methane and propane flame, It was found that minimum values of the lift-off heights exist at a certain concentration gradient for constant mean velocity, and this result implies that the propagation velocity has a maximum value at this condition, OH radical distribution was measured with LIF method and velocity variation along streamline was measured with PlV system. In addition maximum temperature along streamline was measured with CARS system. The intensity of the diffusion flame affects on the propagation velocity of triple flame in the region of very weak concentration gradient.

  • PDF

The Influence of Combustor Atmospheric Pressure on Flame Characteristics (연소실 분위기 압력이 화염형상에 미치는 영향)

  • Kim, J.R.;Choi, G.M.;Kim, D.J.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.1134-1139
    • /
    • 2004
  • Recently, development of flame control scheme has been hot issues in the combustion engineering. It has been held that flame shape can be controllable by pressure inside combustor. The influence of combustor atmospheric pressure on flame shape was investigated in the present study. The flame shape, flammable limit, flame temperature and nitric oxide emission were measured as functions of combustor atmospheric pressure and equivalence ratio. The reaction region became longer and wider with decreasing combustor atmospheric pressure by direct photography, hence reduction of blow off limit. This tendency was also observed in the mean flame temperature distribution. Nitric oxide emission decreased with decreasing combustor atmospheric pressure. Low NOx combustion is ascribed to wide-spread reaction region in the low atmospheric pressure condition. These results demonstrate that flame shape and nitric oxide emission can be controllable with combustor atmospheric pressure.

  • PDF

Development of PET Flame Retardant Sheets for Industrial Materials by Control of Manufacturing Process (제조공정제어에 의한 친환경 고성능 산업용 PET 난연시트 제조기술의 개발)

  • Kim, Hea-In;Hong, Yo-Han;Park, Soo-Min
    • Textile Coloration and Finishing
    • /
    • v.21 no.4
    • /
    • pp.46-56
    • /
    • 2009
  • In order to establish the standard manufacturing condition of PET flame retardant sheets, physicochetnical properties of the samples made by the conventional flame-retardant finishing were systematically investigated, including compatibility among flame retardant agent and finishing auxiliaries, surface property, and wicking property. From this results, the addition of washing and renapping process after the shearing process was required for the more effective in producing PET flame-retardant sheet by the standard finishing. The effect of the modification of the regular flame retardant finishing process was studied by FTIR, TGA, and flame retardancy test.

An Experimental Studies on Flame and NOx Emission Characteristics of Rapid Mix Combustor (초 저 NOx 선단 예혼합 연소기의 화염 및 NOx 배출 특성 연구)

  • Mun, Min-Uk;Kim, Se-Won;Shin, Myung-Chul;Kim, Yong-Mo
    • 한국연소학회:학술대회논문집
    • /
    • 2006.10a
    • /
    • pp.122-127
    • /
    • 2006
  • The objective of this research is to determine generally applicable design principles for the development of Rapid mix burner. Details operating RMB(Rapid mix burner) is designed that thermal NOx and prompt NOx formation be reduced through control of low peak flame temperature, and nearly uniform flame temperature by rapid mixing at the ignition point. Results from RMB(Rapid mix burner) achieving lower than 43 ppm NOx emissions and nearly flame temperature uniform

  • PDF

Combustion Radicals and NOx Emissions Characteristics by Control of Partially Premixed Flames (부분적 예혼합화염제어에 의한 연소 라디칼 및 NOx 배출물 특성)

  • Kim, Tae-Gwon;Jang, Jun-Yeong
    • Transactions of the Korean Society of Mechanical Engineers B
    • /
    • v.26 no.4
    • /
    • pp.561-569
    • /
    • 2002
  • This paper presents an investigation on $C_2$, CH, OH radicals and NOx emissions in partially premixed flames with acoustic excitation. The radicals are visualized by the digital image technique with optical filters and ICCD camera while NOx emissions are determined by a chemiluminescent detection(NOx analyser). The measurements are made in flames with an overall equivalence ratio (${\phi}_o$) 0.5 and a center tube equivalence ratio(${\phi}_c$) varing from 1.1 to 5.0 for a constant fuel flow rate. In the case of excitation, the visual shape of the flame is changed from laminar to turbulent-like flames. Images of $C_2$, CH, and OH radicals resemble those of the flame appearances as the excitation phase is varied, and the radicals generated at the upstream are convected toward the downstream. It is inferred that the flame characteristics is affected by the flow characteristics of air-fuel mixture. In the case of acoustic excitation, OH radicals are much increased relative to unexcitation. From the radicals and flame visualization under acoustic excitation, the reduction of flame length affects the shorter residence time of center tube mixture, and significantly influences the NOx reduction.

Pulverized Coal Injection System Development to Raise Combustion Efficiency of a Blast Furnace (고로미분탄 취입랜스의 연소효율 향상을 위한 노즐 제어의 최적화)

  • Choi, Seung-Hyun;Kwak, Na-Soo;Kim, Jae-Yeol
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.18 no.6
    • /
    • pp.690-696
    • /
    • 2009
  • This paper introduces the automatic fine Bituminous Coal injection lance position control method using flame image process. The fine Coal injection lance is used to supply additional heat into the furnace in Mill plant. It injects fine coal into high pressured air flow and produces very heated and high pressured flame. For the such high temperature and pressure, the fine coal injection lance effects not only efficiency of burner but also furnace abrasion. To keep efficient combustion status and to avoid the abrasion, in this paper, the flame is monitored by computer image process. This paper proposes the flame image process method and lance position control according to calculated result for flame image process.

  • PDF

Flame Image Processing System for Combustion Condition Monitoring of Pulverized Coal Firing Boilers in Thermal Power Plant (발전용 미분탄 보일러의 연소 상태 감시를 위한 화염 영상 처리 시스템)

  • Baek, Woon-Bo;Shin, Jin-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.12 no.11
    • /
    • pp.1119-1123
    • /
    • 2006
  • The flame image processing and analysis system has been investigated for the optimal pulverized coal firing of thermal power plant, especially for lower nitrogen oxide generation and more safe operation. We aimed at gaining the relationship between burner flame image information and emissions of nitrogen oxide and unburned carbon in furnace utilizing the flame image processing methods, by which we quantitatively determine the condition of combustion on the individual humors. Its feasibility test was undertaken with a pilot furnace for coal firing, through which the system was observed to be effective for the monitoring of the combustion condition of pulverized coal firing boilers.

An Experimental study on characteristics of flame chemiluminescence using multi channel photo diode (다채널 포토다이오드를 이용한 화염 자발광 특성에 대한 실험적 연구)

  • Jang, Byunghwa;Kwon, Minjun;Kim, Daehae;Lee, Changyeop;Kim, Sewon
    • 한국연소학회:학술대회논문집
    • /
    • 2015.12a
    • /
    • pp.319-320
    • /
    • 2015
  • This study is aiming to establish the relationship between the optical signal of flame through an optical fiber and the equivalent ratio of flame. In this experiment, flame optical signal in a furnace is measured using photodiode. The combustion system is composed of 15W turbulent burner and industrial boiler, and flame chemiluminescence is measured at various experimental conditions. In this study, the flame chemiluminescence of turbulent premixed flame is measured using commercially available photodiode. It is experimentally investigated the relationship between equivalent ratio and photodiode signal.

  • PDF