• Title/Summary/Keyword: First molar

Search Result 1,022, Processing Time 0.03 seconds

In vitro study of the fracture resistance of monolithic lithium disilicate, monolithic zirconia, and lithium disilicate pressed on zirconia for three-unit fixed dental prostheses

  • Choi, Jae-Won;Kim, So-Yeun;Bae, Ji-Hyeon;Bae, Eun-Bin;Huh, Jung-Bo
    • The Journal of Advanced Prosthodontics
    • /
    • v.9 no.4
    • /
    • pp.244-251
    • /
    • 2017
  • PURPOSE. The purpose of this study was to determine fracture resistance and failure modes of three-unit fixed dental prostheses (FDPs) made of lithium disilicate pressed on zirconia (LZ), monolithic lithium disilicate (ML), and monolithic zirconia (MZ). MATERIALS AND METHODS. Co-Cr alloy three-unit metal FDPs model with maxillary first premolar and first molar abutments was fabricated. Three different FDPs groups, LZ, ML, and MZ, were prepared (n = 5 per group). The three-unit FDPs designs were identical for all specimens and cemented with resin cement on the prepared metal model. The region of pontic in FDPs was given 50,000 times of cyclic preloading at 2 Hz via dental chewing simulator and received a static load until fracture with universal testing machine fixed at $10^{\circ}$. The fracture resistance and mode of failure were recorded. Statistical analyses were performed using the Kruskal-Wallis test and Mann-Whitney U test with Bonferroni's correction (${\alpha}=0.05/3=0.017$). RESULTS. A significant difference in fracture resistance was found between LZ ($4943.87{\pm}1243.70N$) and ML ($2872.61{\pm}658.78N$) groups, as well as between ML and MZ ($4948.02{\pm}974.51N$) groups (P<.05), but no significant difference was found between LZ and MZ groups (P>.05). With regard to fracture pattern, there were three cases of veneer chipping and two interfacial fractures in LZ group, and complete fracture was observed in all the specimens of ML and MZ groups. CONCLUSION. Compared to monolithic lithium disilicate FDPs, monolithic zirconia FDPs and lithium disilicate glass ceramics pressed on zirconia-based FDPs showed superior fracture resistance while they manifested comparable fracture resistances.

Three-dimensional finite element analysis for determining the stress distribution after loading the bone surface with two-component mini-implants of varying length (다양한 길이의 two-component 미니 임플란트의 응력분산에 대한 3차원적 유한요소분석)

  • Choi, Bohm;Lee, Dong-Ok;Mo, Sung-Seo;Kim, Seong-Hun;Park, Ki-Ho;Chung, Kyu-Rhim;Nelson, Gerald;Han, Seong-Ho
    • The korean journal of orthodontics
    • /
    • v.41 no.6
    • /
    • pp.423-430
    • /
    • 2011
  • Objective: To evaluate the extent and aspect of stress to the cortical bone after application of a lateral force to a two-component orthodontic mini-implant (OMI, mini-implant) by using three-dimensional finite element analysis (FEA). Methods: The 3D-finite element models consisted of the maxilla, maxillary first molars, second premolars, and OMIs. The screw part of the OMI had a diameter of 1.8 mm and length of 8.5 mm and was placed between the roots of the upper second premolar and the first molar. The cortical bone thickness was set to 1 mm. The head part of the OMI was available in 3 sizes: 1 mm, 2 mm, and 3 mm. After a 2 N lateral force was applied to the center of the head part, the stress distribution and magnitude were analyzed using FEA. Results: When the head part of the OMI was friction fitted (tapped into place) into the inserted screw part, the stress was uniformly distributed over the surface where the head part was inserted. The extent of the minimum principal stress suggested that the length of the head part was proportionate with the amount of stress to the cortical bone; the stress varied between 10.84 and 15.33 MPa. Conclusions: These results suggest that the stress level at the cortical bone around the OMI does not have a detrimental influence on physiologic bone remodeling.

Effect of Cu Addition in Cu/Fe/Zr-Mixed Metal Oxide Mediums for Two-step Thermochemical Methane Reforming (2단계 열화학 메탄 개질을 위한 Cu/Fe/Zr-혼합 산화물 매체 내 Cu 첨가 효과)

  • Cha, Kwang-Seo;Kim, Hong-Soon;Lee, Dong-Hee;Jo, Won-Jun;Lee, Young-Seak;Kim, Young-Ho
    • Applied Chemistry for Engineering
    • /
    • v.18 no.6
    • /
    • pp.618-624
    • /
    • 2007
  • thermochemical methane reforming consisting of two steps on Cu/Fe/Zr mixed oxide media was carried out using a fixed bed infrared reactor. In the first step, the metal oxide was reduced with methane to produce CO, $H_2$ and the reduced metal oxide in the temperature of 1173 K. In the second step, the reduced metal oxide was re-oxidized with steam to produce $H_2$ and the metal oxide in the temperature of 973 K. The reaction characteristics on the added amounts of Cu in Cu/Fe/Zr mixed oxide media and the cyclic tests were evaluated. With the increase of the added amount of Cu in Cu/Fe/Zr mixed oxide media, the conversion of $CH_4$, the selectivity of $CO_2$ and the $H_2/CO$ molar ratio were increased, while the selectivity of CO was decreased in the first step. On the other hand, the evolved amount of $H_2$ was decreased with increasing the added amount of Cu in the second step. The $Cu_xFe_{3-x}O_4/ZrO_2$ medium added with Cu of x = 0.7 showed good regeneration properties in the 10th cyclic tests indicating that the medium had high durability. In addition, the gasification of the deposited carbon in the water splitting step was promoted with the addition of Cu in the media.

A COMPARISON OF RELEASE RATE AND CUMULATIVE RELEASE OF TEGDMA WITH OR WITHOUT THE APPLICATION OF BONDING RESIN (접착레진 적용 유무에 따른 TEGDMA의 방출속도 및 방출량 비교)

  • Shin, Hee-Jung;Jeon, Seong-Min
    • Restorative Dentistry and Endodontics
    • /
    • v.23 no.2
    • /
    • pp.701-709
    • /
    • 1998
  • Many dental composites are Bis-GMA based resin which diluted with the more fluid monomer triethylenglycol dimethacrylate(TEGDMA). TEGDMA is often present in exess so that some quantity remains unreacted following photo-initiated polymerization. TEGDMA is a component of some resin composites which contributes to their cytotoxicity. The presence of dentin between resin composite and pulp space reduce the cytotoxicity in vitro. The root system from extrcted human third molar was removed and then a circular occlusal cavity 4mm in diameter was prepared, leaving a remaining dentinal thickness to the roof of the pulpal chamber within the range 1.0-1.5mm. Dentine was treated with 37% phosphoric acid prior to Z 100 placement without using bonding resin(group 1). In group 2, SMP(Scotchbond Multi Purpose) primer, bonding resin prior to Z 100 placement were applied sequently. In group 3, moulds with internal dimensions 4mm diameter by 2mm depth were used to contain the composite alone with an equvalent mass on tooth model, and then they were immersed directly into water. The purpose of this study is to evaluate the release rate and quantity of TEGDMA with or without the application of bonding resin. Both release rate and total cumulative amount of TEGDMA for the three groups were determined using reversed-phase HPLC at times up to 10 days. The results were as follows: 1. All experimental groups showed the highest rate of release was in the first sample period(0-4.32 min) and the rate of release declined exponentially thereafter. 2. The maximum release rate and total cumulative account of TEGDMA in the tooth model of group 1 and group 2 with the use of SMP bonding resin were reduced however ther were no significant differences between these groups(P>0.05). 3. In the first sample period(0-4.32 min), the rate of release of TEGDMA from composite resin in group 3 immersed directly into water was significantly higher than that in group 1 and group 2 of tooth model(P<0.05). Conclusively, TEGDMA diffusion from Z 100 resin was not effectively prevented by the presence of dentin in spite of using the SMP bonding resin.

  • PDF

THREE DIMENSIONAL FINITE ELEMENT STRESS ANALYSIS OF IMPLANT PROSTHESIS ACCORDING TO THE DIFFERENT FIXTURE LOCATIONS AND ANGULATIONS (임플랜트 지지 보철물에서 고정체의 식립위치와 각도에 따른 삼차원 유한요소법적 응력분석에 관한 연구)

  • Park Won-Hee;Lee Young-Soo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.1
    • /
    • pp.61-77
    • /
    • 2005
  • Statement of problem. The implant prosthesis has been utilized in various clinical cases thanks to its increase in scientific effective application. The relevant implant therapy should have the high success rate in osseointegration, and the implant prosthesis should last for a long period of time without failure. Resorption of the peri-implant alveolar bone is the most frequent and serious problem in implant prosthesis. Excessive concentration of stress from the occlusal force and biopressure around the implant has been known to be the main cause of the bone destruction. Therefore, to decide the location and angulation of the implant is one of the major considering factors for the stress around the implant fixture to be dispersed in the limit of bio-capacity of load support for the successful and long-lasting clinical result. Yet, the detailed mechanism of this phenomenon is not well understood. To some extent, this is related to the paucity of basic science research. Purpose. The purpose of this study is to perform the stress analysis of the implant prosthesis in the partially edentulous mandible according to the different nature locations and angulations using three dimensional finite element method. Material and methods, Three 3.75mm standard implants were placed in the area of first and second bicuspids, and first molar in the mandible Thereafter, implant prostheses were fabricated using UCLA abutments. Five experimental groups were designed as follows : 1) straight placement of three implants, 2) 5$^{\circ}$ buccal and lingual angulation of straightly aligned three implants, 3) 10$^{\circ}$ buccal and lingual angulation of straightly aligned three implants. 4) lingual offset placement of three implants, and 5) buccal offset placement of three implants. Average occlusal force with a variation of perpendicular and 30$^{\circ}$ angulation was applied on the buccal cusp of each implant prosthesis, followed by the measurement of alteration and amount of stress on each configurational implant part and peri-implant bio-structures. The results of this study are extracted from the comparison between the distribution of Von mises stress and the maximum Von mises stress using three dimensional finite element stress analysis for each experimental group. Conclusion. The conclusions were as follows : 1. Providing angulations of the fixture did not help in stress dispersion in the restoration of partially edentulous mandible. 2. It is beneficial to place the fixture in a straight vertical direction, since bio-pressure in the peri-implant bone increases when the fixture is implanted in an angle. 3. It is important to select an appropriate prosthodontic material that prevents fractures, since the bio-pressure is concentrated on the prosthodontic structures when the fixture is implanted in an angle. 4. Offset placement of the fixtures is effective in stress dispersion in the restoration of partially edentulous mandible.

Changes in periodontium after extraction of a periodontally-involved tooth in rats

  • Kim, Dong-Ju;Cha, Jae-Kook;Yang, Cheryl;Cho, Ahran;Lee, Jung-Seok;Jung, Ui-Won;Kim, Chang-Sung;Lee, Seung-Jong;Choi, Seong-Ho
    • Journal of Periodontal and Implant Science
    • /
    • v.42 no.5
    • /
    • pp.158-165
    • /
    • 2012
  • Purpose: Recent interest has focused on intentional replantation to restore an original tooth. Some studies have shown successful results with intentional replantation for periodontally involved teeth. For long-term success of replantation, a healthy periodontal status of the recipient site is required so that delayed replantation is more suitable for periodontally involved teeth. To reveal the ideal timing for delayed replantation of periodontally involved teeth, the healing process of extraction sockets after extraction of periodontitis-induced teeth in rats was evaluated. Methods: Twenty-eight rats were randomly divided into two groups: a control group (n=8) and test group (n=20). In the test group, periodontitis was induced by a ligature around the cervix of the mandibular first molar of all of the rats. Two weeks later, the mandibular first molars were extracted in all of the animals. The animals were sacrificed on days 0, 3, 7, and 10 after extraction and histological and immunohistochemical analysis was performed. Results: In histological analysis of the test group, inflammatory cell infiltrate was found abundantly in the remaining periodontium 3 days after tooth extraction and decreased gradually at later time points. In immunohistochemical analysis of the test group, both interleukin-6 (IL-6) and, tumor necrosis factor-${\alpha}$ (TNF-${\alpha}$) were numerous in the furcation area at each postextraction day. IL-6 was stained more heavily between 3 and 7 days after extraction; at day 10 after extraction, little staining was observed. TNF-${\alpha}$ staining was more intense at 3 days after extraction and gradually weakened at later points in time. Conclusions: Within the limits of this study, it takes at least 10 days to resolve periodontal inflammation in rat extraction sockets.

A STUDY ON THE DENTAL MATURATION IN CHILDREN WITH SKELETAL ANTERIOR CROSSBITE (골격성 전치부 반대교합 아동의 치아성숙도에 관한 연구)

  • Shin, Jong-Hyun;Kwon, Min-Seok;Kim, Shin;Jeong, Tae-Sung
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.37 no.3
    • /
    • pp.359-366
    • /
    • 2010
  • It was easy to find that children of a skeletal anterior crossbite in the early mixed dentition period showed a stark difference in the dental maturity between their maxillary and mandibular teeth, if they have stronger physical characteristics. If the difference of dental age between maxillary and mandibular teeth which can be identified via panoramic radiographs may serve as an early sign of class III malocclusion, this is considered valuable as a tool of early detection diagnosis. We obtained lateral cephalometric radiographs, panoramic radiographs, working model and clinical images of patients of Hellman dental age IIA and IIC who visited the department of pediatric dentistry, Pusan National University Dental Hospital and examined them to select 50 patents for normal occlusion group and skeletal anterior crossbite group, respectively. Their panoramic radiographs were used for the Demirjian's method to figure out dental ages of maxillary and mandibular teeth of each group and the eruption rate of the first molars. Their differences are as follows: 1. In both groups, the dental ages from Demirjian's method were advanced than the chronological ages. No sexual dimorphism was detected for the chronological or dental age in either group (p>0.05). 2. The difference of dental age of maxillary and mandibular teeth between the normal occlusion group and crossbite group was 0.22 and 0.69 years, respectively, with a higher difference in crossbite group(p<0.05). 3. Compared to the normal occlusion group, the crossbite group showed a higher difference in the eruption rate between maxillary and mandibular first molar(p<0.05).

Effects of Temperature on Diacylglycerol Production by Enzymatic Soli-Phase Glycerolysis of Hydrogenated Beef Tallow (온도조절이 고상계에 경화우지로부터 디글리세리드의 효소적생산에 미치는 영향)

  • Kang, Sung-Tae;Yamane, Tsuneo
    • Korean Journal of Food Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.567-572
    • /
    • 1994
  • Diglyceride was prepared by reaction of hydrogenated beef tallow and glycerol (GL) in the presence of a Pseudomonas lipase. Both substrates were mixed at the ratio of GL/Triglyceride of 0.5 which is the stoichiometric molar ratio for the complete conversion of triglyceride (TG) to diglyceride (DG). DG can be obtained by solid phase-glycerolysis of hydrogenated beef tallow without use of organic solvents or emulsifiers by careful control of reaction temperature. Optimized reaction temperature condition was as follows: An initial incubation at$60^{\circ}C$ for 2h followed by the first temperature shift down to $55^{\circ}C$ for 4h, and then the second shift down to $50^{\circ}C$ for up to 3 days. There was a large decrease in the content of TG during the first $60^{\circ}C$ incubation for 2h. Even a prolonged incubation at $60^{\circ}C$ could not make a change of the composition of the reaction mixture at liquid state. By controlling the temperature lower than $60^{\circ}C$, reaction mixtures were solidified. The reaction temperature at $50^{\circ}C$ below the melting temperature of hydrogenaed beef tallow gave an 71% optimum yield of DG after 72h enzymatic glycerolysis and about 73% of total DG was 1,3-DG.

  • PDF

COMPARISON OF BITE FORCE WITH DENTAL PRESCALE AND UNILATERAL BITE FORCE RECORDER IN HEALTHY SUBJECTS (Dental Prescale과 편측 교합력 측정기를 이용한 정상성인의 교합력 비교)

  • Kwon Ho-Keun;Yoo Ja-Hea;Kwon Young-Sook;Kim Baek-Il
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.44 no.1
    • /
    • pp.103-111
    • /
    • 2006
  • Statement of problem: The previous unilateral bite force recorder has several limitations for taking long time for measuring and causing discomfort to subjects. Because of these reasons, it could not use widely for epidemiological researches. However, 'Dental Prescale System' which is new equipment for measuring bite force, is more convenient for measuring bite force than previous unilateral recorder. Purpose: The purpose of this study was to compare a new technique(Dental Prescale System) using pressure sensitive foils for recording of maximal jaw closing force with conventional measurement using unilateral bite force recorder Material and method: This studies included 22 healthy dental students in college of dentistry Yonsei university in Rep of Korea. Mean age was 23.9 years. All subjects had continuous dental arches and no significant malocclusion or signs from the teeth and craniomandibular system. The Dental Prescale System (Fuji Film, Tokyo, Japan) consists of a horseshoe-shaped pressure sensitive sheet (50H, R type) and a computerized scanning system.(FPD705) We also used unilateral bite force recorder(Denbotics Co. Seoul, Rep.Korea) for comparing with Dental Prescale. Results and conclusion: The total bite force recorded with Dental Prescale System (1423 N) was systematically higher than that recorded by unilateral bite force recorder. (256 N) However, the maximum bite force values measured in the two ways were significantly correlated (r=0.46, p<0.05). The Dental Prescale bite force calculated for first molar (208 N) was lower than that recorded by unilateral bite force recorder. (256 N) The two values were also very significantly correlated. (r=0.66. p<0.001) There were significantly different in bite force between two measurement methods. The reasons were first, unilateral bite force recorder measured only the bite force of a part of teeth, and Dental Prescale measured the total teeth force. Second, in measurement, a difference in muscle contraction appeared by an extent of mouth-opening. Third, unilateral bite force recorder has the reducing effect of the bite force by protective tape. Fourth, Dental Prescale has limitations during the computer scanning procedure. Therefore, Dental Prescale System is considered to be a very promising alternative to be conventional bite force recording methods.

Implants in conjunction with removable partial denture (임플란트를 이용한 국소의치 수복)

  • Kim, Seong-Kyun;Yoo, Soo-Yeon;Park, In-Phil;Lee, Joo-Hee
    • The Journal of the Korean dental association
    • /
    • v.49 no.2
    • /
    • pp.77-84
    • /
    • 2011
  • The benefits of implant supported overdenture are readily apparent for the fully edentulous patients and have been well documented, however, there is deficiency of the studies regarding the combination of implants with removable partial dentures for partially edentulous patients. The purpose of this article is to review the literature concerning implants with removable partial dentures and evaluate the evidence for this clinical approach. Through many clinical case reports and studies we have searched from a broad variety of journals, we present the six considerations needed to contemplate respecting implants with removable partial denture in partially edentulous patients. First, the connection between abutment tooth and removable partial denture has to be rigid and the link between implant and removable partial denture should be hinged. Second, a mesial rest acts better in the point of force distribution for distal extension removable partial denture and splinting between implants is also a favorable choice. Third, T bar has an advantage for implants which are used as abutments in distal extension removable partial denture. Forth, as we all known functional impression is better way to reproduce movement for distal extension removable partial denture. Fifth, indirect retainer and guiding plane on the proximal surfaces of terminal abutment teeth are important in preventing denture base lifting. Sixth, implants in conjunction with removable partial denture is superior in the esthetic and phonetic as well as cost-effective point of view. We also suggest that which place we should install implants for force distribution and which diameter and length of implants should be used. in this review article, we recommend to locate the implant near of the abutment tooth for esthetics or near of first molar position for good stress distribution. The diameter and length of implant also influence to stress distribution. When we compare to conservative partial denture, patients go for removable partial denture using implants due to convenience, better support and retention according to several studies. But it is true that we need to study more on this subject and collect long term follow up cases before we discuss on it. So it is enough to bring this subject into the surface of prosthetic treatment by this article.