• 제목/요약/키워드: Fire water

검색결과 1,093건 처리시간 0.028초

Numerical analysis on the rapid fire suppression using a water mist nozzle in a fire compartment with a door opening

  • Lee, Jaiho
    • Nuclear Engineering and Technology
    • /
    • 제51권2호
    • /
    • pp.410-423
    • /
    • 2019
  • Fire suppression using a water mist nozzle directly above an n-Heptane pool in a fire compartment with a door opening was numerically investigated using the Fire Dynamics Simulator (FDS) for the purpose of application in nuclear power plants. Input parameters for the numerical simulation were determined by experimental measurements. Water mist was activated 10 s after the fire began. The sensitivity analysis was conducted for three input parameters: total number of cubic cells of 6032-2,926,400, droplets per second of 1000-500,000, and extinguishing coefficient of 0-100. In a new simple calibration method of this study, the extinguishing coefficient yielding the fire suppression time closest to that measured by experiments was found for use as the FDS simulation input value. When the water mist jet flow made contact with the developed fire, the heat release rate instantaneously increased, and then rapidly decreased. This phenomenon occurred with a displacement of the flame near the liquid fuel pool. Changing the configuration of the door opening with different aspect ratios and opening ratios had impact on the maximum value of the heat release rate due to the flame displacement.

Extinguishment of Liquid Fuel Fire by Water Mist Containing Additives

  • Park, Jae-Man;Won, Jung-Il;Shin, Chang-Sub
    • International Journal of Safety
    • /
    • 제4권2호
    • /
    • pp.24-29
    • /
    • 2005
  • An experimental study was presented for extinguishing characteristics of liquid fuel fire by water mist($Dv_{0.99}{\leq}200{\mu}m$) containing potassium acetate and sodium acetate trihydrate. To evaluate the extinguishing performance of water mist containing additives, the evaporation characteristics of a water droplet on a heated surface was examined. The evaporation process was recorded by a charge-coupled-device camera. Also, small-scale extinguishing tests were conducted for n-heptane pool fire in ventilated space. During the experiments, flame temperatures were measured, and concentrations of oxygen and carbon monoxide were analyzed by a combustion gas analyzer. The average evaporation rate of water droplet containing additives was lower than that of pure water at a given surface temperature and decreased with the concentration increase due to the precipitation of salt in the liquid-film and change of surface tension. In case of using additives, the fire extinguishing times was shorter than that of pure water at a given discharge pressure and it was because the momentum of a water droplet containing additives was increased. And also dissociated metal atoms, potassium or sodium, were reacted as a scavenger of the major radical species OH, H which were generated for combustion process. Moreover, at a high pressure of 4 MPa, the fire was extinguished through blowing effect as well as primary extinguishing mechanisms.

태양광 발전설비가 설치된 건물의 진화 시 주수에 의한 감전의 위험성에 관한 연구 (A Study on the Risk of Electric Shock from the Sprayed Water for Fire Suppression of the PV Installed Building)

  • 김진선;권성필
    • 한국화재소방학회논문지
    • /
    • 제28권6호
    • /
    • pp.47-51
    • /
    • 2014
  • 본 연구에서는 태양광 발전설비가 설치되어 있는 건물에서 화재가 발생할 경우 분사되는 물을 통해 전류가 흐를 가능성 및 감전의 위험성에 대해 고찰하였다. 분사되는 물을 수학적 모델을 통하여 해석 하였고, 물 전도도 측정을 위한 물분사 시스템을 제작하여 유속에 따른 물 저항값을 측정하여 수치적으로 예상한 값과 비교하였다. 실험과 수치계산의 결과로 태양광 발전설비 화재 시 고려되어야 할 사항들을 정의할 수 있게 되었다.

EVALUATION OF AN ACCIDENT MANAGEMENT STRATEGY OF EMERGENCY WATER INJECTION USING FIRE ENGINES IN A TYPICAL PRESSURIZED WATER REACTOR

  • PARK, SOO-YONG;AHN, KWANG-IL
    • Nuclear Engineering and Technology
    • /
    • 제47권6호
    • /
    • pp.719-728
    • /
    • 2015
  • Following the Fukushima accident, a special safety inspection was conducted in Korea. The inspection results show that Korean nuclear power plants have no imminent risk for expected maximum potential earthquake or coastal flooding. However long- and short-term safety improvements do need to be implemented. One of the measures to increase the mitigation capability during a prolonged station blackout (SBO) accident is installing injection flow paths to provide emergency cooling water of external sources using fire engines to the steam generators or reactor cooling systems. This paper illustrates an evaluation of the effectiveness of external cooling water injection strategies using fire trucks during a potential extended SBO accident in a 1,000 MWe pressurized water reactor. With regard to the effectiveness of external cooling water injection strategies using fire engines, the strategies are judged to be very feasible for a long-term SBO, but are not likely to be effective for a short-term SBO.

소화용 스프링클러 헤드의 살수분포 및 수적 특성에 대한 연구 (The Study on Characteristics of Water Spray and Droplet from Fire Sprinkler Head)

  • 추병길;최종욱;차경세
    • 한국안전학회지
    • /
    • 제16권2호
    • /
    • pp.13-21
    • /
    • 2001
  • The effect of water spray for the fire sprinkler depends on droples distribution over maximum possible floor area. The present study are carried out for the characteristics of water spray and droplets experimentally and numerically km two fire sprinkler heads which are CHM head and CHl heal CHl head is self-production and CHl head is widely used up to date. As the result of using CHM head, water spray and droplets are distributed over large area because CHM head has smooth surface and non-flamed shape. When the pressure of fire sprinkler head is low, SMD(sauter mean diameter) is large and when the pressure of fire sprinkler head is high, SMD is small.

  • PDF

선박용 미분무수 소화설비의 성능평가연구 (A Study on the performance test of Water mist system as a fire extinguish system for Ships)

  • 김성윤;안병호;김동석;김유택
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2006년도 전기학술대회논문집
    • /
    • pp.155-156
    • /
    • 2006
  • Developed and conducted a performance test of the Water mist system that is satisfied with the requirement of a fire test requiring Class 3 Engine Mock-up exceeding net volume $3,000m^3$ as per IMO's MSC/Circ. 668 Appendix B(Test method for fire testing equivalent water-based fire-extinguishing systems for machinery spaces of category A and cargo pump rooms).Even though fuel atomizing was continued for 15 sec. after stopping of the system according to the test method relating to the atomizing fire type, no fire was reignited. This result shows the excellence of the system. There was no damage to the contents of the system after the test.

  • PDF

Application of reinforcement learning to fire suppression system of an autonomous ship in irregular waves

  • Lee, Eun-Joo;Ruy, Won-Sun;Seo, Jeonghwa
    • International Journal of Naval Architecture and Ocean Engineering
    • /
    • 제12권1호
    • /
    • pp.910-917
    • /
    • 2020
  • In fire suppression, continuous delivery of water or foam to the fire source is essential. The present study concerns fire suppression in a ship under sea condition, by introducing reinforcement learning technique to aiming of fire extinguishing nozzle, which works in a ship compartment with six degrees of freedom movement by irregular waves. The physical modeling of the water jet and compartment motion was provided using Unity 3D engine. In the reinforcement learning, the change of the nozzle angle during the scenario was set as the action, while the reward is proportional to the ratio of the water particle delivered to the fire source area. The optimal control of nozzle aiming for continuous delivery of water jet could be derived. Various algorithms of reinforcement learning were tested to select the optimal one, the proximal policy optimization.

미세물분무 작동에 대한 FDS 예측 성능 평가 (Estimation of FDS Prediction Performance on the Operation of Water-Mist)

  • 고권현
    • 한국산학기술학회논문지
    • /
    • 제15권8호
    • /
    • pp.4809-4814
    • /
    • 2014
  • 본 논문은 미세물분무 작동에 따른 화재 거동 및 제압 특성을 예측하는 데 있어서 FDS(Fire Dynamic Simulator)의 예측 성능을 평가하는 것을 목적으로 한다. 미세물분무의 초기액적분포 입력을 위해 Rosin-Rammler /log-normal 분포를 사용하였으며 모델 상수의 영향을 살펴보았다. 또한 미세물분무의 분사압력에 따른 화재 제압특성을 이전의 실험 결과와 비교함으로써 해석 모델을 검증하고 열유동 특성 및 가스 농도 변화를 분석하였다. 결과로부터 동일한 평균입경을 갖는 미세물분무도 액적분포의 특성에 따라 하부 위치에서의 액적 크기 및 속도에 큰 영향을 받고 있음을 확인할 수 있었다. 분무특성에 대한 실험결과와의 비교를 통해 적절한 초기입경분포를 결정하였으며 이를 이용하여 화재 시뮬레이션을 진행하였다. FDS 화재 시뮬레이션 결과는 온도의 변화 및 화재 제압 특성에 대하여 실험 결과와 좋은 일치를 보여주었다. 또한 미세물분무의 작동압력에 따른 열유동장 변화, 가스상 농도 변화의 예측에 있어 유용한 데이터를 제공할 수 있음을 확인하였다.

Interpretation of the Five Viscera's Ascending Kidney-Water and Descending Heart-Yang

  • Bang, Jung-Kyun
    • 대한한의학회지
    • /
    • 제26권4호
    • /
    • pp.162-167
    • /
    • 2005
  • According to the principle of ascending water and descending fire, water has the property of wetting downward, which is the opposite of fire, which has the property of blazing upward. Thus, they work differently according to their innate properties. Nature and the human body maintain harmony through the interaction of ascending water and descending fire. When applied to the human body, the heart and kidney are the center of this principle. In other words, the heart above is the fire and the kidney downward is water. When the heart-fire harmonizes downward, the kidney becomes warm, enabling genuine vital functions to be active. When the kidney yin moves upward, the heart receives the nourishing yin to harmonize nutrients and blood. Thereby, physiological functions become normal throughout the blood meridians. However, in the ascending kidneywater and descending heart-yang of the heart and the kidney, the liver and lung are the major functional organs. In other words, the liver through the dispersing and raising yang functions moves water, which is the vital essence of the kidney, upward. And the lung, through the astriction?clearing of the lung and descending Qi?dispersing functions, moves the heart-fire downward. These functions are deeply related with changing seasons; thus, these functions can be explained with the ascending kidney-water and descending heart-yang of the five viscera.

  • PDF