• Title/Summary/Keyword: Fire sprinkler head

Search Result 58, Processing Time 0.025 seconds

An Experimental Study on the Droplet Size Distribution of Sprinkler Spray for Residential Building (주거용 스프링클러 분무의 액적크기 분포에 관한 실험적 연구)

  • Kim, Sung Chan;Kim, Jung Yong
    • Journal of ILASS-Korea
    • /
    • v.20 no.3
    • /
    • pp.175-180
    • /
    • 2015
  • A series of sprinkler discharging tests was conducted to measure the droplet size and its distribution of residential fire sprinkler heads. Droplet sizes in sprinkler spray were measured using a laser diffraction method for the flush, circular and pendent type sprinkler head. In this study, the $D_{v,50}$ of the flush type sprinkler heads were ranged between $530{\sim}1040{\mu}m$ and those of circular and pendent type were $988{\mu}m$ and $916{\mu}m$, respectively. The measured cumulative volume distributions were followed by a combination of the log-normal and Rosin-Rammler distribution which is widely used in the computational fire analysis and the parameters of distribution function were obtained from the best fit line through the measured data.

A Study on the Revision of the National Fire Safety Codes of Sprinkler System (스프링클러설비 화재안전기준 개정에 대한 고찰)

  • Jeong, Keesin
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.32-37
    • /
    • 2013
  • This paper suggested to revise unreasonable national fire safety codes of sprinkler system. Also proposed to modify the definition of "the gridded sprinkler system" and to add "the feed main" in terms of the definition of the pipes. In order to operate the regulations of discharge pressure of the sprinkler head efficiently, this paper checked the minimum criteria of pressure and flow for the pipe schedule sprinkler system of NFPA 13 and suggested to establish the similar minimum demand criteria. It proposed to be amended properly the pressure calculation formular in the pressure tank system and to use the correct K value due to change in pressure unit and to use the [bar] as a unit of pressure for the sake of using the existing K-factor etc.

A Study on the Effect of Ceiling Type Air Conditioner on Sprinkler Head Operation (천장형 에어컨이 스프링클러 헤드 작동에 미치는 영향에 관한 연구)

  • Yi, Sunyoung;Yoon, Myong O;Lee, Youngju;Lee, Jun
    • Journal of Korean Society of Disaster and Security
    • /
    • v.13 no.1
    • /
    • pp.51-58
    • /
    • 2020
  • This paper analyzes the effect of airflow of ceiling air conditioner on the operation of sprinkler head using a simulation program. The simulation space is 10 m × 7 m × 3 m, and the size of the fire is 0.8 m × 0.8 m × 0.6 m. The cold air flow from the air conditioner is at 25℃ and the wind speed is divided into three cases : 10 ㎧, 8.5 ㎧, and 7.5 ㎧. Simulation results show that all cases had operating delays compared to when the air conditioner was not running, and the sprinkler head did not operate until 10 minutes had elapsed at 10 ㎧ wind speed. These results confirmed that the sprinkler head was delayed in the air conditioning space and the worst result of early evolution failure was observed in strong winds such as 10 ㎧.

Directional Water Spray Characteristics of Sprinkler Heads (스프링클러 헤드의 방향성 살수 특성 비교 연구)

  • Park Yong-Hwan
    • Fire Science and Engineering
    • /
    • v.18 no.4
    • /
    • pp.35-41
    • /
    • 2004
  • The water spray characteristics of the sprinkler heads is a very important factor affecting the fire suppression performance, and it is largely dependent on the shape of the head nozzle. This study investigated shape factors and spray distribution performances for the sprinkler heads of four domestic companies with big market shares. The experimental results revealed that all flow constants exceeded the required regulation limits, however showed big differences between head types although they have the same design limit. They were however relatively consistent regardless of the pressure increases. The spray distribution of some head samples showed severe directional eccentricity, which suggests more study for the improvement.

[Retracted]Evaluation of Early Suppression-Fast Response (ESFR) Sprinklers in Facilities and Residences for Elderly People ([논문철회]노인관련시설에서 조기반응형 스프링클러헤드의 유용성)

  • Choi, Young-Sang;Gong, Ye-Rin;Kong, Ha-Sung
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.15-20
    • /
    • 2015
  • This study compared, through a fire simulation, temperature changes of the smoke layer and the air layer, and height fluctuations of the smoke layer, according to the sprinkler head installation and non-installation, and the sprinkler head types in elderly-care facilities. When a standard response sprinkler worked, the radiant heat exceeded the conditions for the occurrence of flashover. However the ESFR sprinkler prevented flashover. When the early response head worked, inhabitants were not damaged by radiant heat because the maximum value of the heat flux remained $2,293W/m^2$, which is less then the burn hazard criterion of $4,000W/m^2$. The highest temperature of the room when fire occurred exceeded the safety standard in all of the smoke layer and the air layer, but the highest temperature was kept below the safety standard after it fell down rapidly. Because the height of the smoke layer was maintained above 1.1 m when the early response sprinkler worked, the falling of the smoking layer was much more delayed than in the case where the standard response sprinkler was used.

Analysis of Primary Breakup Characteristics Depending on the Boss and Deflector Dimension of Fire Sprinkler Head using LES-VoF (LES-VoF를 이용한 소방용 스프링클러 헤드의 보스 및 디플렉터 치수에 따른 1차 분열 특성 분석)

  • Kim, Taehoon
    • Journal of ILASS-Korea
    • /
    • v.26 no.3
    • /
    • pp.127-134
    • /
    • 2021
  • Fire sprinkler initial spray was analyzed by Large eddy simulation (LES) and Volume of Fluid (VoF) integrated method. The IsoAdvector geometric VoF was used to identify the liquid-gas interface clearly even with the large Courant-Friedrichs-Lewy number. To reduce the computational costs, sector meshes and Adaptive Mesh Refinement up to level 3 were used. Base mesh size was 1 mm, which is roughly equivalent to the initial sprinkler droplet. Top surface radius of boss and deflector size were modified to investigate the effects of sprinkler head design on primary breakup process. When top surface radius of boss was increased, vertical liquid sheet was formed. This phenomenon reduced the sheet breakup radius, sheet thickness and velocity. Due to reduced liquid sheet thickness, a large amount of ligaments was created from the liquid sheet. As a result, there was a dramatic decrease in volume per surface area, indicating an increase in breakup process. Spray pattern viewed in radial direction also changed when top surface radius of boss increased. When top surface radius of boss was increased, a T-shaped pattern was observed while a V-shaped pattern was observed in all other cases. When the deflector size increases, the spray pattern remains V-shaped, even if the top surface radius of boss increased. Further studies on promoting atomization of the water supplied to the lower part of the sprinkler head in the T-shape pattern should be conducted.

Research for the Configuration of the Outside Sprinkler System (외벽방호 스프링클러시스템 구성에 관한 연구)

  • Min, Se-Hong;Yun, Jung-Eun;Sun, Ju-Seok;Jeong, Sang-Ho;Chea, Chang-Hun;Kim, Suck-Jun
    • Fire Science and Engineering
    • /
    • v.26 no.1
    • /
    • pp.102-112
    • /
    • 2012
  • In this research, configulation of outside sprinkler system the prevention and postponement of vertical diffusion of blaze was studied prior to this study, vertical diffusion protecting sprinkler head has been developed and the sprinkler system was applied with discharge pressure of 0.05 MPa and flow of 60 l/min witch is stated in NFPA13's Exposure Protection Sprinkler Systems. Through the system design, we applied the system to the sample building and we made pertinent system to work manually and automatically linked to a fire alarm system. Also, we conducted a real-size mock up test verify the cooling effect of the outer wall and the postponement effect of the flame.