• Title/Summary/Keyword: Fire retardants

Search Result 55, Processing Time 0.019 seconds

A Study on the Fire Resistance of Korean Cellulose Insulation (국내 섬유질 단열재의 내화성능에 관한 연구)

  • Kwon, Young-Cheol;Hwang, Jung-Ha;Yu, Hyung-Kyu
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.4
    • /
    • pp.10-16
    • /
    • 2008
  • The fire resistance of thermal insulation and interior finishing materials is recently much emphasized after the fire accident at the Icheon Cold Store in January 2008. Three kinds of thermal insulation are used in buildings. They are Organic, Non-organic and cellulosic insulation. Organic insulation such as polystyrene foam board and urethane foam has high thermal resistance but it has no fire resistance. While non-organic insulation such as rockwool and glassfiber has high fire resistance, it has lower thermal resistance than organic insulation. Cellulose insulation is primarily manufactured from recycled newsprint or cardboard using shredders and fiberizers. Despite of its environmental friendliness and high thermal resistivity, its domestic use has not much increased because of the prejudice that paper can easily burn. However, the cellulose insulation as a product is about 80 wt.% cellulosic fiber and 20 wt.% chemicals, most of which are fire retardants such as boric acid and ammonium sulfate. It is required to secure its fire safety for more consumption as a building insulation in Korea. Therefore, this study investigates the fire resistance of Korean cellulose insulation according to the rate of fire retardant and finally presents the optimum rate of fire retardant in cellulose as building insulation. The fire safety test was conducted according to the ASTM C 1485-00. The test results indicate that above 18 wt% of fire retardant is necessary to secure the fire safety of cellulose insulation.

Combustion Characteristics Analysis of a Non-class 1E Cable for Nuclear Power Plants according to Aging Period (경년열화 기간에 따른 원자력발전소용 비안전등급 케이블의 연소특성 분석)

  • Kim, Min Ho;Lee, Seok Hui;Lee, Min Chul;Lee, Sang Kyu;Lee, Ju Eun
    • Journal of the Korean Society of Safety
    • /
    • v.35 no.5
    • /
    • pp.22-29
    • /
    • 2020
  • In this study, combustion and smoke release characteristics of a non-class 1E cable for nuclear power plants were investigated according to aging period. The aging was reproduced through an accelerated aging method for interval of 10 years :10, 20, 30 and 40 year, which was applied the Arrhenius equation. The cable was subjected to accelerated aging. In order to understand combustion and smoke release characteristics, the cone calorimeter test was performed according to the standard code of KS F ISO 5660-1. Heat release rate, mass loss rate, average rate of heat emission and smoke production rate were examined through cone calorimeter test. Fire performance index, fire growth index and smoke factor were derived from test results for the comparison of quantitative fire risk. When comparing the fire performance index and the fire growth index, the early fire risk tends to decrease as aging progresses, which might be attributed from the fact that the volatile substances of cables were evaporated. However, when comparing the heat release rate, average rate of heat emission and mass loss rate, which represent the mid and late periods of the fire risk, the values of accelerated aging cables were much higher than those of non-aged cable, which signifies the unstable formation of the char layer resulted in the change in the performance of flame retardants. In addition, the results from the smoke characteristics show that the accelerated aging cables were lager than the non-aged cables in terms of overall fire risk. These results can be used as baseline data when assessing fire risk of cables and establishing fire safety code for nuclear power plants.

The Flame Retardant and Mechanical Properties of Wood Flour-High Density Polyethylene Composites (목분-HDPE 복합체의 난연성 및 기계적 성질)

  • Shin, Baeg-Woo;Bang, Dae-Suk;Song, Young-Ho;Chung, Kook-Sam
    • Journal of the Korean Society of Safety
    • /
    • v.27 no.1
    • /
    • pp.26-31
    • /
    • 2012
  • Wood-plastic composites represents a growing class of materials used by the residential construction industry and furniture industry. In this study, the effect of flame retardants on the flammability and mechanical properties of wood flour-high density polyethylene(HDPE) composites were studied. we were manufactured wood flour-HDPE composites by modular intermeshing co-rotating twin screw extruder with L/D ratio of 42. The flame retardant properties were used limiting oxygen index(LOI) and mechanical properties were measured by universal testing machine(UTM). The Morphological analysis of composites were analyzed by Scanning electron microscope(SEM). It was found that Ammonium polyphosphate can effectively reduce the flammability of the wood flour-HDPE composites. Marginal reduction in the mechanical properties of the composites was found with addition of flame retardants. SEM images showed that the coupling agent improved wood flour-HDPE interfacial bonding.

A Study on Combustion Property of Cellulose Insulation according to Particle Size (입도에 따른 셀룰로오스 단열재의 연소특성에 관한 연구)

  • Choi, Jeong-hwa;Kim, Hong;Yoo, Kyong-Ok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1996.11a
    • /
    • pp.62-67
    • /
    • 1996
  • The smouldering combustion of cellulose Insulation treated with boric acid - borax - aluminium sulfate as combustion retardants are examined by candle type combustibility tester. The flammability behavior of combustion process is LOI, Smouldering region, Smouldering, Flamming spread region and Flame spread region. In this experiment, Particle size of four examined LOI, L.Point, H.Point, at the biggest size show high LOI. The surface area is connected with thermal conduction. The phenomena of combustion transition are governed by quantity of combustible gas generation in heating zone of cellulose insulation.

  • PDF

Combustion characteristics and thermal stability of Wood flour-Polypropylene Composites with flame retardants (난연제를 첨가한 목분-폴리프로필렌 복합재의 연소 및 열적특성)

  • Song, Young-Ho;Shin, Baeg-Woo;Bang, Dae-Suk;Chung, Kook-Sam
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2012.04a
    • /
    • pp.26-29
    • /
    • 2012
  • 본 연구에서는 목분-폴리프로필렌 복합재의 연소성 및 열적특성을 평가하기 위하여 한계산소지수 실험 및 열중량 분석실험을 실시하였다. 목분-폴리프로필렌 복합재의 제조를 위하여 이축압출기를 활용한 압출공정과 사출성형기를 활용한 사출공정을 이용하였다. 그리고 복합재의 난연성능 향상을 위하여 난연제(4종류)를 첨가한 복합체의 화재성능을 평가하였다.

  • PDF

THE PARTICLE SIZE EFFECT ON COMBUSTION BEHAVIOR OF CELLULOSE INSULATION

  • Choi, Jeong-Hwa;Kim, Hong;Ryu, Kyong-Ok
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.185-192
    • /
    • 1997
  • The combustion of cellulose insulation treated with Borax, Boric acid and Aluminum Sulfate as combustion retardants is examined by candle type combustion tester. The cellulose fibers in cellulose insulation are classified by diameter as less than 0.2mm, 0.2mm-0.5mm, 0.5mm-2mm and more than 2mm. The burning behavior of cellulose insulation are studied by LOI (Limit Oxygen Index: Beginning point of smoldering), L- point (Lower point of combustion transition from smoldering- flaming to flaming combustion), LOI, L-point and H-point rise with the increasing particle size of cellulose fibers because thermal decomposition rate of cellulose fiber decreases. The phenomena of combustion transition from smoldering to flaming combustion are determined by the generating rate of combustible gas and the formation rate of combustible gas mixture within the zone of cellulose fiber heated.

  • PDF

Physical and Mechanical Properties and Fire-endurance Characteristics of Recycled Particleboards

  • Suh, Jin-Suk;Han, Tae-Hyung;Park, Joo-Saeng;Park, Jong-Young
    • Journal of the Korea Furniture Society
    • /
    • v.19 no.6
    • /
    • pp.475-486
    • /
    • 2008
  • In this study, fire-retardant chemicals were melt with mixed composition ratios of dibasic ammonium phosphate and each half of boric acid and borax in hot water, in which hammer-milled chips were immersed to increase swelling of waste particleboards. Also, fire-retardant treated particles from sawn lumber chip and recycled particleboard chip were composed in ratio of 70:30 in core layer to improve boards' properties. Retention ratio of fire-retardant chemicals for the particles for face layer was high due to high specific surface area, and that of sawn lumber chips was somewhat higher than that of recycled particleboard chips. The mixture of particles from sawn lumber chips and recycled PB of 70:30 in weight ratio exceeded bending strength of 100 $kgf/cm^2$. It seemed that the relatively greater portions of dibasic ammonium phosphate affected adversely to dimensional stability, however fire-retardants treatment resulted in distinct effect lowering formaldehyde emission such as $E_0$ type(0.5mg/$\ell$ or less) in KS F 3104. In fire-retardancy, the recycled boards with a mixed ratio of dibasic ammonium phosphate to boric acid borax(50:50 mixture) of 70% to 30% in weight satisfied fire-retardancy 3rd grade in KS F 2271, and also this composition from cone calorimeter test met same standard grade figuring total heat release of 4.6MJ/$m^2$.

  • PDF

Fire Performance Testing Method for Fire Retardant EPS Sandwich Panel Using X-ray Analysis (X-선 분석법을 이용한 난연 EPS 샌드위치 패널의 화재성능평가 방법에 관한 연구)

  • Shim, Ji-Hun;Cho, Nam-Wook
    • Fire Science and Engineering
    • /
    • v.29 no.6
    • /
    • pp.76-83
    • /
    • 2015
  • EPS sandwich panel contains flame retardants that slow down ignition during fires,reduce the amount of heat generated, and block the spread of combustion. However, if a sandwich panel does not satisfy standards for fire-retardant performance, it may increase damage to property and human life. It is difficult to test the fire-retardant performance of a finishing material with the naked eye, so it is necessary to develop convenient and fast evaluation methods that are convenient and fast. In this study, a fire safety evaluation method for EPS sandwich panel was analyzed using X-ray to detect specific components related to the fire-retardant performance X-ray fluorescence analysis (XRF) indicated that suitable panel products contained more aluminum in comparison to unsuitable products. Gibbsite was identified as the main crystalline material of flame retardant EPS through X-ray diffraction analysis (XRD) and was included in both suitable products and unsuitable products, but there was a difference in crystalline structure. This study was verifies the possibility of evaluating fire-retardant performance using ultimate analysis and crystal analysis through these X-ray methods.

Combustion Characteristics of Cypress Specimens Painted with Solutions of Boron Compounds (붕소 화합물로 처리된 편백나무 시험편의 연소특성)

  • Chung, Yeong-Jin;Jin, Eui
    • Fire Science and Engineering
    • /
    • v.32 no.2
    • /
    • pp.1-6
    • /
    • 2018
  • The combustion characteristics of cypress wood coated with boric acid (BA) and ammonium pentaborate (APB) were examined using a cone calorimeter according to the ISO 5660-1 standard. As a result, the combined specimens of boric acid and ammonium pentaborate (BA/APB) led to an improved fire performance index due to their synergistic effect. In addition, the total heat release values of the specimen coated with the boron compounds were 6.1~14.1% lower than that of the base specimen. The total smoke release rate (TSR) of the specimens coated with the boron compound decreased throughout the combustion process, except for BA/APB. The maximum concentration of carbon monoxide was reduced by 15.8~25.5%. In general, wood treated with flame retardants has a lower fire hazard.

Study on the Excellent Heat Resistance Organic-Inorganic Hybrid Flame Retardant (내열성이 우수한 유-무기 하이브리드 방염제에 관한 연구)

  • Cho, Kyeong-Rae;Lee, Sung-Eun;Lee, Chun-Ha;Kim, Si-Kuk
    • Fire Science and Engineering
    • /
    • v.30 no.3
    • /
    • pp.67-72
    • /
    • 2016
  • The development of flame retardants aims to prevent the spread of fire and reduce the casualties caused by flammable and toxic gases generated during the combustion of building materials used in the interiors of multi-use facilities. Flame material application provides flame resistance to a silica sol in an organic-inorganic hybrid material by flame retardant adhesive or coating by producing a sol-gel method. The conventional flame retardant materials, non-flame retardant material is applied with Halogen freeway. In particular, the basic physical properties of conventional adhesive coating improves the heat resistance, enhances the durability fire and heat, and expands the halogen free flame retardant of building materials.