• 제목/요약/키워드: Fire-Safety door

검색결과 96건 처리시간 0.025초

제연구역 출입문의 차압 측정에 따른 작동패턴 해석 (An Analysis of Operation Patterns based upon Actual Measurements of Pressurization through Open Door in Smoke Control Zone)

  • 이재오;최충석
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2011년도 춘계학술논문발표회 논문집
    • /
    • pp.245-247
    • /
    • 2011
  • 본 연구에서는 제연구역과 옥내와의 차압 및 출입문의 폐쇄력 측정을 통해 제연구역 출입문의 작동패턴을 해석하였다. 이를 통해 제연구역 출입문의 폐쇄력 측정시 정확한 측정을 위해 출입문을 완전히 폐쇄한 상태에서 측정을 하여야 하며, 문의 크기에 비례하여 증가하는 폐쇄력을 고려한 제연설비 설계에 대한 근거를 제시하였다.

  • PDF

지하철 승강장 형식에 따른 정량적 화재 위험성 평가 (Quantitative Fire Risk Assesment for the Subway Platform Types)

  • 이동호;김하영
    • 한국안전학회지
    • /
    • 제21권6호
    • /
    • pp.1-6
    • /
    • 2006
  • Subway platform is divided into Side-platform type and Center-platform type. In this study does quantitative fire risk assesment of subway platform types in numerical analysis by using CFD model. From the result of this study, 1) All exhaust mode was low-end result it seems most fire risk at Side-platform station. 2) All exhaust mode was low-end result it seems most fire risk at Center-Platform station. 3) When comparing same type exhaust mode of Side-platform and Center-platform that last thing was visible $9.1{\sim}72.34%$ low-end fire risk. Center-platform is more opera-tive than Side-platform that reduce fire risk when that was same dimension and external environment. Designer look upon a fire characteristic of subway platform types when he make smoke control air volume and platform area design.

Analyzing Safety Factors of Swimming Pool

  • KWON, Yeon Taek;SEO, Myung Seok;SEO, Won Jae
    • Journal of Sport and Applied Science
    • /
    • 제5권1호
    • /
    • pp.11-15
    • /
    • 2021
  • Purpose: Swimming industry is improving faster than the other types of sport industries and populations of participating swimming are promptly increasing. Lack of recognition of fire safety in swimming facilities is issues related-studies has only recently begun to pay attention. This study is to review and extract fire safety factors for managing swimming pool. Research design, data, and methodology: The study reviewed related-ordinances, governmental documents, and studies discussing safety management of sport facility. Given the literature review, the study produced an initial construct presenting items and factors including fire safety elements and experts' review were conducted to ensure conceptual validity. Finally, the study generated the final factors and subitems representing fire safety elements for swimming pool management. Results: The study confirms factors and elements as follows: the study identifies fire safety equipments as first factors presenting fire extinguisher' place, its proper run, check list and so forth, Second factor is warning system including fire warning equipment, its proper operation, sprinkler and its proper operation, switch and lamp of emergency panel and their proper run and so on. Third factor is evacuation system including a fire exit, exit sign, broadcasting equipment, and their proper operation, and so on. The other factors are an electronic equipment and its subelements, gas management including safety management of LPG, gas valve, pipe, and fire prevention facility including a fire door and its proper operating. Conclusions: Regarding safety management of swimming pool, further discussions and implications were made, and future directions for related-studies were discussed.

건축물의 화재 시 피난안전성 평가 개선을 위한 시뮬레이션 분석 연구 (A Study on the Analysis of Simulation for Improvement Evacuation Safety Assessment of Building in Fire)

  • 김혜원;김윤성;이병흔;진승현;구인혁;권영진
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2020년도 가을 학술논문 발표대회
    • /
    • pp.107-108
    • /
    • 2020
  • There is a need to analyze various factors in evacuation safety assessment of building in fire. In the current performance based design, evacuation safety assessment in case of fire is being conducted through the simulation as FDS and Pathfinder. However, the location and size of the door, the location of evacuation in the event of a fire are not considered when design. Accordingly, it is difficult to determine the worst case scenario considering the actual fire. Therefore in this study, in this study, we will propose an appropriate evaluation plan through simulation considering the worst-case scenario that may occur in case of fire.

  • PDF

백드래프트의 중력흐름에 미치는 구획실 내부 초기조건 및 개구부 형상의 영향 (Effects of Initial Condition and Opening Geometry of a Compartment on the Gravity Current in the Backdraft)

  • 박지웅;오창보;한용식;도규형
    • 한국안전학회지
    • /
    • 제30권6호
    • /
    • pp.18-25
    • /
    • 2015
  • Computational study of a gravity current prior to the backdraft was conducted using fire dynamic simulator (FDS). Various initial conditions of mixture compositions and compartment temperature as well as four opening geometries (Horizontal, Door, Vertical, and Full opening) were considered to figure out their effects on the gravity current. The density difference ratio (${\beta}$) between inside and outside of compartment, the gravity current time ($t_{grav}$) and velocity ($v_{grav}$), and non-dimensional velocity ($v^*$) were introduced to quantify the flow characteristics of the gravity current. Overall fluid structure of the gravity current at the fixed opening geometry showed similar development process for different ${\beta}$ conditions. However, $t_{grav}$ for entering air to reach the opposed wall to the opening geometry increased with ${\beta}$. Door, Vertical, and Horizontal openings where openings are attached on the ground showed similar development process of the gravity current except for Horizontal opening, which located on the middle of the opening wall. The magnitude of $v_{grav}$ at fixed ${\beta}$ was, from largest to smallest, Full > Vertical > Door > Horizontal, but it depended on both the size and location of the opening. On the other hand, $v^*$ was found to be independent to ${\beta}$, and only depended on the geometry of the opening.

공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관한 수치해석적 연구 (Numerical Study on Air Egress Velocity of Ancillary Room Pressurization Systems in Apartment Fires)

  • 김병준;양영;신원규
    • 한국화재소방학회논문지
    • /
    • 제34권4호
    • /
    • pp.78-86
    • /
    • 2020
  • 본 연구에서는 공동주택 화재 시 부속실 가압 시스템의 방연풍속에 관하여 수치해석을 수행하였다. 수치해석을 통해 댐퍼의 급기량과 방화문에서의 방연풍속의 관계식을 선형적으로 나타내었고 국가화재안전기준인 방연풍속 0.7 m/s를 만족하는 댐퍼의 최소유량을 선정할 수 있었다. 댐퍼의 최소유량을 적용하여 댐퍼의 급기 방향과 설치 높이에 따라 방연속도를 분석하였다. 댐퍼의 급기 방향이 상향인 경우와 댐퍼가 높게 설치되었을 때 댐퍼의 급기 방향이 하향인 경우보다 방화문 상부에서 더 큰 방연풍속을 나타내었고 누출된 연기 농도가 더 낮은 것을 확인할 수 있었다. 따라서 방화문 상부에서 큰 방연풍속을 확보하는 것이 제연에 더 효율적일 것으로 판단된다.

유아교육기관의 실내 환경 안전 실태에 관한 연구 (A Study on the condition of Indoor environmental safety in kindergarten)

  • 최은진;한혜련
    • 한국실내디자인학회:학술대회논문집
    • /
    • 한국실내디자인학회 2008년도 춘계학술발표대회 논문집
    • /
    • pp.242-246
    • /
    • 2008
  • This study is to research on the condition of safe environment of kindergartens. This study is to supplement the preceding study which was based only on survey to show the result and analyze the condition and problems of the safety of kindergartens to suggest the basic database of indoor environment that cause accident. First as a theoretical study, we analyze the preceding studies according to the related regulations. And we made checklist based on this and visited and investigated two kindergartens where applied for the case study As the result, we could understand factors that can cause accidents from classroom, corridor, door, stairs, balustrade, toilet, kitchen, front door, and fire exit/shelter. Especially, in case of fire exit/shelter, the whole renewal of kindergarten was necessary which is difficult. But, though it can not be advanced right away, they should try to have facility expansion and repair works gradually. And for more study on this, active cooperation from kindergartens are in need.

  • PDF

제연구역 방화문의 각속도 변화와 폐쇄 조건 분석 (A Study on the Conditions of Injection Pressurization in the Smoke-Control Zone II. Analysis of the Conditions for Closing Force of Fire Door with Variation of Angular Velocity)

  • 이창욱;김홍진;최영기;염문천;유홍선
    • 한국화재소방학회논문지
    • /
    • 제27권2호
    • /
    • pp.6-10
    • /
    • 2013
  • 본 연구는 풍도, 부속실, 거실 그리고 계단실로 구성된 구조물의 제연설비 성능에 관한 연구를 수행하고 급기 가압실의 안전성을 구현하기 위한 실험 자료를 구축하고자 하는데 목적이 있다. 이를 위해서 부속실 가압 및 차압 조절 설비와 방화문의 개폐력 측정 장치를 제작하였다. 본 주제는 부속실의 가압을 위한 설계유량과 폐쇄시 차압이 동일한 경우 방화문의 크기와 닫히는 각속도 증가에 따라서 폐쇄력을 분석하였다. 실험 결과 방화문의 크기와 닫히는 각속도가 증가 할수록 폐쇄력이 증가하였으며, 일정 각속도 이상으로 증가할 경우 폐쇄력이 일정하게 유지되는 임계각속도가 존재하는 것을 확인하였다.

복층건물의 출입문 개방여부에 따른 화재온도분포 및 독성가스 농도 변화특성에 관한 연구 (A Study on Characteristics of Fire Temperature and Concentration of Toxic Gases while the Door Opening or Closed on Multi-layered Construction)

  • 이정윤;김정훈;김응식;김홍
    • 한국안전학회지
    • /
    • 제32권2호
    • /
    • pp.72-77
    • /
    • 2017
  • In S. Korea, recently, building fire accidents of residential accommodations or recreational facilities have taken place more frequently than before. Among various building constructions, Multi-layered structure, such as office-residential complex, are mostly made in S. korea. $O_2$, $CO_2$, CO, $NO_x$, $SO_x$, and HCl, these gases has toxic hazard and harmful for human body. And it is predicted that different concentration of released gases from diesel pool fire with upper and lower layer. Therefore, this study reports the fire characteristics of Multi-layered structure by analyzing the fire behavior and concentration of combustion gases of a experimental compartment via real scale fire experiment, in order to predict risks and secure safety for similar fire accidents.

제천 스포츠센터 화재의 다수 사상자 발생원인 분석 -초기대응과 관리적인 측면을 중심으로- (Analysis of the Causes of Casualties of Jecheon Sports Center Fire - Focus on an Initial Response and Management -)

  • 이의평
    • 한국화재소방학회논문지
    • /
    • 제32권5호
    • /
    • pp.57-66
    • /
    • 2018
  • 29명이 사망하고 40명이 부상을 입은 제천 스포츠센터 화재 사례에 대해 다수 사상자가 발생한 원인을 초기대응과 관리적인 측면을 중심으로 분석하였다. 초기대응 측면은 119신고 지연, 2층 세신사 비상구로 피난유도를 하지 않음, 1층과 3층 비상계단쪽 방화문 개방 상태 유지, 3층 주계단실 쪽 방화문 닫지 않음, 비상방송을 하지 않음으로 분석하였다. 관리적인 측면은 1층의 스프링클러설비 알람밸브 폐쇄, 소방펌프 제어반에서 기동 정지 위치에 놓음, 주차장 반자 안 누수 및 누전 방치, 2층 여탕의 휴게실 피난구유도등이 가려져 있고 비상구에 물건이 적치됨, 2층 자동문의 조작버튼 불량상태로 방치, 형식적인 소방안전관리, 소방시설 부실한 자체점검, 방화셔터와 배연창 미작동으로 분석하였다.