• Title/Summary/Keyword: Five phase motor

Search Result 69, Processing Time 0.02 seconds

Performance Analysis of a Five-leg Inverter for the Train Propulsion System (철도차량 추진시스템을 위한 FLI(Five-leg Inverter)의 성능 분석)

  • Lim, Young-Seol;Shin, Duck-Ho;Lee, June-Seok;Lee, Kyo-Beum
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.1
    • /
    • pp.43-54
    • /
    • 2017
  • This paper analyzes the performance of two three-leg inverters and a five-leg inverter and proposes the optimal operation conditions in applying the five-leg inverter for the train propulsion system. The five-leg inverter offers a saving of two switches compared with the standard two three-leg inverters and it is possible to control two three-phase motors independently by using a control board. All of these features lead to a potential reduction in capital cost and miniaturization of system. In this paper, first, the analysis of the existing motor control method and PWM method for two-traction motor drive of urban railway is implemented. Next, the operation principle and performance of five-leg inverter is introduced. Through the analysis, when it applies the same motor control method and the same PWM method for three-leg inverter and five-leg inverter, the characteristic of motor's speed and torque is compared.

Torque Density Improvement of Five-Phase PMSM Drive for Electric Vehicles Applications

  • Zhao, Pinzhi;Yang, Guijie
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.401-407
    • /
    • 2011
  • In order to enhance torque density of five-phase permanent magnetic synchronous motor with third harmonic injection for electric vehicles (EVs) applications, optimum seeking method for injection ratio of third harmonic was proposed adopting theoretical derivation and finite element analysis method, under the constraint of same amplitude for current and air-gap flux. By five-dimension space vector decomposition, the mathematic model in two orthogonal space plane, $d_1-q_1$ and $d_3-q_3$, was deduced. And the corresponding dual-plane vector control method was accomplished to independently control fundamental and third harmonic currents in each vector plane. A five-phase PMSM prototype with quasi-trapezoidal flux pattern and its fivephase voltage source inverter were designed. Also, the dual-plane vector control was digitized in a single XC3S1200E FPGA. Simulation and experimental results prove that using the proposed optimum seeking method, the torque density of five-phase PMSM is enhanced by 20%, without any increase of power converter capacity, machine size and iron core saturation.

Operating Characteristics of Squirrel-Cage Induction Motor of 5-Phase 1.5kW (5상 1.5kW 농형 유도전동기의 운전특성)

  • Kim, Min-Huei;Jung, Hyung-Woo;Song, Hyun-Jig
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.5
    • /
    • pp.52-59
    • /
    • 2014
  • This paper presents an improved operating characteristics of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase AC machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. The developed manufacturing motor was necessary to do improvement of speed regulation, efficiency, operating characteristics, and so on at rated load. There are remake a redesigned and distributed stator winding connection without changing the frames of stator and rotor core in previous established the motor by a repeat tests. There are shown a experiments results of no-load test, locked rotor test, operating characteristics at variable load, FFT analysis of harmonics within output voltages and current waveform, decided motor parameters.

Development of Squirrel-Cage Induction Motor for 5-Phase 1.5kW (5상 1.5kW 농형 유도전동기 개발)

  • Kim, Min-Huei;Jung, Hyung-Woo;Song, Hyun-Jik
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.28 no.1
    • /
    • pp.57-68
    • /
    • 2014
  • This paper propose a development of squirrel-cage induction motor(IM) for 5-phase 1.5kW, 220V, 60Hz in order to study a polyphase ac machinery that keep hold of advantages more than traditional three-phase a IM, such as reducing a amplitude of torque pulsation, decreasing electric noises, and increasing the reliability. Designed methods of the motor use a development tools with Maxwell 2D and Simplorer program. There are designed drawing of manufactured frames of the IM. amplitude and waveform of the generated electromotive force, FFT analysis of harmonics within output voltages and current, and reviewing a experiment results are shown by variable output. We are presenting a design and manufacture methods for the 5-phase squirrel-cage IM.

Hybrid-Boost Modular Multilevel Converter-Based Medium-Voltage Multiphase Induction Motor Drive for Subsea Applications

  • Daoud, Mohamed;Elserougi, Ahmed;Massoud, Ahmed;Bojoi, Radu;Abdel-Khalik, Ayman;Ahmed, Shehab
    • Journal of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.714-726
    • /
    • 2019
  • This paper proposes a hybrid-boost Modular Multilevel Converter (MMC) for the Medium-Voltage (MV) Variable Speed Drives (VSDs) employed in subsea applications, such as oil and gas recovery. In the presented architecture, a hybrid-boost MMC with a reduced number of semiconductor devices driving a multiphase Induction Machine (IM) is investigated. The stepped output voltage generated by the MMC reduces or eliminates the filtering requirements. Moreover, the boosting capability of the proposed architecture eliminates the need for bulky low-frequency transformers at the converter output terminals. A detailed illustration of the hybrid-boost MMC operation, the expected limitations/constraints, and the voltage balancing technique are presented. A simulation model of the proposed MV hybrid-boost MMC-based five-phase IM drive has been built to investigate the system performance. Finally, a downscaled prototype has been constructed for experimental verification.

Characteristics Analysis of Induction Motor by Operation of Non-lineal Loads (비선형 부하의 운전시 유도전동기의 특성 해석)

  • Kim, Jong-Gyeum;Park, Young-Jeen;Lee, Eun-Woong
    • Proceedings of the KIEE Conference
    • /
    • 2006.10b
    • /
    • pp.147-153
    • /
    • 2006
  • Voltage unbalance will be generated by the load unbalance operation such as combination operation of single & three phase load and current unbalance will be more severe by the deteriorated voltage quality. Under the these unbalance conditions, all power electronic converters used in different types of electronic systems can increase harmonic disturbances by injecting harmonic currents directly into the feeder grid of three phase 4-wire. Harmonic current may cause torque to decrease. it may also overheat or become noisy and torque oscillation in the rotor can lead to mechanical resonance and vibration. This paper presents a scheme on the characteristics of induction motor under the combination of linear & non-linear loads at the three phase 4-wire power distribution system by the unbalance and harmonic components. It was able to confirm that the number of torque pulsation decreased and torque ripple values increased by the harmonics that reduction was difficult by five harmonics filters at additional driving time of single-phase non-linear load.

  • PDF

Optimal Design of Five-Phase Permanent Magnet Assisted Synchronous Reluctance Motor for High Speed Railroad Traction System (고속철도 추진용 5상 영구자석 저감형 동기전동기의 최적설계)

  • Baek, Jeihoon;Kim, Myung Yong;Yi, Kyung-Pyo
    • Journal of the Korean Society for Railway
    • /
    • v.20 no.5
    • /
    • pp.588-594
    • /
    • 2017
  • Permanent magnet assisted synchronous reluctance motors (PMa-SynRM) show higher efficiency and power density compared to conventional induction motors for high speed railroad traction systems. Furthermore, 5-phase PMa-SynRMs have lower torque ripple and higher power density than 3-phase systems. Therefore, the 5-phase PMa-SynRM is suitable for high-speed railway traction systems. In this study, 3kw 3-phase and 5-phase PMa-SynRM models were optimized using lumped parameter model and genetic algorithm, and their characteristics were compared. The optimized models are fine-tuned using finite element analysis. The final models of the 3-phase and 5-phase PMa-SynRMs are fabricated and tested to verify the analysis results.

A Parameters Estimation of Five-phase Induction Motor (5상 유도전동기의 파라미터 추정)

  • Kim, Nam-Hun;Baik, Won-Sik;Kim, Min-Huei;Jung, Hyung-Woo;Kim, Dong-Hee
    • Proceedings of the KIPE Conference
    • /
    • 2010.07a
    • /
    • pp.55-56
    • /
    • 2010
  • 다상 유도 전동기(Multi phase induction motor)의 고성능 제어를 수행하기 위해서는 정확한 파라미터 계산이 필수적이다. 특히 전동기의 벡터제어(FOC, Field oriented control)나 직접토크제어(DTC, Direct torque control)와 같은 고성능 제어 시스템의 경우, 슬립 계산이나 자속관측기 그리고 PI 제어기 게인 추정에서 전동기 상수들이 필수적으로 사용된다. 본 논문에서는 실험용으로 집중권(Concentrated winding) 구조를 가지는 2kW, 5상 유도전동기를 제작하였으며, 5상 유도전동기 파라미터 추정에 대한 방법을 제시하였다. 일반적으로 다상 유도전동기의 경우 1차 공간 고조파(1st space harmonic) 성분에 대한 파라미터만을 추정하여 제어에 사용하지만, 본 논문에서는 1차 공간 고조파 성분과 3차 공간 고조파(3rd space harmonic) 성분에 대한 파라미터 추정 방법을 제시한다. 결과적으로 제안된 파라미터 추정 방법의 타당성을 확인하기 위해서 설계값과 실험값을 비교하였다.

  • PDF

Seismic Qualification Test on Motor Control Center for Use in Nuclear Power Plants (원자력발전소용 Motor Control Center의 내진검증시험)

  • 김병현
    • Proceedings of the Earthquake Engineering Society of Korea Conference
    • /
    • 1997.04a
    • /
    • pp.217-224
    • /
    • 1997
  • The safety related equipments for use in nuclear power plants should be subjected to the seismic qualification in order to insure the safety of the nuclear power plant. This paper summarizes the seismic qualification test on the Low Voltage Motor Control Centers(MCC's) for use in Wolsong Nuclear Power Plants, Units 2, 3 and 4. The seismic qualification test was performed on the two prototype MCC's(a two-bay wide unit for Phase #1 Test and a five-bay wide unit for Phase #2 Test). The specimens were electrically powered and monitored during the test process. It was demonstrated that the specimens possessed sufficient structural and electrical integrity to withstand the required seismic conditions.

  • PDF

Characteristics Analysis for Reactor Starting Method of 3-Phase Induction Motor Considering Saturation (포화성분을 고려한 3상 유도전동기 리액터 기동 특성 분석)

  • Kim, Jong-Gyeum
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.26 no.8
    • /
    • pp.65-70
    • /
    • 2012
  • Induction motor is the most widely used to obtain the driving force in the industrial site. Induction motor generates a high current at startup. Most of starting currents are often more than five times of rated current. This high starting current can cause problems such as the voltage drop in the system. In order to solve these problems, if the motor capacity is large, generally we use reactor starting method rather than direct on line starting method. When a high startup current passes through reactor, reactor can serve as a nonlinear elements. In this study, we analyzed that the current, torque and power of the induction motor are different from the change of linear and nonlinear components of the reactor magnetic field.