• 제목/요약/키워드: Fire properties

검색결과 1,166건 처리시간 0.025초

우리나라 중요목조문화재의 효과적 화재진압을 고려한 기본특성분석에 관한 연구 (The study of basic quality analysis for an effective fire suppression of the main temple properties in Korea)

  • 정은지;신호준;이지향;김정호;백민호
    • 한국화재소방학회:학술대회논문집
    • /
    • 한국화재소방학회 2008년도 추계학술논문발표회 논문집
    • /
    • pp.471-478
    • /
    • 2008
  • This study grasps the type and site area of properties, the size of properties, the distance between the wooden properties and fire station, the direction of a fire engine in the wooden properties, the member of self-protection, and the present condition of fire fighting. And the 121 main temples properties in Korea is researched for an effective fire suppression.

  • PDF

아트리움 공간에 있어서 화재온도성상에 관한 이론해석 (The Analytical Study of Fire Properties in Atrium Space)

  • 김화중;이지희;최금란;김경례
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1993년도 가을 학술발표회논문집
    • /
    • pp.113-119
    • /
    • 1993
  • Atrium being on fire, the flame is spread vertically, the methods of fire protection and the standards of security are different respectively. Therefore, in the case of atrium, it has many problems on the fire protection and the application of statute according to the space properties. So it is important to analysis, atrium being on fire, fire properties to space properties. From these points of view, the purpose of this study is to analysis the fire properties of atrium .

  • PDF

중요사찰목조문화재의 소방대책을 고려한 실태조사에 관한 연구 (A Study about Research on the Actual Condition for Fire Counterplan of Main Temple Wooden Cultural Properties)

  • 백민호;신호준
    • 한국화재소방학회논문지
    • /
    • 제23권3호
    • /
    • pp.121-130
    • /
    • 2009
  • 본 연구에서는 문화재청에서 지정한 국가지정 중요목조문화재 124곳 중 중요사찰목조문화재 80곳에 대하여 2008년 6월부터 12월까지 각 사찰에 대해 현지조사와 사찰을 관장하는 각 관할소방서에 대한 화재진압 매뉴얼의 자료조사를 실시하였다. 조사내용은 문화재지정구분, 소재지구분, 사찰부지면적, 사찰 내 건축면적, 지정문화재의 건축면적, 화재발생시 화재진압을 위한 소방차의 진입방향, 소방관서와의 거리, 방화관리자의 지정현황을 조사하였다. 또한, 각 사찰의 문화재보유특성에는 사찰경내의 목조건물이 중요목조문화재로 지정이 되어 있는 경우와 석탑, 불상, 탱화, 종, 석등, 부도, 현판, 주련 등이 보유문화재로 지정되어 있어 각 문화재를 유형별로 이동 운반이 가능한 소산문화재와 이동 운반이 불가능한 불소산문화재로 분류 조사하였으며, 각 문화재의 재질을 조사하여 화재발생시 신속한 초기 대응과 문화재 피해 최소화를 위한 기초 연구결과를 정리하였다.

국가지정 목조문화재의 소방대책에 관한 실태조사 (The Study for Fire Prevention of Main Wooden Cultural Properties of Korea)

  • 백민호;이지향
    • 한국화재소방학회논문지
    • /
    • 제24권3호
    • /
    • pp.1-8
    • /
    • 2010
  • 본 연구에서는 문화재청에서 지정한 123개 목조문화재를 대상으로 소방대책을 고려한 실태조사 및 분석을 다음과 같이 실시하였다. 첫째 우리나라 목조문화재의 관리 및 원인별 화재발생현황을 조사하여 정리하였다. 둘째, 123개의 중요목조문화재에 대하여 2008년 8월부터 10월까지 현장조사 및 유관기관 자료조사를 실시하여 문화재의 지정구분, 소재지구분, 해당건축면적, 보유문화재수, 소방시설현황, 소방차의 진입방향, 자위소방대 인원, 방화관리자 선임여부, 소방서와의 거리 및 소요시간 등의 소방대책 마련에 필요한 내용들을 조사 분석하여 중요목조문화재의 기본현황을 정리하였다. 셋째, 위의 조사 자료를 기본으로 123개 중요목조문화재의 화재발생을 고려한 위험도를 살펴보고자 문화재의 내부적 현황과 외부적 현황으로 구분하여 평균지수에 의해 분석하고 우리나라 중요목조문화재의 소방대책수립을 위한 기초자료를 정리하였다.

고층빌딩의 아트리움 공간에 있어서 화재성상에 관한 실험 연구 (The Experimental Study of Fire Properties in Atrium Space of High-rise Buildings)

  • 김화중;양승호;최금란
    • 한국화재소방학회논문지
    • /
    • 제7권2호
    • /
    • pp.13-23
    • /
    • 1993
  • Recently, the plans and constructions of atrium are prevalent widely. But. in the case of atrium it has many problems from the viewpoint of space properties of atrium. Therefore, planning of fire protection is required urgently. The purpose of this study is to analysis the fire properties on the several heights of atrium through three models which the ratio of atrium's width to height is 1:1, 1:1.5 and 1:2 respectively.

  • PDF

철근콘크리트 구조물의 내화성능에 관한 연구 (A Study on the Fire Resisting Properties of Reinforced Concrete Structures)

  • 김무한;송하영
    • 한국화재소방학회논문지
    • /
    • 제2권1호
    • /
    • pp.3-10
    • /
    • 1988
  • Concrete is incombustible and has good fire resisting properties, i. e. when exposed to fire it continues to perform satisfactorily for a reasonable period of time. Nevertheless, with time and high temperature gradient, brought about the fire, causes cracking and spatting. Further deterioration and loss of strength are caused by gradual dehydration of concrete paste. This paper is aimed to make a proposal for the design and construction of reinforced concrete structures with more sufficent resistance to fire by the theoritical analysis, which is base4 on investigation of general damages by the fire and change of properties on concrete influenced by high temperature.

  • PDF

산불이 산림토양의 이화학적 성질에 미치는 영향 (Fire Effects on Soil Physical and Chemical Properties following the Forest Fire in Kosung)

  • 이원규;김춘식;차순형;김영걸;변재경;구교상;박재욱
    • The Korean Journal of Ecology
    • /
    • 제20권3호
    • /
    • pp.157-162
    • /
    • 1997
  • Changes on soil physical and chemical properties following the forest fire in Kosung area in Kangwon province were examined. Twenty seven sampling plots[16 burned (8 low intensity fire, 8 high intensity fire) and 11 unburned plots] from Pinus densiflora community were chosen and soil samples from three depths(0-5, 5-15, 15-25 cm) under the forest floor were collected. Forest fire in the area affected soil chemical properties. Soil pH, available phosphorus, base saturation, K, Ca, and Mg on the surface soil(0-5cm) in the burned areas compared with the unburned areas were increased, while soil properties on the subsurface soil(5-25 cm) were not changed. Organic matter, total nitrogen, available phosphorus, and exchangeable cations following the high in tensity fire on the surface soil were generally lower than those in the low intensity fire areas. This indicates that these nutrients on high intensity fire areas may be volatilized. The results suggest that the fire effects on soil chemical properties were confined mainly to the surface soil and were different between the high and the low intensity fire types.

  • PDF

스프링클러 소화설비의 목조문화재 소화성능에 관한 연구 (The Study of Fire Suppression Capability of Sprinkler System for Wooden Cultural Properties)

  • 노삼규;함은구;김동철
    • 한국화재소방학회논문지
    • /
    • 제25권6호
    • /
    • pp.51-57
    • /
    • 2011
  • 본 연구는 국내 목조문화재의 화재에 대한 수계 자동소화시스템 중에 범용의 스프링클러 소화시스템에 대한 소화성능을 소화실험을 통하여 확인해 보았다. 목조문화재는 가연성의 재질로 구성되어 있어 화재에 취약하며, 방화의 경우 화재의 성상 초기부터 화원의 규모가 커질 수 있다. 본 실험에 적용된 스프링클러 헤드는 방사압 1 bar, 방수량 80 lpm의 사양을 지니고 있다. 소화실험의 유형은 화원의 규모별, 문화재 규모별로 각각 둘로 구분하여 소화성능을 실험하였다. 소화실험을 통해 확인된 사항은 천장이 높으면 소화 시간이 지연되는 결과가 발생하며, 화원의 규모가 2단위에서는 소화는 가능하였지만 소화가 지연되는 것으로 나타났다. 그 결과 천장이 높고, 화원의 규모가 2단위 이상이 되면 소화성능이 낮을 것으로 예측된다. 실제 목조문화재의 화재 성장 환경이 소화실험 모형보다 유리하다는 측면을 고려해야 한다. 그러므로 스프링클러 소화설비를 목조문화재에 적용 할 때에 헤드간 거리 헤드의 선정 등 충분한 검증이 요구된다.

Fire Resistance Studies on High Strength Steel Structures

  • Wang, Wei-Yong;Xia, Yue;Li, Guo-Qiang
    • 국제초고층학회논문집
    • /
    • 제7권4호
    • /
    • pp.287-298
    • /
    • 2018
  • High strength steels have been widely applied in recent years due to high strength and good working performance. When subjected to fire conditions, the strength and elastic modulus of high strength steels deteriorate significantly and hence the load bearing capacity of structures reduces at elevated temperatures. The reduction factors of mechanical properties of high strength steels are quite different from mild steels. Therefore, the fire design methods deduced from mild steel structures are not applicable to high strength steel structures. In recent ten years, the first author of this paper has carried out a lot of fundamental research on fire behavior of high strength steels and structures. Summary of these research is presented in this paper, including mechanical properties of high strength steels at elevated temperature and after fire exposure, creep response of high strength steels at elevated temperature, residual stresses of welded high strength steel member after fire exposure, fire resistance of high strength steel columns, fire resistance of high strength steel beams, local buckling of high strength steel members, and residual strength of high strength steel columns after fire exposure. The results show that the mechanical properties of high strength steel in fire condition and the corresponding fire resistance of high strength steel structures are different from those of mild steel and structures, and the fire design methods recommended in current design codes are not applicable to high strength steel structures.

화재시 온도증가로 인한 RC 슬래브의 강도 특성 (Strength Properties of RC Slabs under Elevated Temperatures from Fire)

  • 임초롱;정철헌;김유석
    • 한국안전학회지
    • /
    • 제25권4호
    • /
    • pp.48-60
    • /
    • 2010
  • The fire resistance performance of 2 RC slabs after exposure to the ISO-834 fire standard without loading has been experimentally investigated. A Comparison is made of the fire resistance performance between RC slabs without PP(polypropylene) fibers and RC slabs with PP fibers. From the fire test results, the presence of PP fibers in RC slabs can reduce spalling and enhance their fire resistance. Until now, the determination of fire resistance of reinforced concrete(RC) slabs has essentially been based on tabulated data. According to ACI 216 code and EUROCODE 2, the design of concrete structures is essentially based on tabulated data for appropriate concrete cover and various fire durations. From the comparison between fire test results and codes, current fire design provisions of codes such as the ACI 216 and the EUROCODE 2 are unconservative for estimating mechanical properties of RC slabs at elevated temperatures.