Determination of Parameters of Equivalent Circuit Taking No-Load Losses Into Account for Single-Phase Induction Motors (단상 유도전동기의 무부하손실을 고려한 등가회로 정수의 결정)

  • Jwa, Chong-Keun;Kim, Do-Jin
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.4
    • /
    • pp.358-363
    • /
    • 2010
  • This paper proposes a step-by-step method of determining the parameters of equivalent circuit which is considered the no load losses for the single phase induction motor which has the starting winding. This method is comprised of three steps, and the stator resistance which is measured by the method of voltage drop is treated as constant and the stator and the rotor leakage reactances are assumed to be the same in every step. The test results of no load and locked rotor test are used in the 1st and 2nd step, and the ratings of name plate of the motor are needed in the 3rd step. In the 1st step, the traditional equivalent circuit parameters are directly calculated by no load and locked rotor conditions. In the next step, five nonlinear simultaneous equations for five unknown parameters can be set up by no load and locked rotor equivalent circuits. These equations are solved by using the initial parameters obtained by the 1st step parameters. In the final step, three nonlinear simultaneous equations for rotor winding resistance, leakage reactance and no load losses component resistance can be set up by equivalent circuit under the rated operation. Three parameters are solved by using the 2nd step parameters. Thus, equivalent circuit parameters are gradually refined step by step. The validity of the proposed method is evaluated by comparing the computed values obtained by the equivalent circuit parameters with the experimental values of the load test.

Detection of Incipient Faults in Induction Motors using FIS, ANN and ANFIS Techniques

  • Ballal, Makarand S.;Suryawanshi, Hiralal M.;Mishra, Mahesh K.
    • Journal of Power Electronics
    • /
    • v.8 no.2
    • /
    • pp.181-191
    • /
    • 2008
  • The task performed by induction motors grows increasingly complex in modern industry and hence improvements are sought in the field of fault diagnosis. It is essential to diagnose faults at their very inception, as unscheduled machine down time can upset critical dead lines and cause heavy financial losses. Artificial intelligence (AI) techniques have proved their ability in detection of incipient faults in electrical machines. This paper presents an application of AI techniques for the detection of inter-turn insulation and bearing wear faults in single-phase induction motors. The single-phase induction motor is considered a proto type model to create inter-turn insulation and bearing wear faults. The experimental data for motor intake current, rotor speed, stator winding temperature, bearing temperature and noise of the motor under running condition was generated in the laboratory. The different types of fault detectors were developed based upon three different AI techniques. The input parameters for these detectors were varied from two to five sequentially. The comparisons were made and the best fault detector was determined.

Multilevel Inverter to Reduce Common Mode Voltage in AC Motor Drives Using SPWM Technique

  • Renge, Mohan M.;Suryawanshi, Hiralal M.
    • Journal of Power Electronics
    • /
    • v.11 no.1
    • /
    • pp.21-27
    • /
    • 2011
  • In this paper, an approach to reduce common-mode voltage (CMV) at the output of multilevel inverters using a phase opposition disposed (POD) sinusoidal pulse width modulation (SPWM) technique is proposed. The SPWM technique does not require computations therefore, this technique is easy to implement on-line in digital controllers. A good tradeoff between the quality of the output voltage and the magnitude of the CMV is achieved in this paper. This paper realizes the implementation of a POD-SPWM technique to reduce CMV using a five-level diode clamped inverter for a three phase induction motor. Experimental and simulation results demonstrate the feasibility of the proposed technique.

Sliding Mode Control Based DTC of Sensorless Parallel-Connected Two Five-Phase PMSM Drive System

  • Kamel, Tounsi;Abdelkader, Djahbar;Said, Barkat;Al-Hitmi, M.;Iqbal, Atif
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.3
    • /
    • pp.1185-1201
    • /
    • 2018
  • This paper presents a sensorless direct torque control (DTC) combined with sliding mode approach (SM) and space vector modulation (SVM) to achieve mainly a high performance and reduce torque and flux ripples of a parallel-connected two five-phase permanent magnet synchronous machine (PMSM) drive system. In order to increase the proposed drive robustness and decrease its complexity and cost, the rotor speeds, rotor positions, fluxes as well as torques are estimated by using a sliding mode observer (SMO) scheme. The effectiveness of the proposed sliding mode observer in conjunction with the sliding mode control based DTC is confirmed through the application of different load torques for wide speed range operation. Comparison between sliding mode control and proportional integral (PI) control based DTC of the proposed two-motor drive is provided. The obtained speeds, torques and fluxes responses follow their references; even in low and reverse speed operations, load torques changes, and machines parameters variations. Simulation results confirm also that, the ripples of the torques and fluxes are reduced more than 3.33% and 16.66 %, respectively, and the speed overshoots and speed drops are reduced about 99.85% and 92.24%, respectively.

An Improved Operating Characteristics of Surface Permanent Magnetic Synchronous Generator for 5-Phase 5kW (5상 5kW 표면부착형 영구자석 동기발전기 특성개선)

  • Jung, Hyung-Woo;Kim, Min-Huei;Song, Hyun-Jik;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.9
    • /
    • pp.53-61
    • /
    • 2013
  • This paper propose a improved operating characteristics of the 5-phase 5kW within developed the surface permanent mount synchronous generator (SPMSG) in order to make a study of a polyphase ac motors keeping hold of more advantages. The developed manufacturing motor was necessary to do improvement of voltage regulation, efficiency, operating characteristics, and so on at the rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established generator by a repeat tests. There are shown a amplitude and waveform of the generated electromotive force, FFT analysis of harmonics within output voltages, and reviewing a experiment results in load of resistive and 5-phase induction motor by variable generator output frequency.

Comparison of Usability and Prefrontal Cortex Activity of Cognitive-Motor Training Programs using Sensor-Based Interactive Systems

  • Jihye Jung;Seungwon Lee
    • Physical Therapy Rehabilitation Science
    • /
    • v.11 no.4
    • /
    • pp.571-578
    • /
    • 2022
  • Objective: Cognitive-motor trainings had a positive impact on cognitive function and dual-task trainings led to improvements of global cognitive function. The brain activity of the prefrontal cortex (PFC) is another indicator that can infer cognitive function. This study aims to confirm the usability of the interactive system cognitive-motor training program and the changes in the prefrontal cortex through training. Design: Cross-sectional study Methods: In this study, two cognitive tasks were randomly applied to 20 adults as cognitive-motor training using an interactive system, and the same task was performed using the original method. During all tasks, the brain activity of the prefrontal cortex was measured by the change in oxyhemoglobin (HbO) in real-time using Functional Near-Infrastructure. After performing the tasks, the usability of the developed interactive system was evaluated by a usability questionnaire which consists of five items, and each item consists of a 7-point Likert scale that responds from 1 point to 7 points. Results: The HbO levels were increased during cognitive task performance than at the resting phase. And evaluating the usefulness of the interactive system, a questionnaire result showed that it would be useful for cognitive-motor programs. Conclusions: The cognitive-motor training using the interactive system increased the activity of the prefrontal cortex, and the developed wearable sensor-based interactive system confirmed its usefulness.

Changes in the Gait Pattern of Hemiparetic Patients with Subacute Basal Ganglia Stroke: a Retrospective Study (아급성 기저핵 뇌졸중 후 편마비 환자의 보행양상의 변화 : 후향적 연구)

  • Hong, Hae-jin;Kim, Cheol-hyun;Sung, Kang-kyung;Lee, Sang-kwan
    • The Journal of Internal Korean Medicine
    • /
    • v.37 no.6
    • /
    • pp.990-997
    • /
    • 2016
  • Objectives: This study observed changes in gait pattern according to the motor grade of the paretic lower limb in patients with basal ganglia stroke who are in the subacute phase. Methods: We used the Manual Muscle Test (MMT) to evaluate the motor grade of the paretic lower limb of 21 patients with subacute basal ganglia stroke and then divided them into two groups based on the MMT results. Stroke patients with a motor grade above Gr. III were put in group I (15 people) and those with a grade less than Gr. III in group II (6 people). We also estimated spatiotemporal factors using treadmill gait analysis equipment. The values were gait velocity, step length, step time, double support phase, and cadence. The first measure was conducted during the early period of admission and the second was between four and five weeks after admission. Results: In Group I, the gait velocity and step length of both legs significantly increased. In Group II, the step length and step time of the paretic side and the gait velocity tended to decrease, but not significantly. The step length of the paretic side in Group II was significantly longer than that in Group I at the first measure. The step time of the paretic side in Group I was significantly shorter than that in Group II and gait velocity and cadence in Group I were significantly higher than in Group II at the second measure. Conclusions: The gait parameters of all stroke patients improved in terms of time. In addition, the changes in gait pattern were different depending on the motor grade of the paretic lower limb.

The Design, Manufacture and Characteristic Experiment of a Small-Scaled High-Tc Superconducting Synchronous Motor (소용량 고온초전도 동기모터의 제작 및 특성 실험에 관한 연구)

  • Soug, Myung-Kon;Yoon, Yong-Soo;Hong, Gye-Won;Jang, In-Bae;Ko, Tae-Kuk
    • Proceedings of the KIEE Conference
    • /
    • 1999.07a
    • /
    • pp.241-243
    • /
    • 1999
  • This paper describes a series of experiments investigating the operational characteristics of high-Tc superconducting synchronous motor of five to six hundred watts capacity. In this experiment, ac 220V stator phase voltage and DC 4A excitation current are used, and the synchronous speed runs at 1800rpm. Hall Sensors are installed on the pole face and at the side of the Ag/Bi-2223 high-Tc superconducting tape in order to analyze the effect of the time-varying magnetic field on the motor performance when the load changes its value. The experimental observations are compared with the theoretical predictions.

  • PDF

Effects of Action Observation Training Combied with Auditory Cueing on Gait Ability in Patients with Stroke: a Preliminary Pilot Study

  • Kim, Hyeong-Min;Son, Sung-Min;Ko, Yu-Min
    • The Journal of Korean Physical Therapy
    • /
    • v.34 no.3
    • /
    • pp.98-103
    • /
    • 2022
  • Purpose: New therapeutic approaches have emerged to improve gait ability in patients with brain damage, such as action observation learning (AOT), auditory cueing, motor imagery etc. We attempted to investigate the effects of AOT with auditory cueing (AOTAC) on gait function in patients with stroke. Methods: The eighteen stroke patients with a unilateral hemiparesis were randomly divided into three groups; the AOTAC, AOT, and control groups. The AOTAC group (n=8) received training via observing a video that showed normal gait with sound of footsteps as an auditory cue; the AOT group (n=6) receive action observation without auditory stimulation; the control group (n=5) observed the landscape video image. Intervention time of three groups was 30 minutes per day, five times a week, for four weeks. Gait parameters, such as cadence, velocity, stride length, stance phase, and swing phase were collected in all patients before and after each training session. Results: Significant differences were observed among the three groups with respect to the parameters, such as cadence, velocity, stride length, and stance/swing phase. Post-hoc analysis indicated that the AOTAC group had a greater significant change in all of parameters, compared with the AOT and control groups. Conclusion: Our findings suggest that AOTAC may be an effective therapeutic approach to improve gait symmetry and function in patients with stroke. We believe that this effect is attributable to the change of cortical excitability on motor related to cortical areas.

A Development of Surface Permanent Mount Synchronous Generator for 5 Phase 5KW (5상 5KW 표면부착형 영구자석 동기발전기(SPMSG) 개발)

  • Jung, Hyung-Woo;Kim, Min-Huei;Kim, Dong-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.11
    • /
    • pp.87-96
    • /
    • 2012
  • This paper propose a development of surface permanent mount synchronous generator(SPMSG) for 5-phase 5Kw in order to study a polyphase ac machinery that keep hold of advantages more than traditional three-phase squirrel-cage induction motor, such as reducing a amplitude of torque pulsation decreasing electric noises, and increasing the reliability. Design methods of the generator use a development tools with Maxwell 2D and Simplorer. There are designed drawing of manufactured frames of the SPMSG. A amplitude and waveform of the generated electromotive force, FFT analysis of harmonics within output voltages, and reviewing a experiment results are shown by variable output frequency. We are presenting a design and manufacture methods for the SPMSG.