• 제목/요약/키워드: Fixture unit

검색결과 45건 처리시간 0.025초

하악 구치부에서 임플랜트 배열방식에 따른 임플랜트지지 고정성 국소의치의 광탄성 응력 분석 (PHOTOELASTIC STRESS ANALYSIS OF IMPLANT SUPPORTED FIXED PROSTHESES WITH DIFFERENT PLACEMENT CONFIGURATIONS IN MANDIBULAR POSTERIOR REGION)

  • 조혜원;김난영;김유리
    • 대한치과보철학회지
    • /
    • 제43권1호
    • /
    • pp.120-131
    • /
    • 2005
  • Statement of problem. More than 70% of patients who need the implant supported restoration are parially edentulous. The principles of design for implant supported fixed partial denture in mandibular posterior region are many and varied. Jurisdiction for their use is usually based on clinical evaluation. There are several areas or interest regarding the design of implant supported fixed partial denture in mandibular posterior region. 1) Straight and tripod configuration in implant placement, 2) Two restoration types such as individualized and splinted restorations. Purpose. The purpose of this study was to compare the amount and distribution of stress around the implant fixtures placed in the mandibular posterior region with two different arrangements and to evaluate the effects of splinting using the photoelastic stress analysis. Material & methods. 1) Production of study model: Mandibular partially edentulous model was waxed-up and duplicated with silicone and two models were poured in stone. 2) Fixture installation and photoelastic model construction: Using surveyor(Ney, USh), 3 fixtures(two 4.0 $\times$13 mm, one 5.0$\times$10 mm, Lifecore, USA) were insta)led in straight & tripod configurations. Silicone molds were made and poured in photoelastic resin (PL-2. Measurements group, USA). 3) Prostheses construction: Four 3-unit bridges (Type III gold alloy, Dongmyung co., Korea) were produced with nonhexed and hexed UCLA abutments and fitted with conventional methods. The abutments were tightened with 30 Ncm torque and the static loads were applied at 12 points of the occlusal surface. 4) Photoelastic stress analysis : The polarizer analyzer system with digital camera(S-2 Pro, Fujifilm, Japan) was used to take the photoelastic fringes and analysed using computer analysis program. Results. Solitary hexed UCLA restoration developed different stress patterns between two implant arrangement configurations, but there were no stress transfer to adjacent implants from the loaded implant in both configurations. However splinted restorations showed lesser amount of stresses in the loaded implants and showed stress transfer to adjacent implants in both configurations. Solitary hexed UCLA restoration with tripod configuration developed higher stresses in anterior and middle implants under loading than implants with straight configurations. Splintied 3 unit fixed partial dentures with tripod configuration showed higher stress development in posterior implant under loading but there were no obvious differences between two configurations. Conclusions. The tripod configuration of implant arrangement didn't show any advantages over the straight configuration. Splinting of 3 unit bridges with nonhexed UCLA abutments showed less stress development around the fixtures. Solitary hexed UCLA restoration developed tilting of implant fixture under offset loads.

Measurement of the Volumetric Thermal Errors for CNC Machining Center Using the Star-type-styluses Tough Probe

  • Lee, Jae-Jong;Yang, Min-Yang
    • International Journal of Precision Engineering and Manufacturing
    • /
    • 제1권1호
    • /
    • pp.111-117
    • /
    • 2000
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric errors, thermally-induced errors, and the deterioration of the machine tools. Geometric and thermal errors of machine tools should be measured and compensated to manufacture high quality products. In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models the thermal errors for error analysis and develops an on-the-machine measurement system by which the volumetric errors are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses and a designed spherical ball artifact (SBA). Experiments show that the developed system provides a high measuring accuracy, with repeatability of $\pm$2$\mu\textrm{m}$ in X, Y and Z directions. It is believed that the developed measurement system can be also applied to the machine tools with CNC controller. In addition, machining accuracy and product quality can be also improved by using the developed measurement system when the spherical ball artifact is mounted on a modular fixture.

  • PDF

기상계측 시스템을 이용한 머시닝센터의 열변형 오차 모델링 및 오차측정 (Modeling and Measurement of Thermal Errors for Machining Center using On-Machine Measurement System)

  • 이재종;양민양
    • 한국정밀공학회지
    • /
    • 제17권1호
    • /
    • pp.120-128
    • /
    • 2000
  • One of the major limitations of productivity and quality in metal cutting is the machining accuracy of machine tools. The machining accuracy is affected by geometric errors, thermally-induced errors, and the deterioration of the machine tools. Geometric and thermal errors of machine tools should be measured and compensated to manufacture high quality products. In metal cutting, the machining accuracy is more affected by thermal errors than by geometric errors. This paper models of the thermal errors for error analysis and develops on-the-machine measurement system by which the volumetric error are measured and compensated. The thermal error is modeled by means of angularity errors of a column and thermal drift error of the spindle unit which are measured by the touch probe unit with a star type styluses and a designed spherical ball artifact (SBA). Experiments, performed with the developed measurement system, show that the system provides a high measuring accuracy, with repeatability of $\pm$2${\mu}{\textrm}{m}$ in X, Y and Z directions. It is believed that the developed measurement system can be also applied to the machine tools with CNC controller. In addition, machining accuracy and product quality can be improved by using the developed measurement system when the spherical ball artifact is mounted on the modular fixture.

  • PDF

구치부 단일 임플란트의 생존율에 대한 후향적 연구 (A Retrospective Clinical Study of Survival Rate for a Single Implant in Posterior Teeth)

  • 한성일;이재훈
    • Maxillofacial Plastic and Reconstructive Surgery
    • /
    • 제34권3호
    • /
    • pp.186-199
    • /
    • 2012
  • Purpose: Single implants, of which screw loosening has been observed frequently, presents problems such as fixtures fractures, marginal bone loss, and inflammation of the soft tissue around the implant. However, the single implant is more conservative, cost effective, and predictable compared to the 3 unit bridge with respect to the long-term outcome. This study evaluated the survival rate as well as future methods aimed at increasing the survival rate in single implants in posterior teeth. Methods: Among the implants placed in the Dankook University Dental Hospital department of Oral & Maxillofacial surgery from January 2001 to June 2008, 599 implants placed in the maxillar and mandibular posterior were evaluated retrospectively. Survival rates were investigated according to implant location, cause of tooth loss, gender, age, general disease, fixture diameter and length, surface texture, implant type and shape, presence of bone graft, surgery stage, surgeons, bone quality and opposite teeth. Results: Out of 599 single implants in posterior teeth, 580 implants survived and the survival rate was 96.8%. The difference in survival rate was statistically significant according to the implant location. The survival rate was low (84.2%) in implants exhibiting a wide diameter (${\geq}5.1mm$) and the surface treated by the acid etching group demonstrated a significantly lower survival rate (91.1%). One stage surgical procedure, which implemented a relatively better bone quality survival rate (100%), was higher than the two stage surgical procedure (96.1%). The survival rate of type IV bone quality (75%) was significantly lower than the other bone quality. Conclusion: Single posterior teeth implant treatments should use an improved surface finishing fixture as well as careful and safe procedures when performing implant surgery in the maxilla premolar and molar regions since bone quality is poor.

임플랜트 고정체의 형태에 따른 광탄성 응력분석 (PHOTOELASTIC STRESS ANALYSIS OF IMPLANTS ACCORDING TO FIXTURE DESIGN)

  • 문소희;김난영;김유리;조혜원
    • 대한치과보철학회지
    • /
    • 제44권1호
    • /
    • pp.51-62
    • /
    • 2006
  • Purpose: The purpose of this study was to evaluate the pattern and the magnitude of stress distribution in the supporting tissues surrounding three different types of implants(ITI, 3i. and Bicon implant system) Material and method: Photoelastic models were made with PL-2 resin(Measurements Group, Raleigh, USA) and three implants of each kind were placed in the mandibular posterior edentulous area distal to the canine. For non-splinted restorations, individual crowns were fabricated on three titanium abutments. For splinted restorations, 3-unit axed partial dentures were fabricated. Photoelastic stress analyses were carried out to measure the fringe order around the implant supporting structure under simulated loaded conditions(15 lb. 30 lb). Conclusion: The results were as follows; 1 Regardless of the implant design, stresses were increased in the apex region of loaded implant when non-splinted restorations were loaded. While relatively even stress distribution occurred with splinted restorations. Splinting was effective in the second implant. 2. Strain around Bicon implant were lower than those of other implants, which confirmed the splinting effect. The higher the load, the more the stress occurred in supporting tissue, which was most obvious in the Bicon system. 3. Stress distribution in the supporting tissue was favorable in the ITI system. while the other side of 3i system tended to concentrate the stress in some parts.

모듈러 지그와 픽스쳐의 설계 시스템 개발 (Design System Development of the Modular Jig & Fixture)

  • 정효상;이위로;박정민
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2005년도 춘계학술대회 논문집
    • /
    • pp.714-717
    • /
    • 2005
  • The concept of jigs and fixtures makes it possible to build fixtures that can be dismantled at project completion. Since this concept is modular, it is not limited to any particular unit shapes or sizes. Various standards assure that each component assemble rapidly, to get precision and accuracy. Best suited for prototype and low volume production, as well as, start-up or zero-runs, it can also substitute for damaged dedicated fixtures to minimize down-time. It need to do DB for each part by Pro/Engineer and to assemble before manufacturing. In the future will assemble each of clamping and position parts by automation.

  • PDF

임플란트-지대주-나사의 적합에 관한 연구 (A STUDY ON THE FIT OF THE IMPLANT-ABUTMENT-SCREW INTERFACE)

  • 김낙형;정재헌;손미경;백대화
    • 대한치과보철학회지
    • /
    • 제41권4호
    • /
    • pp.503-518
    • /
    • 2003
  • Statement of problem : There have been previous studies about considerable variations in machining accuracy and consistency in the implant-abutment-screw interfaces. Purpose : The purpose of this study was to evaluate the machining accuracy and consistency of implant/abutment/screw combinations on two randomly selected implants from each of four manufactures. Material and methods : In this study, screws were respectively used to secure a cemented abutment, to a hexlock implant fixture ; teflon coated titanium alloy screw(Torq-Tite) and titanium alloy screw in Steri--Oss system, gold-plated gold-palladium alloy screw(Gold-Tite) and titanium alloy screw in 3i system gild screw ana titanium screw in AVANA Dental Implant system, and titanium screws in Paragon System. The implants were perpendicularly mounted in polymethyl methacrylate autopolymerizing acrylic resin block(Orthodontic resin, Densply International Inc. USA) by use of dental surveyer. Each abutment screw was secured to the implant with recommended torque value using a digital torque controller. Each screw was again tightened after 10 minutes. All samples were cross sectioned with grinder-polisher unit(Omnilap 2000 SBT Inc) after embeded in liquid unsaturated polyester (Epovia, Cray Valley Inc) Results : There were the largest gaps in the neck areas of screws in hexagonal extension implants which were examined in this study. The leading edge of the abutment screw thread (superior surface) was in contact with the implant body thread, and the majority of the contacting surfaces were localized to the middle portion of the mating threads. Considerable variation in the contacting surfaces was noted in the samples evaluated. Amounts of contact in the abutment screw thread were larger for assemblies with Gold-Tite screw, gold alloy screw. Torq-Tite screw than those with titanium screws. The findings of intimate contact between the screw and screw seat were seen in all samples, regardless of manufacturers. However, microgap between the head and lateral neck surface of the screw and the abutment could be dectected in all samples. The findings of intimate contact between the platform of the implant and the bottom of the abutment were consistent in all samples, regardless of manufacturers. However, microgaps between the lateral surface of external hex of the fixture and the abutment could be dectected in all samples. Conclusion : Considerable variations in machining accuracy and consistency were noted in the samples and the implant-abutment-screw interfaces were incomplete. From the results of this study, further development of the system will be required, including improvements in pattern design.

아파트 리모델링의 실내환경 계획지침 개발 (Development of Guidelines for Indoor Environment in Apartment Remodeling Projects)

  • 최윤정
    • 한국주거학회논문집
    • /
    • 제20권3호
    • /
    • pp.1-10
    • /
    • 2009
  • The final aim of this study was to propose guidelines for the indoor environment of apartment remodeling projects. The first task of this study was to understand the major elements and the actual condition of the remodeling for apartment unit by carrying out in-depth interviews on residents and specialists. The open-access interviews were conducted with interior designers who have a wide experience of apartment remodeling and residents who live in recently remodeled apartment units. The second task was to evaluate the actual condition of the indoor environment and to analyze the main factors that affect the indoor environment in remodeled apartment units. Field measurements were carried out in twenty apartment units occupied after remodeling, recording indoor environment elements (indoor temperature, globe temperature, relative humidity, $CO_2$, CO, PM10, TVOC, HCHO, illumination, and equivalent noise level). Moreover, resident interviews and researcher observations were carried out to determine the contents of the remodeled unit and to investigate the architectural and living factors(like ventilation characteristics, etc.) related to the indoor environment. The results are as follows. The remodeling elements generally included the changing of lighting fixtures and finishing materials in all the spaces, the integration of the balcony into the children's room, the installation of furniture in the kitchen and the entrance, the changing storage furnitures and equipments in the bathroom. The average levels of each unit of relative humidity, $CO_2$, TVOC, HCHO, equivalent noise level, and illumination were proved to be on the whole in inadequate condition. The factors that affect these indoor elements were classified as remodeling factors (remodeling amounts, extent balcony integration, and lighting fixture exchange), ventilation characteristics, and living factors. According to these results, this research proposed the guidelines for the indoor environment in apartment remodeling projects.

LED 백라이트유닛 도광판의 연구동향 (Research Trends in Light Guide Plates for LED Backlight Units)

  • 박소희;최은서;안선영;신용진
    • 한국광학회지
    • /
    • 제28권6호
    • /
    • pp.314-326
    • /
    • 2017
  • 현대생활에 매우 밀접하게 연관되어 있는 디스플레이는 IT산업이 발전함에 따라 단순한 표시장치에서 개인과 기기, 더 나아가 또 다른 개인을 연결해주는 네트워크의 창으로서 발전하고 있다. 이와 같은 디스플레이의 가장 중요한 구성요소인 백라이트유닛이 보다 얇고 더 밝으며 전기 소모량도 적게 구현하기 위해서 LED 광원을 적용하였으며, 휘도와 휘도 균일도 및 시야각을 향상 시키기 위한 복합 도광판에 대한 연구가 시작되었다. 본 논문에서는 최근 10여 년간 LED 백라이트 유닛의 괄목할만한 성장을 가능하게 한, 도광판의 산란패턴 형성에 관한 연구와 광원의 배치 및 구성 기술에 관하여 정리하고, 더 나아가 이러한 도광판 기술을 최근 주목을 받고 있는 LED 조명기구 설계에 적용시킨 대면적 flat-type 조명시스템에 대해 개괄적으로 기술한다. 최종적으로 현 기술을 보다 발전적으로 향상시킬 수 있는 방안 및 적용 방법에 관하여 논의한다.

Experimental investigation of interlaminar mechanical properties on carbon fiber stitched CFRP laminates

  • Iwahori, Yutaka;Ishikawa, Takashi;Watanabe, Naoyuki;Ito, Akira;Hayashi, Yoichi;Sugimoto, Sunao
    • Advanced Composite Materials
    • /
    • 제16권2호
    • /
    • pp.95-113
    • /
    • 2007
  • Experimental investigations of interlaminar mechanical properties for carbon fiber reinforced plastic (CFRP) laminates were carried out using aramid fiber ($Kevlar^{(R)}$-29 1000d) and carbon fiber (TR40-1K 612d, Mitsubishi Rayon) stitching. Various carbon fiber (CF) stitch densities were used to prepare a number of CF stitched CFRP laminates for double cantilever beam (DCB) tests. An insert tongue-type loading fixture, developed by the Japan Aerospace Exploration Agency (formerly the National Aerospace Laboratory of Japan), was also employed in the DCB test. Interlaminar tension tests were carried out under an out-of-plane directional loading using a single CF stitch thread in the CFRP laminates. The DCB test results clarified that the relationship between the volume fractions of the CF stitch thread ($V_{ft}$) and mode I critical energy release rate ($G_{Ic}$) showed a mostly linear function with a higher gradient than that of the $Kevlar^{(R)}$ stitched CFRP laminates. The CF stitched CFRP tension test results indicated that the consumption energy per unit area ($E_i$) was larger than that of $Kevlar^{(R)}$ stitched CFRP laminates.