• Title/Summary/Keyword: Fire-fighting systems

Search Result 86, Processing Time 0.02 seconds

Wireless Digital Packet Communication and Analog Image Communication Systems for Fire Fighting Robot (소방로봇 원격제어를 위한 무선패킷 디지털 데이터통신 및 아날로그 영상통신 기법)

  • Jung, Jik-Han;Kim, Byung-Wook;Park, Sang-Uk;Park, Dong-Jo;Park, Jung-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.121-127
    • /
    • 2007
  • Frequent occurrences of a fire cause tremendous loss of human lives and their property. Recently, in order to cope with such catastrophic accidents, researches on fire-fighting robots are carried out in developed countries. Under the dangerous situations, it is sometimes impossible for fire-fighting men to access the firing place because of explosive materials, smoke, high temperature and so on. In such an environment, fire-fighting robots can be useful to extinguish the fire. It is usually very dangerous place where fire-fighting robots operate. Hence, these robots should be controlled by remote users who are for away from the firing place exploiting remote communication systems. This paper considers the communication systems between fire-fighting robots and remote users. The communication systems consist of two parts; digital packet communication systems and analog image communication systems. Digital packet communication systems transfer data packets in order to control fire-fighting robots and to check the state of the fire-fighting robots. Remote users watch the video around the fire-fighting robots by exploiting the analog image communication systems. In the future, the more prosperous the commercial communication network systems will be, the more evolved the communication systems for fire-fighting robots are.

Problems and Reform Measures of Fire-Fighting Safety Management on the Skyscrapers (초고층 건축물 소방안전관리의 문제점과 개선방안)

  • Choi, Man-Chul;Lee, Dong-Hyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.32 no.4
    • /
    • pp.113-123
    • /
    • 2009
  • The number of high-rise buildings already constructed and/or being constructed is getting increased both domestically and internationally, for example, Lotte World 2 in Seoul and Taipei 101 in Taiwan, respectively. Maintenances of those skyscrapers, especially in fire-fighting safety, would be different from those of conventional buildings and are one of keen issues. In this study, the features of risks in aspects of fire-fighting safety for the buildings are investigated and the corresponding fire safety measures are proposed to prevent the disasters and to minimize the personal and property damages from it. The proposals include the specialization in self fire-fighting managements, the realization of self fire-fighting maintenance, the establishment of the integrated fire-fighting system, and the correction of inconsistencies in related laws on fire-fighting safety.

Improvement to the Applicable Scope of Automatic Fire Extinguisher to Reduce Fire Damage (화재피해 감소 위한 자동소화장치 적용범위 개선)

  • Baek, Chang Sun;Park, In Seon
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.1
    • /
    • pp.62-65
    • /
    • 2018
  • The rapid progress toward the 4th industrial society has led to possibilities of fire increase. It is pointed out that, though initial fire suppression is emphasized, the current legal systems do not sufficiently recognize the importance of initial fire suppression. In order to resolve this, problems of the current legal systems and regulations, as well as fire-fighting facilities to be equipped according to the size of specific fire-fighting objects, were diagnosed. Also, suggestions for improvement were provided through comparative analysis with relevant laws and technical regulations of Korea and other countries. According to fire safety standards such as NFPA, IMO, ISO, and Russian standards, automatic fire extinguishers are to be installed as per the adaptability criteria of fire extinguishers and automatic fire extinguishers. In Korea, the "Act on Fire Prevention and Installation, Maintenance, and Safety Control of Fire-fighting Systems" cover the types and scope of fire fighting facilities that include specific fire protection objects, such as electric room, power room, and substation room. This study has identified that, in case of a place with a floor area of less than $300m^2$, the installation requirement is not clearly specified. Therefore, in this study, fire extinguishing equipment and automatic fire extinguishing equipment to be added for each sub-use application are proved to have fire extinguishing performance of Class A, Class B, and Class C, respectively. In view of the fact that, in overseas standards, all space except containing such materials as Deep fire, metal fire and peroxide, can be installed with fire fighting equipment, a legal system for specifying the capacity units of fire fighting apparatus by application is, in this study, proposed.

Development of Eire-lighting and Rescue Robot for Outdoor Environment using Target Oriented Design Methodology (목표지향설계 개념을 이용한 실외화재진압 및 인명구조 로봇의 개발)

  • Kim, Moon-June;Maolin, Jin;Lee, Jin-Oh;Chang, Pyung-Hun;Kim, Jong-Hyun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.86-92
    • /
    • 2007
  • This paper presents the development of fire-fighting and rescue robot for Outdoor Environment. In the procedure of this development, we follow Target Oriented Design (TOD) which is recognized as the systematic methodology to design a system by specifying the target clearly. For some real fire fighting tasks (e.g. tasks in shopping street and a market), narrow road make it difficult for existing fire engine to access the firing place. On the other hand, for dangerous tasks (e.g. gasoline station and a storehouse) the explosive materials make it impossible for fire-fighters to access the firing place. Moreover, the smoke and the high-temperature caused by fire make fire fighting difficult. In this situation, the solution is to develop the fire-fighting and rescue robot. TOD is performed firstly by analyzing the environment properties of fro place and the demanded tasks and the fire-fighting and rescue robot is manufactured. For safety, the fire fighting robot should be controlled by remote operation to keep the operator away from the fire, and the control system is divided into three parts: the robot controllers, controller for remote operating device and wireless communication system. We have selected and developed appropriate hardware and software for each part of control system with considering TOD. As a result, the fire-fighting robot functions correctly and the performance and usefulness of our control architecture is validated by successfully performing some fire-fighting tasks.

Study of the Effective Management and Care System on in-Use Fire Fighteris Turnout Gear (소방복 유지관리시스템의 효율화 방안)

  • Son, Bong-Sae;Choi, Kye-Youn
    • Fire Science and Engineering
    • /
    • v.25 no.3
    • /
    • pp.72-77
    • /
    • 2011
  • This study aims to provide fundamental information required to establish an efficient maintenance and management system for fire fighting clothing which takes into account the domestic fire protection environment and situation. There aren't any detailed regulations and appropriate pre-inspection systems which would be required for proper maintenance of fire fighting clothing, as well as any test methods to determine the life spans of fire fighting clothing properly. Thus, this study tries to analyze the problems in use of fire fighting clothing and its maintenance situation and summarize overseas maintenance situation for fire fighting clothing. As a result, it is found that domestic fire fighting clothing is washed, repaired, and stored without any systematic management regulations. It is also found that the life spans of fire fighting clothing are determined, based on part of overseas management regulations on fire fighting clothing. Therefore, it is imperative to set up efficient management regulations and test methods for fire fighting clothing which would be required for efficient use of the fire fighting budgets and the life safety of fire fighters.

Test method and Requirements of Water-Based Fire-Fighting Systems for RO-RO Spaces and Special Category Spaces (Ro-Ro Space 화재진압성능 평가를 위한 시험절차 및 성능요건)

  • Kwark, Jihyun;Lee, Doo-Hyun;Kim, Young-Han
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2012.06a
    • /
    • pp.199-200
    • /
    • 2012
  • Test method and requirements of fixed water-based fire-fighting systems for Ro-Ro spaces and special category spaces were introduced for research engineer's reference.

  • PDF

Efficient Forest Fire Detection using Rule-Based Multi-color Space and Correlation Coefficient for Application in Unmanned Aerial Vehicles

  • Anh, Nguyen Duc;Van Thanh, Pham;Lap, Doan Tu;Khai, Nguyen Tuan;Van An, Tran;Tan, Tran Duc;An, Nguyen Huu;Dinh, Dang Nhu
    • KSII Transactions on Internet and Information Systems (TIIS)
    • /
    • v.16 no.2
    • /
    • pp.381-404
    • /
    • 2022
  • Forest fires inflict great losses of human lives and serious damages to ecological systems. Hence, numerous fire detection methods have been proposed, one of which is fire detection based on sensors. However, these methods reveal several limitations when applied in large spaces like forests such as high cost, high level of false alarm, limited battery capacity, and other problems. In this research, we propose a novel forest fire detection method based on image processing and correlation coefficient. Firstly, two fire detection conditions are applied in RGB color space to distinguish between fire pixels and the background. Secondly, the image is converted from RGB to YCbCr color space with two fire detection conditions being applied in this color space. Finally, the correlation coefficient is used to distinguish between fires and objects with fire-like colors. Our proposed algorithm is tested and evaluated on eleven fire and non-fire videos collected from the internet and achieves up to 95.87% and 97.89% of F-score and accuracy respectively in performance evaluation.

A Study on the Activation·Specification of 119 Rescue & Care in JeJu (제주도 119구조·구급대의 활성화 및 전문화 방안)

  • Koh, Jae-Moon;Kim, Tae-Min;Kim, Hyo-Sik;Lee, Young-A
    • The Korean Journal of Emergency Medical Services
    • /
    • v.6 no.1
    • /
    • pp.153-168
    • /
    • 2002
  • Since 1992, conventional fire fighting businesses have been converted into a metropolitan autonomous fire fighting system to be ready for a variety of disasters. However, the corresponding investment has been overlapped due to the non-integration of businesses to prevent any potential disasters, and a series of collaborative systems have been not functioning so well. In the meantime, our fire fighting sector has been trying to set up its own clean and faithful position by abolishing any inconvenient system or outsourcing private sectors, and expanded its work scope from conventional fire fighting even to rescue and emergency works. While focusing on handling disaster, the fire fighting sector has been widely trusted and reliable throughtout our nation. Moreover, our fire fighting sector has secured nation wide mobile organizations, technical personnel by field, special equipments and independent communication network. In addition, the fire fighting sector has knowledges, expertise and capabilities required for managing disasters, while in charge of almost every disaster management works including fire, explosion, collapse, disaster and flood. It becomes an organization for comprehensive disaster management under an absolute national trust, which is based on the system for prevention, preparation and countermeasure against a variety of disasters. Thus, our fire fighting sector must make many efforts and try to modernize conventional education and training. The ways to facilitate rescue and emergency works may include the nurture of technical fire fighting personnel along with modernized equipments, the reinforcement of rescue and emergency education, the facilitation of operating civil defense corps, the facilitation of operating volunteer fire fighting corps, the better arrangement of 119 briefing room for public healthcare in provincial offices, the sterilization of rescue instruments and equipments the better repair education for emergency rescue member, the establishment of regional emergency assistant system and the expansion of fire fighting personnel and equipments. In terms of reinforcing the functions and services of rescue 119 and emergency corps, we must review the following considerations: Building up security system along with operational expansion, building up a system for emergency medical treatment, building up a comprehensive information management system for rescue and emergency, constructing a provincial safety museum and so forth. For the ways to better the works of rescue 119 we can review the following considerations : Improving the education for fire fighting training corps under Jeju Provincial Fire and Disaster Management Department, providing rescue members with more opportunities for clinical practices, enhancing the morale of rescue members, installing a comprehensive briefing room for emergency rescue members, building up medical networks along with reasonable policies for information service, operating the consulting system for rescue 119 and so on. If these requirements are met, it is expected that the fire fighting departments in Jeju province can cope with every accident and disaster a little more rapidly and quickly in compliance with local needs, so that they can keep their own position as a public fire fighting organization which may be trusted by the public.

  • PDF

A Study on The Improvement of the Leagal Study on Special Fire Safety Inspection System (법과 제도적 관점에서 본 소방특별조사의 개선방안)

  • Lee, Jae Wook;Jeong, Gi Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.7 no.3
    • /
    • pp.545-552
    • /
    • 2021
  • Under the Act amended on August 4, 2011, a special fire-fighting investigation was conducted by the relevant person (owner, manager, oil refineries), and the responsibility was also given to the relevant person. Instead of directly entering all existing fire-fighting targets and investigating the maintenance and management status of fire-fighting facilities, the fire-fighting agency selects and visits some targets every year, checks the maintenance and management status of fire-fighting facilities, corrects them, and imposes fines, etc. Reasons for the introduction of the system were the establishment of a private autonomous correction system by strengthening the responsibility of officials, lack of firefighting professionals, possible corruption due to frequent public contact, and responsibility of fire agencies. However, many problems arose even after the introduction of a special fire investigation system. A special fire investigation, one of the fire safety systems, checks whether related public officials and especially fire officials are properly installed, maintained and managed in accordance with relevant laws. Special firefighting investigations were introduced as firefighting inspections at the time the firefighting law was enacted in 1958, and have undergone a revised process more than 30 times until recently. Firefighting Facility Installation, Maintenance and Safety Management Act", the existing firefighting inspection was changed to a special firefighting investigation and accepted. At the time of enactment of the Fire Service Act in 1958, a special firefighting investigation was introduced as a firefighting inspection, and until recently, more than 30 revisions have been made. In 2003, as the existing fire fighting system was divided into four laws, it was approved by changing the existing fire fighting inspection to a special fire fighting investigation in the "Fire Fighting Facility Installation, Maintenance and Safety Management Act".

Performance Comparison of Thermal Imagers with Uncooled and Cooled Detectors For Fire Fighting Application (비냉각형 적외선 센서를 이용한 열상시스템과 냉각형 적외선 센서를 이용한 열상시스템의 화재 진압 시 성능 비교)

  • Kim, Byung-Hyuk;Jung, Han;Kim, Young-Ho
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.13 no.2
    • /
    • pp.128-132
    • /
    • 2007
  • Thermal Imaging systems are reported to be crucial for fire fighting and beginning to be used by fire fighters. The performance of thermal imaging system is determined by both the radiation of infrared from the target and the attenuation of infrared signal in the optical path by the absorption, scattering, diffraction and reflection. In the scene of fire, water drops with various sizes such as vaporized water, wafer mist from sprinkler, and wafer to suppress the fire reside with various gas generated by burning. To measure the transmission of infrared radiation in the scene of fire, fire simulating system and thermal imagers with cooled detector which detects $3{\sim}5{\mu}m$ infrared and uncooled detector fabricated by the MEMS technology which detects $8{\sim}12{\mu}m$ infrared. are made. With thermal imagers and Ire simulating system, the change of thermal image with respect to the change of visibility controlled with the burned fas was measured. It was found that the transmission of infrared was not reduced by the burned gas, which could be explained by the long wavelength of infrared ray compared with visible ray. However, the transmission of infrared ray was largely reduced by the combination of burned gas and water mist supplied by sprinkler. This is contrary to the results of calculated transmission through the pure water mist and shows that the transmission of infrared ray is mostly affected by the compounds of water mist and burned gas. In this case, it was found that the uncooled detector which detects $8{\sim}12{\mu}m$ infrared ray is better than cooled detector which detects $3{\sim}5{\mu}m$ infrared ray for fire fighting.