• 제목/요약/키워드: Fire-Safety door

검색결과 95건 처리시간 0.019초

태양열 해수담수화를 위한 증발식 MEMS(Multi-Effect-Multi-Stage)담수기 성능 실험 연구 (Experimental Study on Performance of MEMS(Multi-Effect-Multi-Stage) Distiller for Solar Thermal Desalination)

  • 주홍진;전용한;곽희열
    • 한국태양에너지학회 논문집
    • /
    • 제33권3호
    • /
    • pp.91-98
    • /
    • 2013
  • In this study, we have carried out development and performance evaluation of optimized MEMS(Multi-Effect-Multi-Stage) fresh water generator with $7m^2/day$ for solar thermal desalination system. The developed MEMS was composed of high temperature part and low temperature part. This arrangement has the advantage of increasing the availability of solar thermal energy. The MEMS consists of 2 steam generators, 5 evaporators, and 1 condenser. Tubes of heat exchanger used for steam generators, evaporators and condenser were manufactured by corrugated tubes. The performance of the MEMS was tested through in-door experiments, using an electric heater as heat source. The experimental conditions for each parameters were $20^{\circ}C$ for sea water inlet temperature to condenser, $8.16m^2$ /hour sea water inlet volume flow rate, $70^{\circ}C$ for hot water inlet temperature to generator of high temperature part, 3.6 4.8, 6.0 $m^2/hour$ for hot water inlet volume flow rate. As a result, The developed MEMS was required about 85 kW heating source to produce $7m^2/day$ of fresh water. It was analyzed that the performance ratio of MEMS was about 2.6.

초고층 건축물에서 엘리베이터 구동이 부속실과 화재실 간 차압형성에 미치는 영향연구 (The Study on the Effect of Elevator Movement on the Pressure Difference between Vestibule and Living room in High-rise Buildings)

  • 박영기;홍기배;유홍선
    • 한국산학기술학회논문지
    • /
    • 제19권1호
    • /
    • pp.85-91
    • /
    • 2018
  • 최근 초고층 건축물에서 화재로 인해 많은 인명피해가 발생하고 있다. 특히, 화재 발생시 생성되는 유독성 가스 및 연기로 인해 많은 사망자가 발생하고 있다. 이러한 인명피해를 줄이기 위한 방안으로 제연시스템이 도입되어 있다. 제연시스템은 초고층 건축물에서 연기의 확산을 방지하고 재실자의 안전한 피난을 도와주는 장치이다. 또한, 엘리베이터를 이용한 피난은 초고층 건축물에서 필수적인 피난 방법으로 여겨진다. 하지만, 엘리베이터 구동시 생성되는 강력한 압력장 및 유동변화로 인해 제연시스템의 성능확보에 영향을 미친다. 따라서, 본 연구에서는 성능설계위주의 샌드위치 가압방식이 적용된 초고층 건축물에서 엘리베이터 구동에 따른 제연성능 확보에 미치는 영향을 실험 및 수치해석 연구로 수행하였다. 실제 초고층 건축물에서 발생되는 창문, 방화문 그리고 엘리베이터의 누설면적은 화재안전기준 및 면적비를 이용하여 산출하였다. 실제 엘리베이터 속도 7 m/s~17 m/s에 해당하는 20 m/s~100 m/s로 동역학적 상사를 통해 엘리베이터 속도를 변경하였다. 그 결과 엘리베이터 속도가 빠르면 빠를수록 부속실과 화재실 간 차압이 크게 발생하였으며 관계식은 ${\Delta}P=40{\cdot}{\exp}$(-Ves /-104.7)-23.735로 산출되었다. 본 연구 결과는 초고층 건축물에서 엘리베이터 구동을 고려한 제연시스템 설계 자료로 활용이 가능하다.

NFPA 101에 의한 아파트 한 세대당 적정 수용인원 분석 (An Analysis of the Appropriate Number of People Per Apartment Household According to NFPA 101)

  • 조지은;공하성
    • 문화기술의 융합
    • /
    • 제6권4호
    • /
    • pp.331-337
    • /
    • 2020
  • 이 연구는 NFPA 101기준에 의한 대상아파트인 27층 아파트에서 한 세대 당 적정 수용인원 수를 피난시뮬레이션을 통해 분석하였다. 분석결과는 다음과 같다. 첫째, 한 세대당 3명이 거주하는 경우 아파트 총 세대수는 156명이고 5분 이내에 대피인원을 확인 한 결과 85.25%가 대피한 것으로 나타났다. 둘째, 한 세대당 4명이 거주하는 경우 아파트 총 세대수는 208명이고 5분 이내에 대피인원을 확인한 결과 81.25%가 대피한 것으로 나타났다. 셋째, 한 세대당 5명이 거주하는 경우 아파트 총 세대수는 260명이고 5분 이내에 대피인원을 확인한 결과 71.92%가 대피한 것으로 나타났다. 마지막으로 한 세대당 6명이 거주하는 경우 아파트 총 세대수는 312명이고 5분 이내에 대피인원을 확인한 결과 62.82%가 대피한 것으로 나타났다. 피난시간의 단축방안으로 실내인원 수, 건물 층수, 계단 경사도, 사용자의 특성에 따른 계단 폭의 결정, 계단 환기조건을 반영한 설계, 옥외피난계단, 양방향 계단, 피난용 승강기, 층 중간에 건물외부로 대피할 수 있는 피난안전구역 등의 설치, 옥상에 비상문 자동개폐장치의 의무설치로 인한 옥상대피를 용이하게 하는 등의 방안이 필요하다.

독거노인을 위한 융복합 실내 보온용 텐트디자인에 관한 연구 (A study on Indoor Insulating Tent Design for Senior Citizens who Live Alone)

  • 이대현;김상식
    • 한국과학예술포럼
    • /
    • 제37권2호
    • /
    • pp.219-230
    • /
    • 2019
  • 통계청에 따르면 2017년 기준으로 국내 65세 이상 노인 인구는 700만명을 돌파하였고 이중 독거노인의 수는 130만 명을 넘어섰다고 하였다. 독거노인들은 대부분 절대적 빈곤(68.5%가 월 소득 50만원 미만)으로 우리사회의 사각지대에 놓여져 있는 상황에서 기본적인 생활에 곤란을 겪고 있는 실정이다. 특히 겨울철 취약계층의 독거노인들의 난방은 심각하며 그나마 전기난로나 전기장판 등 전기 안전용품 취급 부주의로 화재사고도 빈번하게 일어나고 있는 실정이다. 실내용 텐트제품들이 독거노인들에게서 이용되어지고 있는 가장 큰 이유로는 에너지 절감과 따뜻한 수면, 화재 안전 등으로 나타났다. 이러한 실내용 텐트의 시장 확대에 따라 본 연구의 목적은 저소득 독거노인에게 적합한 실내용 텐트가 필요하다고 판단하였고, 그에 따른 이용성, 휴식, 보관 등의 효율성을 개선시키는데 목표를 두었다. 따라서 본 논문은 기존 브랜드의 제품들에서 기초 조사를 하여 장·단점을 분석하여 기존 판매 되고 있는 제품에서 소비자들이 원하는 요구를 파악할 수 있었다. 이어 디자인모델을 통한 소비자선호도 조사를 실시하여 설치편리성, 공간 활용성, 외관디자인 측면에서 가장 우수한 Zabara type을 선정하였다. 선정 결과를 토대로 제품디자인 제작 및 최종 프로토타입을 완성하였다. 연구 결과 및 내용은 다음과 같다. 첫째, 실 사용자의 사용성 조사와 인터뷰를 통해 제품 개발 시 미처 인지하지 못했던 요소를 파악할 수 있었다. 둘째, 프로토타입의 효과적인 부분에서는 기대 이상으로 고령자들이 쉽게 그리고 빠르게 설치 및 접을 수 있었다. 이러한 연구 결과를 바탕으로써 향후 독거노인 뿐만 아니라 다양한 사용자가 실내에서 또 하나의 편안한 개인공간으로써 활용될 수 있을 것으로 기대한다.

설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰 (Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014)

  • 이대영;김사량;김현정;김동선;박준석;임병찬
    • 설비공학논문집
    • /
    • 제27권7호
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.