• Title/Summary/Keyword: Fire response

Search Result 602, Processing Time 0.17 seconds

An Analysis for the Educational Training Program of Seoul Fire Academy through AHP (AHP를 이용한 서울특별시소방학교 교육훈련프로그램 분석)

  • Kim, Jin Keun;Park, Chan Seok
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.3
    • /
    • pp.121-132
    • /
    • 2014
  • In recent years, the surroundings of Fire have rapidly changed and citizens need for Fire have been demanding very high. Under these situations, in order for satisfaction to all these demands, Seoul Metropolitan Government Fire Academy(SFA) have only to improve its educational training program as the fire educational training center in Korea. The purpose of this study is to scrutinize current educational training program of SFA and measure the relative weight among the hierarchy of disaster management(prevention and mitigation-preparedness-response-recovery) by using the Analytic Hierarchy Process(AHP). The result of this study presents that how many hours must be allocated and set the educational training program with scientific and systematic way of AHP compared the current program of SFA in 2013. And This study is applied to increase access and comprehension about the AHP and will be able to present guideline for the selection of optimal the educational training of SFA to serve Seoul citizens the best Fire services.

Large scale fire test on a composite slim-floor system

  • Bailey, C.G.
    • Steel and Composite Structures
    • /
    • v.3 no.3
    • /
    • pp.153-168
    • /
    • 2003
  • This paper discusses the results and observations from a large-scale fire test conducted on a slim floor system, comprising asymmetric beams, rectangular hollow section beams and a composite floor slab. The structure was subjected to a fire where the fire load (combustible material) was higher that that found in typical office buildings and the ventilation area was artificially controlled during the test. Although the fire behaviour was not realistic it was designed to follow as closely as possible the time-temperature response used in standard fire tests, which are used to assess individual structural members and forms the bases of current fire design methods. The presented test results are limited, due to the malfunction of the instrumentation measuring the atmosphere and member temperatures. The lack of test data hinders the presentation of definitive conclusions. However, the available data, together with observations from the test, provides for the first time a useful insight into the behaviour of the slim floor system in its entirety. Analysis of the test results show that the behaviour of the beam-to-column connections had a significant impact on the overall structural response of the system, particularly when the end-plate of one of the connections fractured, during the fire.

Numerical analysis of simply supported two-way reinforced concrete slabs under fire

  • Wenjun Wang;Binhui Jiang;Fa-xing Ding;Zhiwu Yu
    • Computers and Concrete
    • /
    • v.31 no.6
    • /
    • pp.469-484
    • /
    • 2023
  • The response mechanism of simply supported two-way reinforced concrete (RC) slabs under fire was numerically studied from the view of stress redistribution using the finite element software ABAQUS. Results show that: (1) Simply supported two-way RC slabs undergo intense stress redistribution, and their responses show four stages, namely elastic, elastic-plastic, plastic and tensile membrane stages. There is no cracking in the fire area of the slabs until the tensile membrane stage. (2) The inverted arch effect and tensile membrane effect improve the fire resistance of the two-way slabs. When the deflection is L/20, the slab is in an inverted arch effect state, and the slab still has a good deflection reserve. The deformation rate of the slab in the tensile membrane stage is smaller than that in the elastic-plastic and plastic stages. (3) Fire resistance of square slabs is better than that of rectangular slabs. Besides, increasing the reinforcement ratio or slab thickness improves the fire resistance of the slabs. However, an increase of cover thickness has little effect on the fire resistance of two-way slabs. (4) Compared with one-way slabs, the time for two-way slabs to enter the plastic and tensile cracking stage is postponed, and the deformation rate in the plastic and tensile cracking stage is also slowed down. (5) The simply supported two-way RC slabs can satisfy with the requirements of a class I fire resistance rating of 90 min without additional fire protection.

A Study on the Response Characteristics Depending on Service Life of Ionization Smoke Detector (이온화식연기감지기의 사용기간에 따른 응답특성 연구)

  • Baek, Won-Don;Kim, Shi-Kuk;Ok, Kyung-Jea;Lee, Chun-Ha;Jee, Seung-Wook
    • Fire Science and Engineering
    • /
    • v.22 no.4
    • /
    • pp.61-64
    • /
    • 2008
  • This paper studied on the response characteristics depending on service life of ionization smoke detector. The experimental samples used ionization smoke detectors (360 EA) for over 5 years which were influenced by environment set up with fire objects. The experimental method performed operate and non-operate test according to 'Type Approval and Technical Regulation of Detector (KOFEIS 0301)', for estimate the response characteristics of ionization smoke detector depending on service life. The results showed that their response characteristics were rapidly decreasing when the longer their using period. Accordingly, it is desirable that ionization smoke detector has to be changed for early fire detection when passed their service life.

A Study on Response Characteristics of ionization Smoke Detector Influenced by Air Stream (이온화식 연기감지기의 기류응답특성 연구)

  • 이복영;정길순;이병곤
    • Fire Science and Engineering
    • /
    • v.17 no.2
    • /
    • pp.6-9
    • /
    • 2003
  • Recently, forced ventilating air conditioning system has been widely used in modern buildings. However, It is obvious that this kind of system may affect on the response of fire detectors at real fire incidents, especially, on the ionization smoke detector, which is critically influenced by air stream. Therefore we studied to verify the response characteristics of air stream by ionization smoke detector for the design of facilities in practice. In this study, experiments were executed to examine the correlation between air velocity and the ionization detector's responses with var-ious air velocity and smoke densities in the simulated test room. As a result of experiments, ionization detector's operating time is in reverse proportion to air velocity. And the detector shows more sensitive reaction when the velocity of smoke stream increase over 60 cm/s. In addition, it was shown that ionization smoke detector is more sensitive to smoldering fires in paper than that in petro-chemicals.

Analysis of Gyeonggi-do 911 emergency cases to identify emergency vulnerable area using clustering analysis (군집분석을 통한 응급취약지역의 유형화와 유형별 대응방안 제안: 경기도 119 구급사건 데이터를 기반으로)

  • Kim, Mirae;Kwon, Uijun;Geum, Youngjung
    • Journal of the Korea Management Engineers Society
    • /
    • v.23 no.4
    • /
    • pp.1-18
    • /
    • 2018
  • Emergency response has been considered as an important task in practice, because it is directly associated with the survival of patients. However, it is very difficult to increase the number of fire stations due to the budget and efficiency problem. Under this circumstances, it is critical to consider the suitability of current arrangement for 911 fire station. This is especially true in Gyeonggi-Do where the characteristics of each sub-area are different. In response, this study aims to identify types of areas that are vulnerable for emergency situations, and try to find relevant solutions for each type. For this purpose, we collected 151,463 data for emergency declaration data which exceeds 10 minutes for its response. Total 19 clustering variables which are used as input variables are selected, considering the characteristics of each area. As a result of clustering analysis, three clusters are identified and analyzed. Finally, areas whose emergence response time is in top 10% are selected and analyzed. This paper is expected to find current issues and problems of emergency response for each area, and help to understand and solve the problem for the local government.

A Study on the Response Characteristics of the Wireless Fire Detector Depending on the Wall Types (벽체 종류에 따른 무선화재감지기의 응답특성에 관한 연구)

  • SaKong, Seong-Ho;Kim, Si-Kuk;Lee, Chun-Ha;Kim, Hyeong-Gweon
    • Fire Science and Engineering
    • /
    • v.25 no.4
    • /
    • pp.82-88
    • /
    • 2011
  • In this paper, an experiment was performed to confirm the effectiveness and the reliability of the wireless fire detector with a 2.4 GHz wireless module which is widely used for commercial purpose. It was the experiment of transmitted waves of wireless signals using samples of typical obstacles such as walls which may affect the wireless communication environment in the building. The experiment results show that the transmitted signal had differences in the response characteristics by wall types.

THE DEVELOPMENT OF A UV FLAME DETECTOR FOR THE AUTOMATIC FIRE SUPPRESSION SYSTEM FOR ENGINE COMPARTMENT FIRES

  • Lim, Sung-Mook;Jung, Ki-Chang;Kim, Eung-Sik;Kim, Hong
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 1997.11a
    • /
    • pp.590-597
    • /
    • 1997
  • In this work, a new type of UV flame detection system was developed. In order to measure the performance of UV flame detector, various kinds of experiments was performed. The results show that the maximum response time of the UV flame detector is 0.2 seconds when the detection distance is one meter The advantages of this system include wide area, high speed response and high sensitivity. After testing the W flame detector in engine compartment it detected fire within 0.09 seconds and extinguished within 5 seconds. Hence, the UV flame detector can be applied in automatic fire suppression system for automobiles.

  • PDF