• 제목/요약/키워드: Fire-retardant performance

검색결과 88건 처리시간 0.024초

샌드위치패널구조 기축건축물의 플래시오버 지연 공법 연구 (A Study on the Flash Over Delay Method for a Previously Constructed Building with Sandwich Panel Structure)

  • 김도현;조남욱
    • 대한건축학회논문집:구조계
    • /
    • 제33권12호
    • /
    • pp.71-80
    • /
    • 2017
  • The purpose of this study is to applied reinforcement method at the joint part of the sandwich panel. Becasue the joint part of the sandwich panel has a disadvantage that flame spreads fast inside steel plates in the event of fire, leading to a big fire rapidly. In this study, the combustion performance was measured through KS F ISO 13784-1 "Reaction-to-fire tests for sandwich panel building systems" according to the application of reinforcement method to prevent flame from being brought into the internal joint of the sandwich panel. For the reinforcement inside the panel, the tape produced using expanded graphite-based heat-expandable glass fiber was attached. As a result, it was confirmed that the prevention of flame from being brought into the internal joint could delay the flash over time and the collapse of the test specimen.

난연특성을 가지는 EVA/Intumescent/나노클레이 복합재료 제조 및 교호집성재(Cross Laminated Timber) 적용 기술 (Preparation of EVA/Intumescent/Nano-Clay Composite with Flame Retardant Properties and Cross Laminated Timber (CLT) Application Technology)

  • 최요석;박지원;이정훈;신재호;장성욱;김현중
    • Journal of the Korean Wood Science and Technology
    • /
    • 제46권1호
    • /
    • pp.73-84
    • /
    • 2018
  • 최근 들어 늘어나고 있는 도시형 화재 사고와 건축 외장재에 따른 화재 피해 사례의 증가에 따라 난연처리기술의 중요성이 부각되고 있다. 특히, 목재를 기반으로 한 건축재료의 활용에 있어서 난연처리기술은 더욱 중요하게 평가되고 있다. Intumescent 시스템은 비할로겐계 난연처리기술의 하나로, 발포와 탄화층 형성을 통하여 난연성을 구현하는 시스템이다. 본 연구에서는 Intumescent 시스템을 적용하기 위해 Ethylene vinyl acetate (EVA)를 매트릭스로 채용하여 복합재료를 제조하였다. Intumescent 시스템의 난연특성을 강화하기 위해 나노클레이를 함께 적용하였다. Intumescent 시스템과 나노클레이 기술을 함께 적용한 복합재료를 시트상의 시험편으로 가공한 후, 이를 활용하여 표면의 난연특성이 강화된 새로운 구조의 교호집성재를 제작하였다. Intumescent 시스템을 적용한 복합재료의 연소특성 평가에서 최대 열방출량이 효과적으로 감소되는 것을 확인할 수 있었다. 표면에 부착된 구조에 따라 CLT는 두 단계에 걸친 연소 현상이 발생했다. 또한, 심부 연소 과정에서 최대 열방출률이 크게 감소하는 경향을 확인할 수 있었다. 이러한 특성은 목재의 연소과정에 있어 연소 확산지연효과가 있을 것으로 판단된다. 표면단판에 대한 난연처리기술 및 복합재료 적용 최적화 기술을 통해 보다 화재특성이 개선된 CLT 구조체 개발이 가능할 것으로 기대된다.

플라이애시와 폐유리분말을 사용한 외단열용 마감모르타르의 고온 특성 (High Temperature Properties in Finishing Mortars of Exterior Insulation Finishing System Using Fly Ash and Waste Glass Powder)

  • 송훈;신현욱
    • 자원리싸이클링
    • /
    • 제28권6호
    • /
    • pp.64-72
    • /
    • 2019
  • 플라이애시는 발전소의 탄종 및 품질에 따라 화학조성이 다르고 품질 변화가 크며 탄소함량과 입경에 따라 분류하며, 폐유리분말은 파유리를 분쇄하여 제조하고 분쇄정도에 따라 분류한다. 건축물의 외단열 공법은 경제적이면서 단열성능이 우수한 폴리스티렌 폼 단열재를 활용한 공법이 일반적이다. 하지만 유기계 단열재는 단열성능이 우수하나 화재에 취약하고 다수의 문제점이 지적되었다. 본 연구에서는 플라이애시와 폐유리분말을 사용하여 고온에서 안정한 외단열용 마감모르타르를 제작하고 고온 강도 및 난연 특성을 검토하였다. 실험 결과, 플라이애시와 폐유리분말을 이용한 마감모르타르는 고온에서의 안전성이 높았다. 하지만 강도감소의 폭이 크므로 적절한 배합조건의 선정이 필요하다.

복합자재의 패널 간 화염확산방지에 따른 플래시오버 지연 효과에 대한 실험적 연구 (Experimental Study on the Flash Over Delay Effects according to the Prevention of Flame Spread between Composite Material Panels)

  • 김도현;조남욱
    • 한국화재소방학회논문지
    • /
    • 제31권2호
    • /
    • pp.1-8
    • /
    • 2017
  • 샌드위치패널은 건축물의 내 외벽 및 지붕구조에 사용되며 양면의 불연성재료와 단열용 심재로 구성된 복합자재이다. 뛰어난 단열성능과 경량 및 시공의 우수한 특성 대비 화재 시 패널간 결합부위를 통해 화염이 내부로 유입되어 심재가 쉽게 용융되며 급격한 화염확산으로 인명 및 재산피해를 발생시킨다. 현행 건축법은 건축물 마감재료에 대하여 소규모 시험편에 대한 화재시험방법으로 연소성능을 파악하며 규정한 성능기준에 합격한 제품을 사용하도록 한다. 외벽 마감재료의 경우 불연 준불연 성능확보 재료를 사용하거나 화재확산방지구조를 설치하도록 규정한다. 본 연구는 외벽 마감재료에 국한되어 적용하고 있는 화재확산방지 구조를 샌드위치패널 건축물에 적용하여 수평 수직 화재확산의 위험성의 차이를 확인하고자 하였다. 이에 샌드위치패널에 대하여 ISO 13784-1 시험방법을 통한 실물화재실험과 금속구조물을 이용하여 패널간 화염확산을 차단하는 시공을 통해 화염확산방지 적용 여부에 대한 연소거동과 그 효과를 측정하였다. 실험 결과 패널 조인트 부위의 화염확산방지구조 시공은 패널 내부의 화염확산을 지연하며 이에 따른 플래시오버 시간이 지연되어 복합자재 건축물의 화재안전확보에 중요한 요인으로 작용될 수 있음을 확인하였다.

잠재적 화재.폭발 위험 지역 작업용 녹전환형 중방식 코팅제의 특성에 관한 연구 (A Study on the Properties of the Heavy Duty Rust-Converting Agent used in the Potential Hazard Areas of Fire & Explosion)

  • 강영구
    • 한국안전학회지
    • /
    • 제13권3호
    • /
    • pp.102-111
    • /
    • 1998
  • This study was concerned with the development of a heavy duty rust-converting agent, the function of which is to form metal complex coatings, containing vinyl halide-acrylic terpolymer emulsion, defoamer, emulsifying agent, glass flakes, chelating agent such as gallotannic acid, gallic acid, and pyrogallic acid, and other additives. The resulted emulsion products(Sample No.1~No.5) were characterized through test either in the forms of emulsions, which include Viscosity, Penetration rate, Acidity and Film drying rate test, or in the forms of coated layer on rusty steel substrates by FT-IR, which include hardness, gloss, salt spray, adhesion and flame retardant test. The test results are as follows ; Penetration rate(0.1~0.4 mm/min), Solid content(70%), Acidity (pH 1.8~2.0), Specific gravity(1.30~1.35), Film drying rate(108min, RH 40% ; 150min, RH 80%), Gloss(83~92, incident angle $60^{\circ}$; 88~97, incident angle $85^{\circ}$), Pencil hardness(4H~5H), Adhesion (100/100), Salt spray test(>720Hr), LOI(%) value(38%), Vertical burning test(UL 94-v-l). According to the various performance of specimens show above, the evaluation of the availability of this heavy duty rust-converting agent can be concluded that all the samples(No.1~No.5) are capable of being used in the field of chemical plant and in the hazard areas of fire and explosion potential. It was observed that the properties of sample No.2, especially gloss and hardness, were much better than that of the other samples.

  • PDF

Study on Property Modification with Polymer Compositions in the Manufacture of Compounds for Cable Sheath

  • Li, Xiang Xu;Lee, Sang Bong;Cho, Ur Ryong
    • Elastomers and Composites
    • /
    • 제54권3호
    • /
    • pp.220-224
    • /
    • 2019
  • Herein, three polymer compounds were manufactured using three polymer combination methods, ethylene-vinyl acetate/ethylene-propylene-diene-copolymer (EPDM), ethylene-vinyl acetate (EVA)/polyethylene-A (PE-A; density: 0.870), and ethylene-vinyl acetate (EVA)/polyethylene-B (PE-B; density: 0.885), for making cable sheath for use in the shipping industry. In this study, EVA, EPDM, PE-A, and PE-B were used as matrix polymers, and EVA-grafted maleic anhydride was used as a coupling agent for compounding with various compounds such as a fire retardant, cross-linking agent, filler, and other additives, besides the plasticizer. ${\Delta}T$, Mooney viscosity, and tensile strength increased in order of EPDM < PE-A < PE-B, the probable reason is due to the different crosslinking effect. The three compounds showed similar results for fire resistance and aging resistance after compounding process, but they showed excellent cold resistance owing to the non-polarity of the polymers and sufficient plasticizer content.

노인의료복지시설 화재 시 와상노인의 피난안전성 제고를 위한 피난허용시간 연장과 소방기관으로의 통보시간 연구 (A Study on ASET Elongation & Notification Time to Fire Stations for the Escape Safety of Aged Bedridden Patients in Elderly Long-term Medical Care)

  • 박형주;이영재
    • 한국화재소방학회논문지
    • /
    • 제32권4호
    • /
    • pp.50-59
    • /
    • 2018
  • 고령화 추세에 따라 최근 급속히 증가하고 있는 노인복지시설에서 화재가 빈번하게 발생하고 있으나, 거주하고 있는 와상노인에 대한 피난안전성이 확보되어 있지 않아 대규모 인명피해를 초래하고 있다. 이런 시설에 거주하는 와상노인에 대한 피난안전성의 실효성을 제고하기 위한 방법의 일환으로 비화재구역의 피난허용시간을 최대한 연장시키면서 발코니 등의 일시피난안전구역에 차례로 피난시키고, 소방기관에 통보하는 화재속보설비를 통해 소방대의 출동에 의한 외부 조력피난유도방법이 최선의 대책인 것으로 판명되었다. 따라서 이와 같은 조력피난을 수행하는데 있어 반드시 적용해야할 요소기술을 방화 소방공학적으로 개발하여 4가지로 분류 제시하였다. 방화공학적 요소기술로는 구조 구획의 내화성능확보와 구획의 소규모화 규제 조항과 마감재의 난연 불연성능의 확보 규제 조항인 2가지를 제시하였다. 또한 소방공학적 요소기술로는 스프링클러에 의한 냉각효과 부과 규제 조항과 소방기관으로의 자동화재속보기능의 부여 규제 조항인 2가지를 제시하였다. 제시된 규제 조항에 대하여 일본과 국내의 법조문을 상세히 비교분석하여 국내에서 개정한 법조문상 미흡한 부분을 고찰하고, 국내의 노인복지시설의 피난안전성의 제고를 위해 시급하게 개선되어야 할 안전기준 개정(안)을 제시하였다.

건축용 바닥재의 외부복사열에 의한 화재위험성 비교 연구 (A Study on the Fire Risk Comparison of Building Flooring Materials by External Heat Flux)

  • 박영주;김영탁
    • 한국안전학회지
    • /
    • 제32권5호
    • /
    • pp.20-24
    • /
    • 2017
  • In this study, we have performed the Cone Calorimeter test in accordance with ISO 5660-1 to check the combustion characteristics of building flooring materials. The fire risk of these materials were evaluated by construction code, KFI criteria and standards of flame retardant performance. When samples exposed to external heat flux, all samples consumed a lot of Oxygen for a long time. So heat release from sample burning continued so long. And also all samples produced so much smoke. Even though a few samples were satisfied with only peak heat release rate criteria, all 8 samples were not satisfied with criteria of peak heat release rate and total heat released together. The results of 5 min total heat released were $15.9MJ/m^2{\sim}5.9MJ/m^2$. It menas the results are more than 2~6 times higher than the criteria. The results of 10 min total heat released were $30.1MJ/m^2{\sim}100.8MJ/m^2$. It means the results are more than 3~12 times higher than the criteria. 6 of 8 samples were not satisfied with Dm.corr.(corrected maximum smoke density) criteria. The building flooring materials which we used for this test ignited very fast and the burning continued so long. It means these samples are susceptible to fire.

물유리의 농도와 첨가제 종류에 따른 방염제의 성능 (Flame Retardancy of Plywood Treated with Various Water Glass Concentration and Additives)

  • PARK, Sohyun;HAN, Yeonjung;SON, Dong Won
    • Journal of the Korean Wood Science and Technology
    • /
    • 제49권1호
    • /
    • pp.44-56
    • /
    • 2021
  • 소방청의 방염성능기준에 제시된 45°멕켈 버어너법을 이용하여 물유리 농도와 첨가제 종류에 따른 합판의 탄화길이 및 면적 등의 방염성능을 측정하였다. 합판에 농도 20-50%의 물유리를 처리한 결과, 방염성능은 물유리의 농도와 비례하는 경향을 나타냈다. 그러나 30%를 넘는 고농도의 물유리로 처리된 합판의 표면에서 백화현상과 끈적임이 발생하여 농도 30%를 최적 조건으로 결정하였다. 농도 30%의 물유리에 서로 다른 비율의 첨가제를 추가하여 실험을 수행한 결과, 수산화칼륨 15% 조건과 수산화알루미늄 1-10%의 조건에서 방염성능 기준을 만족하였다. 반면에 황산마그네슘은 방염성능에 크게 영향을 미치지 않았다. 물유리와 첨가제에 따른 방염성능의 결과는 방염제를 활용한 불연재에 대한 기초자료로 활용될 것으로 기대된다.

단열재용 페놀폼의 물성과 열적특성 (Properties and Thermal Characteristics of Phenol Foam for Heat Insulating Materials)

  • 김동권;이수복
    • 공업화학
    • /
    • 제17권4호
    • /
    • pp.357-360
    • /
    • 2006
  • 본 연구에서는 단열재로서의 페놀수지(PF) 발포폼의 물성과 응용가능성을 검토하였다. 실험결과 페놀수지 발포폼의 밀도는 $0.030g/cm^3$를 나타내었고, 열전도율은 $0.026kcal/m.h.^{\circ}C$를 나타내었다. 또한 페놀수지 발포폼은 $500^{\circ}C$로 1 h 동안 열을 가했을 경우 약 71.7 wt%가 휘발되었다. 그리고 페놀수지 발포폼의 화학구조는 단열재로서의 중요 물성인 closed cell 구조형태를 갖는 것으로 분석되었다. 따라서 제조된 페놀수지 발포폼은 단열소재로서의 우수한 물성을 갖는 것으로 확인되었다.