• Title/Summary/Keyword: Fire-Fighting Safety

검색결과 224건 처리시간 0.025초

Case Study the Awareness of Safety Education and School Safety of one Technical high school Students (일개 공업계 고등학교 학생의 안전교육과 학교안전 인식에 관한 사례 연구)

  • Hong, Young Ho
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제17권7호
    • /
    • pp.536-542
    • /
    • 2016
  • This case study was carried out for the purpose of surveying the awareness of safety and safety education among students in a technical high school, in order to provide the basic data for the effective education of technical high school students' safety management consciousness. The study was carried out using a questionnaire survey for which the respondents were 455 students. The results of the questionnaire were subjected to statistical processing, such as frequency analysis using SPSS for Windows version 19.0. The reliability of the questionnaire in this study is Cronbach' = 0.871~0.882. According to the survey results, the students think that the contents of the school safety education would not be of interest to them and that safety education in school would help their school life, but not be useful for their daily life.

Analyses on Related Factors with Fire Damage in Korea (한국에서의 화재 피해 관련요인 분석)

  • Chang, Eunmi;Kang, Byungki;Park, Kyeong
    • Journal of the Korean Geographical Society
    • /
    • 제50권3호
    • /
    • pp.355-373
    • /
    • 2015
  • In this study the factors of fire damage are analyzed through previous research reviews. Local environmental factors as well as those factors attributed to fire damage (number of fire events, number of injured, number of death, economic loss) were selected to compose mutual relationship model. In order to verify this relationship model, official statistics concerning fire damage were collected from 228 local governments and compared with results from previous research. As a result of this comparison four dependent variables and 22 independent variables that affect fire damage were analyzed. Independent variables are divided into human vulnerability factors, physical vulnerability factors, economic vulnerability factors, mitigating factors and local characteristics. To analyze a relationship between selected dependent variables and independent variables, we applied a semi-logarithm model and performed regression analysis. Among the 22 independent variables, the number of the weak to disaster, social welfare service workers, workers in manufacturing industry, and the number of workers in restaurants and bars per 10,000 people show the significant correlation with the number of fire incidence. The number of death from fire is significantly related to two variables which are the number of social welfare service workers per 10,000 and the ratio of commercial area. Damage cost is significantly dependent on the property taxes per 10,000 people. These factors were included in the research model as vulnerability factors (human, physical, economic) and mitigating factors and local characteristics, and the validity of research model was verified. The result could contribute to fire-fighting resource allocation in Korea or they can be utilized in establishing fire prevention policy, which will enhance the national level of fire safety.

  • PDF

Safety and antifatigue effect of Korean Red Ginseng: a randomized, double-blind, and placebo-controlled clinical trial

  • Zhang, Li;Chen, Xiaoyun;Cheng, Yanqi;Chen, Qilong;Tan, Hongsheng;Son, Dongwook;Chang, Dongpill;Bian, Zhaoxiang;Fang, Hong;Xu, Hongxi
    • Journal of Ginseng Research
    • /
    • 제43권4호
    • /
    • pp.676-683
    • /
    • 2019
  • Background: Korean Red Ginseng (KRG) is widely used for strengthening the immune system and fighting fatigue, especially in people with deficiency syndrome. However, there is concern that the long-term application or a high dose of KRG can cause "fireness" (上火 in Chinese) because of its "dryness" (燥性 in Chinese). The aim of this study was to assess the safety and efficacy of a 4-week treatment with KRG in participants with deficiency syndrome. Methods: This was a 4-week, randomized, double-blind, placebo-controlled clinical trial. A total of 180 Chinese participants were randomly allocated to three groups: placebo control group, participants were given a placebo, 3.6 g/d; KRG 1.8 g and 3.6 g groups. The primary outcomes were the changes in fireness and safety evaluation (adverse events, laboratory tests, and electrocardiogram). The secondary outcomes were the efficacy of KRG on fatigue, which include the following: traditional Chinese medicine (TCM) symptom scale and fatigue self-assessment scale. Results: Of the 180 patients, 174 completed the full study. After 4 weeks of KRG treatment, the Fire-heat symptoms score including Excess fire-heat score and Deficient fire-heat score showed no significant change as compared with placebo treatment, and no clinically significant changes in any safety parameter were observed. Based on the TCM syndrome score and fatigue self-assessment score, TCM symptoms and fatigue were greatly improved after treatment with KRG, which showed a dose- and time-dependent effect. The total effective rate was also significantly increased in the KRG groups. Conclusion: Our study revealed that KRG has a potent antifatigue effect without significant adverse effects in people with deficiency syndrome. Although a larger sample size and longer treatment may be required for a more definite conclusion, this clinical trial is the first to disprove the common conception of "fireness" related to KRG.

Study on the Risk of Flammability & Combustion of Liquid Mixtures such as Alcohols (알코올류 등의 액체 혼합물에 대한 인화 및 연소 위험성에 관한 연구)

  • Koh, Jae-Sun
    • Journal of the Society of Disaster Information
    • /
    • 제15권4호
    • /
    • pp.634-647
    • /
    • 2019
  • Purpose: Currently, many chemicals are used in industrial and real life, and many substances are used in the form of a single substance, but most of them are used in the form of a mixture, and there is a need for a criterion for judging the danger of these substances. Method: Therefore, this study aims to confirm the risk criteria of the mixture through experimental studies on flammable mixtures in order to secure the effectiveness of the details of the existing Dangerous Goods Safety Management Act angerous Goods Judgment Criteria and to ensure the reliability and reproducibility of the dangerous goods judgment. Result: Experimental results show that alcohol flash point is mixed with water, which is a non-flammable liquid. Similar flash point trends occurred around 60% on an alcohol basis. In addition, in the case of flammable-combustible mixtures, there was little change in flash point if the flash point difference of the two materials was not large, and if the flash point difference of the two materials was low, the flash point tended to increase with the increase of the high flash point material. Conclusion: In the future, the test results may provide reference data on the experimental criteria for the flammable liquids that are cracked at the fire site.

A Study on Identifying Problems by the Comparative Analysis of High-Rise Apartment Evacuation Design Codes (고층 아파트 피난설계기준 비교분석을 통한 문제점 도출 연구)

  • Hwang, Eun-Kyoung;Seo, Dong-Goo
    • Fire Science and Engineering
    • /
    • 제31권6호
    • /
    • pp.47-52
    • /
    • 2017
  • The recent tragic outbreak of fire at the Grenfell Tower in the United Kingdom compels all branches of government to reexamine and reassess the safety measures against fires in high-rise buildings from a broad perspective. Accordingly, this study examined what problems stem from the current evacuation codes by comparative analysis of the high-rise apartment evacuation codes that range over various individual laws before introducing a new evacuation code. The outcome of this study can be utilized as basic data for amending the existing evacuation codes for high-rise buildings. The codes related to high-rise building evacuation include the Building Act, the Housing Act, the Skyscraper Disaster Management Act, and the Fire-Fighting System Act. Some local governments have also drawn up their own codes and put them into practice. Comparative analysis of the major evacuation codes has helped identify a variety of problems, such as different codes being applied to each individual law and ordinance, the use of additional codes other than the provisions of laws and ordinances, and the in effectiveness of evacuation codes. Most of these problems occur when diverse codes are applied to a single building, which means that cooperation among the relevant ministries is urgently needed to improve the related codes in the future.

Development of Accident Response Information Sheets for Hydrogen Fluoride (불화수소에 대한 사고대응 정보시트 개발)

  • Yoon, Young Sam;Park, Yeon Shin;Kim, Ki Joon;Cho, Mun Sik;Hwang, Dong Gun;Yoon, Jun heon;Choi, Kyung Hee
    • Korean Journal of Hazardous Materials
    • /
    • 제2권1호
    • /
    • pp.18-26
    • /
    • 2014
  • We analyzed the demand of competent authorities requiring adequate technical information for initial investigation of chemical accidents. Reflecting technical reports on chemical accident response by environmental agencies in the U.S. and Canada, we presented information on environmental diffusion and toxic effects available for the first chemical accident response. Hydrogen fluoride may have the risk potential to corrode metals and cause serious burns and eye damages. In case of inhalation or intake, it could have severe health effects. The substance itself is inflammable, but once heated, it decomposes producing corrosive and toxic fume. In case of contact with water, it can produce toxic, corrosive, flammable or explosive gases and its solution, a strong acid, may react fiercely with a base. In case of hydrogen fluoride leak, the preventive measures are to decrease steam generation in exposed sites, prevent the transfer of vapor cloud and promptly respond using inflammable substances including calcium carbonate, sodium bicarbonate, ground limestone, dried soil, dry sand, vermiculite, fly ash and powder cement. The method for fire fighting is to suppress fire with manless hose stanchions or monitor nozzles by wearing the whole body protective clothing equipped with over-pressure self-contained breathing apparatus from distance. In case of transport accident accompanied with fire, evacuation distance is 1,600m radius. In cae of fire, fire suppression needs to be performed using dry chemicals, CO2, water spray, water fog, and alcohol-resistance foam, etc. The major symptoms by exposure route are dyspnoea, bronchitis, chemical pneumonia and pulmonary edema for respiration, skin laceration, dermatitis, burn, frostbite and erythema for eyes, and nausea, diarrhea, stomachache, and tissue destruction for digestive organs. In atmosphere, its persistency is low, and its bioaccumulation in aquatic organism is also low.

A Study on the Improvement of Port State Control in Korea (우리나라의 항만국통제 제도의 개선에 관한 연구)

  • 박병곤;정재용;박진수
    • Journal of the Korean Institute of Navigation
    • /
    • 제23권4호
    • /
    • pp.43-61
    • /
    • 1999
  • To ensure ship's safety and preserve the marine environment from ship, IMO(International Maritime Organization) has been making much efforts. Nevertheless there are still many possibilities threatening ship's safety and the marine environment. Many vessels navigate at sea in lack of standard required by the International Convention relevant to ship's safety and the protection of marine environment. Even though the administration is responsible for perfect and continuous control for safety of ship, it cannot has jurisdiction over ships hoist its flag reasonably at all times. So the Port State has strengthened the Port State Control(PSC) activity as one step of eliminating sub-standard vessels. In the light of the fact that mentioned above, this study deals with PSC activity in Korea and port of Pusan. Total 582 ships, inspected in port of Pusan from 1st January 1998 to 30th September 1999, were analyzed in various aspect and extracted results as follows : \circled1 The inspection rate in Korea was much lower than the other states taking part in Tokyo MOU, \circled2 For flag state, the ships belong to flag of convenience(FOC) had much more deficiencies than non-convenience flag ships, \circled3 For ship type, 39 number of general dry cargo ship were detained at Pusan with serious deficiencies, \circled4 For deficiency item, the items such as life saving appliances, safety in general, navigation, load lines and fire-fighting appliances were occupied over 71.7% of total number of deficiencies, \circled5 In Asia-Pacific region, Korea was one of flags with detention percentages exceeding 3-year(1996~1998) rolling average detention percentage. Average detention rate of Korean vessels was 6.73% which was over 0.24% of average detention rate(6.49%) in Asia-Pacific region. These results may reflect to improve the performance of PSC inspection for foreign vessels and are useful for preparing PSC inspection for ocean-going ships registered in Korea.

  • PDF

The Proposition of Domestic Sprinklers Installation Standard and the Fire Services Act (국내 스프링클러 설치기준과 소방관련 법에 관한 고찰)

  • Kim, Yong-Moon;Lee, Young-Jai
    • Journal of Korean Society of Disaster and Security
    • /
    • 제7권2호
    • /
    • pp.17-24
    • /
    • 2014
  • Recently, many accidents occur frequently because sprinklers aren't installed or don't work right when there are outbreak of fire in houses and aggregate buildings. Therefore, they can result in damage for humans and loss of property. Sprinklers are the most appropriate which can extinguish buildings' fire in the initial stages. Through lack of legal system, in domestic cases, sprinklers cannot operate their inherent performance. Domestic standard simply classifies installation objects according to types of business and forms of buildings, also divides into uses and floors of buildings. Especially it only regulates that sprinklers must be installed every floors in particular fire buildings that have more than eleven floors. While it doesn't need to install sprinklers below ten floors, so we are threatened the safety. In this study, we derived causes and implications by analyzing concepts of sprinklers facilities, installation standards in domestic and foreign legal system, and recent cases that expanded damages in fire accidents because of weak point of installation and control standards. In domestic cases, as a result, government has to provide an institutional strategy and law that regulate duty to install sprinklers to all aggregate buildings regardless of floors in terms of new buildings. Also, if someone who has existing buildings wanted to install them, government would guarantee subsidy to encourage installation. In addition, government supervises fire-fighting activities when there are fire by compensating standards about regular inspection by a qualified technician, operation and maintenance of sprinklers as well as reinforcement of administrative criteria.

The study on application of automatic monitor system for initial fire suppression in double-deck tunnel (대심도 복층터널 초기화재 진압을 위한 자동모니터 소화설비의 적용성 연구)

  • Yoo, Yong-Ho;Park, Sang-Heon;Han, Sang-Ju;Park, Jin-Ouk
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • 제18권5호
    • /
    • pp.419-429
    • /
    • 2016
  • In a bid to avoid the economic loss resulting from traffic jam in urban area, a deep underground road at 40 m depth has been considered and the first class disaster prevention facilities shall be applied according to domestic guideline. Automatic-monitoring fire extinguishing system designed to use for fire fighting has been widely applied at home and abroad. Recently development and commercialization through theoretical and experimental research to apply to road/railroad sector have been underway. Based on such performance of automatic fire extinguishing system, technical/economic analysis of existing water spray systems was conducted and as a result, it has demonstrated the superiority in terms of fire suppression as well as in cost efficiency. Then to commercialize this system, more diverse studies that will incorporate the characteristics of domestic tunnels are needed and should the system be promoted through institutional improvement, it's expected to become one of the advanced nations with own original technology in a life safety system industry throughout the world.

Analysis of Evacuation Time According to Variation of Evacuation Stairs' Width in Large-Scale Goshiwons (대규모 고시원의 피난계단 폭의 변화에 따른 피난소요시간 분석)

  • Oh, Su-cheol;Kong, Ha-Sung
    • The Journal of the Convergence on Culture Technology
    • /
    • 제8권5호
    • /
    • pp.641-651
    • /
    • 2022
  • This research compares and analyzes evacuation time depending on the change in stair width in case of fire at Goshiwons. For this, a simulation has been conducted based on possible evacuation time according to the calculation method for the number of people admittable to a specific target for fire fighting equipped with accommodation. Currently, Gosiwon, which is classified as an accommodation facility (a total floor area of 500 m2 or more), uses blind spots prescribed by the Fire Services Act, Building Act, and Parking Act to build a high-rise building on a small area of land, and most Gosiwon is transformed into a modified accommodation. This is in line with the owner's operating profit, so it is expected to show a continuous increase. Securing the golden time of Gosiwon evacuation time is the last bastion of Gosiwon residents who belong to the economically disadvantaged in our society, and we hope this study will serve as a starting point for discussions on revising related laws and regulations to establish a social safety net As a result of the evacuation simulation analysis, the evacuation time was the least when the width of the group and the evacuation stairs were expanded to 200cm, and the evacuation time of the existing building was reduced by up to 166.3 seconds by comparing 648.4 seconds and scenario 6. This analysis can be meaningful, in that the width of the evacuation stairs revision of related laws and regulations for the safety of multiplex available premises.