• 제목/요약/키워드: Fire wall

검색결과 355건 처리시간 0.255초

건물내 화재에 의한 연소가스 거동 예측에 관한 연구 (A Study on the Prediction of Combustion Gas Behavior Induced by Fire in a Building)

  • 박희용;박경우
    • 설비공학논문집
    • /
    • 제6권3호
    • /
    • pp.267-281
    • /
    • 1994
  • The Combustion gas behavior induced by fire in a building is numerically investigated. The typical building for this analysis is partially divided by a vertical baffle projecting from the ceiling. The solution procedure includes the low Reynolds number ${\kappa}-{\varepsilon}$ model for the turbulent flow and the discrete ordinates method is used for the calculation of radiative heat transfer equation. The effects of the location and size of fire source and baffle length on velocity and temperature distributions, species mass fraction and flame location are analyzed. As the results of this study, it is found that the case when the fire source is located at the vertical wall is more dangerous than at the bottom wall in view of the combustion products and flame location. It is also found that the radiation effect cannot be neglected in analyzing the building in fire.

  • PDF

고열을 받는 방화문의 비정상 열전달 (Unsteady Heat Transfer of Fire Door Exposed to High Temperature)

  • 박일규;장동식;이연원;권오현;도덕희
    • 한국안전학회지
    • /
    • 제15권1호
    • /
    • pp.59-65
    • /
    • 2000
  • The purpose of this study is to investigate the details of unsteady heat transfer in a heated fire door. This investigation is carried out numerically for two dimensional fire door which is composed of normal plasterboard and mild steel including air layer or heat shield. It is shown from the results that the recirculation occurs at the inner part of fire wall due to gravity force by temperature difference. The case I gives better adiabatic effect than the case II because temperature around the fire wall reachs at $230.96^{\circ}C$ in the case I and reachs at $450.37^{\circ}C$ in the case II.

  • PDF

벽체 종류에 따른 무선화재감지기의 응답특성에 관한 연구 (A Study on the Response Characteristics of the Wireless Fire Detector Depending on the Wall Types)

  • 사공성호;김시국;이춘하;김형권
    • 한국화재소방학회논문지
    • /
    • 제25권4호
    • /
    • pp.82-88
    • /
    • 2011
  • 본 논문에서는 무선화재감지기의 효용성 및 신뢰성을 확인하고자, 현재 가장 많이 상용화되어 있는 2.4 GHz의 주파수를 사용하는 무선모듈을 이용하여, 건물 내에서 무선통신 환경에 영향을 줄 수 있는 대표적인 장애물의 종류인 벽체를 시료로 하여 무선신호의 투과파 측정실험을 실시하였다. 실험결과 벽체 종류에 따라 무선신호의 응답특성에 차이가 나타나는 것을 확인할 수 있었다.

축소 구획실에서 화원과 측벽의 거리에 따른 화재특성 변화 (Changes in Fire Characteristics according to the Distance Between the Fire Source and Sidewall in a Reduced-Scale Compartment)

  • 윤홍석;황철홍
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.50-59
    • /
    • 2019
  • 과환기 화재조건에서 화원과 측벽의 거리에 따른 화재특성에 관한 실험 및 수치해석 연구가 수행되었다. 1/3 축소된 ISO 9705 화재실이 제작되었으며, Spruce wood crib이 연료로 사용되었다. 구획 내부의 현상 이해를 위하여 Fire Dynamics Simulator (FDS)를 활용한 시뮬레이션이 수행되었다. 개방된 공간 화재에 비해 구획실 화재는 벽면의 열 피드백 효과로 인하여 질량 감소율과 열발생률이 증가됨이 확인되었다. 측벽과 화원의 거리가 감소됨에 따라 화염으로의 공기 유입 제한에도 불구하고 주요 화재특성인 최대 질량 감소율, 열발생률, 화재 성장률, 온도 및 열유속이 증가되었다. 특히 측벽과 화원이 접촉되었을 때 이들 물리량의 가장 큰 변화가 확인되었다. 추가로 화원과 측벽의 거리에 따른 구획 내부의 유동구조의 변화로 인하여 온도의 수직분포에 상당한 변화가 발생됨이 확인되었다.

Evaluation of Sound Insulation Performance of Extruded Cement Panel with a-Hemihydrate Gypsum

  • Kim, Jin-Man;Choi, Duck-Jin
    • 한국건축시공학회지
    • /
    • 제12권6호
    • /
    • pp.575-585
    • /
    • 2012
  • The extruded cement panel, which has many advantages as a prefabricated method, has been limited in its application due to its low fire-resistance. However, an extruded cement panel produced by mixing a-hemihydrate gypsum offers dramatically improved fire-resistance and is expected to have wide-ranging applications in the construction sector as an interior material or partition wall between housing units. Sound insulation performance is very important for the partition wall between housing units. In this study, the sound insulation performance of the extruded cement panel produced through the mixture of a-hemihydrate gypsum is reviewed in order to determine its usability for a partition wall between housing units and for interior materials. Through the review it was found that the wall formed using the extruded cement panels produced by mixing the a-hemihydrate gypsum have ★★★ class in sound insulation test, equal or superior compared with the other two types of extruded cement panel walls currently available in the market.

Failure Investigation of Fire-Side Water-Wall Tube Boiler

  • Fatah, M.C.;Agustiadi, D.;Pramono, A.W.
    • Corrosion Science and Technology
    • /
    • 제20권5호
    • /
    • pp.242-248
    • /
    • 2021
  • Unforeseen failures of boilers in power plants may affect the continuation of electricity generation. Main failures in boilers are influenced by the tube material, tube position, boiler service temperature and pressure, and chemical composition of the feed water and coal. This investigation was intended to find answers on the causes and mechanism of failure of the fire-side boiler water-wall tubes, due to perforation and corrosion. The tube conformed to the material requirements in terms of its chemical composition and hardness. Microscopic examination showed ferrite and pearlite indicating no changes in its microstructure due to the temperature variation. SEM test showed a single layer and homogenous film density particularly on the area far from perforation. However, layers of corrosion product were formed on the nearby perforation area. EDX showed that there were Na, Ca, S, and O elements on the failed surface. XRD indicated the presence of Fe2O3 oxide. The failure mechanism was identified as a result of significant localized wall thinning of the boiler water wall-tube due to oxidation.

외벽 마감재료의 수직화재 확산 연구를 위한 실물화재 실험 (The Real Scale Fire Tests for Vertical Fire Spread Study of External Finishing Material)

  • 권오상;유용호;김흥열;김정현;민세홍
    • 한국화재소방학회논문지
    • /
    • 제26권6호
    • /
    • pp.85-91
    • /
    • 2012
  • 건축물에서 화재 시 인명과 재산의 피해를 줄이기 위해서는 초기의 화염의 확산을 억제하는 것이 우선되어야 한다. 화염의 확산을 방지하기 위한 화재확산방지 대책은 일반적으로 방화구획에서의 구조부재의 내화 성능 확보, 마감재료의 연소 성능에 따른 사용 제한 등이 있다. 마감재료의 연소 성능 판단은 화염의 확산을 판단하기 위해 가장 기초적인 화재 안전 설계이지만 국내의 연소 시험은 시편 크기의 화재 시험 방법으로 연소 성능을 판단하고 있어 샌드위치패널 등과 같은 복합재료의 연소 성능을 판단하기에는 많은 제약을 가지고 있다. 특히 외벽 마감재료의 경우 내부 마감재료에 비해 드라이비트, 알루미늄복합패널, 메탈패널 등과 같은 다양한 복합재료 등이 사용되고 있기 때문에 본 연구에서는 외벽 마감재료의 국제시험규격인 ISO 13785-2 시험방법을 통해 외벽 마감재료의 실물 화재 실험을 통해 외벽 마감재료의 수직화재 확산 특성을 판단하고자 하였다.

구획화재에서 벽면의 열전도 계수와 내부 온도의 상관관계 분석 (Investigation of the Relationship Between Wall Thermal Conductivity and Inner Room Temperature in Compartment Fires)

  • 유우준;고권현
    • 한국화재소방학회논문지
    • /
    • 제32권2호
    • /
    • pp.17-23
    • /
    • 2018
  • 본 연구에서는 Buckingham 파이 정리를 이용하여 구획 공간에서 화재가 발생한 경우 벽면을 구성하는 재료의 열전도 계수와 내부 온도의 상관관계에 관한 연구를 수행하였다. 이를 위해서 기존 무차원 변수의 주요 인자를 고려하여 발열량, 열전도계수, 구획공간의 체적, 벽면 두께 그리고 대류 열전달 계수의 관계를 분석하였다. 또한, 발열량에 대한 화염에서의 최대 온도 그리고 벽면의 온도를 산출하기 위해서 내화보드를 사용하여 ISO 9705 룸 코너 시험기(Room Corner Tester)의 1/6 크기를 갖는 축소 규모의 구조물을 제작하였으며, 10 cm, 15 cm 그리고 20 cm인 정사각형 화원에 대해서 가솔린 화재실험을 수행하여 국부 지점의 산소 농도와 화염에서의 온도분포를 측정하였다. 그 결과 대류 열전달 계수와 열전도 계수의 변화에 따라서 외벽에서의 온도가 증가하는 조건을 제시하였으며, 발열량 변화에 대한 Buckingham 파이의 무차원 경험식을 도출하였다. 본 연구 결과는 구획 공간에서 외벽 형상 및 열전도 계수의 변화를 고려한 화재 현상을 연구하기 위한 기초 자료의 활용이 가능할 것으로 사료된다.

건축물 외벽화재시 Flame Trajectory 추정을 위한 실험적 연구 (Experimental Study on Flame Trajectory in Building External Walls Fire)

  • 신이철;박계원;정재군
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2016년도 춘계 학술논문 발표대회
    • /
    • pp.79-80
    • /
    • 2016
  • In the event of a fire on the outer walls of an architectural structure, through real scale experiments with the purpose of estimating the Flame Trajectory, the behavior and risks of expanded combustion to an upper architectural compartment of the Fire Plume Ejected from an Opening according to changes in the aspect ratio of the opening were examined. The results showed that the more the heat release rate of the fire source increased, the heat capacity of the Fire Plume Ejected from the Opening also increased, and for the case of heptane when compared with methanol or ethanol, the results showed a trend for a significant amount of unburned gas to remain. The results also showed that the larger the aspect ratio was, the more likely it was for the Flame Trajectory to approach the outer walls and rise up. In each of the experiment conditions, as the flame rose from the lower part of the wall to the upper part of the wall, a steady decrease was shown for the temperature distribution. Also by quantitatively analyzing the amount of unburned gas that remained, a method to estimate the temperature of the Fire Plume Ejected from an Opening for a traverse opening was implemented.

  • PDF

Similarity of energy balance in mechanically ventilated compartment fires: An insight into the conditions for reduced-scale fire experiments

  • Suto, Hitoshi;Matsuyama, Ken;Hattori, Yasuo
    • Nuclear Engineering and Technology
    • /
    • 제54권8호
    • /
    • pp.2898-2914
    • /
    • 2022
  • When evaluating energy balance and temperature in reduced-scale fire experiments, which are conducted as an alternative to full-scale fire experiments, it is important to consider the similarity in the scale among these experiments. In this paper, a method considering the similarity of energy balance is proposed for setting the conditions for reduced-scale experiments of mechanically ventilated compartment fires. A small-scale fire experiment consisting of various cases with different compartment geometries (aspect ratios between 0.2 and 4.7) and heights of vents and fire sources was conducted under mechanical ventilation, and the energy balance in the quasi-steady state was evaluated. The results indicate the following: (1) although the compartment geometry varies the energy balance in a mechanically ventilated compartment, the variation in the energy balance can be evaluated irrespective of the compartment size and geometry by considering scaling factor F (∝heffAwRT, where heff is the effective heat transfer coefficient, Aw is the total wall area, and RT is the ratio of the spatial mean gas temperature to the exhaust temperature); (2) the value of RT, which is a part of F, reflects the effects of the compartment geometry and corresponds to the distributions of the gas temperature and wall heat loss.