• Title/Summary/Keyword: Fixed Rate System

Search Result 652, Processing Time 0.026 seconds

Effects of Fixed-intensity and Varied-intensity Electroacupuncture on Heart Rate Variability in Healthy People with Stress Task (고정자극 전침과 변동자극 전침의 정상인 스트레스에 대한 심박변이도 변화 연구)

  • Lim, Sung-Keun;Lee, Dong-Hua;Kwon, You-Jung;Lee, Jeung-Chan;Jung, Chang-Jin;Kim, Yong-Suk;Park, Kyung-Mo;Lee, Sang-Hoon
    • Journal of Acupuncture Research
    • /
    • v.28 no.2
    • /
    • pp.107-116
    • /
    • 2011
  • Objectives : This study was performed to investigate the effects of fixed-intensity and varied-intensity electroacupuncture on heart rate variability in healthy people with stress task. Methods : Forty healthy subjects were randomly assigned to either group A or group B or C. Group A received fixed-intensity electroacupuncture(F-EA) at $ST_{36}$ and $ST_{37}$. After 1 week wash out period to prevent overlapping residual effects, they received varied-intensity electroacupuncture(V-EA) in which the intensity was changed every two minutes based on individual heart rate variability at the same points. Group B received the treatments in reverse order. Group C received no intervention as a control group. Results : Control group showed a significant increase of LF and LF/HF during the 2nd working memory task, while both F-EA and V-EA did not. In addition, V-EA showed a significant increase of HF during 2nd rest while F-EA did not. Conclusions : These results suggest that F-EA and V-EA can inhibit sympathetic activation more than control group and that V-EA can enhance parasympathetic activation more than F-EA.

Control Charts for Constant Failure Rate of System

  • Cho, Gyo-Young;Lee, Ok-Hee
    • Journal of the Korean Data and Information Science Society
    • /
    • v.13 no.2
    • /
    • pp.147-156
    • /
    • 2002
  • In this paper, we propose EWMA control charts using the life time data for the system with the constant failure rate, which were drawn from the fixed sampling interval without replacement(with replacement), and investigate the power of detection of EWMA by comparing ARL of EWMA control charts with one of Shewhart control charts.

  • PDF

Control Charts for Constant Failure Rate of System

  • Cho, Gyo-Young;Lee, Ok-Hee
    • 한국데이터정보과학회:학술대회논문집
    • /
    • 2002.06a
    • /
    • pp.141-149
    • /
    • 2002
  • In this paper, we propose EWMA control charts using the life time data for the system with the constant failure rate, which were drawn from the fixed sampling interval without replacement (with replacement), and investigate the power of detection of EWMA by comparing ARL of EWMA control charts with one of Shewhart control charts.

  • PDF

Biological Treatemnt of Dye Wastewater Using an Anaerobic-Aerobic System (혐기-호기 공정을 이용한 염료페수의 생물학적 처리)

  • 박영식;문정현;안갑환
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.569-576
    • /
    • 2002
  • Anaerobic/aerobic reactor system was used to treat a synthetic wastewater with glucose as carbon sources(0.38~2.29 kg COD/m3.day) and Acid Red 14(1.05 "24.00 g Acid Red 141m3.day, color degree of 570 ~ 1710). COD removal efficiency by the anaerobic stage in operation period were above 90 % organic loading rate of 0.38 ~ 2.29 kg COD/m3.day(except, adaptation period) and the removal efficiency of the whole system were above 96 %. The decolorization of the Acid Red 14 was through the alteration of the dye structure(or cleavage of the Azo bond) during the anaerobic treatment. In the A/A system, the anaerobic stage played an essential role in removing both color and COD. In addition it also improves biodegradability of dye f3r further aerobic treatment. After operation, average MLSS concentration of anaerobic sludge reactor, anaerobic fixed-bed reactor and aerobic fixed-bed reactor were 17100mg/L, 20000mg/L, and 10000mg/L, respectively.

A Study on Fisheries Resource Management Under the Rate Payment System - In Case of Large Trawl Fisheries - (비율(보합) 급제하에서 어업(자원)관리에 관한 연구 - 대형기선저인망어업을 중심으로 -)

  • Park Seong-Kwae
    • The Journal of Fisheries Business Administration
    • /
    • v.36 no.3 s.69
    • /
    • pp.1-24
    • /
    • 2005
  • Korean fishery wage system has been evolved with the different titles. However, Since the law of fishing crew was enacted in 1984, the fishery wage system has been established as a rate system, which is a legal term. The present rate system in practice shows various contents and modalities, depending on fisheries and regions, but the fisheries of large trawl cooperative employ a rate system of fixed plus rate wage. However, such change did not transform basically the properties of pure rate scheme. As well known, fishing vessel owners face an awful lot of difficulty in managing and controlling effectively the production process because fishing activities are carried out in the seas remote from the land. Thus, it tend to be inevitable for vessel owners to employ a rate system to induce fishermen's positive motivation for promoting productivity and saving operating costs. However, the rate system has worked out as a driving force, which induce an increase in production more strongly under the expansion of vessel numbers and power and the keener competition of fishing activities. Even though the control mechanism of fishing instruments are well established, fishermen become naturally to have an incentive to increase their fishing effort for maximizing production since they are able to raise their shares by maximizing the quantity harvested. Thus, as far as the rate system exists, fisheries administration may have much difficulty in realizing its fishery management goals only through vessel reduction and fishing gear regulations. Also, under the rate system fishery management authority may be in face of a serious dilemma between the spontaneous rate system and vessel reduction policy. If the realistic aspect of the rate system is recognized and resource restoration and profit promotion are main policy goals, it is necessary to develop effective ways to control vessel owners' and fishermen's production-maximizing motives at an appropriate level. From this point of view, it seems reasonable to introduce TAC system by species or by fisheries into the existing fishery system. The research results suggest that if the fisheries administration could understand clearly the spontaneous fisheries wage system, it would know the norm of TAC and the basic reasons for illegal fishing activities and thus it would be able to develop and implement more realistic resource management policies.

  • PDF

Study on the Evacuation Time Analysis by Platform Screen Door Opening Rate (스크린도어(PSD)의 개폐율에 따른 피난소요시간 분석에 관한 연구)

  • Kim, Min-Jae;Min, Se-Hong
    • Fire Science and Engineering
    • /
    • v.30 no.4
    • /
    • pp.59-64
    • /
    • 2016
  • The PSD (Platform Screen Door System) has been installed to enhance the passengers' safety. A total of 592 stations operate the PSD system, which is almost 71.8% of all stations in South Korea. This study compared the opening rate between the PSD and train door, and calculated the exact amount of passengers at peak time. In addition, the evacuation time was simulated by Pathfinder 2015 with the exact input data. Some of the high density stations have extremely high dangerous points about the passengers' evacuation at some situations by the PSD door opening rate. In particular, due to the interference of a fixed door, when it stops at 7 m less than the regular position, its opening rate becomes less than half of the normal state. To solve this problem, it should be made possible to open the fixed door by changing it to an emergency door or improving the PSD module system.

Development of High-Ratio Planetary Reduction Gears Applied Differential Ring Gear Type (차동 링기어 방식의 고비율 유성기어 감속기 개발)

  • 박규식;이기명;김유일
    • Journal of Biosystems Engineering
    • /
    • v.22 no.4
    • /
    • pp.497-502
    • /
    • 1997
  • Automation facilities of greenhouses have been continuously developed. However, the conventional two-stage worm gear reducer reveals some problems, including low transmission efficiency. The worm gear reducer also have some difficulties in manufacturing and short life. Therefore, this study was performed to develop a planetary gear reducer, having a high Sear reduction ratio and high torque transmission efficiency. The planetary gear system consisted of a fixed ring gear and a 2-teeth differential ring gear turning slow, as the planetary pinion orbits fast around the fixed ring gear. The developed gear system can achieve a high speed reduction rate at one stage. The reducing system was employed to the greenhouse ventilation system. The reducer has the transmission efficiency of 70.5%, 2∼3 times longer life time, and twofold roll-up torque at an affordable price, comparing with conventional reducers. This reducer can be also applied to many industrial equipments, such as industrial crane, hoist, elevator and gondola etc.

  • PDF

Service-based Competitive Effects in Austrian Fixed Telecommunication Market (호주 유선시장의 서비스기반 경쟁효과)

  • 김병운
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2003.10a
    • /
    • pp.27-30
    • /
    • 2003
  • The introduction of reseller In Australian Fixed Telecommunication Market resulted in the reduction of Telstra's local call market share by 13 percent and average fall rate was reduced. Thus, Telstra increased basic rate at 14.5 percent to compensate loss revenue in the local call market. With the deployment of carrier pre-selection of long distance and international calls, it reduced long distance rate at 23.5 percent and international tall rate at 53 percent, and increased the Churn rate. Therefore, the deployment of service-based competition brought efficient results for long distance and international call market. However, LM market created 13.4 percent reduction in call rates, complications in charge system, technical barriers and the preference of one-bill by customers.

  • PDF

Performance of Flow Rate Control of a Cavitating Venturi (캐비테이션 벤튜리의 유량제어 성능)

  • Cho Won Kook;Moon Yoon Wan;Kim Young-Mog
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2002.05a
    • /
    • pp.146-151
    • /
    • 2002
  • Characteristics of flow rate control has been studied for a cavitating venturi adopted in a liquid rocket propellant feed system. Numerical simulation has been peformed to give about $10\%$ discrepancy of mass flow rate to the experimental data for cavitating flow regime. Mass flow rate is confirmed to be saturated for pressure difference higher than $3\times10^5$pa when the upstream pressure is fixed to $22.8\times10^5$pa and the downstream pressure is varied. The evaporation amount depends substantially to non-condensable gas concentration. However the mass flow rate characteristic is relatively insensitive to the mass fraction of non-condensable gas. So it is reduced by only $2\%$ when the non- condensable gas concentration is increased from 1.5PPM to 150PPM. From the previous comparison the expansions of the non-condensable gas and the evaporation of liquid are verified to have same effect to pressure recovery.

  • PDF

A Study on the Geothermal Heat Pump System Performance Analysis according to Water Flow Rate Control of the Geothermal Water Circulation Pump (지열순환펌프 유량변화에 따른 지열히트펌프시스템의 에너지 성능 평가)

  • Jung, Young-Ju;Jo, Jae-Hun;Kim, Yong-Shik;Cho, Young-Hum
    • Journal of the Korean Solar Energy Society
    • /
    • v.34 no.6
    • /
    • pp.103-109
    • /
    • 2014
  • It is important to control the amount of supply water flow rate at all kinds of HVAC systems in order to maintain IAQ and energy efficiency. The most of buildings installed geothermal heat pumps is using fixed water flow rate in spite of the excellent performance of geothermal heat pumps. Especially when the air-conditioning load is low, the flow rate control may be possible to save energy to operate. However, it is effective to apply the variable flow control system in order to reduce energy consumption. Therefore, the purpose of this study, change a water flow rate and improve the whole performance of the geothermal heat pump. Geothermal heat pump system is modeled after the selection of the applied building, by setting the flow rate control to be analyzed through a simulation of performance evaluation. Building energy saving according to the flow rate of the ground circulating water analyze quantitatively and to investigate the importance of the flow control.