• Title/Summary/Keyword: Fixed interference method

Search Result 83, Processing Time 0.033 seconds

Mitigation Techniques of Channel Collisions in the TTFR-Based Asynchronous Spectral Phase-Encoded Optical CDMA System

  • Miyazawa, Takaya;Sasase, Iwao
    • Journal of Communications and Networks
    • /
    • v.11 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • In this paper, we propose a chip-level detection and a spectral-slice scheme for the tunable-transmitter/fixed-receiver (TTFR)-based asynchronous spectral phase-encoded optical codedivision multiple-access (CDMA) system combined with timeencoding. The chip-level detection can enhance the tolerance of multiple access interference (MAI) because the channel collision does not occur as long as there is at least one weighted position without MAI. Moreover, the spectral-slice scheme can reduce the interference probability because the MAI with the different frequency has no adverse effects on the channel collision rate. As a result, these techniques mitigate channel collisions. We analyze the channel collision rate theoretically, and show that the proposed system can achieve a lower channel collision rate in comparison to both conventional systems with and without the time-encoding method.

Frequency and Subcarrier Reuse Partitioning for FH-OFDMA Cellular Systems

  • Lee, Yeonwoo;Kim, Kyung-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.16 no.5
    • /
    • pp.601-609
    • /
    • 2013
  • One of the most serious factors constraining the next generation cellular mobile consumer communication systems will be the severe co-channel interference experienced at the cell edge. Such a capacity-degrading impairment combined with the limited available spectrum resource makes it essential to develop more spectrally efficient solutions to enhance the system performance and enrich the mobile user's application services. This paper proposes a unique hybrid method of frequency hopping (FH) and subcarrier-reuse-partitioning that can maximize the system capacity by efficiently utilizing the available spectrum while at the same time reduce the co-channel interference effect. The main feature of the proposed method is that it applies an optimal combination of different frequency reuse factors (FRF) and FH-subcarrier allocation patterns into the partitioned cell regions. From the simulation results, it is shown that the proposed method can achieve the optimum number of subcarrier subsets according to the frequency-reuse distance and results in better performance than the fixed FRF methods, for a given partitioning arrangement. The results are presented in the context of both blocking probability and BER performances. It will also be shown how the proposed scheme is well suited to FH-OFDMA based cellular systems aiming at low co-channel interference performance and optimized number of subcarriers.

An Efficient Channel Search Method for Transmitting Massive Multimedia Data (대용량 멀티미디어 데이터 전송을 위한 효율적인 채널 검색 방법)

  • Chung, Kyung Taek;Go, Sung Hyun
    • Smart Media Journal
    • /
    • v.9 no.4
    • /
    • pp.170-175
    • /
    • 2020
  • It is important to select the most appropriate channel for efficient transmission of massive multimedia data between smart devices in wireless sensor network. In the fixed channel method, sensor nodes can restrict usefulness of frequency and may be a major constraint to support frequency at various environments. In this paper, we propose a modified efficient channel search algorithm that determines available channel and tolerance of interference of links between two nodes. From the results of computer simulation, the proposed method shows that the link of channel can be set efficiently than the other methods even if the number of interference links increases and the beacon packet waiting time caused by interference is reduced remarkably.

Codebook-Based Precoding for SDMA-OFDMA with Spectrum Sharing

  • Jo, Han-Shin
    • ETRI Journal
    • /
    • v.33 no.6
    • /
    • pp.831-840
    • /
    • 2011
  • This paper focuses on codebook-based precoding for space-division multiple access/orthogonal frequency-division multiple access (SDMA-OFDMA) systems aiming to guarantee high throughput for their users as well as to mitigate interference to fixed satellite service (FSS). A systematic design of SDMA codebook for subband-based OFDMA is proposed, which forms multiple orthogonal beams with common spatial null in the direction of a victim FSS earth station (ES). The design enables both transmitter and receiver to independently construct identical codebook by sharing only on the direction angle of an FSS ES, which takes fewer overhead bits than Gram-Schmidt process, a general method satisfying our design criterion. A system-level throughput evaluation shows that the proposed precoding provides superior performance over existing spectrum sharing method, that is, subband deactivation. The spectrum sharing analysis shows that the proposed precoding, even with an estimation error of the direction angles of an FSS ES, causes lower interference than existing precoding, knockdown precoding.

The Posterior Cruciate Ligament (PCL) Reconstruction by the Transtibial Tunnel Method using Cadaveric Achilles Tendon Grafts - Evaluation of the Initial Lengthening and the Slippage Ratio due to the Interference Screw Fixation and Double Cross-Pin Fixation - (사체 아킬레스건을 이용한 경골관통터널방식의 후방십자인대 재건술 - 간섭나사 및 이중고정핀 방식에 따른 초기연신 및 활주율 평가 -)

  • Kim, Cheol-Woong;Bae, Ji-Hoon;Oh, Dong-Joon
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.33 no.4
    • /
    • pp.430-439
    • /
    • 2009
  • Posterior Cruciate Ligament (PCL) plays an important role in knee extension. Rotational instability due to injured PCL can be restored by various PCL reconstruction methods. In this study, the initial lengthening affected by fixation device and location was demonstrated, and furthermore, the slippage and the relationship between lengthening ratio and slippage ratio in the calcaneus and soft tissue fixation methods was newly suggested. Eight specimens of proximal tibia and Achilles tendon grafts were harvested from four cadavers and divided into four groups in regard to the four different types of transtibial fixation techniques. The cyclic load ranged from 50 N to 250 N applied to each graft fixed to proximal tibia in 55 degrees. The initial lengthening ratio to the total elongation has been approximately constant regardless of the fixation methods. The soft tissue fixation method with an interference screw showed about 56.4% slippage ratio to the total elongation and the same method with a double cross-pin presented about 45.4% slippage ratio. The soft tissue fixation method with an interference screw demonstrated approximately 2 mm less total elongation and about 13% more slippage than lengthening because of poor fixation compared to the same method with a double cross-pin.

The Investigation of a Novel Indicator System for Trace Determination and Speciation of Selenium in Natural Water Samples by Kinetic Spectrophotometric Detection

  • Gurkan, Ramazan;Ulusoy, Halil Ibrahim
    • Bulletin of the Korean Chemical Society
    • /
    • v.31 no.7
    • /
    • pp.1907-1914
    • /
    • 2010
  • A novel catalytic kinetic method is proposed for the determination of Se(IV), Se(VI) and total inorganic selenium in water based on the catalytic effect of Se(IV) on the reduction of bromate by p-nitrophenylhydrazine at pH 3.0. The generated bromine, $Br_2$ or $Cl_2$ plus $Br_2$ in 0.1 M NaCl (or NaBr) environment efficiently decolorized Calmagite and the reaction was monitored spectrophotometrically at 523 nm as a function of time. In this indicator reaction, bromide acted as an activator for the catalysis of selenium (IV) and a reducing agent for selenium (VI) at pH 3.0, which allowed the determination of total selenium. The fixed time method was adopted for the determination and speciation of inorganic selenium. Under the optimum conditions, the calibration graph are linear in the range 1 - 35 ${\mu}gL^{-1}$ of Se(IV) for the fixed time method at $25^{\circ}C$. The detection limit based on statistical $3S_{blank}$/m-criterion was 0.215 ${\mu}gL^{-1}$ for the fixed time method (7 min). All of the variables that affect the sensitivity at 523 nm were investigated, and the optimum conditions were established. The interference effect of various cations and anions on the Se (IV) determination was also studied. The selectivity of the selenium determination was greatly improved with the use of the strongly cation exchange resin such as Amberlite IR120 plus. The proposed kinetic method was validated statistically and through recovery studies in natural water samples. The RSDs for ten replicate measurements of 5, 15 and 25 ${\mu}gL^{-1}$ of Se(IV) and Se(VI) was changed between 2.1 - 4.85%. Analyses of a certified standard reference material (NIST SRM 1643e) for selenium using the fixed-time method showed that the proposed kinetic method has good accuracy. Se(IV), Se(VI) and total inorganic selenium in environmental water samples have been successfully determined by this method after selective reduction of Se(VI) to Se(IV).

A Study on Calculation of Protection Ratio for Interference Analysis in Fixed Radio Relay Networks (고정 무선중계 망의 간섭 분석을 위한 보호비 계산에 대한 연구)

  • Suh Kyoung-Whoan;Lee Joohwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.1 s.343
    • /
    • pp.133-142
    • /
    • 2006
  • This paper suggests an efficient method of protection ratio(PR) calculation and shows some results of point-to-point radio relay system for frequency coordination. The proposed PR can be expressed as a function of C/N of modulation scheme, noise-to-interference ratio(N/I), multiple interference allowance, fade margins of multi-Path and rain attenuation and net filter discrimination. And PR calculation is performed in view of fade margin, modulation scheme, distance, and interference for actual point-to-point radio relay frequency. According to results for 6.2 GHz, 64-QAM and 60 km at BER 10-6, fade margin and co-channel Protection ratio reveal 41.1dB and 74.9 dB, respectively The merit of presented method provides a systematic and easy calculation by means of PR correction factor related with various parameters and can apply the same concept to frequency coordination of millimeter wave radio relay system.

A Channel Assigmnent Algorithm by Controlling the Transmitted Power Level which is based on the Distance between the Cell Site and the Mobile Unit (이동국과 기지국간의 거리에 따라 송신전력을 제어하는 채널할당 알고리즘)

  • 박덕규
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.1 no.1
    • /
    • pp.47-54
    • /
    • 1997
  • New algorithms for frequency channel assignment in small cellular mobile radio system are proposed. The algorithms are for a channel assignment method which control the transmitter power level based on the distance between the cell site and the mobile unit. These algorithms are such that any channel can be used by any cell site and mobile unit, as long as a required threshold level of carrier to interference ratio is maintained. As the cochannel reuse distance decreases, the proposed algorithms have given an increase in capacity in comparison to a fixed channel assignment.

  • PDF

LONGEVITY AND FAILURE ANALYSIS OF FIXED RESTORATIONS SERVICED IN KOREA (국내에서 제작된 고정성 보철물의 수명과 실패 요인 및 양상)

  • Shin Woo-Jin;Jeon Young-Sik;Lee Keun-Woo;Lee Ho-Yong;Han Dong-Hoo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.158-175
    • /
    • 2005
  • Statement of problem. Every effort has been continually made to obtain objectivity in measuring the longevity of fixed restorations, such as by establishing unified judgement standard for deciding success and adopting statistical method that analyzes the data of successful and failed cases at the same time. In Korea, however desired level of development has not to be made in this field yet. Purpose. This study, adopting California Dental Association (CDA) quality evaluation system, established objective standard for deciding success, and inferred the longevity of fixed restorations and their failure analysis through adopting Kaplan-Meier survival analysis. Material and method. In order to assess the longevity of flxed restorations serviced in Korea and causes of failure, a total of 1109 individuals (aged 15-74, 716 women and 393 men loaded with 2551 unit fixed restorations, and 1934 abutments) who lived in Kyung-In Province were examined and the findings were as follows : Results. 1. Length of service of fixed restorations serviced in Korea was 6.86$\pm$0.15 yr (mean), 5.5 yr (median), and the rate of success was 65.82% in 5 year survival, and 21.15% in 10 year survival. 2. When there was patient's need for replacing old prosthetics, longevity of fixed restorations was 7.51$\pm$0.27 yr (mean), 7 yr (median), and the rate of success was 61.08% in 5 year survival, and 17.57% in 10 year survival. 3. Longevity of fixed restorations was longest in the over-sixty age group(9.21$\pm$0.66) and that of the teen age group(3.39$\pm$0.28) was shortest (p<0.05). 4. Longevity of fixed restorations of women (7.38$\pm$0.18 years) was longer than that of men (6.00$\pm$0.26) (p<0.05). 5. As for the provider factor (such as unlicensed performers, university hospitals, and private clinic), there was no statistically significant difference in longevity of fixed restorations. 6. Defective margin (34.78%). periodontal disease (12.15%), periapical involvement (11.73%), was the most frequent causes of failure and poor esthetics group showed the longest life above all (p<0.05). Actual frequent causes of failure after removing old prosthetics were defective margin, periapical involvement, periodontal disease and uncemented restoration. In 75.67% of the cases, abutment state after removing old prosthetics was good enough for loading another prosthetics. 7. There was found to have statistically significant influence between longevity of single crown (6.35$\pm$0.20 yr) and that of 3 unit fixed restorations (7.60$\pm$0.30 y) (p<0.05). In each case the most frequent cause of failure was defective margin. 8. The number of cantilever pontic, pontic/abutment ratio, oral hygiene status were found to have no statistically significant influence on longevity of fixed restorations in all groups (p>0.05). 9. Longevity of fixed restorations made of non precious metal was longest (9.60$\pm$0.40 yr) semi precious and precious trailing behind(p<0.05). 10. Group function group (37.04%) and partial group function group (44.62%) were predominant in frequency but showed no correlation between them and among different types of occlusal plane and different types of occlusal surface (p>0.05). 11. Longevity of fixed restorations was longest in the centric interference group(9.35$\pm$0.62) (p<0.05) among different types of occlusal interference. Conclusion. We found that longevity of fixed restorations serviced in Korea is affected by age, gender and type of material, and that most frequent cause of failure is defective margin. In order to assess the accurate longevity of axed restorations, unified research design. overcoming inter-observer difference and establishing the objective research items are needed. Furthermore, it is thought that prospective approach through thorough study and regular follow-ups is needed just from the start of research. Nationwide detailed studies on length of service of fixed restorations manufactured in Korea are hoped to be conducted hereafter.

Study on the Effectiveness Analysis Method for the Fixed Linear Arrays System (고정형 선배열 음탐기 체계를 위한 효과도 분석 기법 연구)

  • Kim Jeong-Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.7 no.2 s.17
    • /
    • pp.32-40
    • /
    • 2004
  • In this paper, a simulation model for FLAS(Fixed Linear Arrays System) is presented and methods for effectiveness analysis are studied to analyze the valid target detection effectiveness of this system. The simulation model is constructed taking the FLAS operational specification into account, and thus the change in system specification is effectively reflected on the simulation results. The computational burden is reduced by using the pre-processed simulation parameters which are calculated from the real environmental database. Also, the cell effectiveness and TMOE(Total Measurement of Effectiveness) are computed. The target detection effectiveness of FLAS can be simulated under the multiple target interference simulation. It is shown that the presented algorithm is suitable for the underwater system which needs the simulation model for the optimum system design.