• Title/Summary/Keyword: Fire protection Facilities

Search Result 194, Processing Time 0.026 seconds

Comparative Analysis of Flame Retardant Performance of Japanese Cypress Plywood Based on the Main Ingredients of Fire Retardant Paint (도료의 주성분에 따른 편백 합판의 방염성능 비교 분석)

  • Soo-Hee Lim;Ha-Sung Kong
    • Journal of the Korea Safety Management & Science
    • /
    • v.25 no.1
    • /
    • pp.61-66
    • /
    • 2023
  • The purpose of this study is to compare and analyze the flame retardant performance of Japanese cypress(Chamaecyparis obtusa) plywood, commonly used in indoor decoration, furniture, and tableware, by treating it with three different fire retardants with different primary ingredients. The experiment was conducted in compliance with Article 31, Paragraph 2 of the Enforcement Decree of the Fire Facilities Installation and Management Act and Articles 4 and 7-2 of the Flame Retardant Performance Standards. After flame time, after glow time, char length, and char area were measured. As a result, first, after flame time was measured at 0 seconds regardless of whether the flame retardant treatment was applied. Second, after glow time was relatively long, measuring 22.7 seconds without treatment, which is likely due to the weak fire resistance and high concentration of carbon monoxide generated by the chemical characteristics of the Japanese cypress itself. Third, it was confirmed that the effects of the primary ingredient, phosphorus, in the flame retardant treatment varied depending on the technological development of the manufacturers of the same species of Japanese cypress plywood. In the future, it is expected that the results of this study will provide fundamental data to select flame retardant treatments that show high flame retardant performance according to the botanical characteristics of the wood.

Methods to Improve the Design of Household Fire Extinguishers through an Empirical Analysis of Consumer Compatibility (소비자의 적합성 실증분석을 통한 가정용 소화기의 디자인 개선방안)

  • Lee, Sung-Woo
    • Fire Science and Engineering
    • /
    • v.34 no.3
    • /
    • pp.58-66
    • /
    • 2020
  • Households are categorized as exceptions in the Fire Services Act; oftentimes, the 'Golden Time' is missed at the early stages of a fire, resulting in loss of life. As such, due to the high number of deaths caused by household fires, the Korean government amended the Fire Services Act to make it mandatory for all detached houses to be equipped with a fire extinguisher from 2017 onwards. Only 34.8% of households were properly equipped with a fire extinguisher, according to the 2018 factual survey on fire extinguishing facilities in households conducted by the Fire Department. Fire extinguishers are crucial in case of fire but many households avoid them because they are red and have a rough aesthetic, which does not suit the household environment. There is now a need for diverse simple fire extinguisher designs so that they can be used as interior décor in the household in the day-to-day while being available for putting out a fire when necessary. If fire extinguishers have designs that go well with any household space like other decorative ornaments, this will greatly increase consumers' motivation to purchase them. It is greatly anticipated that various companies will work on developing designs for fire extinguishers to commercialize them for households in the future.

Investigation on Fire Resistance of High-Performance Cement Motar with Recycled Fine Aggregate Mixed by Two-Stage Mixing Approach (2단계 배합을 사용한 순환잔골재 혼입 고성능 시멘트 모르타르의 내화성능 연구)

  • Park, Sung-Hwan;Choi, Jun-Ho;Lee, Chi Young;Koo, Min-Sung;Chung, Chul-Woo
    • Journal of the Korean Recycled Construction Resources Institute
    • /
    • v.10 no.1
    • /
    • pp.23-29
    • /
    • 2022
  • This study was conducted to confirm the applicability of recycled aggregates as aggregates for structural concrete as a way to respond to the shortage of natural aggregates. The two-stage mixing approach developed by Tam et al. is known to be a method that can improve the mechanical performance of recycled aggregate concrete without the installation of new additional facilities. In this work, modified version of two stage mixing approach, which was used in our earlier work, was introduced to prepare mortar specimens with recycled fine aggregate, and the compressive strength and fire resistance were compared to mortar mixed with normal mixing approach. According to the experimental results from mortar with recycled fine aggregate, the use of two-stage mixing approach was found to be more effective than normal mixing approach for compressive strength development. In addition, the residual strengths of the mortar with two-stage mixing approach was higher than mortar made of normal mixing approach after exposure to 600 and 900 ℃. It is possible to manufacture high-performance cement composites with recycled fine aggregates through the active use of the two-stage mixing approach.

Lightning Protection System of Solar Power Generation Device (태양광발전장치의 낙뢰보호 시스템)

  • Yongho Yoon
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.23 no.2
    • /
    • pp.157-162
    • /
    • 2023
  • Among the failures of photovoltaic power generation facilities, failures caused by surges account for 20% of the total failure rate, and energy emissions of tens to hundreds [A] during power generation and electrical damage to inverters and connection boards lead to electrical safety accidents. In particular, in the case of lightning, an abnormal voltage is induced in an electric circuit to destroy insulation, and the current flowing at this time causes a fire and acts as a factor that accelerates the deterioration of parts. Due to this action, the problem of electrical safety of solar power generation devices spreading from outside the city center to the inside of the city center such as houses, apartments, and government offices is emerging. Since lightning strikes cause both field-based and conducted electrical interference, this effect increases with increasing cable length or conductor loops. In addition, surge damages not only solar modules, inverters and monitoring devices, but also building facilities, which can eventually cause operational shutdown due to fire of the photovoltaic power generation system and consequent financial loss. Therefore, in this paper, a lightning protection system for solar power generation devices is studied for the purpose of reducing property damage and human casualties due to the increase in fire and electrical safety accidents caused by lightning strikes in photovoltaic power generation systems.

A Study on Data Research for Fire Regulations and Fire Retardant in Interior Architecture (실내건축관련 소방(消防)규정과 방염(防炎)에 관한 연구)

  • Cho, Sung-O;Kim, Yong-Sung
    • Korean Institute of Interior Design Journal
    • /
    • v.19 no.3
    • /
    • pp.95-102
    • /
    • 2010
  • Recently, a grow in size and features of Interior construction work over the complex and The Fire-related regulations have been strengthened for the prevention of fire damage. This study is purpose to propose interior design, construction and supervision for the efficient and reasonable way throughout the fire-related laws are investigated in interior architecture. First, the interior of the building work will be based on actual use Fire-related Laws and Regulations have be investigated. Second, based on analysis of material and facilities by Application can be used in production by the data were applied to the present. Third, the international Fire and Flame Retardant Standards for investigating and reviewing the relevant laws, differences and characteristics of each country were analyzed. Fourth, the various fire-related issues of regulation and the application of relevant provisions in the field works, the law's standards, and improvements were identified by analysis. Fire-Related Laws and Building codes that Safety Administration of the Fire Services are divided into design, it comes to approval from the municipal authorities with concerns about the fire that will fit on the Fire Department's administrative procedures and operations is necessary to integrate operations. In conclusion, Fire-related business are divided into Minister of Land, Transport and Maritime Affairs and Ministry of Public Administration and Security. So, Both institutions is need to be the cooperative work. It is necessary to the field supervision. Because, Flame-resistant performance standards in the field works applied are too complex. Last, Establishment of fire-related regulations will enact by private organizations and the experts to participate.

A Study on the Development of a Duct-dedicated Intelligent Fire Detection System (덕트전용 지능형 화재감지시스템 개발에 관한 연구)

  • Kim, Si-Kuk;Lee, Gun-Ho;Lee, Chun-Ha;Lim, Woo-Sub
    • Fire Science and Engineering
    • /
    • v.29 no.4
    • /
    • pp.39-48
    • /
    • 2015
  • This research was done to develop a duct-dedicated intelligent fire detection system to prevent fires and minimize fire damage of the industrial duct having a high fire risk. To understand the fire hazards of the ducts, the analysis was centered on the Daegu Textile Industrial Complex, where industrial ducts are used frequently. With this in the background, dedicated fire detectors and fire alarm control panel, which can prevent fires and to minimize fire damages to the ducts, were designed and produced, after which the performance was confirmed. As a result of performance experiments, it was shown that a duct-dedicated intelligent fire detection system had excellent adaptability and temperature accuracy. Through real-time temperature monitoring of the inside of the ducts, it was confirmed that duct fires could be efficiently extinguished by stepwise control of linkage facilities according to the setting temperature.

A Study on the Efficient Operation of Self-audit in Large-scale PSM Workplace (대규모 PSM 사업장의 자체감사에 대한 효율적 운영 연구)

  • Min, Se-Hong;Kim, Seok-Won
    • Fire Science and Engineering
    • /
    • v.27 no.6
    • /
    • pp.115-121
    • /
    • 2013
  • Industrial facilities are becoming bigger and more up to date, And a kind of the hazardous material used in the industrial filed is diversified. Therefore, serious accidents such as leakage of toxic materials, fire and explosion, is continuously occurred. There is Process Safety Management (PSM) system of the several preventive systems, but it is supposed to be a limitation to ensure safety or huge PSM industrial sites where have potential to catastrophically invisible and unexpected risks because it is still being managed by instruction and inspection of authority having jurisdiction other than self-regulating management differing from the primarily aim of PSM system. To verify safety management system of work-place, supplementation of existing system is urgently required. In this study, it suggests that PSM self-audit be emphasized significantly analyzing problems of the current systems for enhancing self-audit be emphasized significantly analyzing problems of the current systems for enhancing self-control safety through efficient self-audit management and improving the existing system and improving the existing as verifying the system there of, as well as studying methods which can support institutionally.

A Study on the Measurement of Explosion Range by CO2 Addition for the Process Safety Operation of Propylene (프로필렌의 공정안전 운전을 위한 CO2 첨가량에 따른 폭발범위 측정에 관한 연구)

  • Choi, Yu-Jung;Heo, Jong-Man;Kim, Jung-Hun;Choi, Jae-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.20 no.7
    • /
    • pp.599-606
    • /
    • 2019
  • Most facilities that manufacture products made from the hazardous materials operate at high temperatures and pressures. Therefore, there is a risk of fire explosion. In particular, an explosion accident is a major risk factor for facilities with hazardous materials, such as oil, chemical, and gas. Propylene is often used in sites producing basic raw materials and synthetic materials by addition polymerization at petrochemical plants. To prevent an explosion in the business using propylene, the explosion range with the oxygen concentration was calculated according to the changes in temperature and pressure using an inert gas, carbon dioxide. In these measurements, the temperature was $25^{\circ}C$, $100^{\circ}C$, and $200^{\circ}C$ and the amount of carbon dioxide in the container was $1.0kgf/cm^2.G$, $1.5kgf/cm^2.G$, $2.0kgf/cm^2.G$, and $2.5kgf/cm^2.G$. The explosion limit was related to temperature, pressure, and oxygen concentration. The minimum oxygen concentration for an explosion decreased with increasing temperature and pressure. The range of explosion narrowed with decreasing oxygen concentration. In addition, no explosion occurred at concentrations below the minimum oxygen concentration, even with steam and an ignition source of propylene.

A Study on the Development, Performance and Reliability Certification for Fire Detection System in Outdoor Area (옥외형 화재경보시스템의 개발과 성능시험에 관한 연구)

  • Baek, Dong-Hyun;Ghil, Min-Sik
    • Fire Science and Engineering
    • /
    • v.27 no.5
    • /
    • pp.15-18
    • /
    • 2013
  • This paper is concerned with the Performance and Reliability Certification for fire detection system in outdoor area such small and middle sized cultural assets, natural monument and outdoor facilities. Especially, if a fire were to occur in vulnerable area, it is difficulty to detect a fire. therefore we propose a high efficiency and low cost unmanned fire detection system in capable of an early detection regardless spontaneously fire or firebug. for Adoption of Intelligent Fire Detection System with movable and unmanned function breaking from the existing Conventional Fire Detection System, this Range of R&D includes the Performance test, Function test, Field test, Flame Detection test and EMI/EMS Compliance test. the Result data of Performance test, Function test and Field test is generally good during 3 months. also we checked that thermal variation test and EMI/EMS compliance test are good result data within allowable range. As a result of general test, we verified improvement results that the measure distance of fire detection extend 75 m, the Power of waiting time increase 4 hours, the Power of operation time increase 3 days and the context awareness with video as well as sensors.

A Study for Performance Improvement of Fire Detector and Sprinkler Head in Apartment Houses (공동주택 화재감지 및 소화성능개선에 관한 연구)

  • Lee, Chae-Won;Son, Bong-Sei
    • Fire Science and Engineering
    • /
    • v.29 no.1
    • /
    • pp.38-44
    • /
    • 2015
  • This study suggested the problems and their improvement measures for the operation of fire detectors and sprinkler heads installed at apartment houses. According to a census on population and housing in 2010, apartment houses account for 71.6% of the total housing facilities. And by fire statistics data of the National Emergency Management Agency, approximately 25.0% of fire accidents and 46.4% of casualties occur at apartment houses every year. Therefore, this study conducted for identifying the causes and characteristics of fire to establish the fire safety improvement measures for apartment houses. And this study was carried out virtual fire simulation at domestic apartment houses. The scenario of the simulation contains a comparative analysis on the operation time of standard sprinkler heads and residential sprinkler heads, heat detectors and smoke detectors. As a result of simulation, it was found that standard sprinkler heads and heat detectors installed at the existing apartment houses should be replaced with residential sprinkler heads and smoke detectors for rapid fire suppression. In addition, sprinkler systems should be considered to be installed for excluded floor at apartment houses. Especially, it is necessary to construct remote inspect systems like advanced countries for efficiency of apartment houses safety management.