• Title/Summary/Keyword: Fire rating

Search Result 102, Processing Time 0.024 seconds

Rating Evaluation of Fire Risk for Combustible Materials in Case of Fire (화재 시 연소성 물질에 대한 화재 위험성 등급 평가)

  • Chung, Yeong-Jin;Jin, Eui
    • Applied Chemistry for Engineering
    • /
    • v.32 no.1
    • /
    • pp.75-82
    • /
    • 2021
  • This study investigated the fire risk assessment of woods and plastics for construction materials, focusing on the fire performance index-III (FPI-III), fire growth index-III (FGI-III), and fire risk index-IV (FRI-IV) by a newly designed method. Japanese cedar, red pine, polymethylmethacrylate (PMMA), and polyvinyl chloride (PVC) were used as test pieces. Fire characteristics of the materials were investigated using a cone calorimeter (ISO 5660-1) equipment. The fire performance index-III measured after the combustion reaction was found to be 1.0 to 15.0 with respect to PMMA. Fire risk by fire performance index-III increased in the order of PVC, red pine, Japanese cedar, and PMMA. The fire growth index-III was found to be 0.5 to 3.3 based on PMMA. Fire risk by fire growth index-III increased in the order of PVC, PMMA, red pine, and Japanese cedar. COpeak concentrations of all specimens were measured between 106 and 570 ppm. In conclusion, it is understood that Japanese cedar with a low bulk density and PMMA containing a large amount of volatile organic substances have a low fire performance index-III and high fire growth index-III, and thus have high fire risk due to fire. This was consistent with the fire risk index-IV.

Case Study on the Analysis of Disaster Vulnerabilities (Focused on the Fire & Explosion in the N-Industrial Complex) (재난 취약성 분석에 관한 사례연구(N공단의 화재·폭발을 중심으로))

  • Ha, Kag Cheon
    • Journal of the Korean Society of Safety
    • /
    • v.36 no.2
    • /
    • pp.94-100
    • /
    • 2021
  • In general, the industrial complex is a place where factories of various industries are concentrated. It is only as efficient as it is designed. However, the risks vary as there are various industries. These features are also associated with various types of disasters. The dangers of natural disasters such as a typhoon, flood, and earthquake, as well as fire and explosions, are also latent. Many of these risks can make stable production and business activities difficult, resulting in massive direct and indirect damage. In particular, decades after its establishment, the vulnerabilities increase even more as aging and small businesses are considered. In this sense, it is significant to assess the vulnerability of the industrial complex. Thus analysing fire and explosion hazards as stage 1 of the vulnerability evaluation for the major potential disasters for the industrial complex. First, fire vulnerabilities were analyzed quantitatively. It is displayed in blocks for each company. The assessment block status and the fire vulnerability rating status were conducted by applying the five-step criteria. Level A is the highest potential risk step and E is the lowest step. Level A was 11.8% in 20 blocks, level B was 22.5% in 38 blocks, level C was 25.4% in 43 blocks, level D was 26.0% in 44 blocks, and level E was 14.2% in 24 blocks. Levels A and B with high fire vulnerabilities were analyzed at 34.3%. Secondly, the vulnerability for an explosion was quantitatively analyzed. Explosive vulnerabilities were analyzed at 4.7% for level A with 8 blocks, 3.0% for level B with 5, 1.8% for level C with 3, 4.7% for level D with 8, and 85.8% for level E with 145. Levels A and B, which are highly vulnerable to explosions, were 7.7 %. Thirdly, the overall vulnerability can be assessed by adding disaster vulnerabilities to make future assessments. Moreover, it can also assist in efficient safety and disaster management by visually mapping quantified data. This will also be used for the integrated control center of the N-Industrial Complex, which is currently being installed.

Simulation of Wood Crib Burning Behaviors by Using FDS (FDS를 이용한 소화모형 화재거동의 시뮬레이션)

  • Kwon, Seong-Pil;Yoon, Hun-Ju;Kim, Hyeong-Gweon;Ra, Yong-Woon;SaKong, Seong-Ho;Shin, Dong-Il
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.76-79
    • /
    • 2008
  • In this work wood crib burning behaviors have been simulated by using the FDS(Fire Dynamic Simulator) program. Wood cribs are regularly stacked arrays of wood sticks, and available for the performance rating of fire-extinguishers. On the basis of an angle iron supporter 26 layers of wood sticks have been stacked up. Each layer consists of 5 or 6 wood sticks which are placed in parallel, with a constant distance, and in alternating rows. They are laid between the horizontally adjacent sticks at the before last layer. The wood crib is ignited instantaneously by an amount of burning gasoline below. A comprehensive simulation of such a practical sophisticated combustion is still too difficult to realize with any currently available computer, although the performance of modern processors is getting better everyday. We could carry it out here through parallel computing on the HPC(High Performance Computing) cluster as the feasible alternative. At last the validation has been executed by means of temperature distribution data measured by the thermal video camera.

  • PDF

A Study on the Seismic Design for Water Exthinguishing Piping Systems (수계 파이프 시스템의 내진설계에 관한 연구)

  • Lee, Dong-Myung
    • Fire Science and Engineering
    • /
    • v.22 no.1
    • /
    • pp.10-15
    • /
    • 2008
  • In this study, seismic design in sprinkler head pipeline of water extinguishing system has been carried out. This study describes a generation of artificial earthquake wave compatible with seismic design spectrum, and also analyzed the dynamic response spectra by the simulated earthquake motion. This study constructed powerful engineering base for seismic design, and presented seismic design techniques of water and gas extinguishing piping system. Also, this study readied basis that can apply seismic design and performance estimation of fire fighting system and performance rating as well as pipeline of water extinguishing system from result of this research. Hereafter, if additional research by earthquake magnitude and ground kind is approached, reliance elevation, safety raising and performance based design of fire fighting system see to achieve.

Developing Fire-Danger Rating Model (산림화재예측(山林火災豫測) Model의 개발(開發)을 위(爲)한 연구(硏究))

  • Han, Sang Yeol;Choi, Kwan
    • Journal of Korean Society of Forest Science
    • /
    • v.80 no.3
    • /
    • pp.257-264
    • /
    • 1991
  • Korea has accomplished the afforestation of its forest land in the early 1980's. To meet the increasing demand for forest products and forest recreation, a development of scientific forest management system is needed as a whole. For this purpose the development of efficient forestfire management system is essential. In this context, the purpose of this study is to develop a theoretical foundation of forestfire danger rating system. In this study, it is hypothesized that the degree of forestfire risk is affected by Weather Factor and Man-Caused Risk Factor. (1) To accommodate the Weather Factor, a statistical model was estimated in which weather variables such as humidity, temperature, precipitation, wind velocity, duration of sunshine were included as independent variables and the probability of forestfire occurrence as dependent variable. (2) To account man-caused risk, historical data of forestfire occurrence was investigated. The contribution of man's activities make to risk was evaluated from three inputs. The first, potential risk class is a semipermanent number which ranks the man-caused fire potential of the individual protection unit relative to that of the other protection units. The second, the risk sources ratio, is that portion of the potential man-caused fire problem which can be charged to a specific cause. The third, daily activity level is that the fire control officer's estimate of how active each of these sources is, For each risk sources, evaluate its daily activity level ; the resulting number is the partial risk factor. Sum up the partial risk factors, one for each source, to get the unnormalized Man-Caused Risk. To make up the Man-Caused Risk, the partial risk factor and the unit's potential risk class were considered together. (3) At last, Fire occurrence index was formed fire danger rating estimation by the Weather Factors and the Man-Caused Risk Index were integrated to form the final Fire Occurrence Index.

  • PDF

Development of the National Integrated Daily Weather Index (DWI) Model to Calculate Forest Fire Danger Rating in the Spring and Fall (봄철과 가을철의 기상에 의한 전국 통합 산불발생확률 모형 개발)

  • Won, Myoungsoo;Jang, Keunchang;Yoon, Sukhee
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.20 no.4
    • /
    • pp.348-356
    • /
    • 2018
  • Most of fires were human-caused fires in Korea, but meteorological factors are also big contributors to fire behavior and its spread. Thus, meteorological factors as well as topographical and forest factors were considered in the fire danger rating systems. This study aims to develop an advanced national integrated daily weather index(DWI) using weather data in the spring and fall to support forest fire prevention strategy in South Korea. DWI represents the meteorological characteristics, such as humidity (relative and effective), temperature and wind speed, and we integrated nine logistic regression models of the past into one national model. One national integrated model of the spring and fall is respectively $[1+{\exp}\{-(2.706+(0.088^*T_{mean})-(0.055^*Rh)-(0.023^*Eh)-(0.014^*W_{mean}))\}^{-1}]^{-1}$, $[1+{\exp}\{-(1.099+(0.117^*T_{mean})-(0.069^*Rh)-(0.182^*W_{mean}))\}^{-1}]^{-1}$ and all weather variables significantly (p<0.01) affected the probability of forest fire occurrence in the overall regions. The accuracy of the model in the spring and fall is respectively 71.7% and 86.9%. One integrated national model showed 10% higher accuracy than nine logistic regression models when it is applied weather data with 66 random sampling in forest fire event days. These findings would be necessary for the policy makers in the Republic of Korea for the prevention of forest fires.

Effect of tunnel fire: Analysis and remedial measures

  • Choubey, Bishwajeet;Dutta, Sekhar C.;Kumar, Virendra
    • Structural Engineering and Mechanics
    • /
    • v.80 no.6
    • /
    • pp.701-709
    • /
    • 2021
  • The paper aims at improving the understanding and mitigating the effects of tunnel fires that may breakout due to the burning fuel and/or explosion within the tunnel. This study particularly focuses on the behavior of the commonly used horse shoe geometry of tunnel systems. The problem has been obtained using an adequate well-established program incorporating the Lagrangian approach. A transient-thermo-coupled static structural analysis is carried out. The effects of radiation and convection to the outer walls of the tunnel is studied. The paper also presents the impact of the hazard on the structural integrity of the tunnel. A methodology is proposed to study the tunnel fire using a model which uses equivalent steel sheet to represent the presence of reinforcements to improve the computational efficiency with adequate validation. A parametric study has been carried out and the effect of suitable lining property for mitigating the fire hazard is arrived at. Detailed analysis is done for the threshold limits of the properties of the lining material to check if it is acceptable in all aspects for the integrity of the tunnel. The study may prove useful for developing insights for ensuring tunnel fire safety. To conduct such studies experimentally are tremendously costly but are required to gain confidence. But, scaled models, as well as loading and testing conditions, cannot be studied by many trials experimentally as the cost will shoot up sharply. In this context, the results obtained from such computational studies with a feasible variation of various combinations of parameters may act as a set of guidelines to freeze the adequate combination of various parameters to conduct one or two costly experiments for confidence building.

Fire Risk Rating Evaluation of Organic Insulation Materials (유기 단열재의 화재위험성 등급 평가)

  • You, Ji Sun;Jeon, Nam;Chung, Yeong-jin
    • Applied Chemistry for Engineering
    • /
    • v.32 no.4
    • /
    • pp.417-422
    • /
    • 2021
  • In this study, poly isocyanurate foam (PIR), poly urethane foam (PUR), and phenol foam (PF) of organic insulation materials were selected, and investigated using a cone calorimeter, as per ISO 5660-1. Standard materials (PMMA) were used to standardize the fire hazard assessment, and the fire risk was classified and evaluated by Chung's equations-III and IV. The fire performance index-II value of Chung's equations-II was the highest value with PF of 14.77 s2/kW. And the PUR was 0.08 s2/kW, the lowest value of fire performance index-II value. The fire growth index-II value was the lowest value with PF of 0.01 kW/s2. And the PUR was 1.14 kW/s2, the highest value of fire growth index-II value. The fire performance index-III (FPI-III) of Chung's equations-III had the lowest value for PUR (0.11) and the highest for PF (20.23). The PUR showed the highest value of the fire growth index-III (FGI-III) as 14.25, while the PF exhibited 0.13 regarded as the safest materials. The fire risk index-IV (FRI-IV) value of Chung's equation-IV was in the following order: PUR (130.03) >> PIR (19.13) > PMMA (1.00) > PF (0.01). Therefore, it was concluded that the fire risk associated with PF is the lowest, whereas that associated with PUR is the highest.

Development of New Algorithm for Maximum Power Point Tracking of Photovoltaic system (Photovoltaic 시스템의 MPPT를 위한 새로운 알고리즘 개발)

  • Park, Ki-Tae;Ko, Jae-Sub;Choi, Jung-Sik;Park, Byung-Sang;Chung, Dong-Hwa
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.10 no.1
    • /
    • pp.87-95
    • /
    • 2007
  • This paper is proposed a novel method to approximate the maximum power for a photovoltaic inverter system and tracking method. It is designed for power systems application and utilities. The proposed Maximum Power Point Tracking (MPPT) control has the advantage to provide a new simple way to approximate the optimal or rated voltage, the optimal or rated current and maximum power rating produced by a solar panel and the photovoltaic inverter. And this straightforward method will be named linear reoriented coordinates method (LRCM) with the advantage that Pmax and $V_{op}$ can be approximated using the same variable as the dynamic model without using complicate approximations or Taylor series. Furthermore tracking method is improved over 50% photovoltaic efficiency. This paper is proposed MPPT using LRMC and tracking method using weather condition of domestic moderate program technique. This paper is proposed the experimental results to verify the effectiveness of the new methods.

  • PDF

Developing Forest Fire Occurrence Probability Model Using Meteorological Characteristics (기상자료(氣象資料)를 이용(利用)한 산불발생확률모형(發生確率模型)의 개발(開發))

  • Choi, Kwan;Han, Sang Yoel
    • Journal of Korean Society of Forest Science
    • /
    • v.85 no.1
    • /
    • pp.15-23
    • /
    • 1996
  • Preparing the era of forest resources management requires studies on forest fire. This study attempted to develop forest fire occurrence model using meteorological characteristics for the practical purposes of forecasting forest fire danger rate. To accomplish this goal, the relationships between forest fire occurrence and meteorological characteristics are estimated. In the process, the forest fire occurrence pattern of the study region(Taegu-Kyungpook) is categorized by employing qualification IV method. The study region was divided into three areas such as, Taegu, Andong and Pohang area. The meteorological variables emerged as affective to forest fire occurrence are relative humidity, longitude of sunshine, and duration of precipitation. To estimate the probability of forest fire danger, forest fire occurrence of three areas are regressed on the time series data of affective meteorological variables using logistic and probit model. The effectiveness of the models estimated are tested and showed acceptable degree of goodness. Those models developed would be helpful to increase the efficiency of forest fire management such as detection of forest fire occurrence and effective disposition of forest fire fight equipments.

  • PDF