• Title/Summary/Keyword: Fire protection design

Search Result 332, Processing Time 0.028 seconds

A Study on the design of Unmanned Autonomous Helicopter for Aerial Monitoring and Control of a Large Size Disaster and Forest Fire (대형재난 및 산불 공중지휘통제용 무인자율헬기 개발에 관한연구)

  • Kim, Jong-Kwon;Kwark, Ji-Hyun;Son, Bong-Sei
    • Proceedings of the Korea Institute of Fire Science and Engineering Conference
    • /
    • 2008.11a
    • /
    • pp.105-110
    • /
    • 2008
  • Unmanned helicopter has several abilities such as vertical take off, hovering, low speed flight at a specific altitude. Such vehicles are becoming popular in actual applications such as search and rescue, aerial reconnaissance and surveillance in the case of a large size disaster and forest fire. In this paper, a flight control system was designed for an unmanned helicopter. This paper was concentrated on describing the systematic design, electronic equipments and their interconnections for realizing the autonomous flight and aerial monitoring. A study on the autonomous waypoint navigation and altitude control performance were performed and tested on a test unmanned helicopter and the performance and the feasibility were represented.

  • PDF

A Study on the Survey of Each Country's Standards to Prevent Flashover of Housing Building (주거시설의 플래시오버 방지를 위한 각국의 내장재 기준 조사에 관한 연구)

  • Hun, Ye-Rim;Kim, Yoon-Seong;Lee, Byeong-Heun;Jin, Seung-Heun;Kwon, Young-Jin
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2021.11a
    • /
    • pp.44-45
    • /
    • 2021
  • In Korea, the risk of fire in buildings is increasing. Therefore, efforts are needed to reduce casualties and property damage. Accordingly, it is important to limit the flashover so that the fire inside the building does not expand to the outside. Flashover refers to the generation of upward airflow after the fire in the compartment, and when combustible gas accumulates in the upper part of the fire chamber and reaches about 500℃, explosive expansion combustion occurs inside the compartment. This can suppress flashover due to limitations on building interior materials. To this end, internal limitations are being implemented at home and abroad through standards related to internal materials. In this paper, we intend to secure basic data on domestic fire safety design by comparing domestic and foreign standards and reviewing the Japanese housing interior design manual.

  • PDF

A Study on escape using elevators in fire emergency (화재 시 승강기를 이용한 피난에 관한 연구)

  • Chung, Eui-Soo
    • Proceedings of the Safety Management and Science Conference
    • /
    • 2007.11a
    • /
    • pp.55-68
    • /
    • 2007
  • Because of not accepted on escape using elevators in fire emergency has some background. In the background elevator hoistway has turn into smoke spread route in fire. The escape that used an elevator was not able to make ends meet; of the big confusion is expected that cannot control the escape adequately, and do that elevator facilities breakdown possibility by the fire water, the escaper shut in car. Therefore ban on elevator service in fire time as a general rule. Recently, a few company promote super high-rise architecture in the country, a fire disaster prevention and human life safety measures preparation for PBD(A Performance Based Fire Protection Design) are studied concretely. And there is the escape example in fire time that used an elevator in the foreign country. You must promote it so that the escape measures that used enclosed stairway and an elevator in charge of a function of the mutual supplement. The result of this research can be used for establishing the standard and regulation for using elevators in fire emergency.

  • PDF

Dynamic Response of Drill Floor to Fire Subsequent to Blowout

  • Kim, Teak-Keon;Kim, Seul-Kee;Lee, Jae-Myung
    • Journal of Ocean Engineering and Technology
    • /
    • v.34 no.2
    • /
    • pp.110-119
    • /
    • 2020
  • Explosions and fires on offshore drilling units and process plants, which cause loss of life and environmental damage, have been studied extensively. However, research on drilling units increased only after the 2010 Deepwater Horizon accident in the Gulf of Mexico. A major reason for explosions and fires on a drilling unit is blowout, which is caused by a failure to control the high temperatures and pressures upstream of the offshore underwater well. The area susceptible to explosion and fire due to blowout is the drill floor, which supports the main drilling system. Structural instability and collapse of the drill floor can threaten the structural integrity of the entire unit. This study simulates the behavior of fire subsequent to blowout and assesses the thermal load. A heat transfer structure analysis of the drill floor was carried out using the assessed thermal load, and the risk was noted. In order to maintain the structural integrity of the drill floor, passive fire protection of certain areas was recommended.

Consideration of Pressure-Rise and Water Hammer for Pipe System in Relation to Start-Up and Sudden Stop of the Pump (펌프 기동 및 정지에 따른 배관 압력상승과 수격작용 영향 고찰)

  • Heo, Min Woong;Min, Ji Ho
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.13 no.1
    • /
    • pp.69-74
    • /
    • 2017
  • In the fire protection system or fire fighting water supply system, the jockey pump is generally installed for the prevention of the pressure decrease of pipes, the frequent driving of the fire pump and protection the pipes from the water hammer. In this paper, the pressure-rise in fire fighting water distribution pipes in condition of pipe pressurization by the surge tank at the start-up and the sudden-stop of the fire pump without additional installation of jockey pump is considered by using simple formula calculations and the evaluation of water hammer occurrence in condition of pipe pressurization by the surge tank is included. As a result, the pressure-rise of pipes is less than the pipe design pressure at the condition of pump's start-up and sudden stop, and the possibility of water hammer occurrence is remarkably low due to pressurization of the pipes by the surge tank.

A Study on the Life Risk Assessment of Ship's Engine Room Fire (기관실화재 인명위험성평가에 관한 연구)

  • Han, Sang-Kook;Cho, Dae-Hwan;Park, Chan-Soo
    • Proceedings of KOSOMES biannual meeting
    • /
    • 2006.11a
    • /
    • pp.283-289
    • /
    • 2006
  • This study is a preparation for the application of FSA (Formal Safety Assessment) to the fire safety of ships. FSA is the new-fashioned methodology proposed to prevent ships from the accidents. To make a base of the fire safety assessment about ship's fire protection design and Classification Society rule, statistical informations for the fire safety engineering are investigated. From results, the necessity of new criterion for ship's fire safety design, the need to study the human behavior in the evacuation from fire, and the development of new fire progress model considering special situations in ships are acknowledged.

  • PDF

The Study on the Legal Improvement for Fire Protection in Wooden Architectural Heritage (목조건축 문화재의 화재방호를 위한 법규 개선에 관한 연구)

  • Kim, Dong Cheol;Roh, Sam Kew;Ham, Eun Gu
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.19-26
    • /
    • 2015
  • This study covers securing legal systems and institutions regarding the standards for installing fire prevention facilities to prevent fire on wooden architectural heritage. Conflicts among relevant laws were revealed and problems related to fire prevention performance, technical standards, responsibilities, etc. in the process of establishing legal fire prevention equipment and the equipment for self-extinguishing were identified through pondering over current legal systems of fire prevention facilities. To resolve the problems, at least the principle to preserve original shapes of wooden architectural heritage should be secured even though fire prevention facilities are installed and the installation process should be regulated by laws considering features of fire on wooden architectural heritage so that fire prevention performance can be guaranteed. The directions to improve installing system through legalization of design, construction, and audit review institutions and legalization of the technical standards for fire prevention facilities were suggested to guarantee performance when establishing fire prevention facilities for wooden architectural heritage.

Heat Transfer Characteristics of Bulkhead Penetration Piece for A60 Class Compartment I: Transient Thermal (A60급 구획 적용 격벽 관통용 관의 열전달 특성 I: 관의 설계에 따른 과도 열해석)

  • Park, Woo-Chang;Song, Chang Yong;Na, Ok-Gyun
    • Journal of Ocean Engineering and Technology
    • /
    • v.32 no.5
    • /
    • pp.310-323
    • /
    • 2018
  • In order to protect lives and prevent large-scale injuries in the event of a fire on a ship or an offshore plant, most classification societies are strengthening their fire resistance designs of relevant cargo holds and accommodation compartments to keep flames from being transferred from a fire point to other compartments. Particularly in critical compartments, where flames should not propagate for a certain period of time, such as the A60 class division, both the airtightness and fire-resistant design of a piece passing through a bulkhead are subject to the Safety of Life at Sea Convention (SOLAS) issued by the International Maritime Organization (IMO). In order to verify the suitability of a fire-resistant design for such a penetrating piece, the fire test procedure prescribed by the Maritime Safety Committee (MSC) must be carried out. However, a numerical simulation should first be conducted to minimize the time and cost of the fire resistance test. In this study, transient thermal analyses based on the finite element method were applied to investigate the heat transfer characteristics of a bulkhead penetration piece for the A60 class compartment. In order to determine a rational bulkhead penetration piece design, the transient heat transfer characteristics according to the variation of design parameters such as the diameter, length, and material were reviewed. The verification of the design specification based on a numerical analysis of the transient heat transfer performed in this study will be discussed in the following research paper for the actual fire protection test of the A60 class bulkhead penetration piece.