• Title/Summary/Keyword: Fire pattern

Search Result 338, Processing Time 0.026 seconds

Study on the Diagnostic Indicators of Fire-heat Pattern Identification in Stroke Patients (중풍환자의 화열변증 진단지표에 관한 연구)

  • Lee, Jung-Sup;Ko, Mi-Mi;Kang, Byoung-Kab;Kim, Jeong-Cheol;Kim, Bo-Young;Lee, In;Kim, Yun-Sik;Choi, Sun-Mi;Bang, Ok-Sun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.23 no.2
    • /
    • pp.499-504
    • /
    • 2009
  • The purpose of this study was to evaluate the diagnostic indicators which are used for the identification of fire-heat pattern in stroke patients. For evaluation of diagnostic indicator, we analyzed the indicators which are composed of symptoms and signs collected from stroke patients based on the clinical records using case report form (CRF). Patients had a first-ever stroke within 1 month after the onset of stroke. Pattern identification was performed and decided by two independent physicians. Two patient groups that consist of fire-heat pattern and the other patterns were compared to isolate important indicators affecting the fire-heat pattern identification of stroke patients. The 8 indicators among 16 fire-heat pattern indicators were significantly more frequent compared with non fire-heat pattern group. Logistic regression analysis revealed that 5 indicators among fire-heat indicators were significantly sensitive indicators being capable of identification of fire-heat pattern. But two of them was from the indicators of dampness-phlegm pattern and yin deficiency pattern. Therefore, further studies are required for the development of Korean standard indicators of Fire-heat pattern identification.

Analysis on Deployment of Fire Service Force in Korea (한국 소방력배치의 실태 분석)

  • Back, Min-Ho;Lee, Hae-Pyeong
    • Fire Science and Engineering
    • /
    • v.20 no.1 s.61
    • /
    • pp.55-70
    • /
    • 2006
  • The purpose of this study is to analyze an adequate deployment of fire service force to be prepared to respond appropriately and effectively in Korea by settlement pattern. In order to examine the deployment of fire service force by the present standard, we analyzed the logical basis and the deployment of fire service force by city and province. We also classified clusters for settlement pattern through the statistical methods and raised several points for the existing deployment model of fire service force by the classified settlement pattern. As a result, it was confirmed that the deployment of fire service force by the settlement pattern was irrelevant to fire service need.

Correlation Study between the Changes of the Fire- and Heat- Related Symptoms and Motor Function Recovery in Acute Cerebral Infarction Patients (급성기 뇌경색 환자의 화열증상 변화와 기능회복도간의 상관관계에 대한 연구)

  • Hyun, Sang-Ho;Min, Kyung-Dong;Yei, Young-Chul;Kang, Ah-Reum;Lee, Eun-Chan;Moon, Sang-Kwan;Cho, Ki-Ho;Jung, Woo-Sang;Park, Sung-Wook;Ko, Chang-Nam
    • The Journal of Internal Korean Medicine
    • /
    • v.34 no.4
    • /
    • pp.428-437
    • /
    • 2013
  • Objectives : The aim of this study was to examine if there is a significant correlation between the changes of Fire- and Heat- related symptoms and motor function recovery in acute cerebral infarction patients. Methods : We studied inpatients within a month after the onset of cerebral infarction who were admitted at Kyunghee University Medical Center from May 2011 to January 2013. We executed correlation analysis between Fire-heat pattern score and motricity index score at visit 1 and visit 2, and checked if there was a significant correlation between the changes of Fire-heat pattern score and changes of motricity index score. Also, we compared the changes of both scores in patients taking Fire-heat and non Fire-heat pattern prescriptions. Results : There was a significant correlation between the Fire-heat pattern score and Motricity index score at visit 1 and visit 2, and changes of Fire-heat pattern score showed significant correlation with changes of motricity index score. Patients taking Fire-heat pattern prescriptions showed significant change in Fire-heat pattern score after herb-medication treatment while patients taking non-Fire-heat prescriptions showed insignificant change in Fire-heat pattern score. Conclusions : This study provides evidence that taking a Fire-heat pattern prescription could be considered as a first line herb-medication treatment in acute cerebral infarction patients.

A study on the burned pattern of plastic wastebasket by reconstruction (플라스틱 휴지통의 연소 재현 실험을 통한 발화지점 축소 방법)

  • An, Seong-Il
    • Journal of Korean Institute of Fire Investigation
    • /
    • v.3 no.1
    • /
    • pp.38-42
    • /
    • 2003
  • There are many origins of fire which are offered by many path, such as cigarette-butt, light of match, playing with fire, arson, and other, in and around wastebasket. Because of above-mentioned thing and the quality of the plastic, it is very difficult to discriminate the difference of burned pattern between in and around wastebasket, between an accidental fire and arson in oder to investigate the point of fire. In this study, the wastebaskets filled up with 2/3 combustibles, and then, in and around wastebasket using the gas lighter by ignitor, and we observe how the fire spread. As a result, if wastebaskets are burned inside the limit 50%, we discriminate the difference of burned pattern between in and around wastebasket. But, if wastebaskets are burned more thant 50%, it is impossible to discriminate the difference of burned pattern between in and around wastebasket.

  • PDF

Study of the Specific Indicators Calculation of Fire-Heat Pattern Identification and Yin Deficiency Pattern Identification in Stroke (중풍 화열 변증과 음허 변증을 구분하는 특정 지표 산출에 대한 연구)

  • Kang, Baek-Gyu;Kang, Byeong-Kab;Lee, Jung-Sup;Han, Deok-Jin;Nam, Sang-Kyu;Shin, Sun-Ho;Moon, Byung-Soon;Lee, In
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.22 no.6
    • /
    • pp.1368-1373
    • /
    • 2008
  • This study was done to calculate the specific indicators of Fire-Heat Pattern Identification and Yin Deficiency Pattern Identification settled by tentative Korean Standard Differentiation of the Symptoms and Signs for Stroke. The subjects were 764 hospitalized patients with stroke, and a list of registry was made for each of them. Frequency and Correlations among Fire-Heat and Yin Deficiency indicators were studied. Fire-Heat pattern group included 175 patients out of 764, Yin Deficiency pattern group included 103 patients out of 764. Among the indicators of Fire-Heat pattern, those, in order of highest frequency, were 'heat vexation and aversion to heat', 'reddened complexion', 'thirst'. Among the indicators of Yin Deficiency pattern, those, in order of highest frequency, were 'dry mouth', 'red tongue', 'fine and rapid pulse'. Among the Fire-Heat pattern indicators, 'yellow fur' and 'thirst', 'heat vexation in the chest' and 'vexation and insomnia' showed most significant correlation. Among the Yin Deficiency pattern indicators, 'aphtha or tongue sore' and 'heat in the palms and soles', 'red tongue' and 'dry fur' showed most significant correlation. 'Reddened complexion', 'dry eyes', 'surging and parid pulse', 'heat vexation and aversion to heat' are classify between Fire-Heat pattern and Yin Deficiency pattern. 'Surging and parid pulse', 'Reddened complexion' are mostly representative of Fire-Heat pattern and 'fine and rapid pulse' are mostly representative of Yin Deficiency pattern.

Clinical Study on Relationship between Pattern Identifications and Heart Rate Variability (변증과 심박변이도의 상관성 연구)

  • Choi, Sang Ok;Park, Sun Young;Jeong, Hui Jin;Jung, So Youn;Ahn, Su Yeun;Kim, Kyoung Min;Kim, Young Kyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.27 no.3
    • /
    • pp.318-326
    • /
    • 2013
  • This study was performed to investigate relationship between each pattern identification and heart rate variability(HRV) indices. We analyzed 201 subjects who participated in stroke check up. We classified the subjects into four groups of pattern identifications; Fire-Heat pattern(FH), Yin Deficiency pattern(YD), Qi Deficiency pattern(QD) and Dampness-Phlegm pattern(DP) that based on Korean Standard Pattern Identifications for Stroke-III. We investigated significance of HRV indices between each pattern identification and heart rate variability indices. The total number of the subject group was 201, whereas the groups were divided into four groups; Fire-Heat pattern group(n=47), Yin Deficiency pattern(n=65), Qi Deficiency pattern(n=33), and Dampness-Phlegm pattern(n=56). SDNN, TP, Ln(TP), VLF, Ln(VLF), LF, Ln(LF) and HF were significantly higher in the Fire-Heat pattern(FH) group than other groups of pattern identifications, but there was no differences among the Yin Deficiency group, the Qi Deficiency group and the Dampness-Phlegm group. Ln(HF), LF(NORM), HF(NORM) and LF/HF ratio were significantly higher in the Fire-Heat group than in the Qi Deficiency group. However, there was no significant differences among the Dampness-Phlegm group, the Yin Deficiency group, Fire-Heat group and the Qi Deficiency group. Through this study, we found out some significant relationships between each pattern identification group and HRV indices. The result of this study demonstrates that sympathetic nerve was more active in the Fire-Heat group than other groups.

Growth Characteristics and Hydrocarbon Patterns of Flammable Liquid on a Vinyl Layer (비닐장판 위에서 연소된 인화성 액체의 성장 특성과 탄화 패턴)

  • Joe, Hi-Su;Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.32 no.5
    • /
    • pp.15-21
    • /
    • 2018
  • This study examined the growth characteristics and carbonization pattern when a fire occurs due to a flammable liquid sprinkled on a vinyl floor. When acetone was sprinkled on a floor, the flame reached its peak in approximately 0.2 s after it was ignited. The lower part of the flame showed a laminar pattern while the upper part showed a turbulent pattern. The pattern showed a turbulent pattern and generated white smoke. The combustion completed floor surface showed carbonization of a dim pore pattern. In the case of benzene, an intense flame was formed in approximately 0.6 s after ignition. The flame length was measured to be approximately 50 mm. When the flame became weak, a significant amount of black smoke was generated due to incomplete combustion. The combustion completed floor surface showed carbonization of a pour pattern and splash pattern. In the case of alcohol, an intense flame was formed in approximately 1.1 s after ignition. In addition, the depth of carbonization was significant where the flammable liquid was collected and a trace of carbonization was observed at the boundary of the flow path of the flammable liquid.

Analysis of Unwanted Fire Alarm Signal Pattern of Smoke / Temperature Detector in the IoT-Based Fire Detection System (IoT 기반 화재탐지시스템의 연기 및 온도감지기 비화재보 신호 패턴 분석)

  • Park, Seunghwan;Kim, Doo-Hyun;Kim, Sung-Chul
    • Journal of the Korean Society of Safety
    • /
    • v.37 no.2
    • /
    • pp.69-75
    • /
    • 2022
  • Fire-alarm systems are safety equipment that facilitate rapid evacuation and early suppression in case of fire. It is highly desirable that fire-alarm systems have low false-alarm rates and are thus reliable. Until now, researchers have attempted to improve detector performance by applying new technologies such as IoT. To this end, IoT-based fire-detection systems have been developed. However, due to scarcity of large-scale operational data, researchers have barely studied malfunctioning in fire-alarm systems or attempted to reduce false-alarm rates in these systems. In this study, we analyzed false-alarm rates of smoke/temperature detectors and unwanted fire-alarm signal patterns at K institution, where Korea's largest IoT-based fire-detection system operates. After analyzing the fire alarm occurrences at the institution for five years, we inferred that the IoT-based fire-detection system showed lower false-alarm rates compared to the automatic fire-detection equipment. We analyzed the detection pattern by dividing it into two parts: normal operation and unwanted fire alarms. When a specific signal pattern was filtered out, the false-alarm rate was reduced to 66.9% in the smoke detector and to 46.9% in the temperature detector.

Assessment of the Combustion Diffusion Pattern and Fire Risk of a Water Purifier Damaged by a General Fire (일반화염에 의해 소손된 정수기의 연소 확산 패턴 및 화재위험성 평가)

  • Choi, Chung-Seog
    • Fire Science and Engineering
    • /
    • v.26 no.3
    • /
    • pp.35-39
    • /
    • 2012
  • This paper analyzes the combustion diffusion pattern when a water purifier is artificially ignited outside and inside in order to provide data to examine the cause of fire of a water purifier damaged by fire. The analysis result of the combustion diffusion pattern of a water purifier shows that the combustion diffused at a higher speed when it was ignited inside the purifier than when ignited outside. It took approximately 360 seconds for the water purifier to be half-burned when ignited on the outside, and approximately 180 seconds when ignited from inside. That is, it is thought that the internal combustion speed is higher because the internal ignition causes the generated heat to be accumulated and radiated instantly. It was observed that the water purifier damaged by fire caused by external ignition showed a uniform carbonization pattern and the carbide burned down at the bottom were gradually deposited. The water purifier damaged by internal ignition showed a relatively clear boundary of carbonized surface, which formed a V-pattern. The difference in the combustion patterns presents an objective base from which to determine where the fire started. By the time the purifier was half-burned by fire, the built-in fuse had not melted and the power supply protection device did not operate. In addition, as was found in the case of the fuse damaged by a general fire, carbonization occurred at the metal holder, and it is thought that this fact may be used as a basis from which to determine the cause of a fire.

Clinical Study on Relationship between Pattern Identifications for Stroke and the Second Derivative of Photoplethysmogram Waveform from Stroke Preventive Examination (중풍 예방 검진에서 중풍 표준화 변증과 가속도맥파의 상관성 연구)

  • Jung, So Youn;Hur, Hee Soo;Jeong, Hae Ryong;Kim, Kyoung Min;Kim, Young Kyun
    • Journal of Physiology & Pathology in Korean Medicine
    • /
    • v.29 no.3
    • /
    • pp.230-239
    • /
    • 2015
  • This study was performed to find a relationship between each pattern identification and vascular status using the second derivative of photoplethysmogram waveform(SDPTG) indices. We analyzed 200 subjects who participated in stroke preventive examination. We classified the subjects into four groups of pattern identifications; Fire-Heat pattern(火熱證; FH), Yin Deficiency pattern(陰虛證; YD), Qi Deficiency pattern(氣虛證; QD) and Dampness-Phlegm pattern(濕痰證; DP) that based on Korean Standard Pattern Identifications for Stroke-Ⅲ. We studied a relationship between each pattern identification and the SDPTG. The total number of the subject group was 200, whereas the groups were divided into four groups; Fire-Heat pattern group(n=49), Yin Deficiency pattern(n=57), Qi Deficiency pattern(n=45), and Dampness-Phlegm pattern(n=49). b/a ratio was related with age and systolic blood pressure, c/a ratio was associated with age, systolic blood pressure, fasting blood sugar and Total cholesterol, d/a ratio was affected with age, diastolic blood pressure, and hypertension, e/a ratio was related with age and sex and SDPTG AI was associated with age. c/a ratio and d/a ratio were significantly higher in the Fire-Heat group than in the Qi Deficiency group. SDPTG AI was significantly higher in the Qi Deficiency group than in the Fire-Heat group. The Qi Deficiency group was significantly older than the Fire-Heat group and the number of hypertension patients was significantly more in the Fire-Heat group than in the Qi Deficiency group. Through this study, we found out some significant relationships between each pattern identification group and the SDPTG indices.