• 제목/요약/키워드: Fire side corrosion

검색결과 6건 처리시간 0.009초

Failure Investigation of Fire-Side Water-Wall Tube Boiler

  • Fatah, M.C.;Agustiadi, D.;Pramono, A.W.
    • Corrosion Science and Technology
    • /
    • 제20권5호
    • /
    • pp.242-248
    • /
    • 2021
  • Unforeseen failures of boilers in power plants may affect the continuation of electricity generation. Main failures in boilers are influenced by the tube material, tube position, boiler service temperature and pressure, and chemical composition of the feed water and coal. This investigation was intended to find answers on the causes and mechanism of failure of the fire-side boiler water-wall tubes, due to perforation and corrosion. The tube conformed to the material requirements in terms of its chemical composition and hardness. Microscopic examination showed ferrite and pearlite indicating no changes in its microstructure due to the temperature variation. SEM test showed a single layer and homogenous film density particularly on the area far from perforation. However, layers of corrosion product were formed on the nearby perforation area. EDX showed that there were Na, Ca, S, and O elements on the failed surface. XRD indicated the presence of Fe2O3 oxide. The failure mechanism was identified as a result of significant localized wall thinning of the boiler water wall-tube due to oxidation.

측벽형 스프링클러 헤드 디플렉터의 성헝후처리에 따른 부식특성에 관한 연구 (A Study on the Corrosion According to Post-Forming Treatment of a Horizontal Side Wall Sprinkler Head Deflector)

  • 민인홍;전동일;김형종;박종연
    • 한국화재소방학회논문지
    • /
    • 제16권1호
    • /
    • pp.77-83
    • /
    • 2002
  • 본 연구의 목적은 UL(미국보험협회)에 규정된 암모니아 대기상태에서 측벽형 스프링클러 헤드 디플렉터의 응력부식균열을 막기 위한 방안을 제시하는 것이다. 성형 후처리로서 성형제품 그대로와 샌드블래스팅 처리한 것, 그리고 풀림 열처리를 한 것 등 3가지에 대하여 부식시험을 실시하였다. 금속현미경으로 시편을 관측한 결과 잔류응력이 부식균열을 일으키는 주요원인이며, 극심한 부식조건에서 발생할 수 있는 잔류응력을 적절한 열처리를 통해 제거하거나 감소시킬 수 있어 파손을 방지할 수 있다는 것을 확인 하였다.

보일러관의 수명에 부식이 미치는 영향에 대한 수치해석 (Numerical Analysis of Corrosion Effects on the Life of Boiler Tube)

  • 홍성호;김종성
    • 대한기계학회논문집A
    • /
    • 제24권11호
    • /
    • pp.2812-2822
    • /
    • 2000
  • Several methods have been developed to predict the rupture time of the boiler tubes in thermal power plant. However, existing life prediction methods give very conservative value at operating stress of power plant and rupture strain cannot be well estimated. Therefore, in this study, rupture time and strain prediction method accounting for creep, corrosion and heat transfer is newly proposed and compared with the current research results. The creep damage evolves by continuous cavity nucleation and constrained cavity growth. The corrosion damage evolves by steam side and fire side corrosion. The results showed good correlation between the theoretically predicted rupture time and the current research results. And rupture strain may be well estimated by using the proposed method.

KEMC 규정에 의한 분전반의 제작 및 특성 평가에 관한 연구 (A Study on the Characteristics Assessment and Fabrication of Distribution Board according to KEMC Standards)

  • 이병설;최충석
    • 한국화재소방학회논문지
    • /
    • 제31권3호
    • /
    • pp.63-72
    • /
    • 2017
  • 본 논문에서는 저압용 10회로 분전반을 전기공업협동조합(KEMC) 2102-610 규정에 근거하여 제작하였다. 또한, 개발된 10회로 분전반의 특성 평가를 실시하여 안전성을 확보하고자 한다. 개발된 10회로 분전반은 내식성, 절연 재료의 특성, 자외선 복사의 내성, 기계적 충격 등에 적합하도록 설계되었다. 개발된 분전반은 외함의 보호 등급, 감전방지와 보호회로, 개폐 장치와 구성품, 내부 전기 회로와 연결부, 외부 도체의 단자, 절연 특성, 온도 상승 시험, 열저항 등이 적합하도록 제작하였다. 개발된 10회로 분전반은 단상 회로와 3상 회로 등으로 구분되어 있다. 분기된 각각의 차단기 부하측에 센서 모듈을 설치하여 부하의 전선로에서 발생되는 누설전류의 크기를 실시간 측정할 수 있다. 그리고 부하의 용도 및 목적 등에 따라 회로를 증설할 수 있고, 각각의 부하 상태 역시 실시간 부하 관리 및 점검이 가능하다. 개발된 10회로 분전반의 온도 상승 시험을 실시한 곳은 인입 접속부, 주회로 및 분기회로 모선, 모선지지물 등 18 개소이다. 온도가 가장 높게 측정된 곳은 분기회로 모선용 MCCB 전원측 접속부의 R-phase으로 $65.3^{\circ}C$, 부하측은 T-phase으로 $61.6^{\circ}C$로 기록되었다. 그리고 내열 실험 장치를 이용하여 MCCB를 $180^{\circ}C$에서 6시간 동안 열적 스트레스를 인가하였을 때 작동 손잡이의 변형이 확인되었고, 트립 상태로 이동한 것이 확인되었다.

온실의 유지관리 실태조사 분석 (Field Survey on the Maintenance Status of Greenhouses in Korea)

  • 최만권;윤성욱;김현태;이시영;윤용철
    • 생물환경조절학회지
    • /
    • 제23권2호
    • /
    • pp.148-157
    • /
    • 2014
  • 본 연구는 농가들의 온실 유지관리 실태를 알아보기 위해서 국내에 보급되어 있는 온실에 대해 전국을 대상으로 온실규격, 자연재해 예방 및 피해상황, 온실 구조재, 온실 피복재 등에 관한 실태를 조사하여 자료를 분석하였다. 그 결과를 요약하면 다음과 같다. 온실의 규격의 경우, 길이는 단동 및 연동 온실 모두 90m이상이 가장 많았다. 폭은 단동온실 및 연동 온실이 각각 8m이상 및 7.0~7.9m, 측고 1.5~1.9m 및 2.0~2.9m, 동고 3.0~3.9m 및 6m가 가장 높은 비율을 차지하는 것으로 나타났다. 내재해형 온실을 조사한 결과 농가에서 내재해형 온실 설치를 기피하는 것으로 조사되었다. 온실의 자연재해 피해는 대설 보다 태풍에 대한 피해를 많이 받는 것으로 조사되었다. 자연재해 예보 시 점검사항의 경우, 태풍 예보가 있을 때에는 천창, 측창, 출입문 및 피복재 고정밴드를 주로 점검하며, 대설 예보가 있을 때에는 난방기를 주로 점검하는 것으로 나타났다. 온실파이프에 부식이 발생 시 보수방법은 도색 보다는 부분적인 교체를 많이 하고, 자연재해 예방을 위한 구조물의 보강재를 대부분 사용하지 않는 것으로 나타났다. 온실 피복재의 유지관리는 대부분의 농가에서 피복재 밀폐성을 점검하는 것으로 나타났지만, 광 투과를 위한 피복재의 청소는 대부분 하지 않는 것으로 나타났다. 태풍시 온실 피복재를 제거하면 구조재 파괴를 막을 수 있는데 그렇게 못하는 이유는 피복재의 교체비용, 재배작물 때문인 것으로 파악되었다. 그리고 온실농가에서 화재예방을 위한 소방설비 구비 여부에 대해 조사한 결과, 온실의 화재예방 인식이 많이 부족한 것으로 나타났다.