• Title/Summary/Keyword: First molar

Search Result 1,022, Processing Time 0.028 seconds

A LONGITUDINAL ROENTGENO-CEPHALOMETRIC STUDY ON THE CEPHALO-FACIO-DENTAL RELATIONSHIPS OF NORMAL KOREAN CHILDREN AGED FROM 6 TO 11 YEARS BY SASSOUNI'S ANALYSIS (Sassouni분석법에 의한 한국 아동의 두개, 안모, 치아의 상호관계 변화에 관한 누년적 연구)

  • Ryu, Young Kyu
    • The korean journal of orthodontics
    • /
    • v.17 no.2
    • /
    • pp.165-183
    • /
    • 1987
  • The purpose of this study is to investigate the cephalo-facio-dental relationships in the craniofacial complex and their changes with age, and to use them for diagnostic and treatment purposes in the orthodontics The author studied on the changes of the cephalo-facio-dental relationships, using serial lateral cephalometric roentgenograms of 46 boys and 47 girls aged from 6 to 11 years of normal Korean children Following results were obtained 1 Means and Standard deviation of Korean children were obtained. 2 In the evaluation of the craniofacial vertical proportions, lower anterior face was larger than the upper, and upper posterior face was larger than the lower at all ages 3 The growth change was more prominent in the anterior craniofacial vertical proportion than in the posterior, and growth increment in the upper anterior facial height dimension was larger than m the lower anterior. 4 In the evaluation of the craniofacial horizontal proportion, ANS, Pog, Go and 6 were all situated posterior to their reference ares, and point B was always situated anterior to the arc passing by point A. 5. Anteroposterior growth change was the most prominent in the mandible, and there was no significant difference between the horizontal growth increment in the cranial base and that in the maxilla 6 Growth increment in the horizontal direction was larger in the mandibular apical base than in the maxillary apical base 7 The upper central incisor and the upper first molar were gradually anterior positioned against their reference ares with age increase 8 The length of mandibular corpus was larger than that of cranial base from the seven years old, and the difference was increased as the age increased 9 With age, there was slight difference in the angular relationships formed by craniofacial reference planes and axial inclinations of upper and lower permanent teeth.

  • PDF

Synthesis and Characterization of Sm2O3 Doped CeO2 Nanopowder by Reverse Micelle Processing (역마이셀을 이용한 Sm2O3 도핑 CeO2 나노분말의 합성 및 특성)

  • Kim, Jun-Seop;Bae, Dong-Sik
    • Korean Journal of Materials Research
    • /
    • v.22 no.4
    • /
    • pp.207-210
    • /
    • 2012
  • The preparation of $Sm_2O_3$ doped $CeO_2$ in Igepal CO-520/cyclohexane reverse micelle solutions has been studied. In the present work, we synthesized nanosized $Sm_2O_3$ doped $CeO_2$ powders by reverse micelle process using aqueous ammonia as the precipitant; hydroxide precursor was obtained from nitrate solutions dispersed in the nanosized aqueous domains of a micro emulsion consisting of cyclohexane as the oil phase, and poly (xoyethylene) nonylphenylether (Igepal CO-520) as the non-ionic surfactant. The synthesized and calcined powders were characterized by Thermogravimetry-differential thermal analysis (TGA-DTA), X-ray diffraction analysis (XRD), and Transmission electron microscopy (TEM). The crystallite size was found to increase with increase in water to surfactant (R) molar ratio. Average particle size and distribution of the synthesized $Sm_2O_3$ doped $CeO_2$ were below 10 nm and narrow, respectively. TG-DTA analysis shows that phase of $Sm_2O_3$ doped $CeO_2$ nanoparticles changed from monoclinic to tetragonal at approximately $560^{\circ}C$. The phase of the synthesized $Sm_2O_3$ doped $CeO_2$ with heating to $600^{\circ}C$ for 30 min was tetragonal $CeO_2$. This study revealed that the particle formation process in reverse micelles is based on a two step model. The rapid first step is the complete reduction of the metal to the zero valence state. The second step is growth, via reagent exchanges between micelles through the inter-micellar exchange.

Sex determination by radiographic localization of the inferior alveolar canal using cone-beam computed tomography in an Egyptian population

  • Mousa, Arwa;El Dessouky, Sahar;El Beshlawy, Dina
    • Imaging Science in Dentistry
    • /
    • v.50 no.2
    • /
    • pp.117-124
    • /
    • 2020
  • Purpose: The purpose of this study was to evaluate possible differences in the location of the inferior alveolar canal in male and female Egyptians. Materials and Methods: This cross-sectional retrospective study involved the evaluation of 210 CBCT scans of Egyptian individuals (18-70 years old). The inferior alveolar canal was localized by measuring 8 linear dimensions: 2 for the vertical localization of the mental foramen (superior and inferior to the mental foramen), 4 at the first molar bifurcation for the vertical and horizontal localization of the inferior alveolar canal (superior, inferior, buccal, and lingual to the inferior alveolar canal), and 2 for the horizontal localization of the mandibular foramen (anterior and posterior to the mandibular foramen). The measurements were statistically analyzed via comparative analysis, stepwise logistic regression, and receiver operating characteristic (ROC) curve analysis. Results: Six of the 8 measured distances differed to a statistically significant extent between the sexes. Regression analysis suggested a logistic function with a concordance index of 84%. The diagnostic accuracy capabilities of the linear measurements as sex predictors were calculated using ROC analysis, and the 6 best predictors for sex determination were selected and ranked from highest to lowest predictive power. Moreover, combining these 6 predictors increased the predictive power to 84%. Conclusion: The location of the inferior alveolar canal in the Egyptian population varies significantly by sex; accordingly, this anatomic landmark could be used as a reliable indicator of sexual dimorphism.

Comparison of accuracy of digital data obtained by intra-oral scanner and extra-oral scanner (구강 내 스캐너와 구강 외 스캐너를 사용하여 취득된 스캔 데이터 정확도 비교)

  • Lee, Jae-Jun;Jeong, Il-Do;Kim, Chong-Myung;Park, Jin-Young;Kim, Ji-Hwan;Kim, Woong-Chul
    • Journal of Technologic Dentistry
    • /
    • v.37 no.4
    • /
    • pp.191-197
    • /
    • 2015
  • Purpose: The purpose of this study was to compare the accuracy of the scan data acquired by the extra-oral and intra-oral scanner. Methods: The maxillary right first molar was made of polymethyl methacrylate(PMMA) specimen. This PMMA specimen was scanned with a engineering scanner and intra-oral scanner. Meanwhile, extra-oral scanner scanned stone die duplicated from PMMA master die. Trueness and precision of scan datas was measured by 3-dimensinal inspection. Independent t-test was conduct to analysis the significant difference(a=0.05). Results: In the trueness analysis, mean of discrepancies were 13.82um for intra oral scanner and 16.84 um for extra-oral scanner. In the precision analysis, mean of discrepancies were 11.72 for inta-oral scanner and 9.2 for extra-oral scanner. Both trueness and precision showed a statistically significant difference (Table 1, p<0.05). Conclusion: Intra-oral scanner can show higher trueness than extra-oral scanner, it has lower precision.

Accuracy and reproducibility of 3D digital tooth preparations made by gypsum materials of various colors

  • Tan, Fa-Bing;Wang, Chao;Dai, Hong-Wei;Fan, Yu-Bo;Song, Jin-Lin
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.8-17
    • /
    • 2018
  • PURPOSE. The study aimed to identify the accuracy and reproducibility of preparations made by gypsum materials of various colors using quantitative and semi-quantitative three-dimensional (3D) approach. MATERIALS AND METHODS. A titanium maxillary first molar preparation was created as reference dataset (REF). Silicone impressions were duplicated from REF and randomized into 6 groups (n=8). Gypsum preparations were formed and grouped according to the color of gypsum materials, and light-scanned to obtain prepared datasets (PRE). Then, in terms of accuracy, PRE were superimposed on REF using the best-fit-algorithm and PRE underwent intragroup pairwise best-fit alignment for assessing reproducibility. Root mean square deviation (RMSD) and degrees of similarity (DS) were computed and analyzed with SPSS 20.0 statistical software (${\alpha}=.05$). RESULTS. In terms of accuracy, PREs in 3D directions were increased in the 6 color groups (from 19.38 to $20.88{\mu}m$), of which the marginal and internal variations ranged $51.36-58.26{\mu}m$ and $18.33-20.04{\mu}m$, respectively. On the other hand, RMSD value and DS-scores did not show significant differences among groups. Regarding reproducibility, both RMSD and DS-scores showed statistically significant differences among groups, while RMSD values of the 6 color groups were less than $5{\mu}m$, of which blue color group was the smallest ($3.27{\pm}0.24{\mu}m$) and white color group was the largest ($4.24{\pm}0.36{\mu}m$). These results were consistent with the DS data. CONCLUSION. The 3D volume of the PREs was predisposed towards an increase during digitalization, which was unaffected by gypsum color. Furthermore, the reproducibility of digitalizing scanning differed negligibly among different gypsum colors, especially in comparison to clinically observed discrepancies.

Fracture resistance of implant- supported monolithic crowns cemented to zirconia hybrid-abutments: zirconia-based crowns vs. lithium disilicate crowns

  • Elshiyab, Shareen H;Nawafleh, Noor;Ochsner, Andreas;George, Roy
    • The Journal of Advanced Prosthodontics
    • /
    • v.10 no.1
    • /
    • pp.65-72
    • /
    • 2018
  • PURPOSE. The aim of this in vitro study was to investigate the fracture resistance under chewing simulation of implant-supported posterior restorations (crowns cemented to hybrid-abutments) made of different all-ceramic materials. MATERIALS AND METHODS. Monolithic zirconia (MZr) and monolithic lithium disilicate (MLD) crowns for mandibular first molar were fabricated using computer-aided design/computer-aided manufacturing technology and then cemented to zirconia hybrid-abutments (Ti-based). Each group was divided into two subgroups (n=10): (A) control group, crowns were subjected to single load to fracture; (B) test group, crowns underwent chewing simulation using multiple loads for 1.2 million cycles at 1.2 Hz with simultaneous thermocycling between $5^{\circ}C$ and $55^{\circ}C$. Data was statistically analyzed with one-way ANOVA and a Post-Hoc test. RESULTS. All tested crowns survived chewing simulation resulting in 100% survival rate. However, wear facets were observed on all the crowns at the occlusal contact point. Fracture load of monolithic lithium disilicate crowns was statistically significantly lower than that of monolithic zirconia crowns. Also, fracture load was significantly reduced in both of the all-ceramic materials after exposure to chewing simulation and thermocycling. Crowns of all test groups exhibited cohesive fracture within the monolithic crown structure only, and no abutment fractures or screw loosening were observed. CONCLUSION. When supported by implants, monolithic zirconia restorations cemented to hybrid abutments withstand masticatory forces. Also, fatigue loading accompanied by simultaneous thermocycling significantly reduces the strength of both of the all-ceramic materials. Moreover, further research is needed to define potentials, limits, and long-term serviceability of the materials and hybrid abutments.

Comparison of three-dimensional digital technique with two-dimensional replica method for measuring marginal and internal fit of full coverage restorations

  • Hasanzade, Mahya;Koulivand, Soudabeh;Moslemian, Naeime;Alikhasi, Marzieh
    • The Journal of Advanced Prosthodontics
    • /
    • v.12 no.3
    • /
    • pp.173-180
    • /
    • 2020
  • PURPOSE. This study compared digital (reference point matching) and replica methods for measuring marginal and internal fit of full coverage restorations. MATERIALS AND METHODS. A maxillary left first molar typodent was fixed on to an aluminum base and prepared to receive all-ceramic full coverage restoration. The model was scanned with an intraoral scanner (CEREC Omnicam, Sirona, York, PA, USA). Twelve crowns were fabricated from lithium disilicate blocks (IPS emax CAD, Ivoclar Vivadent) and then crystalized. Marginal and internal fit of each restoration was measured by two examiners using replica and a new digital three-dimensional technique. Reliability between the two methods and two examiners was assessed by correlation and Cronbach's Alpha coefficient (P<.05). A Bland-Altman assessment for agreement was used to compare the two methods. RESULTS. Bland-Altman assessment showed that the mean of difference for marginal, absolute marginal, and axial gap was respectively -1.04 ㎛, -41.9 ㎛, and -29.53 ㎛ with limit of agreement (LOA) between -37.26 to 35.18 ㎛ for marginal, -105.85 to 22.05 ㎛ for absolute marginal and -80.52 to 22.02 ㎛ for axial gap. Positive correlation for repeatability (P<.05) in determining marginal and internal gaps by the two examiners in both techniques was revealed. Reliability of both techniques in all sites of measurements was at least good (0.8 ≤ α < 0.9). CONCLUSION. Both measuring techniques appeared highly reliable for evaluating fit of fixed dental restorations, while reference point matching provided higher values in axial and absolute marginal gap assessment.

CEPHALOMETRIC CHARACTERISTICS OF OPEN-BITE CASES WITH DEGENERATIVE JOINT DISEASE(DJD) OF TMJ

  • Kim, Tae-Woo
    • The korean journal of orthodontics
    • /
    • v.25 no.6 s.53
    • /
    • pp.665-674
    • /
    • 1995
  • The purpose of this study is to investigate the cephalometric characteristics of the open-bite patients with DJD of TMJ. The DJD open-bite cases were compared with normal samples and Class II open-bite cases with normal TMJ respectively. Twenty three open-bite patients with bilateral DJD of TMJ($13.9\~35.3$ yens old, Group I) were selected from the Department of Orthodontics, SNUDH. Group ll consisted of thirteen Class II open-bite cases($13.2\~27.4$ years old) with no TMD signs/symtoms and good condylar shapes. Group III samples were the forty eight healthy dental students who have Class I molar relationships with no history of orthodontic treatment, good facial balance and no TMD symptoms($20.0\~26.8$ years old). First, sixty measurements in the lateral cephalometric radiographs and analysis of variance(P<0.05, Scheffe) were used to compare these three groups. The seven measurements showed significant difference(p<0.05) between Group I and Group II. After analysis of variance, six of them were used for the discriminant analysis(Wilks' stepwise analysis) and the discrminant function for Group I/Group II was obtained. The results and conclusions were as follows : In most of the measurments, Group I and Group II showed the same skeletal and dental characteristics. But seven of the sixty measurements(FH-PP angle, SNB, FH-ArGo angle, articulare angle, genial angle, upper gonial angle and Ar-Go length) were significantly different(p<0.05) between Group I and Group II. These differences may be explained by the fact that in DJD cases the mandible rotated backward due to the shortening of the ramus following the degenerative destruction of condylar head and its surrounding structures. The resulting discriminant function was : $D={-0.120X}_1+{0.066X}_2+{0.144X}_3-{0.058X}_4+2000,\;where\;X_1=ArGo\;length(mm),\;X_2=SArGo\;angle(degree),\;X_3=FH-PP\;angle(degree),\;X_4=Gonial\;angle(degree)$. Mean of the group centroids was -0.555 and percent of the 'grouped' cases correctly classified was $88.89\%$.

  • PDF

RESPONSE CHARACTERISTICS OF VENTRAL POSTEROMEDIAL THALAMIC NOCICEPTIVE NEURONS IN THE ANESTHETIZED RAT (마취된 흰 쥐 시상의 복후내측핵내 유해성 뉴론의 특성)

  • Lee, Hyung-Il;Park, Soo-Joung
    • Restorative Dentistry and Endodontics
    • /
    • v.27 no.6
    • /
    • pp.587-599
    • /
    • 2002
  • Extracellular single unit recordings were made from the ventral posteromedial thalamic (VPM) nociceptive neurons to determine mechanoreceptive field (RF) and response properties. A total of 44 VPM thalamic nociceptive neurons were isolated from rats anesthetized with urethane-chloralose. Based on responses to various mechanical stimuli including touch, pressure and pinch applied to the RF, 32 of 44 neurons were classified as nociceptive specific (NS) neuron. The other 12 neurons, classified as wide dynamic range (WDR), showed a graded response to increasingly intense stimuli, with a maximum discharge to noxious pinch. The VPM nociceptive neurons showed various spontaneous activity ranged from 0-6 Hz. They were located throughout the VPM, and had an contralateral RF including mainly intraoral (and perioral) regions. The RF size was relatively small, and very few neurons had a receptive field involving 3 trigeminal divisions. The NS neurons activated only by pressure and pinch stimuli had high mechanical thresholds compared to WDR neurons activated also by touch stimuli. The VPM nociceptive neurons were tested with suprathershold graded mechanical stimuli. Most of 21 NS and 8 WDR neurons showed a progressive increase in number of spikes as mechanical stimulus intensity was increased. In some neurons, the responses reached a peak before the highest intensity was given. Application of 5 mM $CoCl_2{\;}(10{\;}{\mu}\ell)$ solution to the trigeminal subnucleus caudalis did not produce any significant changes in the spontaneous activity, RF size, mechanical threshold, and response to suprathreshold mechanical stimuli of 9 VPM nociceptive neurons tested. 17 of 33 VPM nociceptive neurons responded to noxious heat as well as noxious mechanical stimuli applied to their RF. Application of the mustard oil, a small-fiber excitant and inflammatory irritant, to the right maxillary first molar tooth pulp induced an immediate but short-lasting neuronal discharges upto approximately 4 min in 16 of 42 VPM nociceptive neurons. These results suggest that VPM thalamic nucleus may contribute to the sensory discriminative aspect of orofacial nociception.

STRAIN ON THE LABIAL PLATES AROUND ABUTMENTS SUPPORTING REMOVABLE PARTIAL DENTURES WITH VARIOUS PROSTHETIC DESIGNS: AN IN VITRO STUDY

  • Kim, Seong-Kyun
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.3
    • /
    • pp.322-330
    • /
    • 2005
  • Statement of problem. In distal extension removable partial denture, the preservation of health of abutment teeth is very important, but abutment teeth are subjected to unfavorable stress. Purpose. The purpose of this study was to investigate the biomechanical effects of mandibular removable partial dentures with various prosthetic designs using strain gauge analysis. Material and methods. Artificial teeth of both canines were anchored bilaterally in a mandibular edentulous model made of resin. Bilateral distal extension removable partial dentures with splinted and unsplinted abutments were fabricated. Group 1 : Clasp-retained mandibular removable partial denture with unsplinted abuhnents Group 2 : Clasp-retained mandibular removable partial denture with splinted abutments by 6-unit bridge Group 3 : Bar-retained mandibular removable partial denture Strain gauges were bonded on the labial plate of the mandibular resin model, approximately 2 mm close to the abutments. Two vertical experimental loadings (100N and 200N) were applied subsequently via two miniature load cells that were placed at mandibular first molar regions. Strain measurements were performed and simultaneously monitored from a computer connected to data acquisition system. For within-group evaluations, t-test was used to compare the strain values and for between-group comparisons, a one-way analysis of variance (ANOVA) was used and Duncan test was used as post hoc comparisons. Results. Strain values increased as the applied load increased from 100N to 200N for all groups (p<.05). The strain values of group 1 and 2 were tensile under loadings. In contrast, strain values of group 3 were compressive in nature. Under 100N loading, group 1 showed higher strain values than group 3 in absolute quantity (p<.05). Under 200N loading, group 3 showed higher strain values than group 1 and 2 in absolute quantity (p<.05). Group 1 showed higher strain values than group 2 (p<.05). Conclusion. Splinting of two isolated abutments by bridge reduced the peri-abutment strain in comparison with unsplinted abutments. Strain of bar-retained removable partial denture increased much more as applied load increased, but was compressive in nature.