• Title/Summary/Keyword: Fire-fighting equipments

Search Result 22, Processing Time 0.025 seconds

Study on Theoretical Research to Reduce Fire Risk of Solar Power System (태양광 발전 시스템의 화재 위험 감소 방안에 관한 이론적 연구)

  • Park, Kyong-Jin;Lee, Guen-Cull;Lee, Bong-Woo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.23 no.2_2
    • /
    • pp.219-224
    • /
    • 2020
  • This study is based on the principle of solar power system and fire breakout. The result of the survey indicates that a solar power system is vulnerable to fire due to lack of maintenance after the installation. Currently the national fire safety agency does not have standards and legal provisions for the installation and maintenance of solar power facilities. Therefore, it increases the risk of fire breakouts as well as possibility of electric shock for the firefighters during fire fighting. This results possible damages to the human and equipments. In this study is proposing an automatic fire extinguishing system to reduce the power generation of solar panels during fire breakouts. Also, propose an over load current alarm system and fire prevention measures for fire fighters. The results of this study will be used as basic data for further fire testing of solar power systems.

The Study of Fire Detector Circuit with Wireless Communication (무선통신기능을 갖는 화재감지기 회로에 대한 연구)

  • Baek, Dong-Hyun;Kim, Jang-Won
    • Fire Science and Engineering
    • /
    • v.24 no.1
    • /
    • pp.111-115
    • /
    • 2010
  • For the development of fire detector equipments that was fused independent type of fire detector and a wireless communication function, this paper adopted a signal processing method of an independent formation fire sensor by a ZigBee communication method, and it was designed that the combinations of fire detector and wireless communications network were enabled. When a fire occurred, output voltage of a fire detector was 0.4 V, the movement pulse width was $600{\mu}s$, and that was confirmed by an experiment. When it has lookout state, LED worked by 30 s cycle and working current is 0.12 mA. When a fire occurred, LED worked by 0.5 s cycle and working current was 7 mA, and through this experiment of power source, Chamber tester, smoke tester,IRED, LED lighting, the propriety of the method that we showed in this paper confirmed.

A Study on Fire Hazard Analysis and Smoke Flowing for the Semiconductor Manufacturing Process (반도체 제조공정의 연기유동에 관한 연구)

  • Han, Soo-Jin;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.9 no.1
    • /
    • pp.197-211
    • /
    • 2007
  • The power of semiconductor, Korea is continuously constructing semiconductor production line for keeping a front-runner status. however, studies and data about potential risks in semiconductor factory are still short. If fire does not initially suppressed, the fire causes a great damage. To decrease fire risk factors, in addition to fire fighting safety equipment, more important thing is how to design and construct fire protection system. The current fire protection codes about semiconductor factory come under functional law, and this law is short of consideration about particularity of factory. The existing prescriptive fire codes depending on experience compose without evident engineering verifications, thus equipments which is created by the current prescriptive fire code may bring about a variety of problems. For example, the design under the current regulation can not cope with the excessive investments, low efficiencies, and the diversifying construction designs and be applied to the quick changes of new technologies. Ergo, an optimal design for fire protection is to equip fire protection arrangements with condition and environment of production field. Manufacturing factory of semiconductors is a windowless airtight space. And for cleanliness, there exists strong flow of cooperation. Therefore, there is a need for fire safety design that meets the characteristic of a clean room. Accordingly, we are to derive smoke flow according to cooperation process within a clean room and construction plan of an optimal sensor system. In this study, in order to confirm the performance of proposed smoke-exhaust equipment and suggest efficient smoke exhaust device when there is a fire of 1MW of methane in the clean room of company H, we have implemented fire simulation using fluid dynamics computation.

The Effect of Fire Plume on the Characteristics of Air Flow and $CO_2$Extinguishant Transfer (화재화염이 유동 및 $CO_2$소화제 전달특성에 미치는 영향)

  • 박찬수;최주석
    • Fire Science and Engineering
    • /
    • v.16 no.4
    • /
    • pp.33-43
    • /
    • 2002
  • To analyze the effect of fire plume on the characteristics of air flow and $CO_2$, extinguishant transfer when extinguishant is injected into a closed space similar to a marine engine room with fire plume, a numerical simulation on a space was performed. Flow fields and $CO_2$, concentration fields are calculated according with the variation of the location of nozzles. In all cases excepting the case of all nozzles located in the right side of ceiling, an counterclockwise & clockwise recirculation flow was found in the region of the right and left side of the nozzle on the second floor and such a recirculation flow greatly affected mass transfer and the diffusion process of $CO_2$, extinguishant. In the region of the first floor with fire plume, the diffusion process of $CO_2$, extinguishant was in agreement with the extension process of recirculation flow. It is considered that the result of this study can be useful to designing the arrangement of nozzles for the $CO_2$ fire fighting equipments in a marine engine room.

The Transfer Characteristics of $CO_2$ Extinguishant According with the Location of Fire Plume (화재위치에 따른 $CO_2$소화제 전달특성)

  • 박찬수;최주석
    • Fire Science and Engineering
    • /
    • v.17 no.4
    • /
    • pp.28-35
    • /
    • 2003
  • To analyze the transfer characteristics of $CO_2$ extinguishant when extinguishant is injected into a closed space similar to a marine engine room, a numerical simulation was performed. Flow and Concentration fields are calculated according with the variation of the fire plume,s location. The results show that tile variation of fire plumes, location greatly effected on the flow patterns and the characteristics of $CO_2$ extinguishant transfer. In case of the fire plume located at left region of the 2nd floor center in the engine room consisted of first and second floor, The effects similar to the air curtain is found and cut off the mass transfer. In the characteristics with hight, the iso-concentration line below the extinguishable limit is formed in the left region of the 1st and 2nd floor center after the $CO_2$ extinguishant is completely injected. therefore I think that the results of this study are considered to arrange the $CO_2$ injection nozzles for the $CO_2$ fire fighting equipments.

The Effect of Nozzle's Location & Injection Angle on the Characteristics of Air Flow and $CO_2$ Extinguishant Transfer (노즐 위치 및 분사각이 공기유동 및 $CO_2$ 소화제 전달특성에 미치는 영향)

  • 박찬수
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.26 no.4
    • /
    • pp.472-484
    • /
    • 2002
  • To analyze the characteristics of air flow and $CO_2$ extinguishant transfer when extinguishant is injected into a closed space similar to marine engine room, a numerical simulation on a space was performed. Flow fields and $CO_2$ concentration fields are calculated according with the variation of the location & injection angle of nozzles. The results of simulation showed that the pattern of recirculation flow was affected greatly with the location & injection angle of nozzles and such a recirculation flow accelerated mass transfer of $CO_2$ and greatly affected the diffusion process of $CO_2$ extinguishant. It is considered that this result of this study can be useful to designing the arrangement of nozzles for the $CO_2$ fire fighting equipments in a marine engine room.

The analysis of field condition for fire-fighting equipments in entertainment places (유흥장의 방재설비 관련 실태분석)

  • Yi, Geon-Ho;Kim, Gi-Hyun;Kim, Chong-Min;Bang, Sun-Bae;Kim, Han-Sang;Bae, Seok-Myung
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2004.11a
    • /
    • pp.281-285
    • /
    • 2004
  • 국민의 생활수준 향상에 따른 서비스산업의 발달로 화재위험 건물로 분류되는 나이트클럽과 같은 유흥장은 전국적으로 늘어나고 있는 추세이며, 이들 시설의 이용객수도 점점 증가하고 있다. 또한 규모가 대형화되고 화려해짐에 따라 전기설비도 복잡하고 다양해지고 있다. 특히 한정된 장소에 수많은 전기설비의 설치로 전선 및 케이블이 집중되어 시공되는 유흥장의 특성상 화재의 위험으로부터 항상 노출되어 있으며 다중이 이용하는 시설로써 화재 발생시 대형 참사가 일어날 가능성이 상존하고 있다. 그러나 화재시 인명이나 재산 피해를 최소한으로 줄이기 위한 방재설비에 대한 인식은 상대적으로 부족한 것이 현실이다. 본 논문에서는 유흥장 방재설비에 대한 관련법이나 규정을 소개하고 유흥장의 현장실태조사를 통한 문제점을 파악하여 유흥장 방재설비의 설계 시공 및 유지관리에 대한 개선 방안을 제공하고자 한다.

  • PDF

A study on the Development of Low-loss Type Mold Autotransformers (저손실형 몰드 단권변압기 개발)

  • Lee, Jong-Su;Shin, Myung-Ho;Mun, Byung-Chul
    • Proceedings of the KIEE Conference
    • /
    • 2003.10b
    • /
    • pp.92-94
    • /
    • 2003
  • The autotransformer currently used on the electric railway system is made of class A insulation material and uses the paper insulation method. As a power converter supplying power to the trolley wire, the autotransformer is one of critical equipment in the railway system. In the autotransformer, load irregularly changes and overload often occurs. These cause overheating of the autotransformer and facilitate deterioration of the autotransformer resulting in burnout accidents due to insulation breakdown. Also, the current autotransformer has poor insolation and short-circuit strength which often badly affect the service life of the transformer, and needs to improve its quality urgently. To overcome one of existing shortcomings of the mold transformer, manufacturers use epoxy resins that have superior flame retardancy to get rid of fro and explosion possibilities during accidents. Currently, new mold transformers are used in indoor distribution facilities with fire-fighting equipments. Coils molded in epoxy resins do not have their insulation performance compromised by humidity, dust, etc enabling easy inspection and maintenance. Comparing to the oil immersed transformer, the mold transformer does not have any concern about environmental pollutions by oil leak or replacement Therefore, to reduce breakdowns and improve reliability of the autotransformer, it is necessary to develop a new mold autotransformer with low loss suitable for our environment to suppress breakdowns of the autotransformer and improve the reliability. This study is about development of a low-loss mold autotransformer necessitated by reasons mentioned earlier.

  • PDF

Development of M2M-based Underground Space (subway) Disaster Response Network and EL Display Integrated Board (M2M기반 지하공간(지하철) 재난대응 네트워크 및 EL 디스플레이 통합 보드 개발)

  • Park, Miyun;Kwon, Segon;Park, EunChurn;Lee, Jeonhun
    • Journal of the Society of Disaster Information
    • /
    • v.13 no.4
    • /
    • pp.422-441
    • /
    • 2017
  • Notifying emergency evacuation methods, accurate disaster location and evacuation route guidance can be very active alternatives to quickly minimize evacuation and casualties in disaster situation in the development of subway disaster prevention detection system that detects the disaster signs at the subway station early on the basis of Internet of things and leads passengers to evacuate. It's not easy to ensure perfect functioning of fire fighting facilities and equipments due to underground space structure with narrow exits. Therefore, we developed disaster provision EL Display integrated board that can induce the most efficient evacuation and the field experiment was conducted to examine the practical application in this study. Especially the applicability was verified by field application test because there is no case in which EL panels are used to evacuate disasters.

The study for musculoskeletal symptoms and job stress in firemen (소방관의 근골격계 증상과 직무 스트레스에 관한 연구)

  • Kim, Jung Man;Suh, Byung Seong;Jung, Kap Yeol;Kim, Dong Il;Kim, Won Sool;Cho, Han Seok;Kim, Jin Wook;Kwon, Jae;Yoon, Dong Young;Kim, Jung Il;Roh, Young-Man
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.17 no.2
    • /
    • pp.111-119
    • /
    • 2007
  • Firemen are directly exposed to various harmful chemicals, physical factors and mental stress during rescue and fire-fighting. In fire extinguishing, unstable posture, poisonous gas, dust, high temperature and heavy equipments are possible hazardous factors. The alertness for emergency, shift work, job strain and stress are also possibly hazardous. Therefore, this study aimed to investigate the prevalence of musculo-skeletal symptoms and job stress and to determine risk factors in firemen. This study was carried out in a group of 226 firemen in Busan City, Korea. Standardized Nordic Questionnaire was used to investigate the prevalence of musculo-skeletal symptoms and Psycho-social Well-being Index (abbreviated PWI) was used to investigate the prevalence of job stress. General and occupational characteristics were included education, marital status, alcohol and smoking history, working duration, and work shift system. Body mass index (BMI) scores were calculated by physical examination including height and weight. Concerning musculo-skeletal complaints, the commonest site was neck, and shoulder, lower back, upper back were the next. Complaint site above one area of body was about 80%. From multiple logistic regression analysis, working duration was significant variable in musculo-skeletal symptoms. Odds ratio were 15.4 in working duration. About 16.8% was high risk stress group. From multiple logistic regression analysis, shift work and alcohol drinking were significant variables in PWI scores. Odds ratios were 2.25 in shift work. Accordingly, interventions are needed for health promotion of long term and shift worker.