A Study on the Life Risk Assessment of Ship's Engine Room Fire (기관실화재 인명위험성평가에 관한 연구)

  • Han, Sang-Kook;Cho, Dae-Hwan;Park, Chan-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.283-289
    • /
    • 2006
  • This study is a preparation for the application of FSA (Formal Safety Assessment) to the fire safety of ships. FSA is the new-fashioned methodology proposed to prevent ships from the accidents. To make a base of the fire safety assessment about ship's fire protection design and Classification Society rule, statistical informations for the fire safety engineering are investigated. From results, the necessity of new criterion for ship's fire safety design, the need to study the human behavior in the evacuation from fire, and the development of new fire progress model considering special situations in ships are acknowledged.

  • PDF

A Study on Disaster Prevention and Risk Assessment System Applying Combustion Velocity at Traditional Housing Zone (전통건축물보존지구내에서의 연소속도식을 고려한 방재계획의 수립과 재난위험도평가 시스템 구축에 관한 연구)

  • 김희성;노삼규
    • Fire Science and Engineering
    • /
    • v.15 no.4
    • /
    • pp.1-9
    • /
    • 2001
  • The purpose of this study is to set up disaster prevention plan and risk assessment system considering combustion velocity at traditional housing zone. The combustion velocity analysis could contribute to build in disaster prevention technique through the potential risk analysis of the area, such analysis also able to set up comprehensive disaster prevention management system. Following results have achieved through the combustion velocity calculation. \circled1 The combustion velocity was calculated in order of the below winds, the above winds and the side winds. \circled2 It must be careful to set up disaster prevention plan in case of the below winds. \circled3 The combustion velocity was calculated at the density Bone where neighboring Distance and Length was small. \circled4 It proved that factors of each parameter not mostly effect to analyse the combustion velocity in limit of the 30 minutes after ignition. \circled5 At the density zone where Distance and Length is small the duration of transfer to neighboring house takes up to 4 minutes, it is required to set up of emergency response plan to minimize the fire dispersion.

  • PDF

Derivation of Building Fire Safety Assessment Factors for Generating 3D Safety Status Map (3D 안전상태지도 제작을 위한 건물 화재안전 평가항목 도출)

  • Youn, Junhee;Kim, Taehoon
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.21 no.10
    • /
    • pp.40-47
    • /
    • 2020
  • Various technologies, systems, and legal systems are applied to prevent and quickly respond to fire disaster; nevertheless, the damages to life and property caused by fires are not reduced every year. For managing fire disaster, generating spatial information-based safety status map and procuring suitability of attribute information for each position information are essential. The safety status map is generated by deriving the fire safety status assessment factors, indexing, and locating the surveying results through various methods. In this paper, we deal with derivation of building fire safety assessment factors for 3D safety status map. At first, we survey the foreign and domestic fire assessment model cases and its factors, and analyze the applicability of Korean 3D fire safety status map. Next, assessment factors for fire safety assessment model are derived. Assessment factors are derived and categorized by their information collecting activity; factors that can be accessed through basic building information and factors that can be accessed through field survey. As a derivation result, 14 assessment factors were derived over five categories(Industry Risk, Structural Risk, Fire Fighting Facility, Fire Dangerousness, Fire Response Status).

Optimal Bayesian MCMC based fire brigade non-suppression probability model considering uncertainty of parameters

  • Kim, Sunghyun;Lee, Sungsu
    • Nuclear Engineering and Technology
    • /
    • v.54 no.8
    • /
    • pp.2941-2959
    • /
    • 2022
  • The fire brigade non-suppression probability model is a major factor that should be considered in evaluating fire-induced risk through fire probabilistic risk assessment (PRA), and also uncertainty is a critical consideration in support of risk-informed performance-based (RIPB) fire protection decision-making. This study developed an optimal integrated probabilistic fire brigade non-suppression model considering uncertainty of parameters based on the Bayesian Markov Chain Monte Carlo (MCMC) approach on electrical fire which is one of the most risk significant contributors. The result shows that the log-normal probability model with a location parameter (µ) of 2.063 and a scale parameter (σ) of 1.879 is best fitting to the actual fire experience data. It gives optimal model adequacy performance with Bayesian information criterion (BIC) of -1601.766, residual sum of squares (RSS) of 2.51E-04, and mean squared error (MSE) of 2.08E-06. This optimal log-normal model shows the better performance of the model adequacy than the exponential probability model suggested in the current fire PRA methodology, with a decrease of 17.3% in BIC, 85.3% in RSS, and 85.3% in MSE. The outcomes of this study are expected to contribute to the improvement and securement of fire PRA realism in the support of decision-making for RIPB fire protection programs.

Establishing the Method of Risk Assessment Analysis for Prevention of Marine Accidents Based on Human Factors: Application to Safe Evacuation System

  • Fukuchi, Nobuyoshi;Shinoda, Takeshi
    • Journal of Ship and Ocean Technology
    • /
    • v.4 no.4
    • /
    • pp.19-33
    • /
    • 2000
  • For the prevention of marine accidents based on human factor, the risk assessment analysis procedure is proposed which consists of (1) the structural analysis of marine accident, (2) the estimation of incidence probability based on the Fault Tree analysis, (3) the prediction of ef-fectiveness to reduced the accident risk by suitable countermeasures in the specified functional system, and (4) the risk assessment by means of minimizing of the total cost expectation and the background risk. As a practical example, the risk assessment analysis for preventing is investigated using the proposed method.

  • PDF

A Study on Fire Protection of Chemical Plants Using FRA (Fire Risk Assessment) Method (FRA(Fire Risk Assessment)기법을 이용한 화학공장의 Fire Protection에 관한 연구)

  • Han, Seung-Hoon;Yoo, Byung-Tae;Tae, Chan-Ho;Chae, Chung Keun;Ko, Jae Wook
    • Journal of the Korean Institute of Gas
    • /
    • v.20 no.5
    • /
    • pp.17-26
    • /
    • 2016
  • Chemical plants and oil gas refinery facilities are intrinsically vulnerable to industrial hazards, such as explosion or fire. Especially, the fire is extremely dangerous to facility structures and plant personnel because of direct flame, radiant heat and smoke. In addition, it has the ripple effect of destroying infra-structures and polluting the environment. In an effort to tackle these potential industrial risks, the procedure of FRA techniques in chemical plants were investigated. The main focus was put on the time variation of physical properties of the main building, i.e. control rooms, warehouses and electrical substations, from a direct flame contact and radiant heat. The deformation of a building due to fire was monitored and modeled with respect to time variable. A variety of case studies, domestic and abroad, was tested in the model to verify the FRA procedure. The developed model was proven to be highly effective to reduce the possible risks at chemical plants. An accurate accident frequency prediction and damage quantification was made by the developed model.

Identifying Hazard of Fire Accidents in Domestic Manufacturing Industry Using Data Analytics (국내 제조업 화재사고 데이터 분석을 통한 복합 유해·위험요인 확인)

  • Kyung Min Kim;Yongyoon Suh;Jong Bin Lee;Seong Rok Chang
    • Journal of the Korean Society of Safety
    • /
    • v.38 no.4
    • /
    • pp.23-31
    • /
    • 2023
  • Revising the Occupational Safety and Health Act led to enacting and revising related laws and systems, such as placing fire observers in hot workplaces. However, the operating standards in such cases are still ambiguous. Although fire accidents occur through multiple and multi-step factors, the hazards of fire accidents have been identified in this study as individual rather than interrelated factors. The aim has been to identify multiple factors of accidents, outlining fire and explosion accidents that recently occurred in the domestic manufacturing industry. First, major keywords were extracted through text mining. Then representative accident types were derived by combining the main keywords through the co-word network analysis to identify the hazards and their relationships. The representative fire accidents were identified as six types, and their major hazards were then addressed for improving safety measures using the identification of hazards in the "Risk Assessment" tool. It is found that various safety measures, such as professional fire observers' training and clear placement standards, are needed. This study will provide useful basic data for revising practical laws and guidelines for fire accident prevention, system supplementation, safety policy establishment, and future related research.

A Study on Risk Assessment for Fire Onboard a Naval Vessel (해군함정 화재 위험도 평가에 관한 연구)

  • Jeon, Gae-Ryong;Kim, Dong-Jin
    • Fire Science and Engineering
    • /
    • v.22 no.5
    • /
    • pp.35-42
    • /
    • 2008
  • With the huge navy projects such KDX-III, LPX, bigger and more complicated vessel constructions are being underway in navy. In this paper, considering these trends, we performed a risk analysis on the navy vessel for the fatality of soldiers on board and presented the risk level with FN curve. Assuming a fire occurs in one of the soldier bedrooms, we established event tree to visualize the possible development scenarios and calculated the fatality for each scenario. The critical condition to survive inside the bedroom was obtained through CFAST program.

Risk Assessment of Compressor Room for Next Generation LNG Carriers (차세대 LNG선 컴프레서룸의 위험성 해석)

  • Moon, Ki-Ho;Song, Seok-Lyong;Jeong, Sam-Heon;Ha, Jong-Phil
    • Special Issue of the Society of Naval Architects of Korea
    • /
    • 2008.09a
    • /
    • pp.76-83
    • /
    • 2008
  • New and more efficient propulsion systems are required for LNG carriers. One of the proposed systems is a combination of a gas turbine with a heat recovery steam generator. This system constitutes a novel approach, which needs to be analyzed by system analysis and risk assessment to compensate for the lack of field experience. Of specific concern is the high pressure fuel supply system. This paper describes the dispersion and fire analysis performed to identify for safety and design improvement of proposed system.

  • PDF

DEVELOPMENT OF AN INTEGRATED RISK ASSESSMENT FRAMEWORK FOR INTERNAL/EXTERNAL EVENTS AND ALL POWER MODES

  • Yang, Joon-Eon
    • Nuclear Engineering and Technology
    • /
    • v.44 no.5
    • /
    • pp.459-470
    • /
    • 2012
  • From the PSA point of view, the Fukushima accident of Japan in 2011 reveals some issues to be re-considered and/or improved in the PSA such as the limited scope of the PSA, site risk, etc. KAERI (Korea Atomic Energy Research Institute) has performed researches on the development of an integrated risk assessment framework related to some issues arisen after the Fukushima accident. This framework can cover the internal PSA model and external PSA models (fire, flooding, and seismic PSA models) in the full power and the low power-shutdown modes. This framework also integrates level 1, 2 and 3 PSA to quantify the risk of nuclear facilities more efficiently and consistently. We expect that this framework will be helpful to resolve the issue regarding the limited scope of PSA and to reduce some inconsistencies that might exist between (1) the internal and external PSA, and (2) full power mode PSA and low power-shutdown PSA models. In addition, KAERI is starting researches related to the extreme external events, the risk assessment of spent fuel pool, and the site risk. These emerging issues will be incorporated into the integrated risk assessment framework. In this paper the integrated risk assessment framework and the research activities on the emerging issues are outlined.