• Title/Summary/Keyword: First-Void Urine

Search Result 3, Processing Time 0.016 seconds

Development of objective indicators for quantitative analysis of sodium intake: the sodium to potassium ratio of second-void urine is correlated with 24-hour urinary sodium excretion

  • Kim, Jung Gon;Han, Sang-Woong;Yi, Joo Hark;Park, Hyeong Cheon;Han, Sang Youb
    • Nutrition Research and Practice
    • /
    • v.14 no.1
    • /
    • pp.25-31
    • /
    • 2020
  • BACKGROUND/OBJECTIVES: To date, sodium intake has been evaluated based on spot urine instead of 24-hour (hr) urine collection. Nevertheless, the optimal method for assessing daily sodium intake remains unclear. SUBJECTS/METHODS: Fifteen male (age 32.7 ± 6.5 years) participants were offered 3 meals with a total of 9-10 g salt over 24 hours, and 24-hr urine was collected from the second-void urine of the first day to the first-void urine of the second day. Twenty-four-hr urinary sodium (24UNa) was estimated using Tanaka's equation and the Korean formula, and spot urine Na, potassium (K), chloride (Cl), urea nitrogen (UN), creatinine (Cr), specific gravity (SG) and osmolality (Osm) were measured. The ratios of urinary Na to other parameters were calculated, and correlations with total measured 24UNa were identified. RESULTS: Average 24-hr urine volume was 1,403 ± 475 mL, and measured 24UNa was 143.9 ± 42.1 mEq (range, 87.1-239.4 mEq). Measured 24UNa was significantly correlated with urinary Na/UN (r = 0.560, P < 0.01), urinary Na/Osm (r = 0.510, P < 0.01), urinary Na/Cr (r = 0.392, P < 0.01), urinary Na/K (r = 0.290, P < 0.01), 24UNa estimated using Tanaka's equation (r = 0.452, P < 0.01) and the Korean formula (r = 0.414, P < 0.01), age (r = 0.548, P < 0.01), weight (r = 0.497, P < 0.01), and height (r = 0.393, P < 0.01) in all spot urine samples. Estimated 24UNa based on the second-void spot urine of the first day tended to be more closely correlated with measured 24UNa than were estimates from the other spot urine samples. The significant parameters correlated with the second-void urine of the first day were urinary Na/K (r = 0.647, P < 0.01), urinary Na/Cr (r = 0.558, P < 0.05), and estimated 24UNa using Tanaka's equation (r = 0.616, P < 0.05) and the Korean formula (r = 0.588, P < 0.05). CONCLUSIONS: Second-void urine is more reliable than first-void urine for estimating 24UNa. Urinary Na/K in the second-void urine on the first day is significantly correlated with 24UNa. Further studies are needed to establish the most reliable index and the optimal time of urine sampling for predicting 24UNa.

Comparative Evaluation of First Urine and Intermediate Urine Samples Collected using a Patented Urine Cup (특허 받은 소변컵을 이용하여 채집한 첫 소변과 중간소변 시료의 비교 평가)

  • Kim, SeungChul;Kim, HoSung;Kim, ChangUook;Pyo, SangShin
    • The Journal of the Korea Contents Association
    • /
    • v.22 no.6
    • /
    • pp.619-628
    • /
    • 2022
  • In general, as a method to confirm a urinary tract infection (UTI) in a medical institutions, urine culture including a urinalysis and an antimicrobial susceptibility test is performed. It is important to disinfect the area around the urethra and perineum before collecting urine samples, and it is important to collect it intermediate urine, not the first-void urine. We invented a patent urine cup (Patent No. 10-1732843) that can automatically and easily separate first-void urine and midstream urine and using this, the patent cup and the general cup were compared and evaluated using this. Nitrite (P<0.001), WBC (P=0.005), Bacterial colony count (P=0.001), colony positivity rate (P=0.004) in first-void urine (N=24), midstream urine (N=24) separated by patent cup to obtain a significantly higher value. This can be seen from the fact that the first-void urine and midstream urine separated using the patent cup were well separated. Also, the number of Bacterial colonies was statistically significantly higher in the midstream urine isolated using a patent cup (N=24) than in the midstream urine collected using a general cup (N=24) (average 7.9 vs. 4.0 on average, P= 0.002). Which means that the midstream urine separated using the patent cup is more sensitive to the UTI test than the midstream urine collected using a general cup.

Risk Factors of Primary Nocturnal Enuresis (일차성 야뇨증의 위험 요인)

  • Lee, Soo-Jin;Yang, Jung-An;Yoo, Eun-Sun;Seo, Jang-Wan;Lee, Seung-Joo
    • Childhood Kidney Diseases
    • /
    • v.4 no.1
    • /
    • pp.69-76
    • /
    • 2000
  • Purpose: The Pathogenesis of primary noctllrnal enuresis(PNE) is still controversial. Genetic factor and maturational delay of micturition reflex including arousal disorder, lack of nocturnal Arginine Vasopressin(AVP) release and functional bladder capacity have been suggested. We analyzed the risk factors of PNE. Methods: Fifty five children with PNE (20 enuretics diagnosed at school physical examination of the first grade students at Mok-Dong Elementary School and 35 enuretics (Age 6-7 year) diagnosed at Ewha Womans University Mok Dong Hospital) and 221 control students without PNE at school physical examination were included. Genetic, stress and developmental factors, arousability, water intake, urine volume, maximun voiding volume and daytime voiding dysfunction were compared. Results: 1) There was no significant difference between PNE and control group in sex ratio, birth order, percentage of working mothers, parental and child personality, age to start walking, school record and duration of sleep. 2) Family history in the PNE group was significantly higher than control group ($20.0\%\;vs\;2.7\%$)(P<0.05). 3) The difficulty in arousal in the PNE group was significantly more common than the control group ($70.9\%\;vs\;54.3\%$)(P<0.05). 4) Nocturnal water intake in the PNE group was significantly greater than the control group ($330{\pm}158.2\;mL\;vs\;235{\pm}129.5\;mL$). Nocturnal urine volume in the PNE group was significantly greater than the control group ( $390{\pm}61.5\;mL\;vs\;140{\pm}43.2\;mL$)(P<0.05). Daily water intake and daily urine volume did not significantly differ between the two groups. 5) Maximum urine volume per void in the PNE group was significantly lower than the control group ($107{\pm}35.9\;mL\;vs\;236{\pm}41.3\;mL$). Daytime voiding dysfunction in the PNE group was significantly more common than the control group ($80.0\%\;vs\;57.9\%$). The voiding frequency in the PNE group was significantly greater than the control group ($7.0{\pm}3.6\;vs\;5.4{\pm}1.6$)(P<0.05). Conclusion: In addition to genetic factors and maturational delay of micturition reflex (difficulty in arousal, nocturnal polyuria and decreased functional bladder capacity) nocturnal polydypsia was found to be the important risk factors fur PNE. So nocturnal fluid restriction should be encouraged as the first-line management of PNE.

  • PDF