• Title/Summary/Keyword: Fixed CT

Search Result 133, Processing Time 0.03 seconds

In vitro evaluation methods on adaptation of fixed dental prosthesis (고정성 보철물의 적합도에 대한 실험적 평가방법)

  • Lee, Hyunho;Lee, Du-Hyeong;Lee, Kyu-Bok
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.33 no.2
    • /
    • pp.63-70
    • /
    • 2017
  • Clinically, the fit of fixed prosthesis is an essential element for successful restoration. The fit of prosthesis is largely classified into marginal fit and internal fit, and various methods to assess these have been introduced including microscopic margin measurement, cross-sectional measurement, silicone replica technique, 3-dimensional scanning data superposition, weight technique and micro CT scanning. Thus, this study is aimed at proposing a more convenient and accurate measurement method of fits in a digital environment by comparatively analyzing the advantages and disadvantages of each known method based on existing literature.

A fast DCT algorithm with reduced propagation error in the fixed-point compuitation (고정 소수점 연산시 오차의 전파를 줄이는 고속 이산 여현 변환 알고리즘)

  • 정연식;이임건;최영호;박규태
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.23 no.9A
    • /
    • pp.2365-2371
    • /
    • 1998
  • Discrete cosine transform (DCT) has wide applications in speech and image coding. In this paper, we propose a novel fast dCT scheme with the property of reduced multiplication stages and the smaller number of additions and multiplications. This exploits the symmetry property of the DCT kernel to decompose the N-point dCT to N/2 point, and can be generally applied recursively to $2^{m}$-point. The proposed algorithm has a structure that most of multiplications tend to be performed at final stage, and this reduces propagation of truncation error which could occur in the fixed-point computation. Also the minimization of the multiplication stages further decreases the error.

  • PDF

A Study for Reappearance Acording to the Scan Type, the CT Scanning by a Moving Phantom (팬톰을 이용한 전산화 단층촬영방법에 따른 재현성에 대한 고찰)

  • Choi, Jae-Hyock;Jeong, Do-Hyeong;Suk, Choi-Gye;Jang, Yo-Jong;Kim, Jae-Weon;Lee, Hui-Seok
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.2
    • /
    • pp.123-129
    • /
    • 2007
  • Purpose: CT scan shows that significant tumor movement occurs in lesions located in the proximity of the heart, diaphragm, and lung hilus. There are differences concerning three kinds of type to get images following the Scan type called Axial, Helical, Cine (4D-CT) mode, when the scanning by CT. To know how each protocol describe accurately, this paper is going to give you reappearance using the moving phantom. Materials and Methods: To reconstruct the movement of superior-inferior and anterior-posterior, the manufactured moving phantom and the motor following breathing were used. To distinguish movement from captured images by CT scanning, a localizer adhered to the marker on the motor. The moving phantom fixed the movement of superior-inferior upon 1.3 cm /1 min. The motor following breathing fixed the movement of anterior-posterior upon 0.2 cm /1 min. After fixing each movement, CT scanning was taken by following the CT protocols. The movement of A localizer and volume-reappearance analyzed by RTP machine. Results: Total volume of a marker was 88.2 $cm^3$ considering movement of superior-inferior. Total volume was 184.3 $cm^3$. Total volume according to each CT scan protocol were 135 $cm^3$ by axial mode, 164.9 $cm^3$ by helical mode, 181.7 $cm^3$ by cine (4D-CT) mode. The most closely describable protocol about moving reappearance was cine mode, the marker attached localizer as well. Conclusion: CT scan should reappear concerning a exact organ-description and target, when the moving organ is being scanned by three kinds of CT protocols. The cine (4D-CT) mode has the advantage of the most highly reconstructible ability of the three protocols in reappearance of the marker using a moving phantom. The marker on the phantom has always regular motion but breathing patients don't move like a phantom. Breathing education and devices setting patients were needed so that images reconstruct breathing as exactly as possible. Users should also consider that an amount of radiation to patients is being bombed.

  • PDF

The Study of Influence on Reducing Exposure Dose According to the Applied Flat-panel CT in Extremity Bone SPECT/CT (상·하지 뼈 SEPCT/CT 검사에서 평판형 CT의 피폭저감 영향에 관한 고찰)

  • Kim, Ji-Hyeon;Park, Hoon-Hee;Lee, Juyoung;Nam-Kung, Sik;Son, Hyeon-Soo;Park, Sang-Ryoon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.17 no.2
    • /
    • pp.15-24
    • /
    • 2013
  • Purpose: With the demand of SPECT/CT increasing, the interest in complex diagnostic information of CT is rising along with the expansion of various studies on potential performance value. But the study on reduction of exposure dose generated by CT is not being conducted enough. Therefore, in this study, the goal is to identify how much dose reduction exists when performing the extremity bone SPECT/CT using the flat-panel CT. Materials and Methods: The extremity bone SPECT/CT was performed with two equipments -BrightView XCT (Philips Healthcare, Cleveland, USA) and Brilliance 16 CT (Philips Healthcare, Cleveland, USA)-to identify the exposed dose and image quality resulted by changing scan parameter (mAs) applying for both equipment respectively. The noise value of image and spatial resolution were measured with AAPM CT phantom. Tube voltage (kVp) was fixed to 120 kVp, tube current (mAs) calculated at different mA (20, 30, 40, 50, 60, 70, 80) was applied to both equipments respectively. DLP (dose length product) were calculated at the same distance at respective mAs. Also, we acquired images and % contrast with NEMA IEC body phantom to confirm the effect on image. The output of statistics was analyzed by SPSS ver.18. Results: Regarding AAPM phantom, the noise decreased as the tube current (mAs) increased and flat-panel had less noise than Helical CT. This difference increased at lower dose exposure. As to the evaluation of spatial resolution, we can differentiate the space up to 0.75 mm with both equipments. With scan parameter (mA) growing, the value of DLP increased up to 54-216 mGy cm at flat-panel CT and up to 177-709 mGy cm at Helical CT. Regarding NEMA IEC body phantom, same sphere with varied parameter (mA) shows that similar results. Conclusion: There is no significant differences of image quality in both flat-panel and Helical CT when the scan parameter (mA) is changed respectively. Moreover, we can identify the reduction of exposure dose and confirm %contrast analysis value with maintaining image quality. Therefore, at the extremity bone SPECT/CT requiring high spital resolution without the wide ROI, the flat-panel CT is considered to be more useful and it expected to result in the similar image quality with lower exposure dose compared to Helical CT. Additionally, through this study, we expect to help the reduction of the unnecessary exposure dose.

  • PDF

Effect of UV Sterilization on Quality of Centrifuged Takju during Storage (자외선 살균이 청징 탁주의 저장 중 품질에 미치는 효과)

  • Choi, Eun-Ju;Jung, Jin-Joo;Lee, Jang-Woon;Kang, Sung-Tae
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.39 no.3
    • /
    • pp.461-466
    • /
    • 2010
  • A cylindrical UV sterilization system was developed to decrease microorganisms in centrifuged Takju (CT). CT was run through 110 strips of honey comb type-teflon tubes and 9 UV lamps (1395 W) were equipped between teflon tubes. The optimum sterilization condition of CT was fixed for 1.5 min at 2 L/min in overall quality aspects; also, 5~6 log cycle decrease of viable cell numbers of total bacteria and yeast was observed at this operating condition. Quality changes of UV-sterilized CT were examined by UV irradiation of CT followed by storing at $30^{\circ}C$ for 8 days. To evaluate quality changes of UV-sterilized CT, pH, amino nitrogen content, acidity, reducing sugar content and viable cell numbers of total bacteria and yeast were measured. The growth of yeast and bacteria was retarded, showing around $10^8\;CFU/mL$ even after 4 days and $10^8\;CFU/mL$ after 6 days, respectively. Also, UV sterilized CT showed no changes in pH, titratable acidity, and amino nitrogen content during storage except reducing sugar content. UV sterilization did not cause significant difference in L, a, and b values between CT and UV-sterilized CT over the storage period.

CT and scintigraphic evaluation of osseointegration following immediate versus delayed implantation in dogs (개에서 즉시형과 지연형 인공치아 식립후 골유합에 대한 CT와 신티그라피 평가)

  • Kim, Juoog-Hyun;Lee, Jae Yeong;Lee, Won-Guk;Oh, Won Young;Kim, So-Seob;Kang, Seong Soo;Choi, Seok Hwa
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.1
    • /
    • pp.131-136
    • /
    • 2004
  • Osseointegration involves anchoring dental implants to stable bone rather than to soft-tissue. Clinical osseointegration is currently defined as the process whereby alloplastic material is asymptomatically and rigidly fixed and maintained in bone during functional loading. Full osseointegration is necessary for the success of long-term dental implants. Recent developments in computer assisted measurement of bone formation have improved maxillofacial examination and osseointegration. Computer assisted examination has also proved effective in dental implantology. This investigation was aimed to determine osseointegration in immediate and delayed implantation in the dog mandible using dental computed tomography (CT) and bone scintigraphy. Five adult (mean age of 2 years) mongrel dogs with a mean weight of 9.1 kg were used in this investigation. Titanium alloy implant systems with 4 mm in diameter and 10 mm in length were chosen for insertion. The second and third left mandibular premolars in each dog were extracted for the delayed implant insertion. Twelve weeks later, the second and third right mandibular premolars were extracted for the immediate implant insertion. Before the delayed and immediate implantation procedures and 0, 4, 8, and 12 weeks after the insertions, dental CT and scintigraphy were conducted. The CT and scintigraphic images indicate that reconstruction of bone surrounding of the immediate implant can be as successful as reconstruction of bone surrounding of the delayed implant.

Application of 3D Simulation Surgery to Orbital Wall Fracture : A preliminary Case Study

  • Choi, Jong-Woo
    • Journal of International Society for Simulation Surgery
    • /
    • v.1 no.1
    • /
    • pp.16-18
    • /
    • 2014
  • The orbit has a very special anatomical structure. The complex anatomical structure should be restored when we encounter the patient with orbital wall fracture. Unless these specific anatomy were reconstructed well, the patient should suffer from various complications such enophthalmos, diplopia or orbital deformity. In addition, because the patient has a his own specific orbital shape, individualized approach will be necessary. The aim of this trial is to try to restore the original orbit anatomy as possible based on the mirrored three dimensional CT images based on the computer simulation. Preoperative computed tomography (CT) data were processed for the patient and a rapid prototyping (RP) model was produced. At the same time, the uninjured side was mirrored and superimposed onto the traumatized side, to create a mirror-image of the RP model. In order to restore the missing skipped images between the cuts of CT data because of the thinness of the orbital walls, we manipulated the DICOM data for imaging the original orbital contour using the preoperatively manufactured mirror-image of the RP model. And we fabricated Titanium-Medpor to reconstruct three-dimensional orbital structure intraoperatively. This prefabricated Titanium-Medpor was then inserted onto the defected orbital wall and fixed. Three dimensional approach based on the computer simulation turned out to be very successful in this patient. Individualized approach for each patient could be an ideal way to manage the traumatic patients in near future.

A Case of Interarytenoid Scar Disguising Bilateral Vocal Cord Palsy (양측성 성대 마비로 오인된 피열간 반흔 1예)

  • Shin, Dong-Hyuk;Kim, Yong Won;Lee, Yongsik
    • Journal of the Korean Society of Laryngology, Phoniatrics and Logopedics
    • /
    • v.25 no.1
    • /
    • pp.36-38
    • /
    • 2014
  • The patient suffered cardiac arrest 8 months before presentation. She has been suffering hoarseness and exertional dyspnea and nocturnal stridor. Upon flexible laryngoscopy, her vocal cords showed no motion and fixed in paramedian position. There was no causal finding on neck CT. EMG showed some muscular activity. Under the suspicion of crico arytenoid fixation, we performed suspension laryngoscopy, and found the arytenoid cartilage was fixed with short and stout scar, which was removed with scissors. Just after surgery she regained her voice and respiration.

  • PDF

Estimation and Application of HU Values for Various Materials as a Function of Physical Factor (물리적 인자의 변화에 따른 다양한 구성물질의 하운스필드 단위 평가 및 응용)

  • Lee, Seung-Wan;Kim, Hee-Joung;Kim, Tae-Ho;Jo, So-Jeong;Lee, Chang-Lae
    • Progress in Medical Physics
    • /
    • v.20 no.3
    • /
    • pp.145-151
    • /
    • 2009
  • This study aims to evaluate CT (Computed Tomography) characteristics through the estimation of HU (Hounsfield Unit) and the corresponding variations using coefficient of variation values for various materials as a function of physical factor. HU values for various materials with varying densities as a function of physical factor were measured using MDCT (Siemens SOMATOM Sensation 4, Germany). The results showed that the HU values were decreased and increased as a function of kVp and material density, respectively. Especially, the HU values for bone and iodine at 140 kVp were 32% and 42% smaller than those at 80 kVp, respectively. In case of iodine, the HU values also decreased and increased as a function of kVp and concentration, respectively. While the HU values were fixed as a function of mAs. The decreased ratio of HU values between 80 keV and 140 keV was different at various concentration and maximum difference was shown as 1.73 at 3% concentration. These results indicated that it may be possible to separate composition of materials, e.g. iodine and bone, using single source CT. The results showed that dual energy techniques using single source CT can be applied to material separation and expand CT imaging techniques to other practical applications.

  • PDF

Image Quality Improvement in Computed Tomography by Using Anisotropic 2-Dimensional Diffusion Based Filter (비등방성 2차원 확산 기반 필터를 이용한 전산화단층영상 품질 개선)

  • Seoung, Youl-Hun
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.45-51
    • /
    • 2016
  • The purpose of this study was tried to remove the noise and improve the spatial resolution in the computed tomography (CT) by using anisotropic 2-dimensional (2D) diffusion based filter. We used 4-channel multi-detector CT and american association of physicists in medicine (AAPM) phantom was used for CT performance evaluation to evaluate the image quality. X-ray irradiation conditions for image acquisition was fixed at 120 kVp, 100 mAs and scanned 10 mm axis with ultra-high resolution. The improvement of anisotropic 2D diffusion filtering that we suggested firstly, increase the contrast of the image by using histogram stretching to the original image for 0.4%, and multiplying the individual pixels by 1.2 weight value, and applying the anisotropic diffusion filtering. As a result, we could distinguished five holes until 0.75 mm in the original image but, five holes until 0.40 mm in the image with improved anisotropic diffusion filter. The noise of the original image was 46.0, the noise of the image with improved anisotropic 2D diffusion filter was decreased to 33.5(27.2%). In conclusion improved anisotropic 2D diffusion filter that we proposed could remove the noise of the CT image and improve the spatial resolution.