• Title/Summary/Keyword: Fire protection safety

Search Result 634, Processing Time 0.029 seconds

Proposal of Analyis Method for PICV Characteristics Curve Using CFD in Hydronic System (밀폐형 수배관시스템에서 CFD를 활용한 복합밸브 특성곡선 해석 방법 제안)

  • Do, Gahyeon;Kim, Jinho;Park, Woopyeng;Min, Joonki
    • Journal of the Korean Society for Geothermal and Hydrothermal Energy
    • /
    • v.17 no.2
    • /
    • pp.20-29
    • /
    • 2021
  • In this study, it is proposed that an analysis method using charatersistics curve of PICV in the CFD simulation for hydronic system. From the results, the pressure drop characteristics appeared in the region of PICV at a specified flow rate. And the CFD results are in good agreement with the experimental results. Proposed analysis method is proved that the characteristics of PICV applied to the hydronic system were properly applied in the flow analysis. This result can be applied to PICV in the complex hydronic systems. Therefore, the optimal selection of PICV in hydronic system contribute the building energy saving.

Design of Personal Information Security Model in U-Healthcare Service Environment (유헬스케어 서비스 환경 내 개인정보 보호 모델 설계)

  • Lee, Bong-Keun;Jeong, Yoon-Su;Lee, Sang-Ho
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.11
    • /
    • pp.189-200
    • /
    • 2011
  • With rapid development and contribution of IT technology IT fushion healthcare service which is a form of future care has been changed a lot. Specially, as IT technology unites with healthcare, because delicate personal medical information is exposed and user's privacy is invaded, we need preperation. In this paper, u-healthcare service model which can manage patient's ID information as user's condition and access level is proposed to protect user's privacy. The proposed model is distinguished by identification, certification of hospital, access control of medical record, and diagnosis of patient to utilize it efficiently in real life. Also, it prevents leak of medical record and invasion of privacy by others by adapting user's ID as divided by user's security level and authority to protect privacy on user's information shared by hospitals.

Study on the Chemical Management - 1. Chemical Characteristics and Occupational Exposure Limits under Occupational Safety and Health Act of Korea (화학물질 관리 연구-1. 산업안전보건법상 관리 화학물질의 특성과 노출기준 비교)

  • Park, Jihoon;Ham, Seunghon;Kim, Sunju;Lee, Kwonseob;Ha, Kwonchul;Park, Donguk;Yoon, Chungsik
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.25 no.1
    • /
    • pp.45-57
    • /
    • 2015
  • Objectives: This study aims to compare the physicochemical characteristics, toxicological data with Occupational Exposure Limits (OELs) of chemicals under the Occupational Safety and Health Act(OSHA) regulated by the Ministry of Employment and Labor of Korea. Methods: Information on chemicals which have OELs on physicochemical characteristics and toxicological data was collected using Material Safety Data Sheet(MSDS) from Korea Occupational Safety and Health Agency(KOSHA) and the Korea Information System for Chemical Safety Management(KISChem) in 2014. Statistical analyses including correlation and simple regression were performed to compare the OELs with chemical characteristics including molecular weight, boiling point, odor threshold, vapor pressure, vapor density, solubility and octanol-water partition coefficient(OWPC) and toxicological data such as median lethal dose($LD_{50}$) and median lethal concentration($LC_{50}$). Results: A total of 656 chemicals have OELs under OSHA in Korea. The numbers of chemicals which have eight-hour time weighted average(TWA) and short term exposure limits(STEL) are 618 and 190, respectively. TWA was significantly correlated with boiling point and STEL was only correlated with vapor pressure among physicochemical characteristics. Solubility and OWPC between "skin" and "no skin" substances which indicate skin penetration were not significantly different. Both $LD_{50}$ and $LC_{50}$ were correlated with TWA, while the $LC_{50}$ was not with STEL. As health indicators, health rating and Emergency Response Planning Guidelines(ERPG) rating as recommended by the National Fire Protection Association(NFPA) and American Industrial Hygiene Association(AIHA) were associated with OELs and reflect the chemical hazards. Conclusions: We found relationships between OEL and chemical information including physicochemical characteristics and toxicological data. The study has an important meaning for understanding present regulatory OELs.

A Study on the Determining Factors For Assessment Criteria of Project Performance Capability of CM(Construction Management) Considering Safety (안전을 고려한 건설사업관리용역업자(CM) 사업수행능력 평가기준 요인 도출 연구)

  • Kim, Do-Su;Kim, Baek-Joong;Shin, Yoon-Seok
    • Journal of the Korea Institute of Building Construction
    • /
    • v.19 no.6
    • /
    • pp.557-566
    • /
    • 2019
  • The construction industry has the most safety accidents of any of the domestic industries. Special care must be taken because disasters in the construction industry lead to social problems caused by huge property losses and casualties. As a result, there is a growing awareness of disasters occurring in the construction industry, and government departments are tightening their regulations on safety management. In particular, the OSHA (Occupational Safety and Health Agency) focuses on the expansion of protection targets and the clarification of responsibility in the full amendment OSHA. As a result, a study that focuses on the client's responsibility for safety management is needed. In this study, the project performance capability assessment of construction project management contractors, which is being carried out with uniform assessment criteria without considering the characteristics of the construction project, is considered and all the amendments to the OSHA are considered, and the factors were derived for improvement measures.

Seismic Performance and Damage Prediction of Existing Fire-protection Pipe Systems Installed in RC Frame Structures (철근콘크리트 구조물 내 부착된 수계 관망시스템의 내진거동 및 손상예측)

  • Jung, Woo-Young;Ju, Bu-Seog
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.15 no.3
    • /
    • pp.37-43
    • /
    • 2011
  • Reliability of piping systems is essential to the safety of any important industrial facilities. During an earthquake, damage to the piping system can occur. It can also cause considerable economic losses and the loss of life following earthquakes. Traditionally, the study of the secondary system was less important than primary structure system, however it has recently been emerging as a key issue for the effective maintenance of the structural system and to help reduce nonstructural earthquake damage. The primary objectives of this study are to evaluate seismic design requirements and the seismic performance of gas and fire protection piping systems installed in reinforced concrete (RC) buildings. In order to characterize the seismic behavior of the existing piping system in an official building, 10 simulated earthquakes and 9 recorded real earthquakes were applied to ground level and the building system by the newmark average acceleration time history method. The results developed by this research can be used for the improvement of new seismic code/regulatory guidelines of secondary systems as well as the improvement of seismic retrofitting or the strengthening of the current piping system.

The implementation of Smart Care System for Dementia Patients (치매 환자를 위한 스마트 캐어 시스템 구현)

  • Ha, Eun-Sil
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.6
    • /
    • pp.3832-3840
    • /
    • 2014
  • The rapidly aging population is also increasing the number of dementia patients rapidly. Studies have revealed the early signs of slowing progress. Therefore, dementia patient safety, continuous care, daily living, and health care are becoming more important. In this paper, a smart home care system using smart phones and Bluetooth communication technology was used to monitor the state of dementia patients of based on the results of grading dementia, health care of the dementia patients at home and provide for the safety of the system using motion sensors and gas leak sensors to respond to various emergency situations, such as fire, gas leak protection, and loitering. Using this system, the patient can stay longer in their home due to the nature of Korean culture before admission, while reducing the family's economical, physical and psychological burden and allowing the consultation of specialists through the system by building a database of individuals and providing professional service and specialty care referral agencies through the link.

Current Status of Tire Recycling in Taiwan

  • Shanshin Ton;Taipau Chia;Lee, Ming-Huang;Chien, Yeh-Chung;Shu, Hung-Yee
    • Proceedings of the IEEK Conference
    • /
    • 2001.10a
    • /
    • pp.230-235
    • /
    • 2001
  • There are more than 15 millions cars or motors in Taiwan. According to the statistics from Environmental Protection Administration, the number of resulting scrap tires are near 110 thousand tons each year. The tire recycle programs in Taiwan were first conducted in 1989 and executed by ROC Scrap Tire Foundation. However, the current efficiency of the tire recycling industry still needs to be improved to minimize the environmental problem or fire hazards caused by scrap tires storage. Ten major tire-recycling factories are surveyed in this study. The investigations include the source of scrap tire, the shredding process, the market of products, the management of wastes disposal, and the difficulties of these sectors. As the varieties of the shredding machines of the recycle factories, there are three kinds of final products which include powder, granular, and chips. The wastes, wires and fibers, produced by the shredding process are the major problems fur all the factories. The percentage of the wire and fiber removal from rubbers still needs to be increased. The best approaches found in this study to increase the efficiency of scrap tire recycling processes are proposed which include the improvement of magnetic separation system fiber/rubber separation system and the minimization of waste disposal. A categorized standard of the processing outputs is suggested as a reference for the decision-making of the tire-recycling factories.

  • PDF

A study on the Effects and Improvements of a Train Drivers' Licensing System (철도기관사 면허제 시행효과 및 개선방안에 관한 연구)

  • Lee, Chan-Bong;Park, Jin-Pyo
    • Journal of the Korean Society for Railway
    • /
    • v.18 no.1
    • /
    • pp.71-80
    • /
    • 2015
  • During normal subway rush hours, a train-driver is in charge of more than 3,000 people on a daily basis. When an emergency event occurs, millions of people and their property come to depend only on the train-driver's ability. After the Daegu subway fire disaster in February 2003, the Railway Safety Act was enacted in October 2004 and the 'Train Drivers' Licensing System' was introduced by the National Railroad Administration in July 2006 to secure and improve protection. This study was conducted to investigate and evaluate the effects of the Train Drivers' Licensing System since the Licensing System was first introduced eight years ago. In addition, the analysis will suggest better policies for the effectiveness of the 'Train Drivers' Licensing System'.

Winter to replace the hydraulic test and pneumatic test comparative analysis of study on the optimal pressure (동절기 수압시험을 대체하는 공기압시험의 적정압력 비교분석에 관한 연구)

  • Kwoun, Young-Hee;Hwang, Dong-Hwan;Kim, Tae-Gil;Kang, Kyung-Sik
    • Journal of the Korea Safety Management & Science
    • /
    • v.16 no.2
    • /
    • pp.211-216
    • /
    • 2014
  • Using a high-rise building water piping after hydrostatic test of the reliability of the leak to be completed if the pressure is maintained until the leak is not commercially available considered. Due to the nature of high-rise buildings and the construction period will take several years from the lower levels of use of the water supply and fire fighting water pipe construction is in progress, the order of which I do most of the first pipe to the construction and more than three years. So kind of riser pipe is complete, install the valve in the basement by installing an automatic pump to maintain a constant pressure after hydrostatic test and after each floor plumbing piping is complete, the progress of the hydrostatic test without undergoing a separate branch pipe the valve is opened automatically when the number of the pressing pressure of the structure. I kind of do and keep working pressure of pipe until the completion of the construction work to keep the damage to human error when it is intended to prepare. In winter, the frost protection and an alternative to drainage water pipe is damaged or deformed, even if unaware of the finishing work to the building, the use of the damage caused by a leak in a after construction of finish work to be expected. Alternative to reduce this damage if the pressure test without fear of freezing to help maintain long-term commercial pressures may be considered.

A Study on the Present Condition and Countermeasure Plan for the Disaster Protection in Public Library of Korea (한국 공공도서관의 재난대비 실태와 대응방안 연구)

  • Kim, Po-Ok
    • Journal of the Korean Society for Library and Information Science
    • /
    • v.40 no.4
    • /
    • pp.85-110
    • /
    • 2006
  • Recently, there have been a number of news reports on natural disasters, like earthquakes. typhoons, floods and tsunami, all over the world. Korea does not seem to be safe from such disasters or terror threats. As places with high numbers of visitors. libraries need to take preventive measures to be prepared for such disasters and threats. This paper analyzes the current status of emergency measures adopted by 75 public libraries in Seoul. Daejeon and Jeonbuk in Korea. For each library surveyed. the causes of and ways to recover from disasters were reviewed and detailed analyses were carried out in low areas: Implementation of preventive measures disaster management and equipment, status of human resources and assignment of people to disaster recovery, safety courses offered to library users and training methods. In addition, each area was analyzed in regard to possible solutions and ideas for improvement, as well as suggestions to upgrade disaster recovery systems in the future.