• Title/Summary/Keyword: Fire-Performance

Search Result 2,070, Processing Time 0.034 seconds

IoT-based Smart Tunnel Accident Alert System (사물 인터넷 기반의 스마트 터널 사고 경보 시스템)

  • Ki-Ung Min;Seong-Noh Lee;Yoon-Hwa Choi;Yeon-Taek Hong;Chul-Sun Lee;Yun-Seok Ko
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.19 no.4
    • /
    • pp.753-762
    • /
    • 2024
  • Tunnels have limited evacuation areas, and It is difficult for cars coming from behind to recognize the accident situation in front. Since an accident is very likely to lead to a serious secondary accident, a IoT-based smart tunnel accident warning system was studied to prepare for traffic accidents that occur in tunnels. If the measured values from the flame detection sensor, gas detection sensor, and shock detection sensor in the tunnel exceed the standard, it is judged to be an emergency situation and an alert system is designed to operate. The accident information message was designed to be displayed on the LCD and transmitted to drivers inside and outside the tunnel through a Wi-Fi communication network. A performance test system was established and performance evaluation was performed for several accident scenarios. As a result of the test, it was confirmed that the accident alert system can accurately detect accidents based on given reference values, perform alert procedures, and transmit alert messages to smart phones through Wi-Fi wireless communication. And through this, its effectiveness could be confirmed.

Application and Development Strategies of a Secure Real-Time Operating System in Weapon Systems within the Defense Sector (국방분야 보안 RTOS의 무기체계 적용 및 발전 방안)

  • Sang-Seung Lee;Keun-Ha Choi;Seung-Hyeon Hwang;Hyun-Ji Kim;Kyung-Deok Seo;Hwa-Eun Seong
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.5
    • /
    • pp.189-193
    • /
    • 2024
  • As cyber threats increase in the defense sector, the security of weapon system software is becoming increasingly important. Currently, most of the embedded software installed in domestic weapon systems operates based on foreign real-time operating systems(RTOS) that have no security. As a result, the localization and security enhancement of embedded software for weapon systems have emerged as urgent tasks. This study aims to propose the application and development strategies of secure RTOS for weapon systems. To this end, we examined the technological trends of domestic and foreign RTOS and secure RTOS, and analyzed the problems of current embedded software in weapon systems. The results revealed major issues such as low localization, vulnerability to cyber attacks, difficulty in maintenance, increased costs, and loss of opportunities for accumulating technological capabilities. An investigation of the current status of embedded software applied to existing weapon systems found that embedded SW are in operation across all fields, including maneuver, firepower, protection, command and control, communication, naval vessels, and aircraft. Among them, 99% rely on foreign RTOS such as VxWorks. A review of the core functions and applicability of secure RTOS to weapon systems suggests that it can be applied to key areas requiring real-time performance and security, such as fire control, navigation devices, and flight control in existing and future weapon systems. However, ensuring performance and reliability, securing verification and compatibility, and systematic government support were raised as prerequisites.

Recent Progress in Air-Conditioning and Refrigeration Research: A Review of Papers Published in the Korean Journal of Air-Conditioning and Refrigeration Engineering in 2014 (설비공학 분야의 최근 연구 동향: 2014년 학회지 논문에 대한 종합적 고찰)

  • Lee, Dae-Young;Kim, Sa Ryang;Kim, Hyun-Jung;Kim, Dong-Seon;Park, Jun-Seok;Ihm, Pyeong Chan
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.27 no.7
    • /
    • pp.380-394
    • /
    • 2015
  • This article reviews the papers published in the Korean Journal of Air-Conditioning and Refrigeration Engineering during 2014. It is intended to understand the status of current research in the areas of heating, cooling, ventilation, sanitation, and indoor environments of buildings and plant facilities. Conclusions are as follows. (1) The research works on the thermal and fluid engineering have been reviewed as groups of heat and mass transfer, cooling and heating, and air-conditioning, the flow inside building rooms, and smoke control on fire. Research issues dealing with duct and pipe were reduced, but flows inside building rooms, and smoke controls were newly added in thermal and fluid engineering research area. (2) Research works on heat transfer area have been reviewed in the categories of heat transfer characteristics, pool boiling and condensing heat transfer and industrial heat exchangers. Researches on heat transfer characteristics included the results for thermal contact resistance measurement of metal interface, a fan coil with an oval-type heat exchanger, fouling characteristics of plate heat exchangers, effect of rib pitch in a two wall divergent channel, semi-empirical analysis in vertical mesoscale tubes, an integrated drying machine, microscale surface wrinkles, brazed plate heat exchangers, numerical analysis in printed circuit heat exchanger. In the area of pool boiling and condensing, non-uniform air flow, PCM applied thermal storage wall system, a new wavy cylindrical shape capsule, and HFC32/HFC152a mixtures on enhanced tubes, were actively studied. In the area of industrial heat exchangers, researches on solar water storage tank, effective design on the inserting part of refrigerator door gasket, impact of different boundary conditions in generating g-function, various construction of SCW type ground heat exchanger and a heat pump for closed cooling water heat recovery were performed. (3) In the field of refrigeration, various studies were carried out in the categories of refrigeration cycle, alternative refrigeration and modelling and controls including energy recoveries from industrial boilers and vehicles, improvement of dehumidification systems, novel defrost systems, fault diagnosis and optimum controls for heat pump systems. It is particularly notable that a substantial number of studies were dedicated for the development of air-conditioning and power recovery systems for electric vehicles in this year. (4) In building mechanical system research fields, seventeen studies were reported for achieving effective design of the mechanical systems, and also for maximizing the energy efficiency of buildings. The topics of the studies included energy performance, HVAC system, ventilation, and renewable energies, piping in the buildings. Proposed designs, performance performance tests using numerical methods and experiments provide useful information and key data which can improve the energy efficiency of the buildings. (5) The field of architectural environment was mostly focused on indoor environment and building energy. The main researches of indoor environment were related to the evaluation of work noise in tunnel construction and the simulation and development of a light-shelf system. The subjects of building energy were worked on the energy saving of office building applied with window blind and phase change material(PCM), a method of existing building energy simulation using energy audit data, the estimation of thermal consumption unit of apartment building and its case studies, dynamic window performance, a writing method of energy consumption report and energy estimation of apartment building using district heating system. The remained studies were related to the improvement of architectural engineering education system for plant engineering industry, estimating cooling and heating degree days for variable base temperature, a prediction method of underground temperature, the comfort control algorithm of car air conditioner, the smoke control performance evaluation of high-rise building, evaluation of thermal energy systems of bio safety laboratory and a development of measuring device of solar heat gain coefficient of fenestration system.

A study on the effect of air velocity through a damper on smoke extraction performance in case of fire in road tunnels (도로터널 화재 시 집중배기방식의 배기포트 통과풍속이 배연성능에 미치는 영향에 관한 연구)

  • Ryu, Ji-Oh;Na, Kwang-Hoon
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.22 no.4
    • /
    • pp.347-365
    • /
    • 2020
  • In order to resolve traffic problems in urban areas and to increase the area of green spaces, tunnels in downtown areas are being increased. Additionally, the application of large port smoke extraction ventilation systems is increasing as a countermeasure to smoke extraction ventilation for tunnels with high potential for traffic congestion. It is known that the smoke extraction performance of the large port smoke extraction system is influenced not only by the amount of the extraction flow rate, but also by various factors such as the shape of the extraction port (damper) and the extraction air velocity through a damper. Therefore, in this study, the design standards and installation status of each country were investigated. When the extraction air flow rate was the same, the smoke extraction performance according to the size of the damper was numerically simulated in terms of smoke propagation distance, compared and evaluated, and the following results were obtained. As the cross-sectional area of the smoke damper increases, the extraction flow rate is concentrated in the damper close to the extraction fan, and the smoke extraction rate of the damper in downstream decreases, thereby increasing the smoke propagation distance on the downstream side. In order to prevent such a phenomenon, it is necessary to reduce the cross-sectional area of the smoke damper and increase the velocity of passing air through the damper so that the pressure loss passing through the damper increases, thereby reducing the non-uniformity of smoke extraction flow rate in the extraction section. In this analysis, it was found that when the interval distance of the extraction damper was 50 m, the air velocity passing through damper was 4.4 m/s or more, and when the interval distance of the extraction dampers was 100 m, the air velocity passing through damper was greater than 4.84 m/s, it was found to be advantageous to ensure smoke extraction performance.

A Study on the Estimation Method of the Repair Rates in Finishing Materials of Domestic Office Buildings (국내 업무시설 건축 마감재의 수선율 산정 방안에 관한 연구)

  • Kim, Sun-Nam;Yoo, Hyun-Seok;Kim, Young-Suk
    • Korean Journal of Construction Engineering and Management
    • /
    • v.16 no.1
    • /
    • pp.52-63
    • /
    • 2015
  • Business facilities among domestic architectures have rapidly been constructed along with domestic economic development. It is an important facility taking the second largest proportion next to apartment buildings among current 31 building types of fire department classification of 2012 year for urban architectures. The expected service life of business facilities is 15 years, but 70% of those in urban areas have surpassed the 15 year service life as of the present 2014. Thus, the demand for urgent rehabilitation of such facilities is constantly increasing due to the aging and performance deterioration of the facilities'main finishing materials. Especially, the business facilities are being used for the lease of company office or private office, and such problems as aging and performance deterioration of the facilities could cause less competitive edge for leasing and real estate value depreciation for the O&M (Operation & Management) agent and the owner, respectively. Therefore, an effective planned rehabilitation as a preventive measure according to the standardized repair rate by the number of years after the construction is in need in order to prevent the aging and performance deterioration of the facilities(La et al. 2001). Nonetheless, domestic repair/rehabilitation standards based on the repair rate are mainly limited to apartment buildings and pubic institutions, resulting in impractical application of such standards to business facilities. It has been investigated and analyzed that annual repair rate data for each finishing material are required for examination of the applicability of the repair rate standard for the purpose of establishment of a repair plan. Hence, this study aimed at developing a repair rate computation model for finishing materials of the facilities and verifying the appropriateness of the annual repair rate for each finishing material through a case study after collecting and analyzing the repair history data of six business facilities. The results of this study are expected to contribute to the planning and implementation of more efficient repair/rehabilitation budget by preventing the waste of unpredicted repair cost and opportunity cost for the sake of the business facilities' owners and O&M agents.

The effects of out of hospital ACLS simulation training on the paramedic's duty ability (구급대원의 전문심장소생술 시뮬레이션훈련이 직무수행융합능력에 미치는 영향)

  • Park, Yoo-Na;Cho, Byung-Jun;Kim, Gyoung-Young
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.4
    • /
    • pp.99-106
    • /
    • 2019
  • The purpose of this study is to analyze the effects of the simulation-based professional cardiac resuscitation training on the performance of professional cardiac resuscitation performed by paramedics in the pre-hospital stage and to provide basic data for effective cardiac resuscitation. This study is an experimental study of the design before and after the control of non-equality. The subjects of this study were 16 newly recruited paramedics from K firefighting school. The simulation training program and evaluation papers used as the evaluation tool were reviewed and commented by 6 ACLS simulation experts (2 emergency medical doctor, 2 emergency medical professors, 2 KALS instructors)Respectively. The training consisted of 30 minutes of theory and 150 minutes of practical training. The lecturer first demonstrated for 5 minutes, and after training by individual debriefing after individual training, individual and team education was conducted The evaluation scale was given a 5 - point Likert scale. The SPSS 22.0 program for Windows was used. The general characteristics of the subjects were analyzed for frequency, the examination of homogeneity between the experimental group and the control group wasfulfilled by t test, and the difference test between the groups of the two groups was performed using the paired t-test. The homogeneity test was able to confirm the homogeneity between experimental group and control group. In the evaluation of six ACLS techniques, it was proven that the experimental group that received the simulation training had better performance in all aspects than the non - training control group. The following are the technical items to be performed. 1. Electrocardiogram 2. Specialized instrument 3. Treatment of fluid 4. Leadership and teamwork 5. Medical guidance 6. Evaluation during transfer. It was proved that paramedics who received simulation training were improved on their job performance ability than general lecture and training group. Therefore, if simulation training and education are applied to a student in the synthetic course or an emergency resident who is engaged in clinical practice, he / she will be able to perform his / her duties more proficiently. It is expected that emergency services provided to patients with cardiac arrest will be improved.

Multi-Pole Low Pass Filter Embedded K-Band LTCC Upconverter (다중 폴 저역 통과 여파기가 내장된 K-대역 LTCC 주파수 상향 변환기)

  • Jeong, Jin-Cheol;Yom, In-Bok;Yeom, Kyung-Whan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.6
    • /
    • pp.621-629
    • /
    • 2008
  • This paper presents a low temperature co-fire ceramics(LTCC) Upconverter for a Ka-band OBS satellite transponder in order for size reduction which is one of the most important requirement for satellite components. A S-band low-pass filter(LPF), a K-band band-pass filter(BPF), and an upconverting MMIC mixer are embedded in the multi-layer structure of the upconverter. All spurious can be selectively rejected by employing a modified Elliptic low pass filter with a multi-pole structure for the S-band LPF. Also an improved performance of out-of-band rejection can be obtained. At the K-band BPF design a layer coupled configuration is employed. The upconverting mixer is an MMIC diode mixer with a double-balanced configuration. Conversion loss and isolation of the upconverter are 9 dB and 51 dBc, respectively. The size of the LTCC upconverter is only $8{\times}7{\times}0.6mm^3$ which is one-third for the thin-film based upconverter.

The Liquid Flame Proofing Agent's Permeating Effect of Wood Using Microwave (마이크로파를 이용한 목재의 액상방염약제 침투효과 연구)

  • Park, Cheul-Woo;Her, Jae-Won;Lim, Nam-Gi
    • Journal of the Korea Institute of Building Construction
    • /
    • v.11 no.3
    • /
    • pp.256-264
    • /
    • 2011
  • By implementing an analysis on the liquid flame proof agent infiltration of microwave-heated wood under soaking conditions (room temperature soaking, heat soaking), its correlation with wood temperature, and the structure of wood and permeating components after soaking in flame proof agent, which was carried out as basic research in order to improve the fire resistance performance of the wood itself, it is found that the infiltration increases as the microwave heating time increases, while for heat soaking, it is found that high infiltration as well as the stable permeability of flame proof agent is achievable. Also, when the wood temperature is more than $80^{\circ}C$, the infiltration by the flame proof agent increased, and a very even infiltration of flame proof agent was observed, which implies that the liquid flame proof agent has a dependency on temperature change of the wood as a condition to penetrate into the wood. As a result of fine structure analysis, the flame proof agent transfer between cells through pits was considered as a cause to increase the infiltration of flame proof agent, and it is also shown that for heat soaking among the permeating component analysis, as the crystallized flame proof agent around the heartwood and sapwood inner pits increases, the flame proof agent can penetrate into the the heartwood part.

The Patterns of Accidental Injury in Young Children and Effect of Safety Education on Their Mothers Performance of Preventive Measures (영유아의 사고유형 실태조사와 안전교육 효과 분석)

  • Song In-Ja;Han Jung-Suk
    • Journal of Korean Public Health Nursing
    • /
    • v.12 no.1
    • /
    • pp.55-74
    • /
    • 1998
  • In the past most major accidents resulted in death, but today there is a dramatic increase in the number of people who survive such accidents but who are left with permanent injury. Particularly, children who are inquisitive about their surroundings but immature in their ability to assess danger, are more vulnerable to accidents and their causes as well as to determine attitudes towards prevention. The main objective of the study was to assess the effectiveness of using an accident prevention manual for accident for accident prevention education. The study was a quasi-experimental study using a questionnaire format. The subjects of the study were 393 mothers of children attending six day care centers in Seoul. Data collection was done between May 1 and June 15, 1997. The tools used for the study were a questionnaire developed the researchers and a manual for accident prevention. The collected data were analyzed using SPSS. The results of the study are as follows: 1. Types of accidents included stabbing, bums, falls from heights, choking, falls on slippery surfaces, traffic accidents, drowning, poisoning, and electrical shock in that order of frequency. 2. The main causes of accidents in children were from cosmetics and household medications. 3. The most frequent locations of accidents in the home were the bathroom, kitchen, and stairways in that order. 4. For $90.4\%$ of children safety seats were not used when the ridding in a car. 5. In examining the parents' accident prevention practices, it was found that many parents used only . one electrical outlet for many appliances, tending to overload the electricity lines and that they were not practically concerned bout the flammability of children's pajamas, indicating a less than positive attitude towards fire prevention. 6. The parents had not provided their children with any instruction on accident prevention or on what to do after an accident had occurred. 7. After the use of pamphlet in an accident prevention education program, it was found that there was a statistically significant difference in the degree to which children carried out safety measures (t=14.96, p=.000) and in their safety habits (t=-1.67, p<.1) indicating an effectiveness in this method of education. The results of this study showed that there are many things in a child's environment that can cause accidents and that the possibility of an accident occurring is high. So nurses looking after children should be aware of the need for safety education to prevent accidents in the home and plan to provide appropriate educational material to help parents with this education.

  • PDF

Classification Schemes of Precast Beam-Column Connections According to Contribution of Deformation Components (변형기여분에 따른 프리캐스트 보-기둥 접합부의 분류방안)

  • Choi, Hyun-Ki;Choi, Chang-Sik
    • Journal of the Korea Concrete Institute
    • /
    • v.26 no.4
    • /
    • pp.545-553
    • /
    • 2014
  • This study suggested an integrated classification method for generalized characteristics of PC beam-column connection according to connection details. Quantifying the failure mode of PC-beam column connection and characteristics of corresponding details, this study suggested to use deformation contribution of each element of beam-column assemblage. According to the expected failure mode of beam-column connection assemblage, PC beam-column connection can be classified into 'equivalent monolithic system' and 'jointed system'. In this study, four test specimens were tested for verification of detailed classification method of PC beam-column connections. Test was carried out with typical beam-column connection test method. Load was applied at the top of test specimen and end of beams were restrained by hinge. In order to verify the deformation contribution of each test specimen, 34-LVDTs were mounted on test specimen. According to test results, deformation contribution of each test specimen have different characteristics. Deformation characteristics of joint and other components which are quantified by test results, equivalent monolithic system can be classified into two categories. Strong connection have extremely small deformation contribution of joint and much larger deformation contribution was shown in flexural behavior of beam. The other type of beam-column connection is ductile connection which allows the larger deformation in joint area compared with strong connection.