• Title/Summary/Keyword: Fire spread rate

Search Result 101, Processing Time 0.039 seconds

Comparison a Forest Fire Spread variation according to weather condition change (기후조건 변화에 따른 산불확산 변화 비교)

  • Lee, Si-Young;Park, Houng-Sek
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.490-494
    • /
    • 2008
  • We simulated a forest fire which was occurred in Yangyang area on 2005 and compared a results between two different weather conditions(real weather condition and mean weather condition since 1968) using FARSITE, which is a forest fire spread simulator for preventing and predicting fire in USDA. And, we researched a problem in the transition for introducing, so we serve the basic method for prevention and attacking fire. In the result, severe weather condition on 2005 effected a forest fire behavior. The rate of spread under real weather condition was about 4 times faster than mean weather condition. Damaged area was about 10 time than mean weather condition. Therefore, Climate change will make a more sever fire season. As we will encounter to need for accurate prediction in near future, it will be necessary to predict a forest fire linked with future wether and fuel condition.

  • PDF

Semi-numerical Study on the Flame Tilt Equation due to Wind on the Surface Fire in Forest Fire (산불 지표화에서의 바람에 의한 화염각 변화 산정식 도출에 관한 준-수치해석 연구)

  • Kim, Dong-Hyun
    • Fire Science and Engineering
    • /
    • v.23 no.5
    • /
    • pp.90-95
    • /
    • 2009
  • The wind is very important factor in forest fire spread. Flame spread has a change through wind pattern change in forest fire. In order to analyze the forest fire flame spread rate, change of flame tilt depending on wind may be considering first. This is be cause the flame spread rate varies by the flame tilt changed due to transfer of heat. Especially, as wind speed grow, flame gets closer to surface, heat transfer ratio increase, virgin fuel bed reaches ignition temperature more rapidly, and flame moves faster. This study deduces, through experiment and physical figure analysis, relations on the change behavior of flame tilt due to wind. The value of flame tilt angle calculated from the equation and the experiment value showed average error angle of $3.3^{\circ}$, which is relatively smaller than results of previous studies that used other coefficient. Froude number coefficient A can be calculated in the method provided in this research for estimation of flame tilt angle of virgin fuel bed with varying thermal properties. The research finding is expected to be applied to future studies on flame spread through numerical analysis of heat transfer.

Assessment of Grid Sensitivity in the FDS Field Model to Simulate the Flame Propagation of an Electric Cable Fire (케이블 화재의 화염전파 해석을 위한 FDS 모델의 격자민감도 평가)

  • Kim, Sung-Chan;Lee, Seong-Hyuk
    • Journal of the Korean Society of Safety
    • /
    • v.23 no.4
    • /
    • pp.30-35
    • /
    • 2008
  • The present study has been conducted to examine the effect of grid resolution on the predicted results for electric cable fire using pyrolysis model in FDS(Fire Dynamics Simulator, version 5). The grid independent test for different grid resolutions has been performed for a PE coating cable and the grid resolution is defined by the non-dimensional characteristic length of fire and mean grid size. The calculated maximum heat release rate and mean flame spread rate were almost constant for higher grid resolution of 20${\sim}$25 and the computing time for the grid resolution takes approximately 20hours to solve flame propagation with pyrolysis model. The geometrical simplification of a electric cable dose not greatly affect on the maximum heat release rate and flame spread rate and the rectangular approximation of cable shape gives acceptable result comparing with the round cable with stepwise grid.

Slope and Forest Fuel Effect on Spreading of Forest Fire (산불 확산에 영향을 미치는 임지내 산림연료와 경사도에 관한 연구)

  • 채희문;이찬용
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.5 no.3
    • /
    • pp.179-184
    • /
    • 2003
  • This study investigated the relationship of fuel weight and depth together with slope on the spread of forest fire. Fire spread was faster on the greater slope in forested land. Fire had a greater spread rate with lighter fuel weight. The thickness of the fuel bed and forest fire spread rate were not related. The fire spread rate was closely related to the slope and weight of the fuel bed (significant at 0.01, 0.05, respectively). The thickness of the fuel bed was not significant (0.05).

The Water Curtain Installation Guideline for Fire Spread Prevention in Market (재래시장의 화재확산 방지를 위한 수막설비 설치 지침)

  • Choi, Jung-Uk;Cho, Sung-Woo
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.28 no.7
    • /
    • pp.269-274
    • /
    • 2016
  • This paper aims to suggest the water curtain installation guideline for prevention of fire spread. The water curtain systems play a role in preventing fire spread which is caused by fire flames and radiation heat release from a fire source. The radiation attenuation ratio is affected by the water droplet size, vertical distance from the nozzle and flow rate. This study suggests the water curtain installation guideline as follows : (1) Investigation of a reference store array (2) Calculation of the number of drencher heads (3) Review of the relationship between droplet size and attenuation factor depending on the height of the drencher head (4) Review of a drencher head array and spray overlapping. The reference traditional market in which a fire compartment is installed using a water curtain can be predicted to have a radiation attenuation ratio of 50%.

Igniter and Thickness Effects on Upward Flame Spread

  • J.Q. Quintiere;Lee, C.H.
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.154-161
    • /
    • 1997
  • Several studies have developed upward flame spread models which use somewhat different features. However, the models have not considered the transient effects of the igniter and the burning rate. Thus, the objective of this study is to examine a generalized upward flame spread model which includes these effects. We shall compare the results with results from simpler models used in the past in order to examine the importance of the simplifying assumptions. We compare these results using PMMA, and we also include experimental results for comparison. The results of the comparison indicate that flame velocity depends on the thermal properties of a material, the specific model for flame length and transient burning rate, as well as other variables including the heat flux by igniter and flame itself. The results from the generalized upward flame spread model can provide a prediction of flame velocity, flame and pyrolysis height, burnout time and position, and rate of energy output as a function of time.

  • PDF

A Numerical Study of the Effect off Fire Growth Model on Fire Characteristics in a Carriage (화재 성장 모델이 객차내 화재 특성에 미치는 영향에 관한 수치해석적 연구)

  • 김성찬;유홍선;최영기;김동현
    • Journal of the Korean Society for Railway
    • /
    • v.7 no.3
    • /
    • pp.180-185
    • /
    • 2004
  • The present study investigates the effect of fire growth model on fire development characteristics in a carriage. The parallel processing version of FDS code is used to simulate the fire driven flow in a carriage and two types of fire growth model which are flame spread model and t$^2$ model are examined for the same geometrical condition. The heat release rates(HRR) of both model are similar each other until 30 s after ignition, but the flame spread model predicts 5 times higher than those of the t$^2$ fire model during the quasi-steady fire period. Maximum heat release rate in the case of flame spread model reaches about to 12 MW at 100 s after fire ignition. Also, various database of fire properties for combustible materials and more elaborate combustion model considering the flame spreading phenomena are required for better predictions of fire development characteristics using numerical simulation.

A Study on the Modeling of Vertical Spread Fire of Exterior Panel by Fire Dynamic Simulation (FDS) (FDS를 이용한 외장재의 수직 확산 화재의 모델링에 관한 연구)

  • Min, Seh-Hong;Yoon, Jung-En
    • Journal of the Korea Safety Management & Science
    • /
    • v.11 no.2
    • /
    • pp.77-85
    • /
    • 2009
  • Considering heat insulation and beautiful sight of construction, making use of exterior panels is increasing. Recently the exterior panels now are weak very much, and so in consequence of the weakness fire spreads rapidly. Compared with internal fire, external vertical fire spread rate goes rapidly and it is extensive in spread range, therefore it is dangerous very much. Accordingly, under present condition of poor standard of exterior panels, it is required to take measure to meet the appropriate situation. In this study, by making use of FDS(Fire Dynamic Simulation) program about external vertical fire of high rise building, fire behavior is searched by computer. It is important that realizing by computer fire modeling about external vertical fire must be included certainly in procedure of fire performance design in the future. In modeling program, FDS version 5 is available, and aluminium composite panel is applied in external panels. In this study, for realizing of actual fire condition, FDS is applied by details of fire scenarios considering influence of wind.

Influence on forest fire spread & intensity on fuel type of burnt area. (산불피해지역 연료형태가 산불연소에 미치는 영향)

  • Lee, Si-Young;Lee, Myung-Woog;Yeom, Chan-Ho;Kwon, Chun-Geun;Park, Houng-Sek;Lee, Hae-Pyeong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.321-324
    • /
    • 2008
  • Forest fire danger rate of thinning area was lower than that of non thinning area, because height rate of leewardside in burned stem of tree, damage rate of crown and mortality of tree in thinning area were 30.8%, 37% and 48.4% lower than that in non-thinning area, respectively. Intensity of forest fire varied depending upon topographical condition up slope, down slope, aspect, location as well as species, breast height diameter and forest tree density. Especially, a mountaintop area was burned down when forest fire was spread to up slope ridge of mountain.

  • PDF

Characteristics and Risk Assessment of Flame Spreading Over Metal Dust Layers (퇴적금속 분진층을 전파하는 화염의 연소특성과 위험성 평가)

  • Han, Ou-Sup
    • Korean Chemical Engineering Research
    • /
    • v.43 no.1
    • /
    • pp.47-52
    • /
    • 2005
  • The wide use of metal dusts have been found in industrial field and many dust explosion accidents occur by fire spread of dust layer. In this study, we developed a new experimental device to examine fire and explosion characteristics of the dust layer. Aspects of the burning zone over metals(Mg, Zr, Ta, Ti, etc) and PMMA(Polymethyl methacrylate) dust layers have been investigated experimentally to clarify behaviors (Spread rate and quenching distance) and effects of $N_2$ surrounding gas on the fire spread over metal dust layers. From the experimental result, it was found that the spread rate of metal dusts is larger than PMMA, the dependability of spread rate over the thickness of dust layer is small, and the minimum oxygen concentration of spread flame over Mg dust layer is 3.6-3.7 vol%. Since high correlation between the spread rate and the reciprocal of quenching distance was seen, relative risk prediction in those inflammable parameters can be predicted.