• Title/Summary/Keyword: Fixed Rate System

Search Result 652, Processing Time 0.025 seconds

Performance Analysis of Hybrid SIMO-RF/FSO Communication System with Fixed Gain AF Relay

  • Shi, Wenxiao;Kang, Kai;Wang, Zhuo;Liu, Wei
    • Current Optics and Photonics
    • /
    • v.3 no.5
    • /
    • pp.365-373
    • /
    • 2019
  • This paper investigates the performance of a hybrid single input multiple output radio frequency/free-space optics (SIMO-RF/FSO) communication system. Each SIMO-RF link is modeled as an independent and identically distributed (i.i.d.) Rayleigh distribution, while the FSO link follows a generalized $M{\acute{a}}laga$ (M) distribution. Considering the fixed gain amplify-and-forward (AF) relay and misalignment errors, novel expressions for the outage probability (OP), average bit error rate (ABER) and average capacity are derived. Numerical results show that atmospheric turbulence and misalignment errors can seriously impair the system performance, and the hybrid RF/FSO communication system using SIMO-RF links can greatly improve system performance. We also analyze system performance under different types of modulation schemes. Numerical results are verified by Monte Carlo simulations.

A Study on the Maintenance Policy Considering the Failure Data of the EMU Braking System and the Cost Function (전동차 제동장치의 고장데이터와 비용함수를 고려한 유지보수 정책에 관한 연구)

  • Han, Jae-Hyun;Kim, Jong-Woon;Koo, Jeong-Seo
    • Journal of the Korean Society of Safety
    • /
    • v.30 no.3
    • /
    • pp.13-19
    • /
    • 2015
  • Railway vehicle equipment goes back again to the state just before when failure by the repair. In repairable system, we are interested in the failure interval. As such, a statistical model of the point process, NHPP power law is often used for the reliability analysis of a repairable system. In order to derive a quantitative reliability value of repairable system, we analyze the failure data of the air brake system of the train line 7. The quantitative value is the failure intensity function that was modified, converted into a cost-rate function. Finally we studied the optimal number and optimal interval in which the costs to a minimum consumption point as cost-rate function. The minimum cost point was 194,613 (won/day) during the total life cycle of the braking system, then the optimal interval were 2,251days and the number of optimal preventive maintenance were 7 times. Additionally, we were compared to the cost of a currently fixed interval(4Y) and the optimum interval then the optimal interval is 3,853(won/day) consuming smaller. In addition, judging from the total life, "fixed interval" is smaller than 1,157 days as "optimal interval".

Cooling Simulation for Fixed-Bed of Rough Rice (벼 퇴적층 냉각 시뮬레이션)

  • 김동철;김의웅;금동혁
    • Journal of Biosystems Engineering
    • /
    • v.24 no.1
    • /
    • pp.31-40
    • /
    • 1999
  • The objective of this study were to develop a cooling simulation model for fixed-bed of rough rice and to analyze the factors affecting cooling time of rough rice. A computer simulation model based on equilibrium conditions between grain and air was developed to predict temperature and moisture content changes during cooling of rough rice. the result of t-test showed that there were no significant differences between predicted and measured temperature changes on significance model agreed well with measured values. This cooling simulation model was applied to analyze the effect of some factors, such as air flow rate, cooling air temperature and humidity, initial grain temperature and moisture content, and bed depth, on cooling time of rough rice. Cooling rate increased with increase of air flow rate and bed depth whereas it decreased with increase of cooling air temperature and humidity and initial grain temperature. Among these factors, the most important factor was air flow rate. Specific air flow rate of 0.35㎥/min㎥ was required for cooling rough rice in 24 hours.

  • PDF

Comparison of Aerobic Fixed-film Process Response to Quantitative and Hydraulic Shock for the Same Increases in Mass Loading (호기성 고정생물막반응기에서 동일 질량부하의 수리학적 및 농도충격부하시 반응의 비교)

  • Ahn, Mee-Kyung;Lee, Kyu-Hoon
    • Journal of Environmental Science International
    • /
    • v.3 no.3
    • /
    • pp.285-296
    • /
    • 1994
  • The objective of this study was to examine and compare to transient response to quantitative and hydraulic shocks which produce equal changes in mass rate of organic feed in aerobic fixed-film process. The general experimental approach was to operate the system at several growth rates under steady-state(pre-shock) conditions, then to apply step changes during day 3 in dilution rate(hydraulic shock) , or feed concentration(Quantitative shock) at the same organic mass loading rate. Performance was assessed in both the transient state and the new steady-state (post- shock). Shock load of different type did not produced equivalent disruptions of effluent quality for equal increases in mass loading rate. Based on effluent concentrations, a hydraulic and a Quantitative shock at the same mass loading caused equal increase in total effluent COD, but the increase was primarily a result of suspended solids the hydraulic shock and COD in the quantitative shock. The time which effluent COD came to peak values were about 32~48 hours at the low organic loads and 52 ~ 72 hours at the high organic loads, respectively A quantitative shock produced a much greater increase in effluent COD than did a hydraulic shock at the same mass loading. Mean and peak values of effluent concentration weve increased in 2.8~4.2 times at low organic loading rate, 5.2~6.6 times at the high organic loading rate, respectively. Key words : Aerobic fixed-film reactor, Quantitative shock, hydraulic shock, mass loading rate.

  • PDF

Failure Rate Characteristics Analysis under Ground Mobile and Ground Fixed Environments (지상 기동 및 고정 환경하 고장률 특성 분석)

  • Yun, Hui-Sung;Jeong, Da-Un;Yoon, Jong-Sung;Lee, Seung-Hun
    • Journal of Applied Reliability
    • /
    • v.11 no.3
    • /
    • pp.293-303
    • /
    • 2011
  • Reliability Prediction using MIL-HDBK-217F has some restrictions due to its one modeling basis. One of the restrictions is caused by selecting one operating environment of a system, which is chosen regardless of its detailed conditions, e.g., external impact and vibration. Especially, an equipment, which is installed on a mobile vehicle though its movement is quasi-static, is controversial to designate its environment as ground mobile($G_M$), rather than ground fixed($G_F$). In this paper, failure rates were compared, which are computed using several moving time rates to total operating time. RiAC-HDBK-217Plus was used as the basic calculation model. In addition, $G_F$ conditioned failure rate was evaluated by comparing with that under $G_M$ environment but fixed state.

Energy Saving Potentials of Radiant Floor Heating Systems Based on Control Strategies (바닥 복사 난방 시스템의 제어전략에 따른 에너지 사용량 분석)

  • Lee, Joon-Woo;Park, Cheol-Soo
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.109-114
    • /
    • 2009
  • The dominant heating system used in Korean residential apartment buildings is a hydronic radiant floor heating system, known as the Ondol system. The most common control strategy applied to this traditional hydronic radiant system is a simple on-off control that intermittently supplies "hot water of a fixed temperature" at a "constant flow rate" to each room. However, the current problems with the aforementioned control are as follows: (1) since the simple on-off control is usually based on a one point measured temperature (a signal from a thermostat installed in a living room) in each dwelling unit, heating energy use for unoccupied rooms as well as a difference in temperatures between spaces (master bedroom, living room, bedroom1, bedroom2) can occur occasionally. (2) the most widely used residential water splitter has static valves, and is thus not able to change the flow rate to each room depending on the space heating load. In other words, the ratio of flow rates to rooms is fixed after construction, resulting in over- or under-heating and an improper use of energy. The aim of this paper is therefore to investigate the differences in the system's performance between control strategies in terms of the flow rate control and sensor location. It is shown that energy savings of control strategies are strongly influenced by occupant schedule.

  • PDF

Channel Coding-Aided Multi-Hop Transmission for Throughput Enhancement

  • Hwang, Inchul;Wang, Hanho
    • International Journal of Contents
    • /
    • v.12 no.1
    • /
    • pp.65-69
    • /
    • 2016
  • Wireless communication chipsets have fixed transmission rate and communication distance. Although there are many kinds of chipsets with throughput and distance purpose, they cannot support various types of wireless applications. This paper provides theoretic research results in order to support various wireless applications requiring different throughput, delayed quality-of-service (QoS), and different communication distances by using a wireless communication chipset with fixed rate and transmission power. As a performance metric, the probability for a data frame that successfully receives at a desired receiver is adopted. Based on this probability, the average number of transmission in order to make a successful frame transmission is derived. Equations are utilized to analyze the performance of a single-hop with channel coding and a dual-hop without error correction matter transmission system. Our results revealed that single-hop transmission assisted by channel coding could extend its communication distance. However, communication range extending effect of the single-hop system was limited. Accordingly, dual-hop transmission is needed to overcome the communication distance limit of a chipset.

Switching between Spatial Modulation and Quadrature Spatial Modulation

  • Kim, Sangchoon
    • International journal of advanced smart convergence
    • /
    • v.8 no.3
    • /
    • pp.61-68
    • /
    • 2019
  • Spatial modulation (SM) is the first proposed space modulation technique. By further utilizing the quadrature spatial dimension, quadrature spatial modulation (QSM) has been developed as an amendment to SM system to enhance the overall spectral efficiency. Both techniques are capable of entirely eliminating interchannel interference (ICI) at the receiver. In this paper, we propose a simple adaptive hybrid switching transmission scheme to obtain better system performance than SM and QSM systems under a fixed transmission date rate. The presented modulator selection criterion for switching between spatial modulator and quadrature spatial modulator is based on the larger received minimum distance of spatial modulator and quadrature spatial modulator to exploit the spatial channel freedom. It is shown through Monte Carlo simulations that the proposed hybrid SM and QSM switching system yields lower error performance than the conventional SM and QSM systems under the same fixed data rate and thus can provide signal to noise ratio (SNR) gain.

Performance Improvement of Backpropagation Algorithm by Automatic Tuning of Learning Rate using Fuzzy Logic System

  • Jung, Kyung-Kwon;Lim, Joong-Kyu;Chung, Sung-Boo;Eom, Ki-Hwan
    • Journal of information and communication convergence engineering
    • /
    • v.1 no.3
    • /
    • pp.157-162
    • /
    • 2003
  • We propose a learning method for improving the performance of the backpropagation algorithm. The proposed method is using a fuzzy logic system for automatic tuning of the learning rate of each weight. Instead of choosing a fixed learning rate, the fuzzy logic system is used to dynamically adjust the learning rate. The inputs of fuzzy logic system are delta and delta bar, and the output of fuzzy logic system is the learning rate. In order to verify the effectiveness of the proposed method, we performed simulations on the XOR problem, character classification, and function approximation. The results show that the proposed method considerably improves the performance compared to the general backpropagation, the backpropagation with momentum, and the Jacobs'delta-bar-delta algorithm.

Convolutionally-Coded and Spectrum-Overlapped Multicarrier DS-CDMA Systems in a Multipath Fading Channel

  • Oh, Jung-Hun;Kim, Ki-Doo;Milstein, Laurence B.
    • ETRI Journal
    • /
    • v.23 no.4
    • /
    • pp.177-189
    • /
    • 2001
  • Multicarrier DS-CDMA is an effective approach to combat fading and various kinds of interference. In this paper, we present an overlapped multicarrier DS-CDMA system, wherein each of the rate 1/M convolutionally-encoded symbols is also repetition coded and transmitted using overlapped multicarriers. However, since the frequency spectrums of successive carriers are allowed to overlap, the transmission bandwidth is more efficiently utilized. The effect of the overlapping percentage between successive carriers of a multicarrier DS-CDMA system on the performance is investigated to determine the overlapping percentage showing the best performance. We suggest two methods for sub-band overlapping variation. One is to allow variation of sub-band overlapping percentage when the total number of subcarriers is fixed. The other is to increase the number of sub-bands (the number of repetitions R) with fixed sub-band bandwidth. Given a total number of subcarriers MR, we show that the BER variation is highly dependent on the roll-off factor ${\beta}$ of a raised-cosine chip wave-shaping filter irrespective of convolutional encoding rate 1/M and repetition coding rate 1/R. We also analyze the possibility of reduction in total multi-user interference by considering the variation of both the roll-off factor ($0<{\beta}{\leq}1$) and the sub-band overlapping factor ($0<{\lambda}{\leq}2$), and show that the proposed system may outperform the multicarrier DS-CDMA system in [3].

  • PDF