• Title/Summary/Keyword: Fixed detector

Search Result 156, Processing Time 0.031 seconds

A Study on the Classification of Domestic Fire Detector using Response Time Index (반응시간지수(Response Time Index)를 이용한 국내 화재감지기 등급분류에 관한 연구)

  • Hong, Sung Ho;Kim, Dong Suck;Choi, Ki Ok
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.46-51
    • /
    • 2017
  • This paper presents classification of domestic fire detector using response time index. Response time is measured using fire detector distributed in Korea, and the response time index is estimated. Plunge test prescribed by FM is conducted to measure response time of fire detector. The detector used to test is fixed temperature type(thermistor and bimetal type) and rate of rise temperature type(thermistor and pneumatic type). The nominal operation temperature of fixed temperature type detector is $70^{\circ}C$ and rate of rise temperature is $15^{\circ}C/min$. The fixed temperature type is measured 7 products, and the rate of rise temperature type is measured 5 products. The results show that in case of fixed temperature type(thermistor) is classified "Quick" or "Standard" and fixed temperature type(bimetal) is not classified. The rate of rise temperature type(thermistor) is classified "Fast" or "Ultra Fast" and the rate of rise temperature type(pneumatic) is classified "Very Fast" or "Ultra Fast". The pneumatic type shows more fast response than thermistor type. Also these results indicate the fixed temperature type(bimetal) is not suitable for early stage fire detection.

Development of Compensation-Type Fire Detector Using Metal-Insulator-Transition Critical-Temperature Sensor (금속-절연체 전이 임계온도센서를 이용한 보상식 화재 감지기 개발)

  • Jung, Sun-Kyu;Kim, Hyun-Tak
    • Fire Science and Engineering
    • /
    • v.28 no.1
    • /
    • pp.26-30
    • /
    • 2014
  • A Compensation-type fire detector (CFD) is operated with two functions of a differential-temperature detector and as a fixed-temperature detector. The differential-temperature detector observes a rate of temperature increase, and the fixed-temperature detector measures a given fixed temperature. The differential-temperature detector does not observe the outbreak of fire in slowly increasing temperature conditions, whereas the fixed-temperature detector is not able to observe the outbreak of fire in conditions under predetermined temperature level. We developed a CFD to compensate for weaknesses of both detectors. To compensate for the disadvantages, a sensor of the sensor metal-insulator-transition critical-temperature sensor was used. Temperature coefficient of resistance is the sensitivity for sensor. At $55^{\circ}C$, temperature coefficient of resistance of metal-insulator-transition critical-temperature sensor was 14.15%. Temperature coefficient of resistance of thermistor was about 0.5%. This CFD was operated as two ways that fixed-temperature detector and differential-temperature detector in one sensor.

DB Construction of Activation Temperature and Response Time Index for Domestic Fixed-temperature Heat Detectors in Ceiling Jet Flow (천장제트기류에 대한 국내 정온식 열감지기의 작동온도 및 반응시간지수(RTI)에 관한 DB 구축)

  • Yoon, Ga-Yeong;Han, Ho-Sik;Mun, Sun-Yeo;Park, Chung-Hwa;Hwang, Cheol-Hong
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.35-42
    • /
    • 2020
  • The accurate prediction of fire detector activation time is required to ensure the reliability of fire modeling during the safety assessment of performance-based fire safety design. The main objective of this study is to determine the activation temperature and the response time index (RTI) of a fixed heat detector, which are the main input factors of a fixed-temperature heat detector applied to the fire dynamics simulator (FDS), a typical fire model. Therefore, a fire detector evaluator, which is a fire detector experimental apparatus, was applied, and 10 types of domestic fixed-temperature heat detectors were selected through a product recognition survey. It was found that there were significant differences in the activation temperature and RTI among the detectors. Additionally, the detector activation time of the FDS with the measured DB can be predicted more accurately. Finally, the DB of the activation temperature and RTI of the fixed-temperature heat detectors with reliability was provided.

Response Time Index and Operation Time of Fixed Temperature Heat Detector (정온식 열감지기의 응답시간지수 및 작동시간)

  • 류호철;태순호;이병곤
    • Fire Science and Engineering
    • /
    • v.7 no.1
    • /
    • pp.11-16
    • /
    • 1993
  • Fixed temperature heat detectors that respond to the heat generated in fire plume and alarm when the temperature reaches a specified point, give a great influences to the loss of life and property according to their reaction sensitivity. In this study, hot wind tunnel tests and compartment fire experiments were performed to investigate the response time and temperature of fixed temperature heat detector. As a result, simple equations were derived which can be predicted the response time and temperature of the fixed temperature heat detector for the ramp type fire. Also other useful data, such as the effective temperature, time constant, response time index(RTI) were obtained.

  • PDF

Study of the Usefulness of Tiltable standing detector in Testing Shoulder Joint Superoinferior axial (견관절 Superoinferior axial 검사 시 Tiltable standing detector의 유용성에 관한 고찰)

  • Lee, Dong-Hee;Kim, Byung-Ki;Kim, Ki-Jung;Kim, Min-Hyun;Lee, Min-Woo;Kim, Sun-Bae;Kim, Gyeong-Soo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.11 no.1
    • /
    • pp.27-33
    • /
    • 2009
  • In this study, we compared the alteration of test positions according to various test equipments when testing shoulder joint superoinferior axial to estimate the clinical usefulness of tiltable standing detector. Our objectives were patients who visited our hospital. Among them we chose patients who were prescribed to get a shoulder axial test, again we selected 30 patients whose abduction is more than 90 degree.(2008. Nov.$\sim$2009 Jan.) With the patients cooperation, we used CR(Agfa, Belgium), fixed-detector(Canon, japan), Tiltable-detector(Philips, Netherlands). Tested with only one equipment(tiltable detector), and posed with the other two. We surveyed 5 inspectors and 30 patients, asking them to rate the convenience of test position. Also, we checked how long it takes to have the image appear on screen after testing with the equipment We provided a standard for an assessment of the image to an expert in bone radiology, an orthopedist and a radiologist with 5 years experience. When the patients were asked about the convenience of the equipments, 15 people(50%) answered CR is convenient and 14 people(46.7%) answered the Tilting detector is convenient, showing not much difference. However, when the inspectors were asked the same question, 4people(80%) out of 5 answered that the Tilting detector is more convenient The time test showed that CR takes 2 minutes and 50 seconds, the Fixed detector 1minute and 48 seconds andor had no distortion showing the shoulder joint space. However, even though the Fixed detector showed ac the Tilting detector takes 1 minute and 43 seconds to bring the image to the screen after the position. The results of the value of image taken by each equipment, CR and the Tilting detectromion, coracoid process, due to the unstable pose, they were quite distorted and scored poor in observing glenoid fossa. By this study, we can see that testing the shoulder joint superoinferior axial projection with a detector that has a tilting device would be more convenient than testing it with a CR.

  • PDF

An Experimental Study on the Optimum Installation of Fire Detector for Early Stage Fire Detecting in Rack-Type Warehouses (랙크식 물류창고 조기 화재감지를 위한 최적 화재감지기 설치방법에 관한 실험연구)

  • Choi, Ki Ok;Kim, Dong Suck;Hong, Sung Ho
    • Journal of the Korean Society of Safety
    • /
    • v.32 no.2
    • /
    • pp.38-45
    • /
    • 2017
  • This paper is an experimental study to find an optimal detection method for detecting fire early in a rack-type warehouse stored with goods. In this study, we constructed rack-type structure with the fourth floor of 13.5 m high and conducted fire experiments which were to measure flow of heat/smoke in rack-type structure and response time of fire detectors. The detectors used at experiments were fixed temperature type detectors, rate of rise detectors, photoelectric smoke detectors, air sampling smoke detectors and flame detectors. The used ignition sources are n-heptane fire for response of heat detection and cotton fire for response of smoke detection. The fixed temperature type detectors, rate of rise detectors and photoelectric detectors were installed to every rack level respectively. The results show that the rate of rise detector should be installed every 2 levels and photoelectric smoke detector should be installed every 4 levels for the early stage fire detection. Air sampling smoke detectors can detect fire early in response to control of sensitivity, but there is a problem in false alarm. The fixed temperature detector is not suitable for early stage fire detection in warehouse and flame detector not worked if flame is not visible, so it need to install combination with other detector.

Fixed Decision Delay Detector for Intersymbol Interference Channel (심볼간 간섭 채널을 위한 고정 지연 신호 검출기)

  • Taehyun, Jeon
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.41 no.9
    • /
    • pp.39-45
    • /
    • 2004
  • A design method is proposed for the sequence detection with fixed decision delay with less hardware complexity using the concept of the Voronoi diagram and its dual, the Delaunay tessellation. This detector design is based on the Fixed Delay Tree Search (FDTS) detection. The FDTS is a computationally efficient sequence detection algerian and has been shown to achieve near-optimal performance in the severe Intersymbol Interference (ISI) channels when combined with decision feedback equalization and the appropriate channel coding. In this approach, utilizing the information contained in the Voronoi diagram or equivalently the Delaunay tessellation, the relative location of the detector input sequence in the multi-dimensional Euclidean space is found without any computational redundancy, which leads to a reduced complexity implementation of the detector.

Field Test and Evaluation for a Wireless Vehicle Detector with Two Anisotropic Magneto-Resistive Sensors (2개의 AMR 센서를 이용한 무선 차량 검지기에 대한 현장시험 및 평가)

  • Kang, Moon-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.60 no.3
    • /
    • pp.600-605
    • /
    • 2011
  • This paper shows field test and evaluation results for a wireless vehicle detector with anisotropic magneto-resistive (AMR) sensors. The detector consists of two AMR sensors and mechanical and electronic apparatuses. The AMR sensor senses disturbance of the earth magnetic field caused by a vehicle moving over the sensor and then produces an output indicative of the moving vehicle. In this paper, vehicle speeds are calculated by using two AMR sensors fixed on a board, with constant distance. To test and evaluate the accuracy of the detector in real traffic situations, the detector was installed on a local highway and vehicle speeds and volumes were measured both in a free running and a highly congested traffic. The measurements from the detector are compared with the reference measurements obtained from a traffic camera with the Mean Absolute Percentage Errors (MAPE), which has proved the usefulness of the detector in the field.

An Analysis of False Alarm Threshold Value by Heat Detector Using Heat Release Rate (열방출률을 이용한 열감지기의 오동작 경계값 분석)

  • 홍성호;김두현
    • Fire Science and Engineering
    • /
    • v.17 no.3
    • /
    • pp.26-30
    • /
    • 2003
  • This paper presents a study on the analysis for false alarm of heat detector using HRR(Heat Release Rate). And it is represented to threshold value and domain of false alarm. The HRR threshold value of false alarm is calculated to use parameters obtained by small scale fire-experiment. The experiment is conducted to measure detector activation time and flame spread of wood cribs fire, etc. The results show that HRR threshold value of Fixed type detector is 20.24 kW and rate of rise type detector is 13.59 kW, respectively.