• 제목/요약/키워드: Firing Order

검색결과 296건 처리시간 0.03초

유기형광법을 이용한 피스톤 유막두께의 이차원적 측정 (Measurement of two dimensional oil film thickness in piston by induced fluorescence method)

  • 민병순;최재권
    • 한국윤활학회:학술대회논문집
    • /
    • 한국윤활학회 1998년도 제28회 추계학술대회
    • /
    • pp.166-174
    • /
    • 1998
  • The distribution of oil film thickness in piston were measured by induced fluorescence method. A Xe lamp was used as light source. Coumarine-6 was mixed with oil as the fluorescent dye. Fluorescent signal which is proportional to the oil film thickness was acquired by CCD camera and transmitted to the personal computer as video signal. In order to solve the problem of measurement system, irregular distribution and unstability of light intensity, as well as to know the relationship between the oil film thickness and output signal, three different calibration techniques were used. Motoring and firing tests were performed in a single cylinder research engine with transparent liner. By analyzing the oil film thickness converted from the photographed image, it was observed that each of three piston rings scrapes the oil both upward and downward and oil film thickness is not uniform horizontally at a given piston land. The amount of oil in each land was considerably affected by the engine load. It is thought that the blow-by gas blows the oil down to the crankcase.

  • PDF

IPI의 확률밀도함수에 의한 근신호의 저주파 특성 해석 (Low Frequency Characteristics Analysis of EMG Signal on the Probability Density Function of the IPI)

  • 류재춘;조원경;박종국;김성환
    • 대한전자공학회논문지
    • /
    • 제25권3호
    • /
    • pp.335-342
    • /
    • 1988
  • In this paper, we proposed a new algorithm for EMG low frequency analysis. Through the power spectrum analysis of Gaussian's, Gamma's and Erlang's PDF(probability density function) based on the proposed algorithm, the proper PDF of IPI (inter pulse interval) representing the firing rate of muscle was suggested. In order to verify the proposed algorithm EMG signals of masseter and biceps muscle were detected by surface electrode and its power spectrum analysis was performed. The experimental results are compared with the computer simulaiton. As a result, the masseter muscle's IPI was fitted by Gamma PDF, having a 10Hz fundamental frequency including n(1+\ulcornerfp high harmnic frequency on 10% MVC(maximum voluntary contaraction). And the biceps muscle's IPI was fitted by Gaussian PDF, also it have a 14Hz fundamental frequency.

  • PDF

바이오매스의 연소 성능과 회재 특성 (Biomass Combustion Performance and Ash Characteristics)

  • 문지홍;김광수;정재용;박민선;박은혜;윤정준;황정호;이은도
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2012년도 제44회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.227-229
    • /
    • 2012
  • Diversification of combustion fuel is the demands of the times and biomass is the most attractive option since it can contribute to the prevention of global warming at the same time. Due to the national renewable obligation, generally called Renewable Portfolio Standard (RPS), many power companies are considering direct combustion of biomass or co-firing with coal. In order to use biomass as a fuel, informations of its combustion characteristics and ash related problems should be investigated. In this study, combustion performance of biomass was assessed in a bubbling fluidized bed combustor, and ash characteristics of various biomass fuels were studied with standard test method.

  • PDF

정밀발파의 표준화 (Standardization of Cautious blasting)

  • 허진
    • 화약ㆍ발파
    • /
    • 제8권3호
    • /
    • pp.3-13
    • /
    • 1990
  • First ot of all, under given condition such as bit gage of 36mm Drill bit with right class of jack-leg-experimental test carried out from two face of Bench, firing of each hole brought 90 degree Angle face and them measured length of Burden and charged ammount of powder as following. $ca=\frac{A}{SW}$ A=Activated Area A=nd i=m S=Peripheral length of charged, room Ca=Rock Coeffiecency d: di=Hole diameter When constructed subway of Seoul in 1980 the blasting works increased complaint of ground vibration, in order to prevent the damage to structures. Some empirical equations were made as follows on condition with Jackleg Drill (Bit Gage 36mm) and within 30 meter distance between blasting site and structures. $V=K(D/W)^{-n}$ N=1.60 - 1.78 K= 48 - 138 Project is one of contineous works to above a determination of empirical equation on the cautious blasting vibration with Crawler Drill (70-75mm) in long distance. $V=41(D/\sqrt[3]{W})^{-1.41}$ $30m\le{D}\le{100m}$ $V=124(D/\sqrt[3]{W})^{-1.66}$ $100m\le{D}\le{285m}$.

  • PDF

운동부하가 움직임-호흡 결합에 미치는 영향 (Effect of the Exercise Load on the Locomotor-Respiratory Coupling)

  • 남궁영;박은영;박호준
    • 한국전문물리치료학회지
    • /
    • 제5권3호
    • /
    • pp.56-62
    • /
    • 1998
  • The nature of entrainment between the locomotor and the respiratory rhythm was investigated while normal human subjects were walked or running on a treadmill. The purpose of this study was to analyze the incidence and type of coordination between the locomotor and the respiratory rhythm during running at different work load. The experiments were carried out on 12 untrained volunteers exercising at 3 work loads (2 METs, 3 METs, 4 METs in randomized order). The gait cycle was measured by electromyography (EMG) signal of gastrocnemius firing and the respiratory cycle was measured by a thermometer. We found that the ratio between the locomotor and the respiratory rhythm existed and 2:1 ratio between the locomotor-respiratory coupling was dominant at 2 METs and 3 METs.

  • PDF

Efficiency Counter Electrode Discharge Cells of PDP - a macro-cell experiment

  • Kim, Young-Jin;Choi, Won-Youl;Kim, Jin-Seok;Kim, Yong-seog;Choi, Byung-Do
    • 한국정보디스플레이학회:학술대회논문집
    • /
    • 한국정보디스플레이학회 2005년도 International Meeting on Information Displayvol.I
    • /
    • pp.255-258
    • /
    • 2005
  • In this study, new types of counter electrode discharge cells for PDP were designed. The counter electrode discharge cells were designed to realize long-gap discharge mode, low firing voltage and moderate conductance for evacuation and sealing process of the panel. In order to test the concept of the design, macro discharge cells were prepared and the discharge characteristics were evaluated. The results indicate that discharge behavior may be modified significantly by changing the morphology of discharge cells.

  • PDF

고효율 PDP를 위한 진공 인라인 실장에서의 MgO 보호막 영향분석 (MgO Thin Film Characterization in a Vacuum In-line Sealing Process for High-efficiency PDP)

  • 권상직;장찬규
    • 한국전기전자재료학회논문지
    • /
    • 제18권11호
    • /
    • pp.1019-1023
    • /
    • 2005
  • We have examined the electrical and optical characteristics of the plasma display panel produced by vacuum in-line sealing technology. In the MgO layer deposited at room temperature, after sealing at the panel temperature of $430^{\circ}C$, the luminous efficiency decreased compared with that of the panel before sealing. Moreover, firing and sustain voltage of the sealed panel increased compared with that of the panel before sealing. This was resulted from that the MgO protective layer was cracked by the softening of the dielectric layer during the sealing process. In order to avoid the MgO crack during the vacuum in-line sealing, thermally stable MgO layer or lower temperature sealing is required.

3상 비대칭 정류회로의 PAM 방식을 이용한 고주파 저감법 (Reducing Harmonics of 3-Phase Asymmctic Recnher Current using a PAM mcthod)

  • 오훈;윤양웅;박현철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 1995년도 추계학술발표회논문집
    • /
    • pp.105-109
    • /
    • 1995
  • In this paper, we persents a new PAM method without the input transformer for reducing harmonics in input AC line currents of converter. This system can reduce the harmonics like conventional 12-pulse converter. the dual bridge circuits are controlled with the shifted firing angle and connected 2 tap interphase reactor. the input current using 2 tap changing on interphase reactor is controlled with the different two values in order to make the input current waveform 12 pulses. The chracteristics of this system were confirmed through the computer simulation and the experiments.

  • PDF

텅스텐 중합금 복합관통자 제조 (Manufacturing of Tungsten Heavy Alloy Composites for Kinetic Energy Penetrator)

  • 송흥섭;김은표;박경진;류주하
    • 한국분말재료학회지
    • /
    • 제11권5호
    • /
    • pp.369-375
    • /
    • 2004
  • A new concept of tungsten heavy alloy composite was suggested and manufactured in this study for the kinetic energy penetrator. The composite heavy alloy was composed of two parts, the center was molybdenum added heavy alloy compositions which were designed to promote the self-sharpening effect and outside was conventional heavy alloy in order to sustain the severe stress condition in the muzzle during the firing. The center part showed an intergranular and brittle mode at tungsten/tungsten interfaces by which self-sharpening effect could be activated. On the other hand, that of outside showed conventional ductile fracture mode under high strain rate condition. From the sub-scale penetration test, the depth of penetration in heavy alloy composites showed greater values than those of conventional tungsten heavy alloys. It is suggested that the heavy alloy composite could be considered as one of the future penetrator materials.

치과 도재용 합금과 도재간의 결합력에 관한 연구 (Study of the Bond Strength Between Dental Ceramic Alloys and Porcelain)

  • 윤일중
    • 대한치과보철학회지
    • /
    • 제19권1호
    • /
    • pp.29-37
    • /
    • 1981
  • The bond strengths with ceramco porcelain were compared between precious alloy S, and non-precious alloys V.U. and R. And the changes in bond strengths of non-precious alloys with ceramco porcelain, according to surface preparations by sand blasting, longitudinal grinding, transverse grinding, and high polishing, were studied. The test specimens were prepared by firing porcelain doughnuts on the surface prepared alloy rods, and investing in dental stone. The specimens were subjected to shear loading forces. The conclusions drawn from the investigation are as follows: 1. The bond strengths with ceramco porcelain were higher in the non-precious alloys U and R, than in the precious alloy S. 2. The bond strengths were in descending order for R alloy, U alloy, V alloy, and S alloy. 3. The bond strengths were highest when the R alloy and U alloy were surface prepared by sand blasting. 4. All bond strength values were lowest when the alloy surfaces were prepared by high polishing.

  • PDF