• Title/Summary/Keyword: Fixation time

검색결과 513건 처리시간 0.03초

레이온 직물의 Wet-Fixation에 의한 DP가공에 관한 연구(II) -처리온도 및 시간의 영향- (A study on the Durable Press finish by Wet-Fixation Process for Rayon Fabrics (II) - Effect of Treatment Temperature and Time -)

  • 허윤숙;김은애
    • 한국의류학회지
    • /
    • 제13권4호
    • /
    • pp.357-369
    • /
    • 1989
  • The purpose of this study was to investigate the effects of treatment temperature and time on the, of easy-care and strength properties of the wet fixation processed rayon fabrics. Viscose rayon fabrics were treated with mixed resins of melamine formaldehyde (MF) and DMDHEU by one bath and two bath wet fixation processes. The MF/DMDHEU mixed resin concentrations were 50/100, 50/150, 100/100 and 100/150(g/1). Magnasium chloride was used as a catalyst. The wet fixation conditions were 24hrs at room temperature,20 mins at $75^{\circ}C$ and 5 mins at $105^{\circ}C$ Wet fixation processed fabrics did not show the difference in the resin add-one, DP ratings and wrinkle recovery angles by the different treatment temperatures and times. DP ratings were in the order of $105^{\circ}C>75^{\circ}C>room$ temp, in one bath and two bath wet fixation. Breaking and tearing strength of one bath processed fabrics showed in the order of $75^{\circ}C>room\;temp>105^{\circ}C$ The breaking strength of two bath processed fabrics showed in the order of $105^{\circ}C>75^{\circ}C>room$ temp. Tearing strength showed in the order of $75^{\circ}c>105^{\circ}C>room$ temp. Abrasion resistances were in the order of $75^{\circ}C>105^{\circ}C>room$ temp. in one bath and two bath processes.

  • PDF

과학 교과서의 표를 해석하는 초등교사들의 안구 운동 추적 (Eye-Tracking on Inservice Elementary Teachers' Interpreting of Science Textbook Tables)

  • 최현동;신동훈
    • 한국초등과학교육학회지:초등과학교육
    • /
    • 제31권3호
    • /
    • pp.358-371
    • /
    • 2012
  • The main purpose of this study was to examine elementary teachers' visual attention that appears in science textbook tables. This paper proposed that teachers' cognitive effectiveness can be different by the presence or absence of the title of tables. The eye fixation data of participants are collected by the eye tracker apparatus. Participants in this study were 10 elementary school teachers and the table on the 2007 revised science textbooks were selected as experimental stimuli. Information about eye-fixations are recorded when subjects are given 4 tables by eye tracker. Eye-fixation time as well as the ratio and the number of fixation can be obtained by using the eye tracker but also we can acquire a significant conclusion through these outcomes. As the result of the experiment, it took less time to interpret in the presence of the title than in the absence of it. However, this result is only effective only for the interpretation of simple stimulus; the presence of title does not influence on fixation time in the analysis of complicated stimulation. This study showed that it is better to insult the title in the tables because it helps teachers to recognize contents of the tables effectively.

새로운 수용성(水溶性) 방부방충제(防腐防蟲劑)의 재중(材中) 정착성(定着性)에 관한 계면전기화학적(界面電氣化學的) 특성(特性) (Surface Electrochemical Study on the Fixation Properties of New Water-borne Preservatives in Red Pine)

  • 김영숙
    • Journal of the Korean Wood Science and Technology
    • /
    • 제24권4호
    • /
    • pp.93-99
    • /
    • 1996
  • In order to investigate the extent of fixation of new water-borne preservatives in blocks of pinus densiflora sapwoods the streaming potential through the column with preservative treated wood was measured at various conditions. The rates of leachability of ingredients in the treated wood were estimated by the measurement of electric conductivity of the solution with the leached components. The solution was also analyzed by Atomic absorption spectrophotometer (AA). As a results, the experimental data indicated that the fixation of CCB, CCFZ and ACQ in wood were relatively unstable. The fixation rates of CCB, CCFZ were improved by increasing heat and drying time. The amounts of the leached ingredients were apparently higher in CCB and CCFZ than in CCA, while the rate of leaching of ACQ was not changed at various drying temperature.

  • PDF

족관절 내과 골절시 보조적 관절경적 정복 및 내고정술이 필요한가? (Is an Arthroscopically Assisted Reduction and Fixation Necessary in the Medial Malleolar Fracture of the Ankle?)

  • 신동민;주평
    • 대한관절경학회지
    • /
    • 제2권1호
    • /
    • pp.93-96
    • /
    • 1998
  • We treated 10 cases of the medial malleolar fracture of the ankle by open reduction and internal fixation from June 1997 to December 1997. After the rigid internal fixation, we measured the gap of the fracture site and the step off of the articular surface by special instrument under the ankle arthroscopy whether it was reduced anatomically or not. And we tried to know the necessity of the arthroscopically assisted reduction and fixation in the medial malleolar fracture of the ankle. Under the arthroscopic view, all 10 cases were anatomically reduced as less than 1 mm of gap of the fracture site and less than 1mm of step off of the articular surface after open reduction and internal fixation in the medial malleolar fractures. In conclusion, through the arthroscopic management, it has advantage in finding and treating the accompanying intraarticular lesion, but also has disadvantage in setting the arthroscope and prolonging the operation time.

  • PDF

반연속식과 직렬식 공정에서 Chlorella sp. HA-1의 $CO_2$ 고정화 특성

  • 이재영;권태순;양지원
    • 한국생물공학회:학술대회논문집
    • /
    • 한국생물공학회 2000년도 추계학술발표대회 및 bio-venture fair
    • /
    • pp.455-456
    • /
    • 2000
  • Characteristics of $CO_2$ fixation by Chlorella sp. HA-1 were studied in a semi-continuous mode in a series operation. A high $CO_2$ fixation rate for a long time was obtained, when the method of semi-continuous mode was employed, in which the controlling parameter was the dilution ratio. A constant $CO_2$ fixation rate was maintained even when the dilution ratio was increased with the increment of 0.1 at the initial value of 0.5. The method of series operation was used to improve the efficiency of $CO_2$ fixation. The total amount of $CO_2$ fixation was proportion to the number of reactor in series operation.

  • PDF

견봉쇄골탈구와 원위쇄골골절에서 소절개를 이용한 Wolter금속판 내고정술 (Minimal incision Wolter Plate Fixation on the Displaced Lateral End Fracture of the Clavicle and the Acromioclayicular Dislocation)

  • 고상훈
    • Clinics in Shoulder and Elbow
    • /
    • 제5권1호
    • /
    • pp.23-28
    • /
    • 2002
  • Purpose Displaced lateral end fracture of clavicle and acromioclavicular dislocation type Ⅲ∼Ⅵ may be required surgical treatment. Material and Methods : From May 1998 to March 2001, we operated with Welter plate with minimal incision by one surgeon. Immediately, pendulum and passive exercise was initiated after surgery. The shoulder function was evaluated using UCLA score. Average follow up was on 28(12∼45) months. Results : All 11 patients were regained satisfactory function. Average UCLA score was 31.9(29~35) at last follow up. Conclusion . The merit of Welter plate fixation with minimal incision is simple technique, reduced surgical time, smaller scar than large plate, strong fixation, early exercise, reduced implant failure. The disadvantage is expensive, skin irritatatation by long hook. But Welter plate fixation with minimal incision is a good method of internal fixation and excellent clinical result in surgical treatment of type H displaced lateral end fracture of the clavicle and type Ⅲ∼Ⅵ acromioclavicular dislocation.

Comparison between Intramedullary Nailing and Percutaneous K-Wire Fixation for Fractures in the Distal Third of the Metacarpal Bone

  • Moon, Sung Jun;Yang, Jae-Won;Roh, Si Young;Lee, Dong Chul;Kim, Jin Soo
    • Archives of Plastic Surgery
    • /
    • 제41권6호
    • /
    • pp.768-772
    • /
    • 2014
  • Background To compare clinical and radiographic outcomes between intramedullary nail fixation and percutaneous K-wire fixation for fractures in the distal third portion of the metacarpal bone. Methods A single-institutional retrospective review identified 41 consecutive cases of metacarpal fractures between September 2009 and August 2013. Each of the cases met the inclusion criteria for closed, extra-articular fractures of the distal third of the metacarpal bone. The patients were divided by the method of fixation (intramedullary nailing or K-wire). Outcomes were compared for mean and median total active motion of the digit, radiographic parameters, and period until return to work. Complications and symptoms were determined by a questionnaire. Results During the period under review, 41 patients met the inclusion criteria, and the fractures were managed with either intramedullary nailing (n=19) or percutaneous K-wire fixation (n=22). The mean and median total active range of motion and radiographic healing showed no statistically significant difference between the two groups. No union failures were observed in either group. The mean operation time was shorter by an average of 14 minutes for the percutaneous K-wire fixation group. However, the intramedullary nailing group returned to work earlier by an average of 2.3 weeks. Complications were reported only in the K-wire fixation group. Conclusions Intramedullary nailing fixation is advisable for fractures in the distal third of the metacarpal bone. It provides early recovery of the range of motion, an earlier return to work, and lower complication rates, despite potentially requiring a wire removal procedure at the patient's request.

무지 외반증 환자의 원위 갈매기형 절골술시 절골면 고정유무에 따른 치료결과 비교 (A Comparison of with and without in the Fixation of Distal Chevron Osteotomies for Hallux Valgus)

  • 유성호;김부환;송무호;안성준;서상혁
    • 대한족부족관절학회지
    • /
    • 제10권2호
    • /
    • pp.230-233
    • /
    • 2006
  • Purpose: The distal chevron osteotomy has gained popularity for the mild to moderate hallux valgus, but necessity of fixation is controversy. No fixation of distal chevron osteotomy cause instability, but fixation has problem which has pin site infection and irritability, extension of operation time, discomfort of rehabilitation. So, the author was going to analyse and compare with and without in the fixation of distal chevron osteotomy. Materials and Methods: Between 2004 and 2005, a total 18 patients (20 feet) following with and without in fixation of distal chevron osteotomies. The fixation group (A) was performed for the treatment of 10 patients (10 feet) and no fixation group (B) was done to 8 patients (10 feet). Results: On group A, the mean first MTP (metatarsophalangeal) angle corrected $17^{\circ}$ pre-operatively to average $29^{\circ}$ (range; $20-37^{\circ}$) and the mean first IM (intermetatarsal) angle corrected $10^{\circ}$ pre-operatively to average $15^{\circ}$ (range; $9-18^{\circ}$). On Group B, the mean first MTP angle corrected $16^{\circ}$ pre-operatively to average $29^{\circ}$ (range; $18-33^{\circ}$) and the mean first IM angle corrected $7^{\circ}$ pre-operatively to average $13^{\circ}$ (range; $9-16^{\circ}$) (P>0.05). Clinical results, based on AOFAS score showed an improvement in the overall results. Conclusions: Comparing the clinical and radiographic results of the distal chevron osteotomies no difference in with and without fixation of distal chevron osteotomies.

  • PDF

Anterior Lumbar Interbody Fusion with Pedicle Screw Fixation for Elderly Isthmic Spondylolisthesis

  • Lee, Dong-Yeob;Lee, Sang-Ho;Maeng, Dae-Hyeon;Jang, Jee-Soo
    • Journal of Korean Neurosurgical Society
    • /
    • 제40권3호
    • /
    • pp.175-179
    • /
    • 2006
  • Objective : The surgical outcome of anterior lumbar interbody fusion[ALlF] with pedicle screw fixation for elderly isthmic spondylolisthesis was analyzed. Methods : Consecutive nineteen elderly patients [aged 65 years or more] with isthmic spondylolisthesis [Grade I or II] who underwent single level ALIF with pedicle screw fixation in 2002 were analyzed. Using clinical chart and mailed questionnaires, preoperative and postoperative Visual Analogue Scale[VAS] of back and leg pain and postopertive Macnab criteria were evaluated. Results : The mean age at the time of operation was 68.4 years [range 65 to 78 years]. Twelve patients underwent ALIF with percutaneous pedicle screw fixation. Seven patients underwent ALIF followed by posterior decompression and pedicle screw fixation. The postoperative complication rate was 10.5% [wound dehiscence in 1 patient and incisional hernia in 1 patient]. There was no postoperative major morbidity or mortality. At a mean follow-up duration of 30.7 months [range 25 to 35 months], 93.3% [14/15] of the patients showed excellent or good outcomes in terms of Macnab criteria. The mean VAS scores of back pain and leg pain significantly decreased after surgery. Conclusion : ALIF with pedicle screw fixation yielded favorable results for elderly isthmic spondylolisthesis in selected cases.

Internal Fixation with a Locking T-Plate for Proximal Humeral Fractures in Patients Aged 65 Years and Older

  • Yum, Jae-Kwang;Seong, Min-Kyu;Hong, Chi-Woon
    • Clinics in Shoulder and Elbow
    • /
    • 제20권4호
    • /
    • pp.217-221
    • /
    • 2017
  • Background: The purpose of this study was to evaluate the clinical and radiographic outcomes of internal fixation with locking T-plates for osteoporotic fractures of the proximal humerus in patients aged 65 years and older. Methods: From January 2007 through to December 2015, we recruited 47 patients aged 65 years and older with osteoporotic fractures of the proximal humerus. All fractures had been treated using open reduction and internal fixation with a locking T-plate. We classified the fractures in accordance to the Neer classification system; At the final follow-up, the indicators of clinical outcome-the range of motion of the shoulder (flexion, internal rotation, and external rotation) and the presence of postoperative complications-and the indicators of radiographic outcome-the time-to-union and the neck-shaft angle of the proximal humerus-were evaluated. The Paavolainen method was used to grade the level of radiological outcome in the patients. Results: The mean flexion was $155.0^{\circ}$ (range, $90^{\circ}-180^{\circ}$), the mean internal rotation was T8 (range, T6-L2), and the mean external rotation was $66.8^{\circ}$ (range, $30^{\circ}-80^{\circ}$). Postoperative complications, such as plate impingement, screw loosening, and varus malunion were observed in five patient. We found that all patients achieved bone union, and the mean time-to-union was 13.5 weeks of the treatment. The mean neck-shaft angle was $131.4^{\circ}$ at the 6-month follow-up. According to the Paavolainen method, "good" and "fair" radiographic results each accounted for 38 and 9 of the total patients, respectively. Conclusions: We concluded that locking T-plate fixation leads to satisfactory clinical and radiological outcomes in elderly patients with proximal humeral fractures by providing a larger surface area of contact with the fracture and a more rigid fixation.