• 제목/요약/키워드: Fixture

검색결과 725건 처리시간 0.03초

가속도계 고정기구의 동특성에 대한 연구 (Study for Dynamic Characteristics of the Accelerometer Mounting Fixtures)

  • 이종규;김성부;이두희;배동명;신창혁;조승일
    • 한국소음진동공학회논문집
    • /
    • 제17권4호
    • /
    • pp.350-355
    • /
    • 2007
  • Accelerometer mounting fixtures were prepared with the different materials(Ti and SUS). The dynamic characteristics of the mounting fixture were analyzed by finite element method(FEM), and the mode shape of each order and the displacement response for modelling the mounting fixture were analyzed by ANSYS, then resonant frequencies of the mounting fixtures with Ti and SUS were 22.700 and 23.390 kHz, respectively. The dynamic characteristics of the mounting fixture with the different positions were obtained by using laser interferometer. The response of the accelerometer was nearly a constant from 40 Hz to 500 Hz, but the change of the acceleration was increased with an increase of the frequency above 500 Hz.

Development of Drilling Jig by Practical and Adaptive Tooling System(Part 1) - System Analysis of Part Drawing and Jig Design

  • Sim, Sung-bo;Lee, Sung-Taeg
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2000년도 춘계학술대회 논문집
    • /
    • pp.104-108
    • /
    • 2000
  • Drilling Jig is the device according to industrial demand for multi manufacturing products on the growing at alarming rate. In the field of design and making for machine tool working, welding, assembling with jig and fixture for mass production is a specific division. In order to prevent the production defects the optimum design of product, fig and fixture putting in the field is very significant manufacturing method. They require analysis of many kinds of important factors, theory and practice of machine tool operating process and its phenomena, jig & fixture structure, machining condition for tool making tool materials, heat treatment of jig & fixture components, know-how and so on. In this study we designed and constructed a drilling jig of mass production and performed tryout under the Auto CAD, database, and window environment. Especially Part1 of this study is reveals with the analysis of part drawing, jig planning, jig design etc.

  • PDF

치구계획의 자동화시스템 구성 및 데이텀 체계의 결정 (System Architecture and Datum Reference Frame for Computer Aided Fixture Planning System)

  • 조규갑;정영득
    • 산업공학
    • /
    • 제4권2호
    • /
    • pp.1-12
    • /
    • 1991
  • This paper deals with the development of a computer aided fixture planning system that automatically selects set-ups, set-up sequence and fixture design for prismatic parts. This study presents the hierarchical data structure for feature-based part model and the preprocessing procedure for the proposed system. The preprocessing procedure generates tools such as DDR(Degree of Dimensional Relationship), AMV(Admissible Misalignment Value) and the datum reference frame of each feature according to the proposed decision table. The proposed system is called AFIX(Automated FIXture planning system) which is implemented by using C language on the workstation. A case study for a cavity plate is presented to show the performance of the AFM.

  • PDF

서보라이트 픽스쳐의 진동 특성 개선 방법 (Methodology on Improving Vibration Characteristics of Servo Write Fixture)

  • 윤태용;로저 쿠;앤드루 핸런;찰스 테일러
    • 정보저장시스템학회논문집
    • /
    • 제7권2호
    • /
    • pp.47-52
    • /
    • 2011
  • This paper presents a method to improve vibration characteristics of servo track write (STW) fixture. STW fixtures supported by flexible mounts are subject to various vibration sources. Using Finite element analysis (FEA) vibration modes of the fixture are identified. The FEA results suggest certain vibration modes be reduced through design change of flexible mounts to improve vibration responses of the fixture. Based on layered flexible mounts theory a parametric study on shear and bending stiffness is performed to obtain a suitable flexible mount design leading to increased resistance to rocking motion. Experiments confirm improvement of vibration characteristics and drive performance through new mounts design.

EFFICIENT DESIGN OF CAPACITOR DISCHARGE IMPULSE MAGNETIZER SYSTEM FOR 8-POLE MAGNET

  • Kim, Pill-Soo;Kim, Yong;Baek, Soo-Hyun
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.828-832
    • /
    • 1995
  • This paper describes the efficient design, analysis method and experimental verification of capacitor discharge impulse magnetizer system. A capacitor discharge magnetizer system is used to produce a high current impulse of short duration in this magnetizing fixture. The parasitic resistance and parasitic inductance of the capacitor discharge impulse magnetizer system have been estimated using known air-core test coil. Finite element analysis (using MAXWELL 2-D field simulator) and magnetizing circuit analysis (using SPICE) are also used as part of the design and analysis process of the capacitor discharge impulse magnetizer system. Application study for a magnetizing fixture design is shown. 8-pole magnetizing fixture has been designed and analyzed using finite element analysis. The fixture design for 8-pole magnet are presented along with the experimental results. The experimental results have been achieved using a high-voltage, high-energy capacitor discharge impulse magnetizer and 8-pole iron core fixtures (charging voltage : 2000[V], capacitor bank : 4000[$\mu\textrm{F}$]).

  • PDF

2-D FIELD ANALYSIS OF MAGNETIZING FIXTURE FOR STATOR MAGNET OF AIR-CLEANER DC MOTOR

  • Kim, Pill-Soo;Kim, Yong;Baek, Soo-Hyun
    • 한국자기학회지
    • /
    • 제5권5호
    • /
    • pp.833-836
    • /
    • 1995
  • A capacitor discharge impulse magnetizer is used to produce a high current pulse of short duration in a magnetizing fixture for magnets of the various shapes. The problem of designing custom fixtures for magnetization has often been considered more of conventional experience than a scientific theory. Therefore, the design of magnetizingfixture has until recently been a "cut and try" process. It was common to literally blow up one or more fixtures beforeachieving the desired results. Finite element CAD package allow the design of such a fixture. Since magnetizing fixtures come in a variety of sizes and shapes, there is usually no simple analysis method that can be used to estimate the field characteristics of the fixtures. Instead, one typically uses finite element analysis. FEA program MAXWELL is the primary tool used here. The purpose of this study was a examine both theoretically and experimentally the field characteristics inside the fixture. Independent of sizes and shapes of magnetizing fixtures, the desired magnetic field can be obtained with resonable predictability. The experimental results have been achieved using a 1000[V], 22.4[KJ] capacitor discharge magnetizer and iron-core fixtures.

  • PDF

재구성형 모듈러셀의 팔레트-치구 할당: 통합적 접근 (Pallet-fixture Allocation in Reconfigurable Manufacturing Cells: An Integrative Approach)

  • 한수민;서진우;박진우;이종국;강경철;이상호;문점생
    • 한국정밀공학회지
    • /
    • 제29권4호
    • /
    • pp.357-366
    • /
    • 2012
  • To schedule a Reconfigurable Manufacturing Cell (RMC), reconfiguration and setting decisions should be made first. Those decisions, together with characteristics of production orders, affect attainable performance of a system. So an integrative approach is required considering all decisions and characteristics rather than dealing with each of them separately. Pallet-fixture allocation, as a decision problem in setting, which determines the number of pallets to be equipped with each fixture type to produce different types of products, has rarely been investigated. In this study, several pallet-fixture allocation rules are proposed including both simple and novel ones. Then system performance is investigated through various combinations of setting and scheduling decisions (rules) for given system configurations and production orders, via simulation. The result shows that one of proposed pallet-fixture allocation rules which considers both configuration and order characteristic outperforms the others, justifying the necessity of an integrative approach in the RMC operation.

대형 열진공챔버용 내부 위성체 근접 치구 설계 (Design of Access Fixture for a Large Vacuum Chamber)

  • 이상훈;조혁진;서희준;문귀원
    • 항공우주산업기술동향
    • /
    • 제8권1호
    • /
    • pp.55-61
    • /
    • 2010
  • 우주환경은 고진공 환경과 태양 복사열에 의한 고온 환경 및 극저온이 반복되는 가혹한 환경으로, 위성체는 지상에서 발사되어 우주궤도에 진입한 순간부터 이러한 우주환경에 노출되어 위성체의 주요부품에 기능장애가 발생하고 결국 임무의 실패로 이어지기도 한다. 따라서 위성체는 지상에서 우주환경시험을 거쳐 기능 및 작동상태를 점검해야 한다. 한국항공우주연구원에서는 정지궤도 위성과 같은 대형 위성체의 시험을 위해 ${\phi}8m{\times}L10m $급의 대형열진공챔버를 국산화 제작하였다. 대형챔버 내부에서 우주환경시험을 수행하기 위해서는 각종 EGSE cable의 연결, MLI 도포 및 대형 챔버 내부에 대한 접근이 필요하다. 대형열진공챔버는 위성체의 크기에 비해 매우 큰 진공용기로 실제 작업시 위성체에의 접근이 용이하지 않다. 이에 대형열진공챔버 내부에서 위성체 및 챔버 내부 접근의 용이성을 제공하는 전용 치구의 필요성이 대두되어 이를 설계하고자 하며, 본 논문은 access fixture라 불리는 전용치구의 설계 과정에 대해 설명한다.

  • PDF

치주질환에 이환된 환자에서 구치 상실 치열 수복을 위한 임플란트 수복 (Implant-Supported Fixed Prostheses for the rehabilitation of distal free end in periodontally compromised dentitions Number of fixtures affecting bone tissue change)

  • 이승원;김영수
    • Journal of Periodontal and Implant Science
    • /
    • 제35권1호
    • /
    • pp.53-63
    • /
    • 2005
  • Number of fixtures supporting prosthesis for rehabilitation of partial edentulism in distal area is an important factor in distal area to the bone tissue response around dental implant. Optimal number and optimal positioning of dental implant has leaded to the stable condition of bone tissue and successful long-term treatment outcome. This clinical and radiographic study was performed to document and evaluate the short-term result of occlusal rehabilitation by means of implant-supported fixed prostheses (ISPs) especially for partial edentulism in distal area in patients treated for advanced periodontal disease and to verify the number of fixture affecting the bone tissue response. A total of 30 consecutive patients referred because of advanced periodontal disease were included. Before the implant therapy was initiated, periodontal treatment was performed and the outcome evaluated during at least a 6-month period. An individual maintenance care program was designed for each patient. All 75 implants were placed using a 2-stage surgical approach. The patients were divided into 2 groups, in one of which two fixtures were placed and in the other of which three fixtures were placed with tripodal geometry. Following installation of the ISPs, all patients underwent a baseline examination including evaluation of i) oral hygiene, and ii) periodontal/ peri-implant conditions, and iii) radiographs. These examinations were repeated annually during the 1 or 2-year observation period. The results were as follows: 1.No single implant was lost during the observation follow-up period. 1.The percentage of plaque harboring surfaces and bleeding units upon probing were found to be low (<10%), and no soft tissue complications were recorded. 1.Two-fixture group showed bone destruction ranged from 0.0mm to 1.5mm and the mean was 0.31mm. Three-fixture group showed more bone destruction of 0.51mm. There was no statistically difference between two groups. These results suggested that the factor for success is not the number of fixture but the strict maintenance of peri-implant tissue health and initial stability of fixture.

수종의 내측연결 임플랜트 시스템에서 고정체-지대주-나사계면의 적합에 관한 연구 (Fit of Fixture/Abutment/Screw Interface of Internal Connection Implant Systems)

  • 심덕보;김희중;오상호;정재헌
    • 구강회복응용과학지
    • /
    • 제24권3호
    • /
    • pp.283-298
    • /
    • 2008
  • 이 연구의 목적은 내측연결 임플랜트 시스템의 고정체-지대주-나사간의 계면 적합도를 알아보기 위한 것이다. 실험에 이용된 임플랜트 시스템은 Certain, Xive, Replace, Ankylos, SSII 이다. 이 시스템의 고정체와 지대주를 제조사의 권장 토크로 조인후 액상의 불포화 폴리에스터 용액에 고정한 후 절단하였다. 모든 표본은 절단, 연마후 주사전자 현미경으로 관찰하였다.내측연결 시스템의 적합도를 관찰한 결과, 각 제조사들 사이에 차이는 있으나 대부분의 내측연결 시스템의 경우엔 고정체와 지대주의 접촉은 긴밀히 접촉하는 경향을 가지고 있음을 알 수 있었다. 그러나 지대주와 나사, 고정체와 나사 간에는 다양한 형태의 틈이 존재하였다. 이러한 틈들이 나사의 불안정, 미생물의 군집, 악취 등에 어떠한 영향을 미칠지는 앞으로 계속적인 연구가 필요할 것으로 사료된다.