• Title/Summary/Keyword: Fitting evaluation

Search Result 307, Processing Time 0.031 seconds

A Comparison of the Contact Areas between Cornea and RGP Lenses by Fitting Status (피팅 상태에 따른 RGP 렌즈와 각막과의 간극 비교)

  • Park, Eun Hye;Kim, So Ra;Park, Mijung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.255-264
    • /
    • 2012
  • Purpose: In this study, the effect of lens fitting status on the contact area between spherical/aspherical RGP lens and the cornea having different astigmatic degree and corneal type was investigated for guiding the proper selection of RGP lens. Methods: Spherical and aspherical RGP lenses were applied on ninety eyes $(25.12{\pm}3.52years)$ having with-the-rule astigmatism by different fitting status. Then, their central, mid-peripheral and peripheral areas of fluorescein pattern were calculated and compared for the quantitative evaluation of the contact area between spherical/aspherical RGP lens. Results: The central and peripheral areas with the alignment fitting was significant different based on lens design. However, the central area didn't show any significant difference by lens design and corneal type when fitted in steep or flat. When analyzed by the corneal shape, both lenses with alignment and flat fitting had significant difference in central and peripheral areas. However, the central, mid-peripheral and peripheral areas with steep fitting didn't show the difference by corneal types. When analyzed by the astigmatic degree, the central and peripheral areas with alignment fitting changed proportionally to the increase of corneal astigmatism regardless of corneal shape. With steep and flat fitting, however, the central, mid-peripheral and/or peripheral areas in round- and symmetric bowtie-typed corneas showed the conflicting result when compared to those of alignment fitting when analyzed by the astigmatic degree. Conclusions: In this study, it was confirmed that the contact areas of cornea and RGP lens fitted steep and flat status were largely affected by the corneal type and corneal astigmatism rather than RGP lens fitted in alignment status. Also, this result commonly occurred in both spherical and aspherical RGP lenses.

Comparison between Genetic Algorithm and Simplex Method in the Evaluation of Minimum Zone for Flatness (평면도의 최소 영역 평가에서 유전자 알고리듬과 심플렉스 방법의 비교)

  • Hyun, Chang-Hun;Shin, Snag-Choel
    • Journal of Industrial Technology
    • /
    • v.20 no.B
    • /
    • pp.27-34
    • /
    • 2000
  • The definition of flatness is given by ISO, ANSI, KS, etc. but those standards don't mention about the specific methods for the flatness. So various solution models that are based on the Minimum Zone Method have been proposed as an optimization problem for the minimax curve fitting. But it has been rare to compare some optimization algorithms to make a guideline for choosing better algorithms in this field. Hence this paper examined and compared Genetic Algorithm and Simplex Method to the evaluation of flatness. As a result, Genetic Algorithm gave the better or equal flatness than Simplex Method but it has the inefficiency caused from the large number of iteration. Therefore, in the future, another researches about alternative algorithms including Hybrid Genetic Algorithm should be achieved to improve the efficiency of Genetic Algorithm for the evaluation of flatness.

  • PDF

Precision Evaluation Method for the Positioning Error of Three-DOF Parallel Mechanism using Coordinate Measuring Machine (CMM) (CMM을 이용한 3자유도 병렬기구 위치 오차의 정밀 평가 기법)

  • 권기환;박재준;이일규;조남규;양현익
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.21 no.11
    • /
    • pp.99-109
    • /
    • 2004
  • This paper proposes precision evaluation method for the positioning error of three-DOF translational parallel mechanism. The proposed method uses conventional CMM as metrology equipment to measure the position of end-effector. In order to obtain accurate measurement data from CMM, the transform relationship between the coordinate system of the parallel mechanism and the CMM coordinate system must be identified. For this purpose, a new coordinate referencing (or coordinate system identification) technique is presented. By using this technique accurate coordinate transformation relationships are efficiently established. According to these coordinate transformation relationships, an equation to calculate error components at any arbitrary position of the end-effector is derived. In addition, mathematical fitting models to represent the position error components in the two-dimensional workspace of the parallel mechanism are also constructed based on response surface methodology. The proposed error evaluation method proves its effectiveness through the experimental results and its application to real three-DOF parallel mechanism.

Animal Model Versus Conventional Methods of Sire Evaluation in Sahiwal Cattle

  • Banik, S.;Gandhi, R.S.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.19 no.9
    • /
    • pp.1225-1228
    • /
    • 2006
  • A total of 1,367 first lactation records of daughters of 81 sires, having 5 or more progeny were used to evaluate sires by 3 different methods viz., least squares (LS), best linear unbiased prediction (BLUP) and derivative free restricted maximum likelihood (DFREML) method. The highest and lowest overall average breeding value of sires for first lactation 305 days or less milk yield was obtained by BLUP (1,520.72 kg) and LS method (1,502.22 kg), respectively. The accuracy, efficiency and stability of different sire evaluation methods were compared to judge their effectiveness. The error variance of DFREML method was lowest ($191,112kg^2$) and its coefficient of determination of fitting the model was highest (33.39%) revealing that this method of sire evaluation was most efficient and accurate as compared to other methods. However, the BLUP method was most stable amongst all the methods having coefficient of variation (%) very near to unadjusted data (18.72% versus 19.89%). The higher rank correlations (0.7979 to 0.9568) between different sire evaluation methods indicated that there was higher degree of similarity of ranking sires by different methods ranging from about 80 to 96 percent. However, the DFREML method seemed to be the most effective sire evaluation method as compared to other methods for the present set of data.

Quantitative Assessment of Obstructive Uropathy with Diuretic Renography in Children (소아 폐쇄성 요로질환에서 이뇨 신 신티그라피의 정량적 분석)

  • Kim, Jong-Ho;Lee, Dong-Soo;Kwark, Cheol-Eun;Lee, Kyung-Han;Choi, Chang-Woon;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon;Choi, Yong;Choi, Hwang
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.239-247
    • /
    • 1993
  • Differentiating the various causes of hydronephrosis from that of obstruction can be very difficult. The decision-making process for those instances of urinary tract dilatation that require surgical correction and those that do not is based in part on the findings of diuresis renography. The methodology for performing this test has differed among nuclear medicine practitioners and the surgical findings are occasionally discrepant from the diuretic renogram interpretation. Consequently we made an automatic computer software program that calculates the slope of the response curve. The quantitative indices, such as the injection and response t1/2 by linear-fitting and monoexponential-fitting, were compared with the visual assessment of the diuretic cinerenography and clinical outcome in 50 children (62 kidneys) with ureteropelvic junction obstruction. Pooled diuresis renogram data indicated that: (1) Visual evaluation of the diuretic cinerenography is a sensitive (87%, 54/62) tool to differentiate obstruction in suspected ureteropelvic junction obstruction. (2) The cut-off value (maximum washout t1/2 with non-obstruction) of injection and response t1/2 by linear-fitting were 40 min. (3) The sensitivity and specificity using injection and response t1/2 by linear-fitting for obstruction were 89%(23/26) and 100%(30/30), respectively. (4) Response t1/2 as well as injection t1/2 by monoexponential-fitting do not stratify children with possible ureteropelivic junction obstruction. In conclusion, quantitative assessment of diuretic renography as well as visual assessment of diuretic cinerenography correlate well with surgical and clinical outcome of suspected ureteropelvic junction obstruction.

  • PDF

A Graphical Method for Evaluation of Stages in Shrinkage Cracking Using S-shape Curve Model (S형 곡선 모델을 적용한 수축 균열 단계 평가)

  • Min, Tuk-Ki;Vo, Dai Nhat
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.9
    • /
    • pp.41-48
    • /
    • 2008
  • The aim of this study is to present a graphical method in order to evaluate stages in shrinkage cracking. Firstly, the distribution of crack openings is established by sorting the openings of individual cracks in the soil cracking system. Secondly, it is normalized in a range of 0 to 1 to obtain the normalized crack opening distribution. Thirdly, three S-shape curve models introduced by Brooks and Corey(1964), Fredlund and Xing(1994) and van Genuchten(1980) are chosen to fit the normalized crack opening distribution using a curve fitting method. The accuracy of fitting which is described through fitting parameters by the van Genuchten equation is much higher than that by the Brooks and Corey equation and slightly higher than that by the Fredlund and Xing equation; thus the van Genuchten model is used. Finally, the stages of shrinkage cracking are graphically evaluated by drawing three separate straight lines corresponding to three linear parts of the fitted normalized crack opening distribution. The proposed method is tested with different sample thicknesses. The measured data are fitted by the selected model with the fairly high regression coefficient and small root mean square error. The results show graphically that shrinkage cracking comprises three stages; namely, primary, secondary and residual stages. Subsequently, the ranges of evaluated crack opening for each of these stages are presented.

Automatic Identification of the Lumen Border in Intravascular Ultrasound Images (혈관 내 초음파 영상에서 내강 경계면 자동 분할)

  • Park, Jun-Oh;Ko, Byoung-Chul;Park, Hee-Jun;Nam, Jae-Yeal
    • The KIPS Transactions:PartB
    • /
    • v.19B no.3
    • /
    • pp.201-208
    • /
    • 2012
  • Accurately segmenting lumen border in intravascular ultrasound images (IVUS) is very important to study vascular wall architecture for diagnosis of the cardiovascular diseases. After each of IVUS image is transformed to a polar coordinated image, initial points are detected using wavelet transform. Then, lumen border is initialized as the set of important points using non parametric probability density function and smoothing function by removing outlier initial points occurred by noises and artifacts. Finally, polynomial curve fitting is applied to obtain real lumen border using filtered important points. The evaluation of proposed method was performed with related method and the proposed method produced accurate lumen contour detection when compared to another method in most types of IVUS images.

Quantitative Rehabilitation Extent Monitoring for Unilateral Lower Extremity Disabled Patients using Simulated Gait Pattern Analysis (재활환자 모의보행 패턴분석을 이용한 하지 편측 장애자의 정량적 재활상태 모니터링)

  • Moon, Dong-Jun;Kim, Ju-Young;Noh, Si-Cheol;Choi, Heung-Ho
    • Journal of Biomedical Engineering Research
    • /
    • v.35 no.6
    • /
    • pp.227-233
    • /
    • 2014
  • In this paper, to quantitatively evaluate the degree of rehabilitation for the disabled of unilateral lower extremity, we compared the EMG pattern of normal and simulated abnormal gait. The EMG signal was measured at a rate of 1 kHz on the quadriceps and biceps femoris, the pressure sensor was attached to the sole in order to distinguish the gait cycle. Integrated EMG (IEMG) was obtained by the gait cycle, and classified four patterns that were the normal gait pattern, amplitude decrease pattern, reversed pattern, and irregular pattern. For comparison of the patterns, a curve fitting was performed using the trigonometric functions. The result of curve fitting, the method using a variable A that corresponds to the amplitude of the regression curve was able to distinguish the reverse pattern and remaining pattern. The coefficient of determination ($R^2$) representing coincidence of the pattern of the regression curve and EMG was confirmed the biggest value at the normal gait. Therefore, the degree of normal gait can be confirmed using the coefficient of determination. This results show that it is possible to quantitatively confirm the degree of unilateral lower extremity disabled rehabilitation, and it will be contributed to the study of efficient rehabilitation methods by objective analysis.

Performance evaluation of Edge-based Method for classification of Gelatin Capsules (젤라틴 캡슐의 분류를 위한 에지 기반 방법 성능 평가)

  • Kwon, Ki-Hyeon;Choi, In-Soo
    • Journal of Digital Contents Society
    • /
    • v.18 no.1
    • /
    • pp.159-165
    • /
    • 2017
  • In order to solve problems in automatic quality inspection of tablet capsules, computation-efficient image processing technique, appropriate threshold setting, edge detection and segmentation methods are required. And since existing automatic system for quality inspection of tablet capsules is of very high cost, it needs to be reduced through the realization of low-price hardware system. This study suggests a technique that uses low-cost camera module to obtain image and inspects dents on tablet capsules and sorting them by applying TLS curve fitting technique and edge-based image segmentation. In order to assess the performance, the major classifications algorithm of PCA, ICA and SVM are used to evaluate training time, test time and accuracy for capsule image area and curve fitting edge data sets.