• Title/Summary/Keyword: Fitting ideal

Search Result 27, Processing Time 0.022 seconds

Ideal Phase map Extraction Method and Filtering of Electronic Speckle Pattern Interferometry (ESPI 에서의 이상적인 위상도 추출과 필터링 방법)

  • 유원재;이주성;강영준;채희창
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2001.04a
    • /
    • pp.235-238
    • /
    • 2001
  • Deformation phase can be obtained by using Least-Square Fitting. In extraction of phase values, Least-Square Fitting is superior to usual method like as 2, 3, 4-Bucket Algorithm. That can extract almost noise-free phase and retain 2$\pi$discontinuities. But more fringe in phase map, 2$\pi$ discontinuities is destroyed when that is filtered and reconstruction of deformation is not reliable. So, we adapted Least-Square Fitting using an isotropic window in dense fringe. using Sine-Cosine filter give us perfect 2$\pi$discontinuities information. We showed the process and result of extraction of phase map and filtering in this paper.

  • PDF

Ideal Phase map Extraction Method and Filtering of Electronic Speckle Pattern Interferometry (전자 스페클 간섭법에서의 이상적인 위상도 추출과 필터링 방법)

  • 강영준;이주성;박낙규;권용기
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.19 no.12
    • /
    • pp.20-26
    • /
    • 2002
  • Deformation phase can be obtained by using Least-Square fitting. In extraction of phase values, Least-Square Fitting is superior to usual method such as 2, 3, 4-Bucket Algorithm. That can extract almost noise-free phase and retain 2 $\pi$ discontinuities. But more fringes in phase map, 2 $\pi$ discontinuities are destroyed when that are filtered and reconstruction of deformation is not reliable. So, we adapted Least-Square fitting using an isotropic window in dense fringe. Using Sine/cosine filter give us perfect 2 $\pi$ discontinuities information. We showed the process and result of extraction of phase map and filtering in this paper.

A performance improvement of neural network for predicting defect size of steam generator tube using early stopping (조기학습정지를 이용한 원전 SG세관 결함크기 예측 신경회로망의 성능 향상)

  • Jo, Nam-Hoon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.11
    • /
    • pp.2095-2101
    • /
    • 2008
  • In this paper, we consider a performance improvement of neural network for predicting defect size of steam generator tube using early stopping. Usually, neural network is trained until MSE becomes less than a prescribed error goal. The smaller the error goal, the greater the prediction performance for the trained data. However, as the error goal is decreased, an over fitting is likely to start during supervised training of a neural network, which usually deteriorates the generalization performance. We propose that, for the prediction of an axisymmetric defect size, early stopping can be used to avoid the over-fitting. Through various experiments on the axisymmetric defect samples, we found that the difference bet ween the prediction error of neural network based on early stopping and that of ideal neural network is reasonably small. This indicates that the error goal used for neural network training for the prediction of defect size can be efficiently selected by early stopping.

Shape Design of the Bristle for the Periodontally Involved Patients by Using 3D Scanner (3차원 스캐너를 이용한 치주질환 이환자용 칫솔모의 형상설계)

  • Kim, Hyun-Jun;Suh, Myung-Won;Bae, Jong-Hyun
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.24 no.1 s.190
    • /
    • pp.93-100
    • /
    • 2007
  • In this study, an investigation was made on bristles for the prosthetic and periodontally involved patients based on the previous studies. The purpose of this study was to investigate the ideal location and dimensions of bristles for the patients who were installed with fixed prostheses and severely involved periodontitis. 3D scanner was used to develop 3D visual models of bristles and teeth. These models were developed to be used for designing the ideal bristles for the prosthetic and periodontally involved patients. For the ideal design of bristle, interproximal area of dental arch and bristle must get into maximum and standard teeth may have to be chosen from many gypsum molds. During the design process the factors should be considered that influence the removal of plaque by bristle.

Closed-form optimum tuning formulas for passive Tuned Mass Dampers under benchmark excitations

  • Salvi, Jonathan;Rizzi, Egidio
    • Smart Structures and Systems
    • /
    • v.17 no.2
    • /
    • pp.231-256
    • /
    • 2016
  • This study concerns the derivation of optimum tuning formulas for a passive Tuned Mass Damper (TMD) device, for the case of benchmark ideal excitations acting on a single-degree-of-freedom (SDOF) damped primary structure. The free TMD parameters are tuned first through a non-linear gradient-based optimisation algorithm, for the case of harmonic or white noise excitations, acting either as force on the SDOF primary structure or as base acceleration. The achieved optimum TMD parameters are successively interpolated according to appropriate analytical fitting proposals, by non-linear least squares, in order to produce simple and effective TMD tuning formulas. In particular, two fitting models are presented. The main proposal is composed of a simple polynomial relationship, refined within the fitting process, and constitutes the optimum choice. A second model refers to proper modifications of literature formulas for the case of an undamped primary structure. The results in terms of final (interpolated) optimum TMD parameters and of device effectiveness in reducing the structural dynamic response are finally displayed and discussed in detail, showing the wide and ready-to-use validity of the proposed optimisation procedure and achieved tuning formulas. Several post-tuning trials have been carried out as well on SDOF and MDOF shear-type frame buildings, by confirming the effective benefit provided by the proposed optimum TMD.

A Study on Women's Underwear Structures by Ideal Beauty - Focused on the late period of 20th century - (이상미에 따른 여성 속옷 구성에 관한 연구(2) - 20세기 후기를 중심으로-)

  • 김지연;전혜정
    • Journal of the Korean Society of Costume
    • /
    • v.53 no.5
    • /
    • pp.79-95
    • /
    • 2003
  • The purpose of this study is firstly to survey the social and cultural background of 20th century and women´s status, and to identify what the ideal body is like and what the elements of outer garment and underwear are and the techniques to incarnate the ideal beauty. Various papers are referenced for theoretical study and the elements and techniques of underwear are analyzed based on photographical materials. This paper concludes as follows. In 1960´s, ideal beauty was small bust, long legs, which showed extremely slim Mini-skirt look. Thinly or no padded brassiere were worn for small bust, and pants-style short panty girdles were popular as they used to wear pants frequently. Lycra replaced all the closures, bones, seams and gave freedom with light weight. In 1970´s, a natural human body without sex specific was in vogue. Therefore, the non-structural knits without a pad or lining or the shirts dress were widespread for a Natural look and the naturally molded brassiere or girdles were worn as the underwears. In 1980´s, the women with powerful muscle appear which emphasized liveliness and healthfulness. The body conscious represented by wide shoulder, plump breast, accented waist, small hips, and long legs has been embodied. Outer garments emphasized women power and healthy beauty with Power suit and Form-fitting style, and underwears made the breast plump with padded brassiere and emphasized waist and hips with waspie. In 1990´s, ideal beauty was slim body with big bust and the outer garments emphasized body line of women with Hourglass silhouette. Push-up bra which emphasizes the valley of breast and supports the breast upward and the control tights for slim waist, flat abdomen, small hips, and long and slim legs have been useful as underwears. Multi-functional micro-fiber has been ideal for sculpting women body.

The Research of Fitting Status of R.G.P Lenses Inspected by Optometrists in In-Cheon and Kyung-Gi Region (인천·경기지역 안경사들을 대상으로 한 R.G.P 렌즈 착용 실태 조사)

  • Kim, In-Suk;Kim, Young-Pil;Kim, Jung-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.27-33
    • /
    • 2007
  • This research investigated the effects of spherical and aspherical R.G.P lenses which was performed by optometrists in In-Cheon and Kyung-Gi region. This research survey included various questions such as the fitting status, after-care method, preliminary test. Results of the survey revealed that the optometriests sold the asperical and spherical lenses with a ratio of 7:3, respectively, and most of them did not cheked Topography, Fluorescein test by slit lamp biomicroscope, Tear Break up time test, Schirmer test and so on. And, with fitted R.G.P lenses symptoms like light odd-feeling, congestion, eye-stimulus, dimness and dryness were frequently reported. The purposes of this study are to search for the ideal fitting check of R.G.P lens and remind the most important preliminary test for contact lens fitting.

  • PDF

Design of Bristle Shapes using 3-dimensional Teeth Data for the Periodontally Involved Patients

  • Kim, Hyun-Jun;Suh, Myung-Won;Bae, Jong-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.27 no.4
    • /
    • pp.180-188
    • /
    • 2006
  • Bristles for the prosthetic and periodontally involved patients are investigated based on previous studies. Specifically, the ideal location and dimensions of bristles for the patients who were installed with fixed prostheses and severely involved periodontitis were investigated. 3D (Three-Dimensional) scanner was used to develop 3D visual models of bristles and teeth. These models were used for designing the ideal bristles. In the design, the interproximal area of dental arch and bristle must be maximized and the standard teeth may have to be chosen from many gypsum molds. During the design process the factors that influence plaque removal by the bristle were considered.

Analysis of Tubular Structures in Medical Imaging

  • Kim, Jin-Woo
    • Journal of information and communication convergence engineering
    • /
    • v.7 no.4
    • /
    • pp.545-550
    • /
    • 2009
  • A method fully utilizing multiscale line filter responses is presented to estimate the point spread function(PSF) of a CT scanner and diameters of small tubular structures based on the PSF. The estimation problem is formulated as a least square fitting of a sequence of multiscale responses obtained at each medical axis point to the precomputed multiscale response curve for the ideal line model. The method was validated through phantom experiments and demonstrated through phantom experiments and demonstrated to accurately measure small-diameter structures which are significantly overestimated by conventional methods based on the full width half maximum(FWHM) and zero-crossing edge detection.

A Comparative Analysis between Several Crutch-Length-Estimation Techniques and Ideal Crutch Length (이상적인 목발 길이와 목발 길이 추정법들간의 비교)

  • Kim, Min-Jung;Park, Yun-Soo;Yi, Chung-Hwi;Kim, Hyun-Ae
    • Physical Therapy Korea
    • /
    • v.3 no.1
    • /
    • pp.24-31
    • /
    • 1996
  • The purpose of this study was to determine which of several crutch-fitting techniques best predicts ideal crutch length. Ideal crutch length is defined as the length of the crutch, including accessories, obtained during stance when the crutch tip is 6 inches (15.2 cm) lateral and 6 inches(15.2 cm) anterior to the fifth toe and the axillary pad is 2.5 inches(6.4 cm) below the axillary fold. Forty four volunteers were measured for crutches using each of the following methods:(1) 77% of actual height, (2) actual height minus 40.6 cm, (3) actual height minus 45.7 cm, (4) olecranon to opposite third finger tip, (5) olecranon to opposite fifth finger tip, (6) 77% of arm span, (7) arm span minus 40.6 cm, (8) anterior axillary fold to heel plus 5.1 cm, (9) anterior axillary fold to heel plus 10.2 cm, (10) ideal crutch length. Of the techniques studied, the two involving anterior axillary fold to heel were found to be good predictors: anterior axillary fold to heel plus 5.1 cm and anterior axillary fold to heel plus 10.2 cm. Finally, two additional length estimates were derived using linear regression analyses. These estimates provided the best overall predictors based on anterior axillary fold to heel and actual height.

  • PDF