• 제목/요약/키워드: Fire room range

검색결과 26건 처리시간 0.023초

A Room-Corner Fire Model을 적용한 건축내장재의 화재확산 특성 평가(1)

  • 김운형
    • 방재기술
    • /
    • 통권24호
    • /
    • pp.32-39
    • /
    • 1998
  • A room-corner fire scenario of ISO 9705 with flame spread model developed by Quintiere is applied to the interior finish materials to show the sensitivity of properties derived from AST, E-1321 and ASTM E-1354 is investigated and various range of thermal properties by the author were analyzed in the model. There are including flame heat flux and thermal inertia, lateral flame spread parameter, heat of combustion and effective heat of gasfication. The time for total energy release rate to reach 1MW is examined. Though some areas are neede for improvements, The model appears to predict good results with all the range of input properties and could be

  • PDF

부속실 출입문 크기 변화를 고려한 개방 및 폐쇄조건 분석 (An Analysis of the Opening and Closing Condition with Various Fire Door Size in the Pressurized Room)

  • 유우준;남준석;유홍선
    • 한국화재소방학회논문지
    • /
    • 제25권2호
    • /
    • pp.132-137
    • /
    • 2011
  • 부속실 단독가압의 제연설비 구역에서 계단실 출입문의 크기 변화가 개방 및 폐쇄조건에 미치는 영향을 분석하기 위해서 자동폐쇄장치의 구조와 저항모멘트의 관계를 정리하였으며, 부속실 출입문의 크기 변화를 고려하여 개방력과 폐쇄력을 측정하였다. 그 결과 부속실 출입문의 크기가 증가할수록 개방 및 폐쇄조건에 도달하기 위한 힘의 크기는 증가하였으며, 폐쇄시간, 회전속도, 회전각도와 힘의 관계, 자동폐쇄장치의 효율을 고려한 부속실 출입문의 설계범위가 존재함을 확인하였다.

화재 후 운전원수동조치(OMA) 정량화를 위한 화재 인간신뢰도분석 (HRA) 요소에 대한 고찰 (An Investigation of Fire Human Reliability Analysis (HRA) Factors for Quantification of Post-fire Operator Manual Actions (OMA))

  • 최선영;강대일;정용훈
    • 한국안전학회지
    • /
    • 제38권6호
    • /
    • pp.72-78
    • /
    • 2023
  • The purpose of this paper is to derive a quantified approach for Operator Manual Actions (OMAs) based on the existing fire Human Reliability Analysis (HRA) methodology developed by the Korea Atomic Energy Research Institute (KAERI). The existing fire HRA method was reviewed, and supplementary considerations for OMA quantification were established through a comparative analysis with NUREG-1852 criteria and the review of the existing literature. The OMA quantification approach involves a timeline that considers the occurrence of Multiple Spurious Operations (MSOs) during a Main Control Room Abandonment (MCRA) determination and movement towards the Remote Shutdown Panel (RSP) in the event of a Main Control Room (MCR) fire. The derived failure probability of an OMA from the approach proposed in this paper is expected to enhance the understanding of its reliability. Therefore, it allows moving beyond the deterministic classification of "reliable" or "unreliable" in NUREG-1852. Also, in the event of a nuclear power plant fire where multiple OMAs are required within a critical time range, it is anticipated that the OMA failure probability could serve as a criterion for prioritizing OMAs and determining their order of importance.

에지 컴퓨팅 환경에서 비콘을 활용한 특수건물 화재 경보 시스템 개선 방안 연구 (A Study on the Improvement of Fire Alarm System in Special Buildings Using Beacons in Edge Computing Environment)

  • 이태규;최경서;신연순
    • 정보처리학회논문지:컴퓨터 및 통신 시스템
    • /
    • 제11권7호
    • /
    • pp.217-224
    • /
    • 2022
  • 오늘날 기술과 산업의 발전으로 특수건물이 늘어남에 따라 특수건물 내 화재 사고가 증가하고 있다. 그러나 정보통신기술의 빠른 발전에도 불구하고 낙후되고 실효성을 갖추지 못한 실내 화재 경보 시스템을 사용함으로 인해 인명 피해가 꾸준히 발생하고 있다. 본 연구에서는 음향경보를 이용하는 기존 실내 화재 경보 시스템이 건물 내 인원들에게 충분한 경보를 전달하지 못하는 '경보의 사각지대 문제'를 개선하고자 에지 컴퓨팅과 비콘을 활용한 화재 경보 시스템을 설계하고 구현하였다. 제안하는 개선된 화재 경보 시스템은 말단 센서 노드와 에지 노드, 사용자 애플리케이션, 서버로 구성된다. 말단 센서 노드는 실내 환경 데이터를 수집하여 에지 노드로 전송하고, 에지 노드는 전송받은 정보를 기반으로 화재 발생 여부를 모니터링 한다. 또한 에지 노드는 비콘 신호를 지속적으로 발생시켜 신호 범위 내의 사용자 애플리케이션이 설치된 스마트기기의 정보를 수집하여 서버 데이터베이스에 저장하고, 화재 발생 시 수집한 기기들의 정보를 바탕으로 모든 재실 인원에게 애플리케이션 푸시 형태로 화재 경보를 전송한다. 구현한 화재 경보 시스템의 적용 가능성을 검증하기 위해 강의실이 밀집한 대학교의 한 건물에서 신호 유효 범위 측정 실험을 진행한 결과, 에지 노드의 비콘 신호 범위 내에서 정상적으로 기기 정보를 수집하고, 수집한 정보를 바탕으로 특정 사용자들에게 신속하게 화재 경보를 전송함을 확인하였다. 이를 통해 수시로 변하는 출입자들의 정보를 유동적으로 수집하고, 이를 바탕으로 사용자와 매우 인접한 스마트기기로 경보를 전송함으로써 '경보의 사각지대 문제'를 해결하는데 적용할 수 있음을 확인하였다. 또한 실험 결과 분석을 통해 제안하는 화재 경보 시스템을 실내 공간의 특징에 따라 효과적으로 적용하는 방안을 제시하였다.

성능위주설계자들의 화재실 범위 설정 방식에 따른 소요피난안전시간(RSET) 비교 및 오차산정에 관한 연구 (A Study on Required Safe Egress Time (RSET) Comparison and Error Calculation in Relation to Fire Room Range Set Conditions of Performance Based Fire Safety Designers)

  • 백소나;최준호;홍원화;정종진
    • 한국화재소방학회논문지
    • /
    • 제30권3호
    • /
    • pp.73-78
    • /
    • 2016
  • '화재예방, 소방시설 설치유지 및 안전관리에 관한 법률'에 의하면 지하층 포함 30층 이상 고층 건축물에 대해 화재발생에 따른 위험성을 사전에 과학적으로 평가하여 재난발생 시 인명피해 및 재산피해를 최소화시킬 수 있도록 성능위주 설계를 실시해야 한다. 이에 따라 설계자는 컴퓨터 시뮬레이션 모델링 등 과학적인 분석 기법을 활용하여 거주자의 화재 및 피난 안전성을 평가하고 있다. 이 때, 인명안전성 평가를 위해 가용피난안전시간(ASET)과 소요피난안전시간(RSET) 을 산정하게 되는데 RSET 중에서도 가장 중요한 '반응시간(Response Time)'을 산정함에 있어 우리나라 사람들에 대한 실측 데이터에 기반한 명확한 법적 기준이 제시되지 못하고 있는 것이 현실이다. 이에 '소방시설 등의 성능위주설계 방 법 및 기준, 별표1'을 토대로 설계자별로 각각 상이한 값을 선택, 입력하거나 일본건축센터의 '건축방재계획지침'에 따라 계산하고 있는 경향을 보이고 있다. 따라서 본 연구에서는 최근 5년간 부산지역에서 성능위주 설계대상으로 지정된 고층 특정소방대상물을 대상으로 총 6명의 설계자가 실시한 성능위주 설계안 13건을 중심으로 RSET의 계산방법에 대해 비교 분석하였고, 특히 RSET 계산 시 결과값에 가장 큰 영향을 미치는 반응시간의 계산방법에 대한 결과를 비교하여 오차값을 산정하였다.

고층건축물의 피난경로 가압제연시스템 성능개선대책에 관한 연구 (A Study on Performance Improvement Measures of Pressurized Smoke Control Systems for Exit Passageways of High-Rise Buildings)

  • 손봉세;김진수
    • 설비공학논문집
    • /
    • 제21권12호
    • /
    • pp.703-714
    • /
    • 2009
  • One of the biggest problems in smoke control systems for high-rise buildings is stack effect, but there are no recognized methods or measures to solve the problem of stack effect as yet. The stack effect can be overcome by forming the uprising current inside the stair hall properly, but there is a limit to the height in supplying into the stair hall the smoke control air volume to be supplied to a floor in case of escape from fire. The limit to the height can be extended by over-coming the stack effect by pressurizing the stair hall and the ancillary room simultaneously. It can also be anticipated that the stack effect can be overcome by connecting the air supply shaft to the stair hall at the top. As a result of computer simulations using a network type of tool, it is found that adequate performance can be achieved by pressurizing the stair hall only for a building of 190m or less, and up to 360m when pressurizing the stair hall and the ancillary room simultaneously. In all those cases, however, an overpressure venting damper is required which operates within a suitable range for venting the overpressure outside.

수음실 잔향시간 변화에 따른 중량 충격음 레벨 특성 - 실험실 환경을 중심으로 - (Floor Impact Sound Pressure Level Characteristics by the Change of Reverberation Time in Mock-up Test Rooms)

  • 정정호;이병권;연준오;전진용
    • 한국소음진동공학회논문집
    • /
    • 제24권4호
    • /
    • pp.339-347
    • /
    • 2014
  • Floor impact sound in high-rise apartment building became one of social problems. A lot of civil complaints on floor impact sound occur continuously and the number of disputes between neighbors in small and aged apartment buildings is increasing. Interests on heavy-weight impact sound pressure level measurement and evaluation method is increased. Previous study reported that heavy-weight impact sound level was changed by the sound field condition of receiving reverberation chamber. In this study, heavy-weight impact sound pressure level change by the receiving sound field condition was measured in standard test facility and mock-up test room. These two experimental conditions were designed to simulate averaged living room of common apartment units. By the change of sound absorption power in receiving room, heavy-weight impact sound pressure level in most of frequency bands were changed in standard test facility and mock-up room. Normalized maximum sound pressure level regulated in ISO 16032 showed wider range of heavy/soft impact sound pressure level. Heavy/soft impact sound pressure level change was became smaller by the application of standardized maximum sound pressure level and ISO/CD 10140-3 Amd 2 method. In the case of standardized maximum sound pressure level, absolute sound pressure level changed. From these results, receiving sound field correction method regulated in ISO/CD 10140-3 Amd 2 is needed for the precision measurement and evaluation of heavy-weight impact sound.

다중구획공간내 분무화재시 화재해석모델의 온도장 검증연구 (A Validation Study of Temperature Field Predicted by Computational Fire Model for Spray Fire in a Multi-Compartment)

  • 김성찬
    • 한국화재소방학회논문지
    • /
    • 제28권5호
    • /
    • pp.23-29
    • /
    • 2014
  • 다중구획공간내의 분무화재에 대하여 화재해석모델의 타당성을 파악하기 위해 BRANZFIRE 존 모델과 FDS 필드모델의 해석결과를 실화재 실험결과와 비교하였다. 분무화재 형성에 사용된 연료는 톨루엔과 메탄올이며 개방된 ISO-9705 공간에서 화재실험을 수행하여 발열량을 측정하였다. 화재발생공간과 복도공간에서 FDS 모델의 예측온도는 실험결과와 잘 일치하였으며 존 모델의 경우도 해석모델의 단순함에도 불구하고 만족할 만한 결과를 제공했다. FDS 모델의 타당성을 평가한 결과, 화재해석의 평균온도는 최대 오차 25% 범위에서 실험결과와 일치하고 있으며 전체 위치에 대한 평균값은 ${\pm}10%$ 이내로 신뢰할 만한 결과를 제공했다. 본 연구는 타당성 평가를 바탕으로 화재해석모델의 적용범위를 확대하고 모델한계를 설정함과 동시에 신뢰성 높은 화재안전성 평가에 활용하기 위한 근거자료를 제공하고자 한다.

고열 환경에서의 구조용 강재 특성 데이터베이스 구축 (Derivation of the Mechanical Properties of Structural Steels at High Temperatures)

  • 권인규
    • 한국화재소방학회논문지
    • /
    • 제21권3호
    • /
    • pp.47-55
    • /
    • 2007
  • 화재와 같은 고열환경에서 강구조 건축물의 구조적 붕괴 예측 및 화재피해 건축물의 안전진단 그리고 보수보강을 위해서는 고온에서의 항복강도와 탄성계수 등과 같은 특성치가 반드시 요구된다. 따라서 본 연구에서는 강구조 건축물의 주요 구조부에 적용되는 주요 강종인 일반 구조용 SS 400과 용접 구조용 SM 490을 대상으로 상온에서 $100^{\circ}C$ 간격으로 $900^{\circ}C$까지 고온인장시험을 통하여 0.2% 옵?V 항복강도, 1% 옵?V 항복강도, 인장강도 및 탄성계수 등을 측정하였다.

냉복도 밀폐시스템을 적용한 서버실의 실내온도조건 (Server Room Temperature Condition in Data Center with Cold Aisle Containment System)

  • 정용호;장현재;서장후
    • 설비공학논문집
    • /
    • 제25권2호
    • /
    • pp.79-84
    • /
    • 2013
  • In this study, a cold aisle containment system was proposed among various strategies to reduce the energy waste by recirculation air from the hot aisle. To verify the effectiveness of the cold aisle containment system, a test bed which is similar to an actually existing server room was set up in the Internet Data Center(IDC) building. Comparative experiments, conventional open type cooling system and cold aisle containment system were carried out under actual conditions. The result revealed that the range of inlet temperature of the server system was $20{\sim}25^{\circ}C$ in an existing cooling system and the range of inlet temperature dropped below $20^{\circ}C$ by the cold aisle containment system. After all, cold aisle containment system was proved to be the solution for energy saving cooling system.