• 제목/요약/키워드: Fixed detector

검색결과 157건 처리시간 0.025초

반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구 (A Study on the Classification of Domestic Fire Detector using Response Time Index)

  • 홍성호;김동석;최기옥
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.

금속-절연체 전이 임계온도센서를 이용한 보상식 화재 감지기 개발 (Development of Compensation-Type Fire Detector Using Metal-Insulator-Transition Critical-Temperature Sensor)

  • 정순규;김현탁
    • 한국화재소방학회논문지
    • /
    • 제28권1호
    • /
    • pp.26-30
    • /
    • 2014
  • 보상식 화재 감지기는 일정한 온도 상승률 이상으로 빠르게 상승하는 경우에 작동하는 차동식 화재 감지기의 기능과 정온점에 이르렀을 때 작동하는 정온식 화재 감지기의 기능을 모두 가진 감지기다. 이 화재 감지기는 정온점 이하에서 발생하는 화재를 감지하지 못하는 정온식 화재 감지기의 단점과 불꽃없이 천천히 타는 현상과 같이 천천히 열이 증가하는 화재를 감지하지 못하는 차동식 화재 감지기의 단점을 보완하기 위해 개발된다. 이것을 위해 우리는 이 감지기의 센서로 금속-절연체 전이 임계온도센서를 이용했는데 이 센서의 감도를 결정하는 저항온도계수가 $55^{\circ}C$일 때 14.15%로써, 서미스터(약 0.5%)보다 큰 값이다. 이 센서는 하나의 센서가 정온점 이하에서는 차동 기능, 정온점 이상에서는 정온 기능을 모두 가진다.

천장제트기류에 대한 국내 정온식 열감지기의 작동온도 및 반응시간지수(RTI)에 관한 DB 구축 (DB Construction of Activation Temperature and Response Time Index for Domestic Fixed-temperature Heat Detectors in Ceiling Jet Flow)

  • 윤가영;한호식;문선여;박충화;황철홍
    • 한국화재소방학회논문지
    • /
    • 제34권3호
    • /
    • pp.35-42
    • /
    • 2020
  • 성능위주 소방설계(PBD)의 안전성 평가 과정에서 화재모델링의 신뢰성 확보를 위해서는 화재감지기 작동시간의 정확한 예측성능이 요구된다. 본 연구는 대표적 화재모델인 FDS에 적용되는 정온식 열감지기의 주요 입력인자인 감지기 작동온도와 RTI의 측정을 목표로 한다. 이를 위해 화재감지기 실험 장치인 Fire detector evaluator (FDE)가 적용되었으며, 제품 인지도 조사를 통해 선정된 국내 10종의 정온식 감지기가 고려되었다. 결과적으로 감지기의 제조사별로 작동온도와 RTI는 상당한 차이가 있는 것으로 확인되었으며, 측정된 DB가 적용된 FDS의 감지기 작동시간은 보다 정확한 예측이 가능함을 확인하였다. 최종적으로 신뢰성이 확보된 정온식 열감지기의 작동온도와 RTI의 DB가 제공되었다.

정온식 열감지기의 응답시간지수 및 작동시간 (Response Time Index and Operation Time of Fixed Temperature Heat Detector)

  • 류호철;태순호;이병곤
    • 한국화재소방학회논문지
    • /
    • 제7권1호
    • /
    • pp.11-16
    • /
    • 1993
  • Fixed temperature heat detectors that respond to the heat generated in fire plume and alarm when the temperature reaches a specified point, give a great influences to the loss of life and property according to their reaction sensitivity. In this study, hot wind tunnel tests and compartment fire experiments were performed to investigate the response time and temperature of fixed temperature heat detector. As a result, simple equations were derived which can be predicted the response time and temperature of the fixed temperature heat detector for the ramp type fire. Also other useful data, such as the effective temperature, time constant, response time index(RTI) were obtained.

  • PDF

견관절 Superoinferior axial 검사 시 Tiltable standing detector의 유용성에 관한 고찰 (Study of the Usefulness of Tiltable standing detector in Testing Shoulder Joint Superoinferior axial)

  • 이동희;김병기;김기정;김민현;이민우;김순배;김경수
    • 대한디지털의료영상학회논문지
    • /
    • 제11권1호
    • /
    • pp.27-33
    • /
    • 2009
  • In this study, we compared the alteration of test positions according to various test equipments when testing shoulder joint superoinferior axial to estimate the clinical usefulness of tiltable standing detector. Our objectives were patients who visited our hospital. Among them we chose patients who were prescribed to get a shoulder axial test, again we selected 30 patients whose abduction is more than 90 degree.(2008. Nov.$\sim$2009 Jan.) With the patients cooperation, we used CR(Agfa, Belgium), fixed-detector(Canon, japan), Tiltable-detector(Philips, Netherlands). Tested with only one equipment(tiltable detector), and posed with the other two. We surveyed 5 inspectors and 30 patients, asking them to rate the convenience of test position. Also, we checked how long it takes to have the image appear on screen after testing with the equipment We provided a standard for an assessment of the image to an expert in bone radiology, an orthopedist and a radiologist with 5 years experience. When the patients were asked about the convenience of the equipments, 15 people(50%) answered CR is convenient and 14 people(46.7%) answered the Tilting detector is convenient, showing not much difference. However, when the inspectors were asked the same question, 4people(80%) out of 5 answered that the Tilting detector is more convenient The time test showed that CR takes 2 minutes and 50 seconds, the Fixed detector 1minute and 48 seconds andor had no distortion showing the shoulder joint space. However, even though the Fixed detector showed ac the Tilting detector takes 1 minute and 43 seconds to bring the image to the screen after the position. The results of the value of image taken by each equipment, CR and the Tilting detectromion, coracoid process, due to the unstable pose, they were quite distorted and scored poor in observing glenoid fossa. By this study, we can see that testing the shoulder joint superoinferior axial projection with a detector that has a tilting device would be more convenient than testing it with a CR.

  • PDF

랙크식 물류창고 조기 화재감지를 위한 최적 화재감지기 설치방법에 관한 실험연구 (An Experimental Study on the Optimum Installation of Fire Detector for Early Stage Fire Detecting in Rack-Type Warehouses)

  • 최기옥;김동석;홍성호
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.38-45
    • /
    • 2017
  • This paper is an experimental study to find an optimal detection method for detecting fire early in a rack-type warehouse stored with goods. In this study, we constructed rack-type structure with the fourth floor of 13.5 m high and conducted fire experiments which were to measure flow of heat/smoke in rack-type structure and response time of fire detectors. The detectors used at experiments were fixed temperature type detectors, rate of rise detectors, photoelectric smoke detectors, air sampling smoke detectors and flame detectors. The used ignition sources are n-heptane fire for response of heat detection and cotton fire for response of smoke detection. The fixed temperature type detectors, rate of rise detectors and photoelectric detectors were installed to every rack level respectively. The results show that the rate of rise detector should be installed every 2 levels and photoelectric smoke detector should be installed every 4 levels for the early stage fire detection. Air sampling smoke detectors can detect fire early in response to control of sensitivity, but there is a problem in false alarm. The fixed temperature detector is not suitable for early stage fire detection in warehouse and flame detector not worked if flame is not visible, so it need to install combination with other detector.

심볼간 간섭 채널을 위한 고정 지연 신호 검출기 (Fixed Decision Delay Detector for Intersymbol Interference Channel)

  • Taehyun, Jeon
    • 대한전자공학회논문지TC
    • /
    • 제41권9호
    • /
    • pp.39-45
    • /
    • 2004
  • 순차적인 관찰값을 바탕으로 하고 신호검출에 소요되는 시간이 고정된 신호검출기의 제작에 관한 방법을 제안하며 이는 하드웨어의 복잡도를 감소시키는 장점이 있다. 제안된 방법은 Voronoi 다이어그램과 Delaunay 분할을 사용한다. 제안된 신호검출기 제작은 또한 고정 지연 트리 검색 검출 (FDTS) 방법에 기반을 둔다. FDTS 는 효율적인 순차적 신호검출 알고리즘이며 심볼간 간섭이 존재하는 채널에서 결정 궤환 등화기법 (DFE)과 결합하여 최적화에 근접한 성능을 보인다. 이러한 접근방법에서는 Voronoi 다이어그램 혹은 등가적으로 Delaunay 분할에 포함된 정보를 활용하여 다차원 유클리드 공간에서의 상대적인 관찰값의 위치를 계산하며 이러한 방법이 효율적인 계산을 유도하는 신호검출기의 제작에 이용된다.

2개의 AMR 센서를 이용한 무선 차량 검지기에 대한 현장시험 및 평가 (Field Test and Evaluation for a Wireless Vehicle Detector with Two Anisotropic Magneto-Resistive Sensors)

  • 강문호
    • 전기학회논문지
    • /
    • 제60권3호
    • /
    • pp.600-605
    • /
    • 2011
  • This paper shows field test and evaluation results for a wireless vehicle detector with anisotropic magneto-resistive (AMR) sensors. The detector consists of two AMR sensors and mechanical and electronic apparatuses. The AMR sensor senses disturbance of the earth magnetic field caused by a vehicle moving over the sensor and then produces an output indicative of the moving vehicle. In this paper, vehicle speeds are calculated by using two AMR sensors fixed on a board, with constant distance. To test and evaluate the accuracy of the detector in real traffic situations, the detector was installed on a local highway and vehicle speeds and volumes were measured both in a free running and a highly congested traffic. The measurements from the detector are compared with the reference measurements obtained from a traffic camera with the Mean Absolute Percentage Errors (MAPE), which has proved the usefulness of the detector in the field.

열방출률을 이용한 열감지기의 오동작 경계값 분석 (An Analysis of False Alarm Threshold Value by Heat Detector Using Heat Release Rate)

  • 홍성호;김두현
    • 한국화재소방학회논문지
    • /
    • 제17권3호
    • /
    • pp.26-30
    • /
    • 2003
  • 본 논문은 화재발생시 열감지기가 오동작하는 특성을 열방출률(Heat Release Rate : HRR)을 이용하여 경계값을 정량적으로 나타내고 그 경계값을 기준으로 감지기의 오동작 영역을 분석하였다. Crib 형태의 목재를 가지고 small-scale의 화재실험을 통하여 화재감지기의 동작시간 등을 측정하였고 이를 이용하여 화재감지기가 동작하는 순간의 HRR을 계산하였다. 화재실험으로부터 얻은 변수를 가지고 화재감지기가 오동작하는 HRR의 경계값을 계산한 결과 정온식 감지기는 20.24 kW 차동식 감지기는 13.59 kW로 나타났다.