• Title/Summary/Keyword: Fire-Damaged Concrete

Search Result 115, Processing Time 0.028 seconds

A Safety Analysis on the Fire Endurance of Concrete Structures (화재에 대한 콘크리트구조물의 안전성 해석)

  • Bang, Myung-Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.61-66
    • /
    • 2011
  • Fire disasters have frequently happened in concrete structures, which resulted in severe structural damages and unsafety. In this case, the method which had evaluated the safety of damaged structures was often unaccepted from most of stakeholders and engineers. The objective of this study is to develope the procedure and method to be able to determine the safety. Numerical simulation was applied to produce the maximum temperature and temperature distribution. Nextly, temperature propagation analysis was performed to plot temperature gradients at each depth and location. The material strength curve versus temperature was applied to determine the safety of concrete structures damaged by fire. The maximum temperature should be calibrated considering real fire records ; magnitude, intensity, situation etc. The results shows that the selected procedure and method was applicable and practical.

Experimental study on cyclically-damaged steel-concrete composite joints subjected to fire

  • Ye, Zhongnan;Jiang, Shouchao;Heidarpour, Amin;Li, Yingchao;Li, Guoqiang
    • Steel and Composite Structures
    • /
    • v.30 no.4
    • /
    • pp.351-364
    • /
    • 2019
  • Earthquake and fire are both severe disasters for building structures. Since earthquake-induced damage will weaken the structure and reduce its fire endurance, it is important to investigate the behavior of structure subjected to post-earthquake fire. In this paper, steel-concrete composite beam-to-column joints were tested under fire with pre-damage caused by cyclic loads. Beforehand, three control specimens with no pre-damage were tested to capture the static, cyclic and fire-resistant performance of intact joints. Experimental data including strain, deflection and temperature recorded at several points are presented and analyzed to quantify the influence of cyclic damage on fire resistance. It is indicated that the fire endurance of damaged joints decreased with the increase of damage level, mainly due to faster heating-up rate after cyclic damage. However, cracks induced by cyclic loading in concrete are found to mitigate the concrete spalling at elevated temperatures. Moreover, the relationship between fire resistance and damage degree is revealed from experimental results, which can be applied in fire safety design and is worthwhile for further research.

Analytical Estimation of Internal Temperature of RC Beam under Fire (화재시 철근 콘크리트 보 내부 온도의 해석적 추정)

  • Lee Eun-ju;Shin Mi-kyung;Kang Ji-yeon;Shin Yeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.05a
    • /
    • pp.548-551
    • /
    • 2004
  • The main purpose of this study is to estimate the internal temperature of RC beam under fire. For this purpose, the finite difference method was used. In the previous studies, the structural behavior of fire damaged RC beams was investigated through experiments. The result was concluded that The high temperature affects the properties of concrete such as the elastic modulus, the compressive strength. The internal temperature Estimation of the concrete is helpful for understanding the structural behavior of fire damaged RC beams. Especially, high strength concrete has more spalling than normal strength one. So, this study is performed analysis of internal temperature of RC beam considering spalling.

  • PDF

Investigating the Effect of Prior Damage on the Post-earthquake Fire Resistance of Reinforced Concrete Portal Frames

  • Ronagh, Hamid Reza;Behnam, Behrouz
    • International Journal of Concrete Structures and Materials
    • /
    • v.6 no.4
    • /
    • pp.209-220
    • /
    • 2012
  • Post-earthquake fire (PEF) can lead to a rapid collapse of buildings that have been partially damaged as a result of a prior earthquake. Almost all standards and codes for the design of structures against earthquake ignore the risk of PEF, and thus buildings designed using those codes could be too weak when subjected to a fire after an earthquake. An investigation based on sequential analysis inspired by FEMA356 is performed here on the immediate occupancy (IO), life safety (LS) and collapse prevention (CP) performance levels of two portal frames, after they are pushed to arrive at a certain level of displacement corresponding to the mentioned performance level. This investigation is followed by a fire analysis of the damaged frames, examining the time taken for the damaged frames to collapse. As a point of reference, a fire analysis is also performed for undamaged frames and before the occurrence of earthquake. The results indicate that while there is minor difference between the fire resistances of the fire-alone situation and the frames pushed to the IO level of performance, a notable difference is observed between the fire-alone analysis and the frames pushed to arrive at LS and CP levels of performance and exposed to PEF. The results also show that exposing only the beams to fire results in a higher decline of the fire resistance, compared to exposing only the columns to fire. Furthermore, the results show that the frames pushed to arrive at LS and CP levels of performance collapse in a global collapse mode laterally, whereas at the IO level of performance and fire-alone situation, the collapse mechanism is mostly local through the collapse of beams. Whilst the investigation is conducted for a certain class of portal frames, the results confirm the need for the incorporation of PEF into the process of analysis and design, and provide some quantitative measures on the level of associated effects.

Utilization of Immersion-Drying Method for Measuring Damage Depth of Fire-Damaged High-Strength Concrete (화재로 손상된 고강도 콘크리트의 손상 깊이 측정을 위한 수중침지 건조방법의 활용)

  • Kim, Jong;Lim Gun-Su;Beak, Seung-Bok;Han, Min-Cheol
    • Journal of the Korea Institute of Building Construction
    • /
    • v.24 no.3
    • /
    • pp.297-308
    • /
    • 2024
  • This study presents a novel approach for evaluating fire-induced damage depth in concrete. The methodology leverages the principle that exposure to high temperatures causes internal expansion within concrete, leading to increased voids and microcracks in the damaged zones. This heightened porosity results in greater absorption rates compared to undamaged areas. By immersing fire-damaged concrete samples in water and subsequently monitoring the drying process, the depth of damage can be assessed. Differences in drying rates and color variations between damaged and undamaged areas serve as visual indicators for determining the extent of the damage. Experimental results from this water immersion method revealed damage depths of 38.7mm and 37.5mm for two different concrete mixtures. These measurements notably surpass the damage depths estimated using traditional phenolphthalein-based methods. This discrepancy suggests that utilizing the absorption rate principle, which is directly linked to the physical changes caused by thermal expansion, offers a more accurate and sensitive assessment of fire damage depth compared to methods relying solely on the presence of Portlandite for colorimetric indication.

The Maintenance Methods of Concrete Deterioration caused by Fire Attack (화재피해를 입은 콘크리트 구조물의 유지관리방안)

  • Kwon, Young-Jin;Yoon, Ung-Gi;Koo, In-Hyeok
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2015.05a
    • /
    • pp.236-237
    • /
    • 2015
  • Concrete is the one of the most widely used in every country as a structural materials. On the other hand, a lot of fire incident has been occurred all over the world. But maintenance methods such as inspection and diagnostic methods, design methods, quality control methods for the purpose of improving the performance of concrete structures damaged by fire has made in its own way. Therefore, the purpose of this proposal of new working item is is to ensure the safety of the concrete structures damaged by fire in the field of assessment of damage, design, repair methods and so on through the International Organization for Standardization.

  • PDF

Practical Predictive Formulas for Residual Strengths of Fire-Damaged Normal Strength Reinforced Concrete Square Columns (화해를 입은 보통강도 철근콘크리트 정방형 기둥의 실용 잔존내력식)

  • Lee, Cha-Don;Lee, Seung-Whan;Lee, Chang-Eun
    • Journal of the Korea Concrete Institute
    • /
    • v.18 no.1 s.91
    • /
    • pp.3-12
    • /
    • 2006
  • The behavior of concrete structures subject to fire is complex, depending on many factors. The factors usually considered in research include the level and endurance of temperatures in concrete and reinforcing bars, the mechanical properties of the steel and concrete, moisture contents, cover thickness, existence of eccentricity, and member geometry among others. Although there are a few sophisticated numerical models which can trace the effects of these important parameters on the residual capacity of reinforced concrete columns damaged by fire, practical predictive formulas are in need for rapid yet reasonable assessment in practice. The practical formulas are developed in this study for fire-damaged normal strength reinforced concrete square columns, which can approximate the predictions of those sophisticated numerical models with ease in use. The formulas take into account the effects of exposure time to fire, concrete strength, reinforcement ratio and sectional area. The developed formulas are seen to correlate with the predictions of numerical model in a reasonable agreement. Some examples are also presented in determining the residual strength, safety and additionally needed strengths for a fire-damaged reinforced concrete column.

Residual strength of spalled high-performance concrete members subjected to fire (화재시 고강도 콘크리트 부재의 폭렬성상에 따른 잔존강도)

  • Choi, Eun-Gyu;Shin, Yeong-Soo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2008.11a
    • /
    • pp.941-944
    • /
    • 2008
  • This study is aimed to investigate the residual strength of fire damaged high-performance concrete flexural and compressive members. The compressive strength of specimens is 55MPa and the main parameter for comparison is the exposure time to fire. In case of beams, the cover thickness made the differences in spalled section area, residual strength and serviceability. The exposure time to fire did not affect on the spalled section area in case of compressive members without loading. However, the residual strength and stiffness was reduced by the time exposed to fire. This study can be used to estimate the performance of fire damaged high-strength concrete structural members for reusing and to give the information for repairing and strengthening.

  • PDF

Flexural performance of fire damaged and rehabilitated two span reinforced concrete slabs and beams

  • Yu, Jiang-Tao;Liu, Yuan;Lu, Zhou-Dao;Xiang, Kai
    • Structural Engineering and Mechanics
    • /
    • v.42 no.6
    • /
    • pp.799-813
    • /
    • 2012
  • Five two-span reinforced concrete (RC) slabs and seven two-span RC beams were tested under the ISO 834 standard fire with different durations. CFRP strengthening was then applied to some of the specimens after the damaged concrete was removed from the specimens and replaced with polymer mortar. All the specimens were loaded to failure to investigate the influence of fire-damage and the effectiveness of strengthening methods. Test results indicated that the flexural capacities of specimens decrease with the fire duration increases. Moreover, fire exposure had more significant effect on the flexural rigidity than on the bearing capacity of the specimens. After rehabilitation, the bearing capacities of specimens reached or even exceeded that of the reference RC specimen, and the strengthening methods seemed to have limited effect on flexural rigidity recovery. From the analysis of moment redistribution of tested beams, elevated temperature is found having different impacts on sagging moment region and hogging moment region. The damage of RC continuous member is definitely a comprehensive response of different regions.